Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Proposed Construction Work of Swimming Pool Timki Hansapuri, Tahsil & Dist- Nagpur, Maharashtra. |
| 2 | Dismantling brick masonry in lime or cement mortar and stacking the materils asdirected with all leads, lifts etc. |
| 3 | Dismantling stone masonry in lime or cement mortar including stacking thematerils as directed with all leads, lifts etc. |
| 4 | Removing lime or lean cement concrete including stacking the spoils as directedwith all leads, lifts etc, complete. |
| 5 | Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwing out the refusal outside etc. complete |
| 6 | Removing doors and windows with frames and stacking the materials as directedwith all leads, lifts etc. complete. |
| 7 | Removing rich mix cement concrete including stacking the spoils as directed with allleads, lifts etc, complete. |
| 8 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means Ground Floor |
| 9 | Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Manual Means Ground Floor |
| 10 | Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means Ground Floor |
| 11 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. Ground Floor |
| 12 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten yearsguarantee on bond paper. Ground Floor |
| 13 | Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete. Ground Floor |
| 14 | Filling in plinth and floors with approved excavated material in 15cm. to 20cm.Layers including watering and compacting etc. complete. Ground Floor |
| 15 | Transportation of material obtained from debris of various sorts including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed. (a) For 3 Km. Ground Floor |
| 16 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete.Ground Floor |
| 17 | Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.Ground Floor |
| 18 | Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Ground Floor |
| 19 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Ground Floor |
| 20 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Ground Floor |
| 21 | M Ground Floor |
| 22 | First Floor |
| 23 | M First Floor |
| 24 | Tower |
| 25 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Ground Floor |
| 26 | M Ground Floor |
| 27 | First Floor |
| 28 | M First Floor |
| 29 | Tower |
| 30 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Ground Floor |
| 31 | M Ground Floor |
| 32 | First Floor |
| 33 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Ground Floor |
| 34 | M Ground Floor |
| 35 | First Floor |
| 36 | M First Floor |
| 37 | Tower |
| 38 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Ground Floor |
| 39 | M Ground Floor |
| 40 | First Floor |
| 41 | M First Floor |
| 42 | Tower |
| 43 | Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Ground Floor |
| 44 | M Ground Floor |
| 45 | First Floor |
| 46 | M First Floor |
| 47 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.Ground Floor |
| 48 | M Ground Floor |
| 49 | First Floor |
| 50 | M First Floor |
| 51 | Tower |
| 52 | Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. Ground Floor |
| 53 | Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete. Ground Floor |
| 54 | M Ground Floor |
| 55 | First Floor |
| 56 | M First Floor |
| 57 | Tower |
| 58 | Providing and laying Cast in situ/Ready Mix cementconcrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided,finishing uneven and honeycombed surface and curing etc. complete.The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not beallowed.) With fine aggregate (Crushed sand VSI Grade) Ground Floor |
| 59 | M Ground Floor |
| 60 | First Floor |
| 61 | M First Floor |
| 62 | Tower |
| 63 | Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc.complete. Ground Floor |
| 64 | M Ground Floor |
| 65 | First Floor |
| 66 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Ground Floor |
| 67 | M Ground Floor |
| 68 | First Floor |
| 69 | M First Floor |
| 70 | Tower |
| 71 | Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete. Ground Floor |
| 72 | M Ground Floor |
| 73 | First Floor |
| 74 | M First Floor |
| 75 | Tower |
| 76 | Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. Ground Floor |
| 77 | M Ground Floor |
| 78 | First Floor |
| 79 | M First Floor |
| 80 | Tower |
| 81 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Ground Floor |
| 82 | M Ground Floor |
| 83 | First Floor |
| 84 | M First Floor |
| 85 | Tower |
| 86 | Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. Ground Floor |
| 87 | M Ground Floor |
| 88 | First Floor |
| 89 | M First Floor |
| 90 | Tower |
| 91 | Providing and applying one coat of seal cement primer of approved manufacture and shed including scaffolding preparing the surface by cleaning dirt and other foreign matters, scrapping if necessary including scaffolding etc. complete. Ground Floor |
| 92 | M Ground Floor |
| 93 | First Floor |
| 94 | M First Floor |
| 95 | Tower |
| 96 | Providing and applying plastic emulsion paint of approved quality, colour and shade to new surface in three coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete. Ground Floor |
| 97 | M Ground Floor |
| 98 | First Floor |
| 99 | M First Floor |
| 100 | Tower |
| 101 | Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item One Number 15 to 18 prior approval of Superintending Engineer will be necessary. Ground Floor |
| 102 | M Ground Floor |
| 103 | Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surfaceby thoroughly cleaning oil, grease, dirt and other materials as required,etc. complete. First Floor |
| 104 | M First Floor |
| 105 | Tower |
| 106 | Providing and applying antipeel paint of approved make & approved brand exterior Emulsion paint of approved quality, colour and shade to old and new surface in two coats, including exterior acrylic primer coat, scaffolding, preparing the surface etc. complete (Heat Reflective Paint). Ground Floor |
| 107 | M Ground Floor |
| 108 | First Floor |
| 109 | M First Floor |
| 110 | Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia. bars 3 Nos. And stirrups @250 mm c/c and fixing in wall with 6 Nos of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 100 mm . Ground Floor |
| 111 | M Ground Floor |
| 112 | First Floor |
| 113 | Providing sills of required material 20mm to 25mm thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, moulding edges, polishing,cleaning complete. b) Granite Ground Floor |
| 114 | M Ground Floor |
| 115 | First Floor |
| 116 | M First Floor |
| 117 | Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. Ground Floor |
| 118 | M Ground Floor |
| 119 | First Floor |
| 120 | M First Floor |
| 121 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Ground Floor |
| 122 | M Ground Floor |
| 123 | First Floor |
| 124 | M First Floor |
| 125 | Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Ground Floor |
| 126 | Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applyingwall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, interior wall finish luster 1st coat with brush/rubber/spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat or wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.) Ground Floor |
| 127 | M Ground Floor |
| 128 | First Floor |
| 129 | M First Floor |
| 130 | Providing and fixing 40mm diameter and 1.5 mm thick Stainless steel hand railing in S.S.304 Grade including fabricating ,fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete. Ground Floor |
| 131 | M Ground Floor |
| 132 | First Floor |
| 133 | M First Floor |
| 134 | Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1kg/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kg/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 kg/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. Ground Floor |
| 135 | M Ground Floor |
| 136 | First Floor |
| 137 | Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre /Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. Ground Floor |
| 138 | Providing Water proofing treatment to newly laid fully cured concrete slab of terraces by applying first coat of polymer modified semi-viscous paste prepared by mixing polymer of approved make and Cement in 1 : 2 proportion ( 1 litre polymer : 2 Kg. Cement) to a neatly cleaned and dust free concrete surface and upto 300 mm. over parapet wall prepared by removing loose and deposited material with brush and water, laying glass fibre mesh of 10 x 10 specification of approved make over tacky surface of first coat of polymer followed by second coat in transverse direction, sprinkling coarse sand over it, followed by protective mechanical cover water proof plaster 20 mm thick after sufficient curing apply IPS 40 mm to 75 mm. thick cement concrete of 1:2:3 proportion using coarse aggregate of 10 MSA and water proofing compound of approved make and polypropylene fibres @ 125 gm per bag of cement making groovr 3 to 4 mm wide & 10 mm deep in concrete, in pannels of 3m/4m or as per site condition & filling the joints with poly sulphide sealant after curing including providing holler with drip moulds at the junction and finishing the concrete surface with neat cement slurry, as directed and ponding the surface as directed etc.complete ; covering 10 years guarantee against leakproofness on court Fee stamp paper of Rs 100/- First Floor |
| 139 | Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. Ground Floor |
| 140 | M Ground Floor |
| 141 | First Floor |
| 142 | M First Floor |
| 143 | Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use) Ground Floor |
| 144 | M Ground Floor |
| 145 | First Floor |
| 146 | M First Floor |
| 147 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Ground Floor |
| 148 | M Ground Floor |
| 149 | First Floor |
| 150 | M First Floor |
| 151 | Providing, drilling and fixing Nipples for pressure injection grouting of polymer cement grout etc. complete. Ground Floor |
| 152 | Filling voids/honeycomb with high pressure injection grouting of Polymer Cement Grout (10% of Polymer by Weight of Cement) Ground Floor |
| 153 | Providing and fixing heavy duty inter locking concrete RUBBER MOULD GLOSSY PAVING BLOCKS of 60 millimeter thickness of having a strength of 400 Kilogram/sq.m of approved quality and shape on a bed of crushed sand of 25 to 30 millimeter thick including striking joints and cleaning etc. complete. (using 100%crushed sand) Ground Floor |
| 154 | Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish Ground Floor |
| 155 | M Ground Floor |
| 156 | First Floor |
| 157 | M First Floor |
| 158 | Providing and laying vitrified stone effect finish tiles having size 590 to 605 mm x 590 to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Ground Floor |
| 159 | M Ground Floor |
| 160 | First Floor |
| 161 | M First Floor |
| 162 | Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. Ground Floor |
| 163 | M Ground Floor |
| 164 | First Floor |
| 165 | Providing and laying handcut polished Kotah Stone flooring 25mm to 30mm thick and 30cm wide in plain/diamond pattern on a bed of 1:6 C.M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Ground Floor |
| 166 | Providing and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size 19 x 19 mm for styles and 15 x15 mm for the top and bottom rails, M.S frame shall have a coat of metel primer of approved make and manufacture. M.S frame shall be covered with heat mouled PVC 'C' channel made from 5 mm (+/0.25) thick prelaminated sheet of density 600 Kilogram/cbm ,of size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side forming stiles ; and 5 mm thick ,95 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered in 45 on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 mm (+/0.25) thick PVC strip of 20 mm width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 mm (+/0.25) thick PVC sheet to be fitted inside the M.S. frame welded/ sealed to the styles and rails with 5 mm (+/0.25) x 30 mm PVC sheet beading on either side and joined together with solvent cement adhesive etc ,10 mm thickness (5 mm (+/0.25) x 2 nos ) 20 mm wide cross PVC sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos M.S.powder coated but hinges of size 100 mm x 25MM x 2mm using 32 mm long steel screws drilled suitable to pass through both the walls of the M.S tube. Other hardwares . Ground Floor |
| 167 | M Ground Floor |
| 168 | First Floor |
| 169 | Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. Ground Floor |
| 170 | M Ground Floor |
| 171 | First Floor |
| 172 | Providing and fixing white european type wall-hung, Size 360mm x 360mm x 575 mm with flush valve having flow rate up to 6.0 Litr/Minute of Jaquar/Cera/Hindware/Perryware or equivalent make including PVC soil pipe, vent pipe upto outside face of wall, 100mm dia PVC plug bend inlet pipe all fittings,cutting & making good walls, floors etc as directed by Engineer in charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) Ground Floor |
