| 1 | 4.7.1 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth and lift up to 1.5 m, as directed by Engineer-in- Charge.All kinds of soil |
| 2 | 4.12.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge.All kinds of soil. |
| 3 | 10.16 CEMENT CONCRETE FLOORING Providing and laying cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete |
| 4 | 11.6.2 CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix :2 1:6 (1 cement: 6 fine sand) |
| 5 | 11.25.1 POINTING ON BRICK WORK Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand):1 Flush / Ruled/ Struck or weathered pointing |
| 6 | 13.29.2 SIGLE/BUILT-UP STEEL/TUBULAR SECTIONS Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 7 | 10.100.2 Cement Concrete 1:8:16 FlooringCement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth. |
| 8 | 11.78 INTERIOR FINISHING Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. |
| 9 | 7.20.2 B BRICK WORK Brick work with common burnt clay modular bricks of class designation 10.5 in foundation and plinth in:2 Cement Mortar 1:6 (1 cement : 6 coarse sand) |
| 10 | 30.24 FINISHING WORKS Distempering with dry distemper of approved brand and manufacture(one or more coats) and of required shade on old work to give an even shade. |
| 11 | 6.1.1 A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level:1 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 12 | 6.2.2 A CEMENT CONCRETE (CAST IN SITU) Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets,coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor four level, excluding the cost of centering, shuttering and finishing:2 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 13 | 6.8.2 B DAMP-PROOF COURSE Providing and laying damp-proof course with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)2 40mm thick |
| 14 | 6.29.3 CENTRING AND SHUTTERING (FORM WORK) Centering and shuttering including strutting, propping etc. And removal of form work for :3 Columns, piers, abutments, pillars, posts and struts |
| 15 | 34.29.1 Cautionary Sign Boards GI barbed wire fencing1 G.I Barbed Wire Fencing 1.2 Metre High Providing and fixing 1.2 metres high GI barbed wire fencing with 1.8 m angle iron posts 40 mm x 40 mm x 6 mm placed every 3 metres centre to centre founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 9 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 807 |
| 16 | 6.33.3 STEEL REINFORCEMENT Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level3 Cold twisted bars |
| 17 | Job Work Analysis of rates for earth cost or compensation for earth taken from private land complete in all respect. Please Enable Macros to View BoQ information |