| 1 | Designing and construction of footing foundation for octagonal pole of desired size including excavation in soil/soft rock,base concrete M-7.5 (1:4:8), 15mm thickand pedestal of RCC M-20 (1:1.5:3), required tar steel reinforcement for required size from base concrete,shuttering, curing etc. with existing foundation bolts complete as per specifications in an approved manner asper manufacturer drawing or engineer-incharge.(1.5 cmt per pole) as per s.o.r |
| 2 | Providing and erection of black painted galvanized decorative designer poles in different section, top 60mm dia., bottom 140mm dia. with gold colour painted ornamental cast aluminium ring having lockable weather proof flush door junction box in bottom section,base plate dia. 290mm having 4 holes of 22mm dia. complete erected in an approved manner on existing foundation. Suitable size & type of foundation bolts 4 nos. X 16mm X 450mm 'J' type (EN8 grade) 5 meter height |
| 3 | Supply of light Fixture shall be made of die cast aluminium alloy. The fixture size is 600x360 mm and wattage of 60 W for area lighting. Diffuser is made of high reflective acrylic sheet. Light Output of source is more than 100 m/watt, CRI>80, SpD 4 K, operating Voltage. 140-270V. fitting is IP65, wired with branded LED and Philips/ Fulham make driver. Proper thermal management for longer life of fixture. Led brning of 50,000 hours BT-PT- Hexa-60 |
| 4 | Supply, fixing, testing & commissioning wall/floor mounted LT panel primer coated with powder coated paint & provided with required gasket for dust/vermin proof with degree of protection IP42 suitable for 415Volt 3phase, 50 Hz, 4 wire system fabricated out of CRCA sheet upto 2 mm thick (1.6 mm for doors) duly compartmentalized for incomer, bus section, outgoings,cable alleys & CT, PT Ampere Metre, Volt Metre, selector switches, frequency Metre, phase indicating lamp, EnergyMetre complete including cost of busbar supports, detachable cable gland plates, 2 earthing terminals, internal wiring & fixing of separately supplied MCBs MCCBs, ACB, panel mounted changeover switch/SFUs, etc. as required but excluding cost of busbarstrips, Ampere Metre, Volt Metre, selector switch as per approved design and specification. |
| 5 | Supply of XLPE Insulated power cable (conforming IS- 7098 ) 1100 Volt grade/Heavy duty power cable conforming to IS 1554-1100 Volts grade , 2 core /3½ core/4 coreISI MARKED with Alu. Stranded /solid conductor ARMOURED 4 CORE 10 Sq.mm.(XLPE) make polycab/ havells/phinolex |
| 6 | Supplying and installing Double wall corrugated pipes (DWC) of HDPE ( IS 14930 Part II -marked ) for cable laid under ground with necessary connecting sockets/ couplings,tees of same material and at required depth upto 90cm. below road/ground surface,including excavation, back filling with excavated material with ramming and making the surface good. 50mm outside dia. |
| 7 | Laying of one number PVC insulated and PVC sheathed power cable of 1:1 kV grade of size not exceeding 25 Sq.mm in the existing RCC hume/ Stone/ Ware/ G.I. pipe as required. |
| 8 | CIRCUIT WIRING IN EXISTING CONDUIT/PVC CASING CAPPING Supplying and drawing single corePVC insulated cable FR with copper multi strand conductor ISI marked in existingrigidconduit in surface or concealed as per specification. 2.5 Sq mm cable 3 X 2.5 sq mm make polycab/ havells/phinolex |
| 9 | Change of timer renowned make. |
| 10 | Change of Contactor renowned make. |
| 11 | Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415 Volts, 50 Cycle 10 kA Value AC supply confirming to IS : 8828 : 1996, IEC : 60898:2002 but without enclosures :- FOR TRIPLE POLE & NEUTRAL(TPN) 50 Amp to 63 Amp Rating make havells |
| 12 | Supplying of ISI Marked and accepted standard of Miniature CircuitBreaker( MCB) of'C'series suitable for 240/415 Volts,50 Cycle,10kA Value AC supply confirming toIS:8828:1996, IEC: 60898:2002 but without enclosures :-SINGLE POLE (SP) 0.5 Amp to 5 Amp Rating make havells |
| 13 | Labour charges for fixing sheet steel enclosure,MCB DB surfacemounting type,as per accepted practiceon 25x5mmflatironclampsduly embedded in wall,cable connection etc. complete. 8.5 (1) to 8.5 (4) |
| 14 | Labour charges for fixing sheet steel enclosure,MCB DB surfacemounting type,as per accepted practice on 25x5mm flat iron clampsduly embedded in wall,cable connection etc. complete. 8.5 (5) & 8.5 to 8.6 (2) |
| 15 | Supplying and erecting earth pit of minmum bore dia 150 mm size, approved make safe earthing electrode consiting pipe in pipe tecnologie as per IS 3043-1987 made of corriosion free GI pipes having outer pipe dia of 50 mm having 80-200 micron galvanising, inner pipe dia of 25 mm having 20-250 micron galavinsing, connection teriminal dia of 12 mm with constent OHMIC value sourrounded by highly conductiv compund with high charge disipation sutible for effective and maintence free earthing with 2 mtr. Pipe in normal soil with 25 kg (one bag) back filling compound Please Enable Macros to View BoQ information |