| 173 | Providing and fixing white glazed urinal with Pressmatic auto closing valve having flow rate up to 4.0 Litr/Minute of Jaquar/Cera/Hindware /Perryware or equivalent make with P.V.C. waste pipe with fitting arrangement etc.complete as directed by Engineer in charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) Ground Floor |
| 174 | Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black / coloured granite of 180 mm thick stone black kadappa framework including chromium plated coupling bottle - Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etc complete. (Counter size 1.20 m x 0.60 m ) Ground Floor |
| 175 | M Ground Floor |
| 176 | First Floor |
| 177 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements,M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear) Ground Floor |
| 178 | Providing and laying cement concrete flooring 40mm thick with M20 cement concrete laid to proper level and slope in alternate bays, including compaction, filling joints, marking lines to give appearance of tiles of 30cm x 30cm or other size laid diagonally/square etc. finishing smooth (with extra cement) in any colour as directed and Curing etc. complete. With Crushed sand VSI Grade Ground Floor |
| 179 | Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc.complete. Ground Floor |
| 180 | M Ground Floor |
| 181 | First Floor |
| 182 | Mfirst Floor |
| 183 | Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc.complete. Ground Floor |
| 184 | M Ground Floor |
| 185 | First Floor |
| 186 | Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shadeetc. complete. M First Floor |
| 187 | Providing and fixing UPVC Roof made up of 3 layers roofing material of thickness 2mm having width of 1130 mm and of required Length having Tensile strength not less than 330 Kilogram/cm2, including fastening with self drilling screw havingwashers made of stainless steel etc. complete. Ground Floor |
| 188 | Providing , constructing and fixing 600 mm dia. Inspection chamber made up of Polypropylene / polyethylene material Having 315 mm diameter inlet(s)/outlets and with eccentric reducers as per requirement to connect 160 mm and 200 mm pipes having thickness of 5 mm and 600 mm in height, with inbuilt shaft achieve the invert depth as per site condition of wall thickness of 5 mm having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia. Including excavation and refilling the sides of chamber by ?sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc.complete. |
| 189 | Providing and fixing in position various capacity rainwater harvesting dual intensity auto flush open ended at drain outlet filter with working principal of COHESSIVE AND CENTRIFUGAL FORCE having filter element made out of S.S. 304 screen with mesh size of 205 microns having rainfall capacity of 75 m/hr intensity with operating pressure of 0.060Kilogramper sq.cm. of Head with discharge capacity ranging from 10 to 480 lit/min including all necessary accessories like coupler,bends,PVC valve,etc fixing with Bombay nails of required length etc. complete with inlet size of 90 mm to 110 mm diameter from rooftop pipe with drain outlet of 90 mm to 110 mm diameter size with clean water outlet of 62 mm to 90 mm diameter size including fitting and fixing excluding inlet and outlet piping etc complete as per the direction by engineer in charge.(e) FL-500 for the catchment up to 500 sq.m. system size 110 mm diameter inlet, 90 mm diameter clean water outlet, 110 mm diameter drain outlet (filterain,tee,door bend, valve 90mm) |
| 190 | Providing and fixing divertor with overhead shower,shower arm,spout,hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware /Perryware or equivalent make including all necessary pipes,fittings etc.complete as directed by Engineer In Charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) M First Floor |
| 191 | Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. |
| 192 | Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. Ground Floor |
| 193 | M Ground Floor |
| 194 | First Floor |
| 195 | RWH - Recharge PitProviding and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5\\" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300mm thick sidefilling around outside of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10- 25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end- caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge. |
| 196 | Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for thegully trap. |
| 197 | Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) |
| 198 | Providing and fixing Autoclosing pillar cock of pressmatic tap of approved make or equivalent including all fixtures, fittings etc. complete. |
| 199 | Providing , Laying and fixing, jointing Eco Drain 250 mm SN-04 Nu-Drain Upvc pipe or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 & 16098 with fittings such a bends, tees, coupler, etc. jointing with rubber lubricant, including necessary excavation, trench refilling with selective excavated material etc.complete. |
| 200 | Providing , Laying and fixing, jointing Eco Drain 315 mm SN-04 Nu-Drain Upvc pipe or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 & 16098 with fittings such a bends, tees, coupler, etc. jointing with rubber lubricant, including necessary excavation, trench refilling with selective excavated material etc.complete. |
| 201 | Providing , laying and fixing ,jointing Eco- drain 200 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees tees, coupler etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete. |
| 202 | Providing , laying and fixing ,jointing Eco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete. |
| 203 | Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. Ground Floor |
| 204 | M Ground Floor |
| 205 | First Floor |
| 206 | Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/One Running Metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/One Running Metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/One Running Metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With colour Anodising with box. Ground Floor |
| 207 | M Ground Floor |
| 208 | First Floor |
| 209 | Mfirst Floor |
| 210 | Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete. Ground Floor |
| 211 | M Ground Floor |
| 212 | First Floor |
| 213 | M First Floor |
| 214 | Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete . Ground Floor |
| 215 | Solid Core Flush door Single leafProviding and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without door frame).(Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutter Ground Floor |
| 216 | M Ground Floor |
| 217 | First Floor |
| 218 | Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc.complete. Ground Floor |
| 219 | M Ground Floor |
| 220 | First Floor |
| 221 | M First Floor |
| 222 | Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. Ground Floor |
| 223 | M Ground Floor |
| 224 | First Floor |
| 225 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Ground Floor |
| 226 | M Ground Floor |
| 227 | First Floor |
| 228 | Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Ground Floor |
| 229 | M Ground Floor |
| 230 | First Floor |
| 231 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Ground Floor |
| 232 | M Ground Floor |
| 233 | First Floor |
| 234 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Ground Floor |
| 235 | M Ground Floor |
| 236 | First Floor |
| 237 | Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Ground Floor |
| 238 | M Ground Floor |
| 239 | First Floor |
| 240 | Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent,clamps etc. complete. Ground Floor |
| 241 | M Ground Floor |
| 242 | First Floor |
| 243 | Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe andwith necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.Ground Floor |
| 244 | M Ground Floor |
| 245 | First Floor |
| 246 | Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providing T.W.gutties etc. complete. Ground Floor |
| 247 | M Ground Floor |
| 248 | First Floor |
| 249 | Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. Ground Floor |
| 250 | M Ground Floor |
| 251 | First Floor |
| 252 | Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. Ground Floor |
| 253 | M Ground Floor |
| 254 | First Floor |
| 255 | Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. Ground Floor |
| 256 | M Ground Floor |
| 257 | First Floor |
| 258 | Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. Ground Floor |
| 259 | M Ground Floor |
| 260 | First Floor |
| 261 | Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/ union nut complete. Ground Floor |
| 262 | Providing and fixing screw down for 65 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. Ground Floor |
| 263 | Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. First Floor |
| 264 | Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm WithR.C.C. raft in B.C. soil area including cost of reinforcement, 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight 75 mm thick R.C.C. cover medium duty 100Kilogrametc. complete. |
| 265 | Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm WithR.C.C. raft in B.C. soil area including cost of reinforcement, 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight with 75 mm thick R.C.C. cover medium duty 140Kilogrametc. complete. |
| 266 | Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc.complete. |
| 267 | Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.M First Floor |
| 268 | Providing and fixing plain zinc sheeting of 0.80 mm thick (22 B.W.G.) over the ridge hip or valley to galvanized iron sheet roofing including all fastening and bolt galvanised iron screws and bolts, lead and bitumen washers etc. complete.(Weight of 6.8 Kilogram/sq.m.). M Ground Floor |
| 269 | Providing and preparing kitchen otta up to 75 cm width,made up from 30 mm thick and 75 cm high vertical support for kadppa at 1 m. c/c of 25 mm thick both side polished kadappa middle shelf and bottom of 20 mm thick one side polished kadappa with facia patti of 20 x 50 mm kadappa including all material labour cutting fixing with cement mortar and araldite curing polished and cleaning etc. complete. First Floor |
| 270 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. |
| 271 | Providing and fabricating structural steel work in rolled sections, fixed with connecting plates or angle cleats in main and cross beams, hip and jack rafters, purlins connecting to truss members and the like, as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/ bolted/ welded connections and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. |
| 272 | Providing,aupplying,fabricating and fixing panel of aluminium composite panel cladding in approved shape made out of 4 mm thick ACP sheet material consisting of 3mm thick FR grade mineral core following NBC part IV Fire and life safety (having 2 hours fire resistance in accordance to ASTM E119-12 and BS476 part 6 and 7 class O) sandwitched between two aluminium sheets (each 0.5 mm thick of AA 5005/AA3105 grade) The aluminium composite panel cladding sheet shall be coil coated with kynar 500 based PVDF/Lumiflon based fluropolymer resin (having 70:30 ratio of PVDF and acrylic) coating of approved colour and sg=hade on top face and polymer (service) coating of bottom face as specified using stainless steel screws,nuts,bolts,washers,cleats,weather silicon sealent,backer rods etc .overall weight of the ACP shall not be less than 7.5 Kilogram/ One Square Metre) |
| 273 | Providing and fixing Glass mossaic tiles on finished Floor & plain wall surface of size 20mm x20mm x 4mm in all colour, design, fixing in customize design as per direction of Engineer -in-charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer - in -charge. Ground Floor |
| 274 | Machine polishing to cement/marble mosaic tiled flooring or any other type of flooring including cleaning, washing, etc. complete.Ground Floor |
| 275 | Providing and fixing of factory made uPVC Sliding window & door (White Colour) complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPaAll corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use d).2 )Track 2 / 4 Sash (Big Series) door frame of size 67 x 54 mm & Sash of size 85 x 47 mm. M Ground Floor |
| 276 | First Floor |
| 277 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, madewith 40mm dia M.S. tube, placed 1.5 metre centre to centre,horizontal & vertical tubes joint with cup & lock system with M.S. Tubes,M.S. tube challis,M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations withessential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for paymentpurpose. (2) The payment will be made once only for execution of all items for such works.Second Floor |
