| 1 | Loading, carriage & unloading of following materials from centre store daliganj to work site and its stacking. Distance approx. (0-35) kms. |
| 2 | 250 KVA T/F |
| 3 | LT PVC Cable 1X400/3.5X240/1X70 SQMM |
| 4 | 11 KV Cable XLPE |
| 5 | 11 KV CJ KIT O/D,I/D/ST |
| 6 | Construction of T/F Plinth of size 2x2x1.2 meters with help of 1st class bricks and missionary in the ratio 1:4 cement & sand coarse, filling the structure completely as per norms with RCC top 1:2:2 cement, sand coarse, stone grit with MS bar and MS channel for resting T/F. All material shall be arranged by the contractor. |
| 7 | Wiremess fencing of 11/0.4 KV shall be made of rectangular of size per site requirement not exceeding 3 meter fabrication 45x45x5 mm angle the frame is also have 1 no. Horizontal runner of MS flat 40x5 welded in middle to support of wire mess. Rectangular welded type wire mess of size 50x25 made of 12 S.W.G. wire mess shall be welded all along the periphery of the frame as wll as on horizontal runner to give extra strength of welding to wire mess welded on the frame. Diagonal bracing of all the frame panel will be welded with MS flat of size 25x3mm to supports as per RESPO specification & direction of E/I. including painting of fencing with two coat of primer and two coat of enamel paint. |
| 8 | Construction of Masonry type Distribution pillar box with first class brick ballast cement, coarse sand, local sand, brick ballast and MS round bar of 10 mm dia including supply and mounting of 02 nos. Straight MS angle 50x50x6x750 mm-2 nos. |
| 9 | Supply and fixing of Henley type tailless fuse units 500 Amps, 650 Volts one no. for incoming and other for outgoing, Copper bus bar 4 nos. 1000x50x6 mm with locking arrangement made of 18 SWG BP Sheet. |
| 10 | Laying of LT PVC Cable 1x400/3.5x240 SQMM as RESPO specification & direction of E/I. |
| 11 | Earthing of T/F Pipe type with 60 fit deep boring and providing GI Pipe 1.5\\" dia (60 fit GI Pipe) and GI strip 50x5 mmx6 meter long attached with clamps. L piece, nut & bolts and GI pipe Cap. All material shall be supplied by the contractor. |
| 12 | Safe Installation of 250 KVA T/F on double pole by providing and fixing of all accessories along with making HT/LT connection and its commissioning. |
| 13 | Dismantling of 63 KVA T/F on existing plinth along with dragging, loading cartage and unloading to works site J.E. dump store/Central store. |
| 14 | Loading carriage and unloading of Dismental Transformer from JE Store to Central Stote. |
| 15 | Providing & Fixing of DO Fuse set along with clamps & nut bolts on new/existing double pole. |
| 16 | Providing & Fixing of Channel for 11KV DO Set as per RSPO Norms. |
| 17 | Providing & Fixing of 11KV TPMO along with clamps & nut bolts and pipe on new/existing of double pole. All size Channel/Angle provided by Contractor. |
| 18 | Providing & Fixing of Channel for TPMO set as RESPO Norms. |
| 19 | Odinary earthing by MS earth Rod 2500 mm long as per RESPO Schedule. Only GI wire & Earth Rod shall be supplied by the department. |
| 20 | Laying of Cable single circuit 11KV XLPE Cable (3x35/70/120/170/185) sqmm in pakka Road by bore type method as per RESPO specification & direction of E/I. |
| 21 | Supply & Laying of interlocking tiles inside T/F Fencing. |
| 22 | Painting of pole as per RESPO Specification with two coat of primer and two coat fo enamel paint. |
| 23 | Supply & fixing as per norms |
| 24 | Alu. LUG 70/250/400/630 KVA |
| 25 | DANGER BOARD WITH BARBED WIRE |
| 26 | Change over switch 630 Amp as per direction of E/I. |
| 27 | Change over switch 200 Amp as per direction of E/I. |
| 28 | Number plate |
| 29 | Cu bus bar GST will be paid extra as per rule. Please Enable Macros to View BoQ information |