| 278 | Third Floor |
| 279 | Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate) First Floor |
| 280 | Second Floor |
| 281 | Third Floor |
| 282 | Fourth Floor |
| 283 | Providing & Fixing in position Structural glazing consisting of main frame of powder coated jindal or euivalent make aluminum curain wall section 48 x 64 mm & slab frame of 20x25x2mm poder coated aluminum SHS by using structural silicon of Dow Coring 995 weather sillicon coiring 785, spacer tape 6mm x6mm including glass & labour etc. complete.Ground Floor |
| 284 | Providing and installation of GFRC ( Facades ) (✓ Thickness 50 MM ✓ ALKALI RESISTANT GLASSFIBRE , WHITE CEMENT, SILICA SAND , POLYMER & ADMIXTURE ✓IINCLUDING MS STEEL SUPPORT FRAMING including necessary fixtures and fastenings etc complete as directed by Engineer Incharge. Ground Floor |
| 285 | Aluminium vertical louvers are fixed or adjustable fins for ventilation, sun control, and aesthetics, mounted onto a frame attached to a wall or substrate using fastener. securing a base frame to the structure with fasteners and then attaching individual louver blades to the frame, often using profiles. |
| 286 | Prefabrication insulated roofing sheet.Providing & fixing Roof will be made in 50/80mm thick insulated PUF Panel of PPGI sheet 0.4mm on both side of PU |
| 287 | Providing and applying external raincoat painting with crack filling acrylic polymer based chemical compound coating to the external surface of walls to prevent water seepage in the masonry walls during monsoon added with required shade Steiner to give required shade to the surface in two coats. Including providing three coat of priming of polymer base primer including preparing surface scrapping the existing loose old paint, removing loose particles of sand on the surface opening and cleaning the cracks developed in the external plaster, removing loose particles by chiseling, filling cracks by chemicals compound of approved make with proper penetration etc. Coating of Raincoat with the help of brush and as per instructions and specification given by manufacturer and with instruction from Engineer in- charge. Work shall be executed by certified applicator only and covering gurantee of 3 years on court stamp paper of Rs. 500/- and necessary testing etc. complete. |
| 288 | Providing & Fitting LED Bank name boards at different area or sections of the building, including Scafolding & neccesary fitting etc. complete. ACP LED BOARD |
| 289 | Providing & Fitting LED Bank name boards at different area or sections of the building, including Scafolding & neccesary fitting etc. complete.ACP LED POLE 3X3 D. SIDED lolipop |
| 290 | Providing & Fitting LED Bank name boards at different area or sections of the building, including Scafolding & neccesary fitting etc. complete.ACP LETTER FLF BOARD |
| 291 | Empty boring for 325 to 400 mm dia bored R.C.C. cast in situ piles including withdrawal of shell, removal of earth to a distance of 50 metres etc. complete.Spec :(As directed by Engineer in Charge) |
| 292 | Providing and laying cast in situ / Ready Mix Cement Concrete M-20 RCCsingle rim bored pile of 225 mm dia. each of load capacity as per design and of specified diameter of pile and bulb as directed, sunk to the required depth through all strata except rock, excluding provision of reinforcement including placing with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) by tremie arrangement, compaction of concrete including chipping and dressing including chipping and dressing if required etc. complete. (Excluding steel reinforcement) |
| 293 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap metal forR.C.C. pile caps as per detailed designs and drawings, including bailing out water manually, centering, formwork, laying/ pumping, compacting, finishing and curing etc. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.with Crushed sand VSI Grade/V.S.I. quality Artificial Sand, complete. (Excluding steel reinforcement) |
| 294 | Providing expansion joints in R.C.C. framed structure (exterior Columns) with plain premoulded filler 25 mm thick and 3 mm thick alluminium plate, hold fast, fixing T.W. battens on internal face, finishing etc. complete as directed. |
| 295 | Providing and fixing bituminous pad 25mm thick for expansion joints in retaining wall, compound wall etc. complete. |
| 296 | Providing and fixing mild steel grill gate with angle iron frame 65mm x 65mm x 10mm with iron bars at 150mm C/C and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kilogram/Smt. |
| 297 | Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete. |
| 298 | Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camberand side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking asdirected. |
| 299 | Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils. |
| 300 | Construction of granular sub-base by providing close graded Material,mixing in a mechanical mix plant at OMC, carriage of mixed Material towork site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve thedesired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material |
| 301 | Providing and laying in situ / ready mix / ready mix M10 cement concrete of trap/ granite/ quartzite/ gneiss metal in foundationincluding necessary centering, formwork, bailing out water,compacting and curing etc. complete. (with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer) with natural /artifical sand) |
| 302 | Providing and laying in situ/ readymixM-25 controlled reinforced cement concreteof trap metal for raft slab including\\"V\\" haunches,formwork, scaffolding, compaction by vibrating, finishing curingetc.complete.concrete batch mix plant/panmixer with fine agreegates of required specifications ( VSI sand finely washed etc ) etc.complete. (excluding reinforcement).a)CC Grade with reversible drum type mixer/concrete batchmix plant (pan mixer) . |
| 303 | Providing and laying in situ / ready mix M20 RCC of trap/ granite/ quartzite/ gneiss metal for RCC work of ballast walls, kerbs and box returns including scaffolding, compaction, formwork finishing and curing etc. complete. (excluding reinforcement, with fully automatic micro processor based PLC with SCADA enabled concrete batch mix plant / pan mixer with fine agreegates of required specifications ( VSI sand finely washed etc ) RCC work of Ballast walls & Kerb |
| 304 | Providing,cutting,bending,hooking, tying and laying in position TMT FE500 steel bars for reinforcement for all RCC works as per detailed drawings etc. complete. |
| 305 | Providing and fixing heavy duty inter locking concrete Rubber mould glossy paving blocks of 80 mm thickness of having a strength of 400 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting jointsand cleaning etc. complete. (using 100% crushed sand) |
| 306 | Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. |
| 307 | Providing and laying in situ/ready mix controlled grade of M25 of trap/granite /quartzite/gneiss metal for RCC works in cut off walls/curtain walls including necessary scaffolding,centering, compacting by vibrator,finishing and curing etc .complete. (with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/concrete batch mix plant(pan mixer with fine agreegates of required specifications (VSI sand finely washed etc ), excluding reinforcement) |
| 308 | Providingand layingin situ / readymixM-25 controlled cement concreteof trap/ granite/quartzite/gneissmetal forRCCwork in solid/deck slab etc. including ramming,vibrating,curing, formwork,centeringand finishing in cement plaster excluding reinforcementetc.complete.(with fully automatic microprocessor based PLC with SCADA enabled concrete batch mix plant / panmixer and fine agreegates of required specifications ( VSI sand finely washed etc ) |
| 309 | Providing and fixing Ductile iron Man Hole Covers/ Strom Water Grating and Grating with frame of Various sizes, weight and types and load bearing capacity as per EN-124, equivalent NECO with prior approval of concerned Superitending Engineer. |
| 310 | Yield Testing of borewells using90\\" 'V' Notch by air lift method for Half hours for successful borewell as per yielidng Borewell and installation. Yield testing of Borewell using 80\\"V' |
| 311 | Driling of 150mm diameter Inwell vertical bore including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. |
| 312 | Providing casing pipe welded threaded joints medium class ERW Mild Steel block as per ISI 1239 specifications with socket and inserting in Tube well through over burden including transportation to site cutting threading & grouting the sand with cement slurry including in the cost of the coupling and plugs of 4.8mm thick etc. complete 200mm dia perforated. providing casing pipe welded threaded joints.200 mm |
| 313 | Providing and laying in trenches 80 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes of 10.15 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 314 | Providing double flange sluice valve confirming for IS- 14846 including worn geararrangements as per test pressure, stainlesssteel spindle, caps, including inspectioncharges, transportation upto departmentalstore, unloading, stacking excluding GSTlevied by GOI & GOM in all respect etc.complete. Dia 80mm |
| 315 | Providing and supplying ISI mark CI D/F refluxvalves (non-return valves ) of following diaincluding railway freight, inspection charges,unloading from railway wagon, loading intotruck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GO Main all respect etc.complete. Reflux valves as per I.S.5312 Part (1984) Dia 80mm |
| 316 | Pedestal Unit @ 420Lx450Dx650HTProviding & Fixing of PEDESTAL @ 420Lx450Dx650HT :- To be made out of Complete Membrane consist of three Drawers as per drawing.First Floor |
| 317 | Pedestal Unit @ 420Lx450Dx650HTProviding & Fixing of PEDESTAL @ 420Lx450Dx650HT :- To be made out of Complete Membrane consist of three Drawers as per drawing.M First Floor |
| 318 | Conference Table @ 3600Lx1400Dx750HTProviding & Fixing of Main Table @ 3600Lx1400Dx750HT - made up of 18+18mm Thick MDF top with PVC Membrane finish and waterfall edge profile. Aluminium Anodizied finish beeding of 4mm thich is running all over the table top edge. Gable ends is Aerofoiled Shape with front edges in PVC Membrane finish and rest in Prelaminated MDF with batton structure. Gable ends should be hollow from inside for the provision of passing electrical and Data wiring. , MODESTY PANEL:- to be made of 18 mm thick Prelaminated particle board with PVC edge band Access Flap:- For Wire manager 2 Nos.Ground Floor |
| 319 | Conference Table @ 3600Lx1400Dx750HTProviding & Fixing of Main Table @ 3600Lx1400Dx750HT - made up of 18+18mm Thick MDF top with PVC Membrane finish and waterfall edge profile. Aluminium Anodizied finish beeding of 4mm thich is running all over the table top edge. Gable ends is Aerofoiled Shape with front edges in PVC Membrane finish and rest in Prelaminated MDF with batton structure. Gable ends should be hollow from inside for the provision of passing electrical and Data wiring. , MODESTY PANEL:- to be made of 18 mm thick Prelaminated particle board with PVC edge band Access Flap:- For Wire manager 2 Nos.First Floor |
| 320 | Conference Table @ 3600Lx1400Dx750HTProviding & Fixing of Main Table @ 3600Lx1400Dx750HT - made up of 18+18mm Thick MDF top with PVC Membrane finish and waterfall edge profile. Aluminium Anodizied finish beeding of 4mm thich is running all over the table top edge. Gable ends is Aerofoiled Shape with front edges in PVC Membrane finish and rest in Prelaminated MDF with batton structure. Gable ends should be hollow from inside for the provision of passing electrical and Data wiring. , MODESTY PANEL:- to be made of 18 mm thick Prelaminated particle board with PVC edge band Access Flap:- For Wire manager 2 Nos.M First Floor |
| 321 | 3 DRAWER PEDESTAL UNIT @ 392L x 450D x 680Ht. mm.3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. 3 Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board. M Ground Floor |
| 322 | Multiple Compartment Lockers @ 1140Lx 457D x 1830 mm. Ht.Providing and fixing Multiple Compartment Lockers @ 1140Lx 457D x 1830 mm. Ht. with 12 Compartments , Complete body & shutter made of CRCA Sheet with powder coated finish as per approved color. |
| 323 | Multiple Compartment Lockers @ 1140Lx 457D x 1830 mm. Ht.Providing and fixing Multiple Compartment Lockers @ 1140Lx 457D x 1830 mm. Ht. with 12 Compartments , Complete body & shutter made of CRCA Sheet with powder coated finish as per approved color.First Floor |
| 324 | Book Case with Glass Shutter @ 825Lx300Dx1650HTProviding & Fixing of Book Case with Glass Shutter @ 825Lx300Dx1650HT:- To be made out of complete body & in 0.7mm thick CRCA & Shutter in 1.2mm thick CRCA with glass pannel in Powder coating finish as per drawing. |
| 325 | Providing & Arrangemnt of High Back Chair - TILT MECHANISM WITH MULTILOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U.CASTORS GASLIFT FOR HEIGHT ADJUSTMENT. |
| 326 | Providing & Arrangemnt of High Back Chair - TILT MECHANISM WITH MULTILOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U.CASTORS GASLIFT FOR HEIGHT ADJUSTMENT. First Floor |
| 327 | Providing & Arrangemnt of High Back Chair - TILT MECHANISM WITH MULTILOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U.CASTORS GASLIFT FOR HEIGHT ADJUSTMENT. M First Floor |
| 328 | Providing & Arrangemnt of Mid Back, ECO CTS Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric Upholstery |
| 329 | Providing & Arrangemnt of Mid Back, ECO CTS Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric Upholstery M Ground Floor |
| 330 | Providing & Arrangemnt of Mid Back, ECO CTS Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric Upholstery First Floor |
| 331 | Providing & Arrangemnt of Mid Back, ECO CTS Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric Upholstery M First Floor |
| 332 | Conference Table @ 1800 x 900 x 750 mm Ht.Providing & Fixing of Main Table @ 1800Lx900Dx750HT - made up of 18+18mm Thick MDF top with PVC Membrane finish and waterfall edge profile. Aluminium Anodizied finish beeding of 4mm thich is running all over the table top edge. Gable ends is Aerofoiled Shape with front edges in PVC Membrane finish and rest in Prelaminated MDF with batton structure. Gable ends should be hollow from inside for the provision of passing electrical and Data wiring. , MODESTY PANEL:- to be made of 18 mm thick Prelaminated particle board with PVC edge band Access Flap:- For Wire manager 1 Nos.M Ground Floor |
| 333 | Conference Table @ 1800 x 900 x 750 mm Ht.Providing & Fixing of Main Table @ 1800Lx900Dx750HT - made up of 18+18mm Thick MDF top with PVC Membrane finish and waterfall edge profile. Aluminium Anodizied finish beeding of 4mm thich is running all over the table top edge. Gable ends is Aerofoiled Shape with front edges in PVC Membrane finish and rest in Prelaminated MDF with batton structure. Gable ends should be hollow from inside for the provision of passing electrical and Data wiring. , MODESTY PANEL:- to be made of 18 mm thick Prelaminated particle board with PVC edge band Access Flap:- For Wire manager 1 Nos.First Floor |
| 334 | Providing and Fixing Vertical Blinds of approved Make and shade of 100mm regular fabric with powder coated aluminium channel with telting PVC chain & bottom weight plate with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work) |
| 335 | Providing and Fixing Vertical Blinds of approved Make and shade of 100mm regular fabric with powder coated aluminium channel with telting PVC chain & bottom weight plate with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work) M Ground Floor |
| 336 | Providing and Fixing Vertical Blinds of approved Make and shade of 100mm regular fabric with powder coated aluminium channel with telting PVC chain & bottom weight plate with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work) First Floor |
| 337 | Supply ,installation and commissioning of Filter Diameter -1200 mm ,Bobbin Wound Reinforced Fiberglass Mount Sand Filters ( with bolt type valve)Maximum Flow Rate: 52800 Litres/Hr Size Dia: 1200mmValve dia: 75 mm |
| 338 | Supply ,installation and commissioning ofModel: EPH400 Super Power Series Pump 4HP, 440V/50Hz,Three phase,Class F 3\\" Flange, IPx5 Waterproof standard, Ring Lock design, S S 316 Shaft & Mechanical Seal |
| 339 | Supply ,installation and commissioning ofOzo-Plus Ozone Generator 8g/h, 30 l/m |
| 340 | Supply ,installation and commissioning ofModel : CLL-75 Chemical Feeder 11KG In-line Capacity : 10PPM for 95000L Pool Valve dia: 63 mm |
| 341 | Supply ,installation and fixing of EM2861floor inlet of dia 2 inch connection-Having flow rate of 200 L/ min.MOC-ABS |
| 342 | Supply ,installation and fixing of EM281212\\" x 12\\" Main drain cover -Having flow rate of 558 L/min .MOC-ABS |
| 343 | Supply ,installation and fixing of EM 2822Vacuum Point of dia 2 inch connection- Having flow rate of 150 L/min |
| 344 | Supply ,installation and fixing of Stainless steel AISI-304 Mixed ladders with handrails with standard model step, added top double safety tread, width: 500mm, handrails dia 43mm stainless steel non-slip steps, provided with electrical earthing connection and anchoring fixtures. OF 315 3 step ladder(Stainless Steel Ladder Anchor Type) |
| 345 | Supply ,installation and fixing of Stainless steel AISI-304 Mixed ladders with handrails with standard model step, added top double safety tread, width: 500mm, handrails dia 43mm stainless steel non-slip steps, provided with electrical earthing connection and anchoring fixtures. OF 415 4 step ladder(Stainless Steel Ladder Anchor Type) |
| 346 | Supply ,installation and fixing of Stainless steel AISI-304 Mixed ladders with handrails with standard model step, added top double safety tread, width: 500mm, handrails dia 43mm stainless steel non-slip steps, provided with electrical earthing connection and anchoring fixtures.OF 515 5 step ladder(Stainless Steel Ladder Anchor Type) |
| 347 | Supply ,installation and fixing of LED-CP 100Round Plastic Light, 102 LEDs 6W/12V White |
| 348 | Supply ,installation and fixing of EM2823CUnterwater Light Junction Box |
| 349 | Supply ,installation and fixing of TRA-300VA-12V/300VA,230V-240V/50HZ Transformer for led Lights |
| 350 | Supply of Standard Leaf Rake of high quality PP an Nylon,designed to be attached to a telescopic pole |
| 351 | Supply of Telescopic Aluminium pole2 x 4m constructed of premiun rxtruded 1.2 mm aluminium tubing with grip+lock |
| 352 | Supply of Flexible vacuum hose 38mm*15m .A high quality heavy duty durable construction UV protected and abrasion resistant. |
| 353 | Supply of 18\\" curved wall brush made of hard wearing ABS and PP, Designed to attached with telescopic pole. |
| 354 | Supply of Vacuum head 18\\" length Aluminium body designed for robust use. |
| 355 | Supply and installation of 250 mm UltraViolet Resistant Gratings for channel, MOC-PP. |
| 356 | Supply and installation of Sand Media (Filter Media)FINE SAND (0.5 MM TO 1.5 MM)MEDIUM SAND (3 MM TO 5 MM) |
| 357 | Pipes, Valves and Fittings. ASTRAL make for Pipes and fittings and valves (UPVC PIPE) |
| 358 | Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 20cms.( consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.38a) |
| 359 | Supplying on site well decomposed Farm Yard Manure for excavation area of depth of 20 cms.( consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.38b) |
| 360 | Providing on site well established (free from weeds /diesease etc.) ready to fix lawn turf in slabs/ rolls of required variety as directed .(As per P&G DSR 2022-23 Items of garden work,Sr No.14, item no 2) |
| 361 | Providing on site required variety of Shrubs (free from weeds /diesease etc.) 30 cms. apart c/c.Name:-Murraya(Kamini);Bag Size 7'' x 8\\"(plants list) 1(a) serial no 15. |
| 362 | Providing on site required variety of HedgesWell Developed, Healthy Foliage / Half Bloom Stage , Free from Pest and Diseases. apart c/c.Name:-Bougavillae Thema ;Bag Size 8'' x 10\\"(plants list) 7(b) serial no 10. |
| 363 | Excavation for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs.for a depth of 20 cms.(As per P&G DSR 2022- 23 Items of garden work,Sr No.5) |
| 364 | Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 20 cms. for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed/ ground cover. (1/10 of semiskilledlabour)(As per P&G DSR 2022-23 Items of garden work,Sr No.23) |
| 365 | Maintainance of Newly Developed lawn(Instant Lawn) Area. For First 30 daysOnly (As per P&G DSR 2022-23 Items of garden work,Sr No.29) |
| 366 | Maintainance of Newly Developed ShrubsArea. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Sr No.31) |
| 367 | Supplying on site fresh Garden soil (i. e. 3 part soil ) (free from stones rubbish like dried grass roots, other such materials) for excavated pit size area of 1 x 1 x 1m ( consolidated thickness).Quantity of soil 0.653 cum x 800/cum = 522.40/-.(As per P&G DSR 2022-23 Items of garden work,Sr No.45a) |
| 368 | Supplying on site fresh Garden soil (i. e. 3 part soil ) (free from stones rubbish like dried grass roots, other such materials) for excavated pit size area of 0.45 x 0.45 x 0.45m ( consolidated thickness).Quantity of soil 0.079 cum x 800/cum = 63.20/-.(As per P&G DSR 2022-23 Items of garden work,Sr No.43a) |
| 369 | Supplying on site well decomposed Farm Yard Manure FYM (i. e. 1 part FYM) for excavated pit size area of 0.45 x 0.45 x 0.45m. ( consolidated thickness).Quantity of FYM 0.203 cum x 950/cum = 21.85/-.(As per P&G DSR 2022-23 Items of garden work,Sr No.45b) |
| 370 | Providing on site Flowering Shrubs Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-HAMELIA PATENS ;Bag Size 8 x10'', ht 45- 60CM (plants list sr no1 ( b) , item no 6 Page no -16) |
| 371 | Providing on site Flowering Shrubs Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-hibiscus ;Bag Size 8 x10'', ht 45- 60CM (plants list sr no1 ( b) , item no 7 Page no -16) |
| 372 | Providing on site Flowering Shrubs Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-IXORA MINI ;Bag Size 8 x10'', ht 45- 60CM (plants list sr no1 ( b) , item no 8 Page no -16) |
| 373 | Providing on site Flowering Shrubs Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Jatropha ;Bag Size 8 x10'', ht 45- 60CM (plants list sr no1 ( b) , item no 12 Page no -16) |
| 374 | Providing on site Flowering Shrubs Specification:-Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Mogara/Jasminum ;Bag Size 9 x11'', ht 20- 45 CM (plants list sr no1 ( b) , item no 14 Page no -16) |
| 375 | Providing on site Flowering Shrubs Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Murraya/ Kamini ;Bag Size 9 x11'', ht 20- 45 CM (plants list sr no1 ( b) , item no 15 Page no -16) |
| 376 | Providing on site Flowering Shrubs Specification:-Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Ratrani/ Night queen ;Bag Size 8 x 10'', ht 45- 60 CM (plants list sr no1 ( b) , item no 19 Page no -16) |
| 377 | Providing on site Flowering Shrubs Specification:-Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Russelia ;Bag Size 8 x 10'', ht 30- 45 CM (plants list sr no1 ( b) , item no 23 Page no -16) |
| 378 | Providing on site Flowering Shrubs Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Tagar Variegated ;Bag Size 10 x 10'', ht 30- 65 CM (plants list sr no1 ( b) , item no 25 Page no -17) |
| 379 | Providing on site Flowering Shrubs Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Tecoma capensis ;Bag Size 10 x 10'', ht 30- 65 CM (plants list sr no1 ( b) , item no 26 Page no -17) |
| 380 | Providing on site Flowering Shrubs Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Tecoma capensis ;Bag Size 10 x 10'', ht 30- 65 CM (plants list sr no1 ( b) , item no 26 Page no -17) |
| 381 | Providing on site Foliage Shrubs Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Alpinia ;Bag Size 13 x 13'', ht 30- 60 CM (plants list sr no 2 ( b) , item no 2 Page no -18) |
| 382 | Providing on site Foliage Shrubs Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Aralia ;Bag Size 13 x 13'', ht 30- 60 CM (plants list sr no2 ( b) , item no 3 Page no -18) |
| 383 | Providing on site Foliage Shrubs Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Cordyline ;Bag Size 13 x 13'', ht 30- 60 CM (plants list sr no2 ( b) , item no 5 Page no -18) |
| 384 | Providing on site Foliage Shrubs Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Cyperus Golden ;Bag Size 18 x 18'', ht 90- 120 CM (plants list sr no2 ( b) , item no 8 Page no -18) |
| 385 | Providing on site Foliage Shrubs Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Diffenbachia ;Bag Size 13 x 13'', ht 45- 60 CM (plants list sr no2 ( b) , item no 10 Page no -18) |
| 386 | Providing on site Foliage Shrubs Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Facus Golden ;Bag Size 13 x 13'', ht 45- 60 CM (plants list sr no2 ( b) , item no 15 Page no -19) |
| 387 | Providing on site Foliage Shrubs Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Facus Safari ;Bag Size 13 x 13'', ht 45- 60 CM (plants list sr no2 ( b) , item no 18 Page no -19) |
| 388 | Providing on site Foliage Shrubs Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Mayurpankhi/ Thuja ;Bag Size 13 x 13'', ht 45- 60 CM (plants list sr no2 ( b) , item no 21 Page no -19) |
| 389 | Providing on site Foliage Shrubs Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Pisonia alba ;Bag Size 10 x 10'', ht 30- 45 CM (plants list sr no2 ( b) , item no 22 Page no -19) |
| 390 | Providing on site Flowering Climbers and creepers Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Allamanda (allamanda cathertica) ;Bag Size 7 x 8'', ht 15- 30 CM (plants list sr no 3 , item no 2 Page no -19) |
| 391 | Providing on site Flowering Climbers and creepers Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Kunda ( Jasminum Multiflorum) ;Bag Size 7 x 8'', ht 15- 30 CM (plants list sr no 3 , item no 6 Page no -19) |
| 392 | Providing on site Flowering Climbers and creepers Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Jui ( Jasminum officinale) ;Bag Size 7 x 8'', ht 15- 30 CM (plants list sr no 3 , item no 7 Page no -19) |
| 393 | Providing on site Flowering Climbers and creepers Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Passionflower (Passiflora blue) ;Bag Size 7 x 8'', ht 15- 30 CM (plants list sr no 3 , item no 9 Page no -19) |
| 394 | Providing on siteBalbous / Rhizomatous plants Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Dahlia ;Bag Size 7 x 8'', ht 30- 45 CM (plants list sr no 4 , item no 4 Page no -20) |
| 395 | Providing on siteBalbous / Rhizomatous plants Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Lilium sp. ;Bag Size 7 x 8'', ht 30- 45 CM (plants list sr no 4 , item no 6 Page no -20) |
| 396 | Providing on siteBalbous / Rhizomatous plants Specification:- Well Developed, Fresh, Healthy half in bloom, Free from pest and disease Name:-Chrysanthemum ;Bag Size 7 x 8'', ht 30- 45 CM (plants list sr no 4 , item no 10 Page no -20) |
| 397 | Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Bahva (Amaltash);Bag Size 18 x18'', ht 8- 10'(plants list sr no 5C, item no 1 Page no -22) |
| 398 | Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Bakul ;Bag Size 18 x18'', ht 8- 10'(plants list sr no 5C, item no 2 Page no -22) |
| 399 | Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Gulmohar ;Bag Size 18 x18'', ht 8- 10'(plants list sr no 5C, item no 4 Page no -22) |
| 400 | Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Kadamb;Bag Size 18 x18'', ht 8- 10'(plants list sr no 5C, item no 5 Page no -22) |
| 401 | Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Kanchan;Bag Size 18 x18'', ht 8- 10'(plants list sr no 5C, item no 6 Page no -22) |
| 402 | Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Largesstroemea ;Bag Size 18 x18'', ht 8- 10'(plants list sr no 5C, item no 7 Page no -22) |
| 403 | Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-RAIN TREE ;Bag Size 18 x18'', ht 8- 10'(plants list sr no 5C, item no 9 Page no -22) |
| 404 | Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-SHITA ASHOK ;Bag Size 18 x18'', ht 8- 10'(plants list sr no 5C, item no 10 Page no -22) |
| 405 | Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-SPATHODIA ;Bag Size 18 x18'', ht 8- 10'(plants list sr no 5C, item no 12 Page no -22) |
| 406 | Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Nilmohar ;Bag Size 18 x18'', ht 8- 10'(plants list sr no 5C, item no 8 Page no -22) |
| 407 | Providing on site Foliage Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged.. Apart c/c.Name:-Arjuna ;Bag Size 18 x18'', ht 8- 10'(plants list sr no 6C, item no 3 Page no -24) |
| 408 | Providing on site Foliage Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged.. Apart c/c.Name:-Deshi Badam ;Bag Size 18 x18'', ht 8- 10'(plants list sr no 6C, item no 4 Page no -24) |
| 409 | Providing on site Foliage Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged.. Apart c/c.Name:-Drooping Ashok ;Bag Size 18 x18'', ht 8- 10'(plants list sr no 6C, item no 5 Page no -24) |
| 410 | Providing on site HEDGES Specification:- Well developed, healthy Foliage/ Half bloom stage, free from pest and diseases .Name:-Bougavillae Thema ;Bag Size 18 x18'', ht 60cm to 75 cm (plants list sr no 7d, item no 2 Page no -26) |
| 411 | Providing on site HEDGES Specification:- Well developed, healthy Foliage/ Half bloom stage, free from pest and diseases .Name:-Bougavillae Glabra;Bag Size 13 x13'', ht 60cm to 75 cm (plants list sr no 7d, item no 3 Page no -26) |
| 412 | Providing on site Ground Cover Specification:- Well developed, healthy, free from pest and diseases .Name:-Asparagus ;Bag Size 7 x8'', ht 10cm to 20 cm (plants list sr no 8, item no 3 Page no -26) |
| 413 | Providing on site PalmsSpecification:- Palm should be well Developed,Good Branching ,healthy Condition,appropriate Size in Polybag,undamaged... Apart c/c.Name:-Areca Palm ;Bag Size 18 x18'', ht 8- 10'(plants list sr no1,item no 11d) |
| 414 | Providing on site PalmsSpecification:- Palm should be well Developed,Good Branching ,healthy Condition,appropriate Size in Polybag,undamaged... Apart c/c.Name:-Fox tail palm;Bag Size 18 x18'', ht 8- 10'(plants list sr no3,item no 11d) |
| 415 | Providing and Supplying Cement Pot size 36 Inch x 18 inch x 18 Inch of good quality, Durable well finish on edge with good strength |
| 416 | Excavation pit size 1.00 x1.00 x 1.00m for planting large flowering/ shady trees (plant height 2 to 4 mtr.)/ palm varieties of height (plant height 2 to 4 mtr.) inearth, soil of all types, soft murum, including removing the excavated & unwanted material up to a required distance of 50 mtrs. (As per P&G DSR 2022-23 Items of garden work,Sr No.12) |
| 417 | Excavation pit size 0.45 x 0.45 x 0.45 m for plantingearth, soil of all types, soft murum, including removing the excavated & unwanted material up to a required distance of 50 mtrs. (As per P&G DSR 2022-23 Items of garden work,Sr No.10) |
| 418 | Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species as directed etc. complete for required pit size 1.00 x 1.00 x 1.00m.(1/10 of semiskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.27) |
| 419 | Maintainance of Newly Planted tree varities having height 2mtr. - 4mtr. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Srs No.35) |
| 420 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 421 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specificationNo. WG-MA/CC. |
| 422 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. With necessary accessories in wall/floor with chiselling appropriately as perspecification No: WG-MA/CC. |
| 423 | Supplying and laying HMS PVC conduit FRLS grade 32mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specificationNo. WG-MA/CC. |
| 424 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or anyother places as per specification No: WG-MA/BW |
| 425 | Supplying & erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/ BW |
| 426 | Supplying and erecting mains with 2x2.5 sq.mmFRLSH copper PVC insulated wire laid in providedconduit/trunking/inside pole/Bus bars or any otherplaces. as per specification No: WG-MA/BW |
| 427 | Supplying & erecting mains with 1x2.5 sq.mmFRLSH copper PVC insulated wire laid in providedconduit/trunking/inside pole/Bus bars or any otherplaces. as per specification No: WGMA/BW (ForEarth- green color) |
| 428 | Supplying and erecting mains with 4x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 429 | Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 430 | Supplying and erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 431 | Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 432 | Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or anyother places as per specification No: WG-MA/BW |
| 433 | Supplying and erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 434 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 435 | Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 436 | Supplying and erecting modular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete. |
| 437 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections |
| 438 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connectionscomplete. |
| 439 | Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete. |
| 440 | Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connectionscomplete. |
| 441 | Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 442 | Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 443 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background. |
| 444 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background. |
| 445 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background. |
| 446 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background. |
| 447 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background. |
| 448 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background. |
| 449 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modula type switch, earthing and required accessories as per specification No: WGPW/ CW |
| 450 | Point wiring for light/bell/exhaust fan in minimum 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW |
| 451 | Point wiring for light/bell/exhaust fan in minimum 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW |
| 452 | Point wiring for light/bell hybrid type (surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm HMS PVCconduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification no. WG-HW |
| 453 | Point wiring for ceiling fan hybrid type (surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm HMS PVCconduit / casing n caping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification no. WG-HW |
| 454 | Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH gradecopper wires with required accessories as per specification No: WG-PW/CW |
| 455 | Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/ CW |
| 456 | Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 457 | Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG- 11 as per specification No. WG-TW |
| 458 | Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser havingsystem lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mountingarrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 459 | Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mountingarrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 460 | Supplying and erecting LED square / circular Max. 20 W down lighter / Panel Light having pressure die-cast aluminium housing, polystyrene diffuserhaving system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. |
| 461 | Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having systemlumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f.>0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement withboard for surface type or spring loaded mounting clips complete with 3 yearswarranty. |
| 462 | Supplying and erecting integrated LED Highbay Fitting 100W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser withintegrated optics, having system lumens output of Min. 15000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90,operating range of 140-240V, inbuilt surge protection of 4 kV, Life class of 0,000 Hrs at L50B50 , including driver complete with 2 Year warranty as perspecification No. FG-ODF/LED |
| 463 | Supplying and erecting integrated LED Highbay Fitting 135W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser withintegrated optics, having system lumens output of Min. 20000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90,operating range of 140-240V, inbuilt surge protection of 4kV, Life class of 50,000 Hrs at L50B50 , including driver complete with 2 Year warranty as perspecification No. FG-ODF/LED. |
| 464 | Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. |
| 465 | Supplying and erecting Energy Saving Ceiling fan of 3 star rating as per BEE 230 V A.C. 50 cycles 1200 mm complete erected in position as per specificationno. FG-FN/CF |
| 466 | Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. |
| 467 | Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copperPVC wire. |
| 468 | Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B- 22/E-27 base as per specification no. FG-LP. |
| 469 | Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumensoutput of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 470 | Supplying, erecting, testing and commissioning of20kVA capacity online pure sine wave, with backuptime of ....... hrs. PWM & IGBT based UPS with 0.9to unity output pf, 3 phase input and 3 phase output complete with all protectionsas per specification no.AP-UPS |
| 471 | Supplying and erecting 12 V/65Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete |
| 472 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB |
| 473 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB |
| 474 | Supplying, erecting & marking SPMCB 6A to 32A, D-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB |
| 475 | Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specificationno. SW-SWR/MCB |
| 476 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specificationno. SW-SWR/MCB |
| 477 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specificationno. SW-SWR/MCB |
| 478 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 479 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 480 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on provided iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 481 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on provided iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 482 | Providing & erecting 3 Pole MCCB, 415V, up to 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB |
| 483 | Supplying, fixing and commissioning 4 pole RCBO up to 25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indications per specification no SW-RCBO. |
| 484 | Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO |
| 485 | Supplying, fixing and commissioning 4 pole RCBO 63A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO |
| 486 | Supplying, fixing and commissioning 2 pole RCBO up to 25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCBO. |
| 487 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 25 sq. mm. aluminiumconductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 488 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 489 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 70 sq. mm. aluminiumconductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 490 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 491 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 492 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 493 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 494 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 495 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 496 | Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 25 to 50 sq mm., with necessary material as perspecification No. CB-JT/LT |
| 497 | Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 70 to 120 sq mm., with necessary material as perspecification No. CB-JT/LT |
| 498 | Supply, installing, and testing of maintenance free earthing comprising of electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with Carbon based environment friendly back fill ground enhancing compound required to fill up theexcavated earth with required quantity (min. 125kg) complete, and recording theresults specification no. EA-MF |
| 499 | Supplying and erecting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint in an approved manner with joints required. as per specification No (EA-EP). |
| 500 | Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP. |
| 501 | Supplying and installing FR PVC sheathed HDPE insulated copper cat-6 cable suitable for networking compliant with ANSI/TIA-568.2-D standards inprovided conduit/casing-n-capping as per specification no. WG-ELVC/NC |
| 502 | Supplying, erecting, testing & commisioning metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc.including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and painted with one coat of red lead paint and 2 coats of enamel paintor powder coating complete as per specification no. CP/SH/CR |
| 503 | Supplying and erecting iron work, sheet metal work consisting of MS sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc.for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted withone coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the site engineer. |
| 504 | Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operateon 500V having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 505 | Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable tooperate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panelcomplete with calibration certificate from manufacturer. |
| 506 | Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box/panel and duly connecting with necessary PVC wire leads and lugs. |
| 507 | Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc. |
| 508 | Supplying & erecting LED type indicating pilot lamp with LED colours Blue, 230 / 250V on provided box / panel with necessary material, wiring & connections etc. |
| 509 | Supplying, erecting, testing & commisioning LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCAbox duly secured with insulating materials connected to the meter with test certificates. |
| 510 | Providing & erecting 4 Pole MCCB, 415V, 160A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no lineload bias in provided enclosure/panel as per specification no. SW-MCCB(125A MCCB) |
| 511 | Providing & erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting andadjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB |
| 512 | Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting andadjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 513 | Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting andadjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 514 | Supplying and erecting ON LOAD four pole automatic transfer switch, 415V, 315A, 50 Hz with enclosure, flexibility of neutral connection, line and loadreversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 . |
| 515 | Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity with 99.9% aluminium purity with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB |
| 516 | Supplying and erecting self locking arrangement with duplicate keys, made of brass duly erected, flush with surface of panel/cupboard. |
| 517 | Providing & erecting 3 Pole MCCB upto 100A, 415V, with short circuit rating 25 kA (Ics=100% of Icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB |
| 518 | Supplying and erecting terminal spreaders for use on MCCB incoming and outgoing terminals for 3 pole upto 100A MCCB complete. (set of 6). |
| 519 | Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for upto 250A MCCB complete. |
| 520 | Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 250A up to 630A MCCB |
| 521 | Supplying and erecting terminal spreaders suitable for 4 pole, upto 250A MCCB (Set of 8) |
| 522 | Supplying and erecting terminal spreaders suitable for 4 pole, above 250A up to 400A MCCB (Set of 8) |
| 523 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB |
| 524 | Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 525 | Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit |
| 526 | Supplying, fixing and commissioning 4 pole RCBO 63A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO |
| 527 | Providing & erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting andadjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB |
| 528 | Supplying and erecting terminal spreaders suitable for 4 pole, up to 100A MCCB (Set of 8) |
| 529 | Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for upto 250A MCCB complete. |
| 530 | Supplying and erecting terminal spreaders for use on MCCB incoming and outgoing terminals for 4 pole above 250A upto 400A MCCB complete. (Set of 8) |
| 531 | Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 250A upto 630A MCCB complete. |
| 532 | Supplying and erecting metal work in CRCA sheet with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. (OUTDOOR PANEL) |
| 533 | Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 534 | Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard |
| 535 | Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB |
| 536 | Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 537 | Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 538 | Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box / panel and duly connecting with necessary PVC wire leads and lugs. |
| 539 | Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.. |
| 540 | 5 Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc. |
| 541 | Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc. |
| 542 | Supplying, installing, testing and commissioning 11 kV 630A, indoor type ring main unit with 2 VCB & 2 LBS with internal arc compliance complete erected on provided CC foundation/MS channels/trench, etc., as per specification no SW-HTS / RMU |
| 543 | Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, Mineral oil immersed and naturally cooled outdoor type, copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50 ℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TRNSL. |
| 544 | Supplying, erecting, testing and commissioning of diesel generating set with alternator of 200 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 34.40 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB(A) at 1.0 m, provided with first filling of oil, diesel not less than 300 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG |
| 545 | Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 200 kVA up to 250 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. |
| 546 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). |
| 547 | Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. |
| 548 | Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB |
| 549 | Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 550 | Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 551 | Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 552 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT |
| 553 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 300 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT |
| 554 | Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT |
| 555 | Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT |
| 556 | Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI |
| 557 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 558 | Supply, Installation, Testing & Commissioning 4MP VF Bullet/Dome 1/2.7\\" 4Megapixel PS, CMOSImage Sensor, Max. 4MP(2688 × 1520)@30fps, H.265+ and H.264+triple-stream encoding,WDR(120dB), Day/Night(ICR), 3D-DNR, ROI, AWB, AGC, BLC, 2.7mm~13.5mm MotorizedLens, IR Range of 60 Mtrs, IP67, IK10, Micro SD Card, PoE, IVS: Tripwire, Intrusion, MotionDetection, Scene Change., UL, CE, FCC, RoHSImage Sensor 1/2.7\\" 4Megapixel progressive CMOS (0.9407 centimeters) Minimum Illumination 0.005 [email protected] (Color, 30IRE) 0.0005 [email protected] (B/W,30IRE) 0 Lux (IR on) Effective Pixels 2688 (H) ×1520 (V) Shutter Speed Auto/Manual, 1/3 s~1/100000s White Balance Auto/natural/street lamp/outdoor/manual/regional customLens 2.7mm~13.5mm Motorized Iris Type Fixed DORI Distance W# 64.0m (Detect) 25.6m (Observe) 12.8m (Recognize) 6.4m (Identify) T# 222.0m (Detect) 88.8m (Observe) 44.4m (Recognize) 22.2m (Identify) Video Compression H.265+/H.265/H.264+/H.264/H.264H; H.264B; MJPEG Angle of View Horizontal: 104°#27° Vertical: 55° #15° Diagonal: 124° #31° |
| 559 | Supplying ,erecting, commisioning & testing Screen (108Cm)/ 43 inch specification General of Screen size 108cm x(43inch) Screen type LED HD technology and resolution Full Hd TV 1920 x 1080 HDMI, 3 USB : 1 launch year 2018, connectivity features (static) Picture Engine Hyper real view angle 178Degree panel type A+ Digital noise video features PMI 300 clarity colour , contract, active noise reduction Dynamic colour Enhancer picture mode : 8 Modes(vivid , standar, Aps, Cinema , cricket game Expert 2 Picture :JPEG Digital Noise reduction Movies support in USB mode ,MPEGH 264 , recorder response Time 6.5ms, still image , wide colour enhancer (Plus), Film mode Cricket Audio features Number of speakers : 2 , Speaker Type : Down firing with Bass reflex . Sound technology: Dolby Digital plus Speaker Output RMS:20 W Warranty, Warranty Summary : 1 year, comprehensive and warranty Summary : 1year and 1 year additional on Panel. |
| 560 | Supplying erecting Testing & Commissioning Camera NVR 32 Channel System specification 32ch with 4K Real -time Live Preview max 320 Mbps incoming bandwidth with H 265 compression , Decoding support upto 4 x 4 k @ 30 , 8 ( 4 MP @ 200N VIF Version 2.4 conformance VCA Bearch and Smart for playback support 8 SAT AHDD upto sara 2 USB OJ 1 USB 3.0 |
| 561 | Supplying and Installation,Testing & Comissioning of surveliance internal HDD(hard Disk Drive) HDD Supply installation , testing and commissioning of Survilence internal HDD Recording capacity 4 TB. |
| 562 | Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 563 | Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification.No: WG-MA/CC. |
| 564 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG MA/CC. |
| 565 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification\ No. WG-MA/CC. |
| 566 | Supplying and installing cat-6 cable suitable for networking as per specification No: WG-COC/NC |
| 567 | Supplying and fixing 1 meter length, UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC |
| 568 | Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG NAS/UTPC. |
| 569 | Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS |
| 570 | Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK |
| 571 | Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367mm) as per specification No. WG-NAS/RAK |
| 572 | Supplying and fixing Power Distribution Unit for networking rack comprises of 6/16A (6 Nos. sockets), 25 A modular MCB, appropriate rating fuse andm indicator lamp, enclosed in black powder coated metal with necessary arrangement for fixing as per specification No. WG-NAS/RAK |
| 573 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP |
| 574 | Supplying and installing cat-6 STP cable suitable for networking complete as per specification |
| 575 | Supplying and erecting 10m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. |
| 576 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 577 | Point wiring for light/fan/bell in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch and required accessories as per specification No: WG-PW/SW |
| 578 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 579 | Supplying & erecting mains with 1x1.5 sq.mm H.F.F.R. copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 580 | Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 581 | Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 582 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 583 | Supplying & erecting 5W-7W, 230V integral type LED Lamp suitable for B-22 / E-27 base. |
| 584 | Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumensoutput of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 585 | Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. (1 Bulkhaed in each lift shaft). |
| 586 | Supplying and erecting Exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specifcationno. FG-FN/EXF |
| 587 | Supplying, erecting & marking SPMCB 6A to 32A (B-series for Lighting) in provided distribution board as per specification No. SW-SWR/MCB |
| 588 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 589 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB (in each lift room 1 for 3-phase RCCB/ ELCB & 1 for 1-phase RCCB/ ELCB & 2 Nos. SP MCB) |
| 590 | Providing, erecting & commissioning RCCB of electro magnetic type with 30/100/300 mA sensitivity and having capacity of 63A. 4 pole complete as per specification No. SW-RCCB/RCCB |
| 591 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 592 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU (form Generator to changeover switch) |
| 593 | Supplying and erecting Annealed bare copper wire of high purity of different sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws in an approved manner. |
| 594 | SITC of Electric Traction Passenger Lift with 1299498· Rated capacity :- 10 Passenger/680Kg· Floors :- G+1 floor (2 Stops/2 Landings)· Travel :- 3 to 4.2 mtrs· Location of Lift Machine:- MR/MRL· Rated speed :- 1.0mps VS· Car/Landing door clear opening of 800 mm wide x 2000 mm high· Clear Car size of 800 mm wide x 2500 mm deep x 2250mm high· Lift shaft available having clear size of 1900mm wide x .1900mm deep,13050mm Pit depth Overhead.· Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory). Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons withBraille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings.Lift controller based on microprocessor/ PLC with VVVF Drive havingclosed loop control system, with IBMS compatible having necessary port. Thecontroller shall have necessary protections such as overcurrent, overvoltage, overspeed, overheat for all devices including lift motor and travel directionprotection, protection for phase loss at input or output etc. various operationmodes such as maintenance, change direction by attendant, full load bypass, VIPcall operation, self levelling operation, call cancel facility, auto return to homelanding, fireman evacuation operation, earthquake operation, door open/closeoperation from COP etc. The system can record information for minimum 30latest faults, with real-time clock management and handheld keypad with LCDscreen for view and setting of parameters. The control panel duly wired withproper size & strength, copper wire for power & control circuit, with provisionfor addition of floor/control card & allied accessories control panel havingenclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IPbased vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimedon Lift machinery & controller with NVR kept in LMR/FCC with HDR databackup for min. 90 days with min.18” FHD TV monitor, to be kept in FCC/LMRas directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory), with Traction pulley, OSG,electromagnetic brakes, entire assembly mounted on adequate size girders dulyfixed on LMR floor/ shaft walls complete with main/diverter traction sheaves,suspension wire ropes/belts of adequate size & strength. Other mechanical parts such as 'T' section adequate size guide rails for car &counter weight with brackets fasteners, counter weight frame with necessaryblocks, buffers with necessary support arrangement, MS pit ladder etc. erectedwith necessary steel work.· Minor civil work such as alteration work if any necessary for erection oflanding door frames and it's accessories e.g. sill, header, hole pass etc completewith plaster finish, civil work for erection buffers, erection of lift machinery,adequate size core cuts if required & scaffolding for erecting guide rails, providingand fixing steel girders/RCC work having adequate strength for mounting andhoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erectionpermissions & \\"License to Work the Lift\\" from Electrical Inspector(Lifts) withsubmission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year from the dateof commissioning. Note:- A.2 For (Additional 2 Floor extra Pay Rs.2,74,062.00) Aditional Floor Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid (non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators,extension of guide rails, shaft wiring with trunking, traveling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete.(Additional 1 Floor extra Pay Rs.1,37,031.00) |
| 595 | Supplying, installing, testing and commissioning of 25 kWp ON-GRID Solar PVSystem / Plant consisting Solar PV Mono Crystalline Panel (580-620 Wp X 121 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate,canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB ,MCB etc. wiring up to solar Inverter in casing and capping, display board, signboard, two distinct earthing, lightning arrester, liaisoning charges, remotemonitoring system with maintaining card / chip for 5 years including net chargesfor RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract asper Specification no. ESD-RT-ONG. |
| 596 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 597 | Supplying and erecting AC three phase LT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3 x 240V, 50Hz, with backlit LCD display, optical port & RS 232 port (measures import kWh, kVAh, export kWh, kVAh, Net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. |
| 598 | Supplying and erecting static energy meter with 3 x 240V 50 Hz. AC supply 10 to 60 A, ISI mark, accuracy class 1.0 with backlit LCD display, (Measuring and display Trivector, V, I, kW, PF, Hz, Last month history of kWh and MD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power & with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supply company. |
| 599 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 50 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 600 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL(For 25 Kw Site) |
| 601 | Supplying and erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (NOTE-1) (For 10 Kw Solar System) |
| 602 | Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (NOTE-1) |
| 603 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 160 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 604 | Supplying and installation of Solar PV Module cleaning unit consisting of nozzles spray, necessary pipes, valves, post, electronic panel board concealed with weather proof cabinet, spreading water periodically for removal of dust, related motor pump, controller, timer and nozzles set suitable for covering 5 KW Solar PV Module. (Approx. 35 Sq. Mtr. PV Module area). |
| 605 | For item no. 4-8-8 for additional kW capacity, add Rs. 4000/- for every 5kW. |
| 606 | Supplying and installing G.I.pipe above ground of ‘C’ class ERW of size 100 mm diawith necessary fittings as per specification no. FF-PP |
| 607 | Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 75/80 mm dia with necessary fittings complete as per specification no. FF-PP |
| 608 | Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 65 mm dia with necessary fittings complete as per specification no. FF-PP |
| 609 | Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 50 mm dia with necessary fittings complete as per specification no. FF-PP |
| 610 | Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 25 mm dia with necessary fittings complete as per specification no. FF-PP |
| 611 | Providing coating of bitumen paint & 4mm thick wrapping for underground 100 mm ring main of fire fighting system |
| 612 | Carrying out core cutting of size 3\\" to 5\\" dia x 15\\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in propermanner and finishing the site as original. |
| 613 | Supplying and installing cast iron foot valve ball type/flap type of size150 mm dia with strainer for negative suction as per specification No.FF-VL/FV |
| 614 | Supplying and installing cast iron foot valve ball type/flap type of size 80 mm dia with strainer for negative suction as per specification No.FF-VL/FV |
| 615 | Supplying and erecting 75/80 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS |
| 616 | Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS |
| 617 | SSupplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 618 | Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 619 | Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 620 | Supplying and erecting 75/80 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 621 | Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 622 | Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV |
| 623 | Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV |
| 624 | Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP |
| 625 | Supplying and installing one piece moulded HDPE / fibre water tank for negative suction only, having capacity 1000 litres fitted with necessary accessories complete as per specification no. FF-FFA/PT |
| 626 | Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV |
| 627 | Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe,15m in length,, fitted with necessary accessories complete as per specification no. FF-FFA/RRL |
| 628 | Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specification no. FFFFA/NZ |
| 629 | Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC |
| 630 | Supplying and erecting fire brigade header ( Siamese connection ) of 150 mm dia, for supplying water in fire tank completeas per specification no. FF-FA/FMC |
| 631 | Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT |
| 632 | Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV |
| 633 | Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG |
| 634 | Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS |
| 635 | Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheetand angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8\\" x 6\\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) |
| 636 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 637 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 638 | Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps) |
| 639 | Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete. |
| 640 | S u p p l y i n g & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete |
| 641 | Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 110 to 90 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 11 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/JP |
| 642 | Supplying, installation, testing and commissioning of main fire pump (MFP /EP) suitable for water discharge of 2280 to 2850 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 55kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP |
| 643 | Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 1600 to 1800 LPM at 70 to 50 m head driven by 45 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable towork on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine,exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mmthick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for autostop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plasteredwith anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of syntheticenamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932of 2003) complete, as per specification no. FF-MFP/SSC/DP |
| 644 | Supplying, erecting, testing & commissioning of fire pump control panel (FCP)of cubical construction, floor mounted type, fabricated from minimum 2 mmthick CRCA sheet, compartmentalised with hinged lockable doors, with enclosureprotection class IP54, duly powder coated or painted with accessories dulypainted with two coats of synthetic enamel paint of fire red colour over a coat ofprimer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection withsuitable size solid copper busbar strip of adequate size for all power connectionshaving switchgears and accessories, mountings and internal wiring with adequatesize copper conductor cable, earth terminals, numbering etc. complete in allrespect, suitable for satisfactory operation of main fire pump and jockey(pressurisation) pumps (1working+1standby) with necessary accessories, wiring &cabling along with allied accessories with following incoming and outgoings,suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply asper specificationsthe capacity of electric motor driven pump are as followsa. Main fire pump(MFP) having capacity of 22kW 1no (1 working)b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby,alternate run per start in auto mode) comprises of the following features & switchgears:1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating.2. Electrolytic grade copper strips for busbar of suitable sizes for main incomerand branches to motor SFU's, starters & outgoing terminals with necessaryaccessories like stainless steel nut bolts with spring washers for connections,mounted on required no of epoxy or porcelain support insulators of suitableratings etc.3. Individual pump TPN SFU having rotary handle with HRC fuses of suitablerating. BESIC RATE - 182320.00 ADD FOR NOTE - A.S (55kw) 69004.00 D( DIESEL PUMP ) - 68381.00 |
| 645 | Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI |
| 646 | Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½\\") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FFSPR. |
| 647 | Supplying and erecting XLPEarmoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ceiling as per specification No.CB-LT/CU |
| 648 | Supplying, erecting testing and commissioning optical type smoke detector on suitable back box with necessary connections complete as per specification no. FF-FAS/SD |
| 649 | Supplying, erecting, testing and commissioning manual call point (Pill box) with break glass push button and flip abort switch or agent release switch in metal enclosure complete as per specification no. FF-FAAS/MCP |
| 650 | Supplying, erecting, testing and commissioning hooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete as per specification no. FF-FAAS/HTR |
| 651 | Supplying, installing, testing and commissioning of 2 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories, 16x2 Character LCD Display, provision for zone wise contact and beep sound alarm, suitable to operate on 120-220 V AC, 0 - 49 Deg C, 93 ± 2Percentage RH (non- condensing) at 32 ± 2 Deg C complete as per specification no. FF-FAAS/FACP |
| 652 | Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall |
| 653 | Supplying, erecting, testing and commissioning of 28HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitablegreen equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longerpiping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shapefor increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooledcondenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weatherproof cabinet complete. |
| 654 | Supplying, erecting, testing and commissioning of 20HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitablegreen equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56°C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longerpiping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shapefor increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooledcondenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. |
| 655 | Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 2.6TR (918 cfm) to 2.8TR ( 1100 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete. |
| 656 | Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size)of nominal cooling capacity 2.0TR (618 cfm) to 2.3TR (671 cfm) having EER as per BEE standards and specifications, suitable as per site requirementwith swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remotecontrol, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as perrequirement during installation. |
| 657 | Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.3TR (1165 cfm) to 4.0TR (1218 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. |
| 658 | Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type room/indoor unit (IDU) of nominal cooling capacity 1.0TR (358 cfm) to 1.25TR (417 cfm) having EER as per BEE standards and specificationswith multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for coastal area. Unit shall be of decorative slim dimension suitable indoor wall mounting. The indoor unit shall also have an electronic control console. The unit shall be suitable for wall mounting and provided with suitable mounting brackets with any additional refrigerant and oil charge as per requirement during installation complete. |
| 659 | Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.3TR (421 cfm) to 1.7TR (586 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete. |
| 660 | Supply, installation, testing and commissioning of VRF/VRV based Hi-walltype indoor unit (IDU) of nominal cooling capacity 1.8TR (594 cfm) to2.2TR (655 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporatorcoil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete. |
| 661 | Supplying and installation of high pressure grade required size copper connection Y or T- Joints / refnet for liquid and suction line complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV / VRF air conditioning system. |
| 662 | Supply, installation, testing and commissioning cordless remote contol having colour LCD panel, real time clock, temperature limitation (16 to 30 degree Cent.), functions like filter clean reminder timer suitable to communicate with wired controller complete. |
| 663 | Supplying, erecting, testing and commissioning centralised programmable remote contol panel (HMI) touch manager controls minimum 16 system of minimum 64 ODU's can be controlled and up to 992 IDU's can be individually mounted and controlled indoor units having minimum 200 mm size colour LCD touch panel, yearly schedule, power proportional distribution function, temperature limitation, history function complete erected on wall with an arrangement to integrate with provided fire alarm system. |
| 664 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 41.3 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. |
| 665 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 34.9 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. |
| 666 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. |
| 667 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. |
| 668 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. |
| 669 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. |
| 670 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. |
| 671 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. |
| 672 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. |
| 673 | Supplying, erecting & terminating XLPE armoured cable 2 core 2.5 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 674 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 675 | Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 676 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 677 | Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 678 | Supplying and erecting aluminium powder coated linear grill of suitable size for width length without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 15/30/45°. |
| 679 | Supply, fabrication, installation and testing of flexible canvas connections constructed between ductable unit/dampers/ducting of suitable size with fire resist flexible double canvas sleeve complete. |
| 680 | Supplying and erecting circular flexible/rigid PVC pipe duct of size 150mm dia, 4mm thickness with required couplers, reducers, T-joints, Y-joints elbowsand necessary supports etc. with sealing with provided control/air flow regulating valves/dampers, filters at position complete |
| 681 | Supplying and erecting circular flexible/rigid PVC pipe duct of size 100mm dia, 4mm thickness with required couplers, reducers, T-joints, Y-joints elbows and necessary supports etc. with sealing with provided control/air flow regulating valves / dampers, filters at position complete. |
| 682 | Supplying and erecting circular flexible/rigid PVC pipe duct of size 80mm dia, 4mm thickness with required couplers, reducers, T-joints, Y-joints elbows and necessary supports etc. with sealing with provided control/air flow regulating valves/dampers, filters at position complete. |
| 683 | Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline fresh air fan inlet unit having 1000 cfm capacity with maintaining the static pressure minimum 20mm suitable to operate on 1ph, 230 V, 50Hz, A.C. supply complete |
| 684 | Supply, installation, testing and commissioning air curtain of 6 feet width having air throw velocity of 21 m/sec, low noise level up to 38 to 46 BA suitable for door height upto 9 feet, working on 1 phase, 230V, 50Hz, A.C. supply |
| 685 | Carrying out core cutting of size 3\\" to 5\\" dia x 15\\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in propermanner and finishing the site as original. |
| 686 | Supplying and installing of collar damper of galvanised iron material of upto 120 microns for anti corrosive resistance for supply air grill of suitable size |
| 687 | Providing adhesive thermal insulation for supply return air duct with 19mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC- 2017. |
| 688 | Supply, installation, testing and commissioning of Air CoolingUnit,Air coolers draw, filter and deliver fresh air, which circulate stale air,With power-saving technology,Reduce temperature and passing the hot fresh air through the wettedpads,The filter pads shall contain Celldeck or suitable material capable of holding moisture in a nylon mesh bag/ mesh with spikes and so fixed to be spread uniformly over the panel ,Thepad shall completely cover the grill panel : following features: Power Supply: 3 phase(415V /50H), Body Type UV Stabilized Engineering, Motor : 1.1 KW, Noise: < 74db , Fan Type: Axial Water Tank: 70L ,Capacity: 11800 CFM.MAKE :- SYMPHONY/Metatech/ GSK / Kerulai |
| 689 | Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process complianceto IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2coats of enamel paint. |
| 690 | Supplying and erecting GI sheet 0.6 mm (24 SWG) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 691 | Supply, installation, testing and balancing of powder coated extruded Aluminium Supply & Exhaust air Square Grill with zero degree deflection |
| 692 | Supply Installation Testing & commissioning of 13 mm N Clad Chemically Cross- linked Closed Cell polyolefin foam with factory applied reinforced UV Resistant aluminum Foil. Withweather resistance or high durability,Protech insulation material from mechanical damage , UV and weather conditions. N clad Has a low thermal conductivity of 0.035 W/mk (ASTMC518) |
| 693 | Supply, fabrication, installation an testing of flexiblecanvass connections constructed between ductable unit / dampers / ducting of required size with fire resist flexible double canvas sleeve complete |
| 694 | Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. APWCR/WC |
| 695 | Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system. |
| 696 | Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 697 | Supplying & erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply up to 7.5 H.P. |
| 698 | Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 5.625 KW/7.5 HP with 415 V 50 c/s. A.C. supply, having delivery head from 57 to 22 m and discharge from 120 to 900 litres. . per minute & pipe of Suction 75 mm/Delivery 65 mm diameter erected with necessary H type clamps as per specification No. WP-OSP |
| 699 | Supplying & erecting Water level controller 230/415 V, A.C. , Two way underground tank operation only. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail