| 1 | Supply part HT Line |
| 2 | Supply of 9.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980 (Part-'A') as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-47 |
| 3 | Supply of RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if any. |
| 4 | Supply of ACSR conductor of size 6/1/3.35 mm (50mm2) conforming to IS-398 (Part-II)/1996 with upto date amendments |
| 5 | Supply of 11 KV Disc insulator B&S type conformimg to IS-731/1971 all latest version thereof for suspension & tension string ball and socket type having pin ball. The minumum and maximum creepage distance with diameter of insulator- 225 mm & having electromechanical strength 90KN. The insulator shall have W type phosphors bronze security clips for ball socket porcelain conforming IS: 2486-1971 (90KN) complete in all respect. Moderately polluted atmospheres Creepage distance 320mm |
| 6 | Supply of 11 kV Pin Insulator Brown Glazed Porcelain insulator alongwith GI Pin confirming to IS-731/1971 or latest version thereof with minimum and maximum creepage distance distance & duly fitted with lead/zinc thimble suitable for use with GI forged pin having small steel head as per IS:2486 (Part-I & II) of 1993 & latest amendment if any. Moderately polluted atmospheres Creepage distance- 320mm |
| 7 | Supply of MS Angle Iron 50x50x6 mmLength 1800 mm x 2No.): Fabrication and supply of members made of only TATA/SAIL/RASHTRIYA ISPAT M.S. Angle Iron 50x50x6 mm, suitable for fixing on Steel double pole structure of 11KV structures with holes at suitable places wherever required to adjust 5/8” dia nuts and bolts. The weight of MS Angle Iron should be 4.5 Kg per meter with a variation of +/-5%. The member should be duly painted with two coat red oxide paint of superior quality: |
| 8 | Prov. X-Bracing Set - MS Angle Iron: 50x50x6, Length 2125 mm x 2No.)Supply of MS Angle Iron 50x50x6 mm :Fabrication and supply of members made of only TATA/SAIL/RASHTRIYA ISPAT M.S. Angle Iron 50x50x6 mm, suitable for fixing on Steel double pole structure of 11KV structures with holes at suitable places wherever required to adjust 5/8” dia nuts and bolts. The weight of MS Angle Iron should be 4.5 Kg per meter with a variation of +/-5%. The member should be duly painted with two coat red oxide paint of superior quality: |
| 9 | Supply of CI X-Arm (Horizontal) - MS Channel Iron100x50x6, Length (2340 mm x1 No.) Fabrication and supply of members made of only TATA/SAIL/RASHTRIYA ISPAT M.S. Angle Iron 100x50x6 mm, suitable for fixing on Steel single pole structure of 11KV structures with holes at suitable places wherever required to adjust 5/8” dia nuts and bolts. The weight of MS Angle Iron should be 4.5 Kg per meter with a variation of +/-5%. The member should be duly painted with two coat red oxide paint of superior quality: |
| 10 | Supply of CI X-Arm (Horizontal) - MS Channel Iron100x50x6, Length (2800 mm x1 No.) Fabrication and supply of members made of only TATA/SAIL/RASHTRIYA ISPAT M.S. Angle Iron 100x50x6 mm, suitable for fixing on Steel single pole structure of 11KV structures with holes at suitable places wherever required to adjust 5/8” dia nuts and bolts. The weight of MS Angle Iron should be 4.5 Kg per meter with a variation of +/-5%. The member should be duly painted with two coat red oxide paint of superior quality: |
| 11 | Supply of CI X-Arm (Horizontal) - MS Channel Iron: 75X40x6, Length (2800 mm x2 No.) for supporting GO switch and DO Fuse. Fabrication and supply of Cross arms suitable for 11 KV made of only TATA/SAIL/RASHTRIYA ISPAT M.S. Channel Iron 75x40x6 mm Cross Arm, suitable for fixing on both Steel and PCC Poles whatever is required single/double pole structure of 11KV line with holes at suitable places wherever required to adjust 5/8” dia nuts and bolts, pin insulators, ball cleaves, eye socket and washers. The weight of MS channel should be strictly 9.56 Kg per meter with a variation of +/-5%. The Cross Arm should be duly painted with two coat red oxide paint of superior quality: |
| 12 | Supply of GO switch handle supporting CI X-Arm (Horizontal) - MS Channel Iron: 75X40x6, Length (460mm) Fabrication and supply of Cross arms suitable for 11 KV made of only TATA/SAIL/RASHTRIYA ISPAT M.S. Channel Iron 75x40x6 mm Cross Arm, suitable for fixing on both Steel and PCC Poles whatever is required single/double pole structure of 11KV line with holes at suitable places wherever required to adjust 5/8” dia nuts and bolts, pin insulators, ball cleaves, eye socket and washers. The weight of MS channel should be strictly 9.56 Kg per meter with a variation of +/-5%. The Cross Arm should be duly painted with two coat red oxide paint of superior quality: |
| 13 | Prov. X-Bracing Set - MS Angle Iron: 50x50x6, Length 450 mm x 1No.)Supply of MS Angle Iron 50x50x6 mm :Fabrication and supply of members made of only TATA/SAIL/RASHTRIYA ISPAT M.S. Angle Iron 50x50x6 mm, suitable for fixing on Steel double pole structure of 11KV structures with holes at suitable places wherever required to adjust 5/8” dia nuts and bolts. The weight of MS Angle Iron should be 4.5 Kg per meter with a variation of +/-5%. The member should be duly painted with two coat red oxide paint of superior quality: |
| 14 | Supply of Stay Set Suitable for 11KV made of M.S. Round 1800mm in length, 18mm dia having threads up to 300mm on one end with one nut and one check nut to avoid slippage and eye of 40mm dia on other side and welded confirming to REC specification. Elbow made of MS channel iron 75x40x6mm, 250mm long and M.S. Round 18mm dia, vertical height 450mm, both ends bend after putting in two holes in channel iron taking the ends out 25mm minimum in length and welded with channel iron. One anchor of Angle Iron 65x65x6mm, 750mm in length with one hole of 20mm dia in the centre. The complete stay set shall be painted with superior quality black Japan paint. |
| 15 | Supply of Galvanized Stay Strand conforming to ISS-2141/1992 Edition 2002-05 (with upto date amendments) with heavy coating Zinc hot Dip Galvanized as per ISS-4826/1979 (2001-06) (latest)of following grade and size:- Grade -4 Size 7/3.15mm (7/10SWG) |
| 16 | Supply of Earthing set suitable for HT line/Earthing of metering unit made of GI pipe 40 mm dia (internal dia) wall thickness 3.25 mm medium quality pipe of standard make conforming to IS: specifications 2500 mm long with GI Socket closed at top pipe shall have holes of 12 mm dia every 150 mm apart throughout the length and staggered diameterically. Full clamps of MS Flat 40x3 mm fitted at top end of the pipe along with bolts and nuts size 50x12 mm and washers for fixing the clamp on the pipe. The bottom end of the pipe shall be tapered cut at 45 degree. |
| 17 | Supply of Galvanised Mild Steel wire conforming to ISS-280/1978/2006 (with up to date amendments ) for general engineering purpose, having fine finish, hot dip galvanised, with heavy coating of Zinc as per ISS-4826/1979 (2001-06)(latest) in soft condition and of size 4.06 mm (8 SWG) |
| 18 | Supply of Eye hook |
| 19 | Supply of M.S. Hexagon Bolts and Nuts with washers conforming to ISI-1363-1992 off size |
| 20 | Supply of Danger Plate Size: 250x200x1.6 mm made of mild steel plates 1.6 (minimum) thick vitreous enameled white letter figure, conventional skill and X-Boxes and signal red colour on front side for use in HPSEBL. The rear side of the plate shall be black enameled and conforming to IS specifiction no. IS-1351/1982 suitable for 11KV |
| 21 | Supply of Galvanised steel barbed wire of 9.8 kg /100metre |
| 22 | Supply of Half Clamp (MS Flat 50x6mm) |
| 23 | Supply of Full Clamp (MS Flat 50x6mm) |
| 24 | Supply of Aluminium Paint for all poles and steel fitting |
| 25 | GO switch unit (11kv, 400A, 25KA) Tripple pole O/D type. |
| 26 | D.O Fuse Unit |
| 27 | Erection of HT LINE |
| 28 | Erection of steel tubular pole 09.00 Mtr. Long (Double pole str) digging of pit, Drilling of holes in X-arm, Erection of pole, Fixing of insulator X-arm, Fixing of barbed wire danger plate , Concreting of RCC Muff with c:c 1:3:6 (1 cement :3 sand :6 aggregate 20 mm nomial size with curing complete etc.) , Filling of pit+ramming, painting of pole and all steel items (Punching of the poles is stricitly not allowed) |
| 29 | Laying, stringing , sagging & binding with Insulator of ACSR rabbit conductor of size 6/1/3.35 mm (50mm2) including jumpering etc. complete. |
| 30 | Erection of Stay Set HT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting) |
| 31 | Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit) |
| 32 | Laying, stringing , sagging & binding of GI Wire |
| 33 | Erection of GO switch on tapping/Line structure |
| 34 | Transportation by truck to site of work of HT line and its associate material including Loading Unloading. |
| 35 | MANUAL CARRIAGE OF MATERIAL FOR HT LINE CONSIDERING AVERAGE DISTANCE FROM ROAD HEAD TO SITE OF WORK AVERAGE LEAD= 0.200 KM |
| 36 | HT Steel Poles 09 mtr. Long and RCC Muff |
| 37 | Manual carriage of associate material (accept ST poles) like wise cross arm, bracing set, insulators, stay set, stay wire, Conductor & GI wire. |
| 38 | Supply Part DTR 250kva |
| 39 | Supply, Testing etc. including Design, engineering, manufacture, assembly, inspection, testing and delivery of ISI marked, non-sealed, oil immersed, ONAN type, 50 Hz. double wound, 3-phase- 11/0.433KV, 250KVA, outdoor type distribution transformers, for use in power distribution system. (Approved vendor of HPSEBL) |
| 40 | Supply of 9.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980 (Part-'A') as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-47 |
| 41 | Supply of RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if any. |
| 42 | X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 4 Nos for incomer line |
| 43 | MS angle Iron (50X50x6 mm), Length : 2800 mm x 1 Nos for LA |
| 44 | X-Arm: [Channel Iron (75x40x6 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch |
| 45 | Transformer LT Distribution Box and GO Switch fixing Assembly |
| 46 | MS angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos |
| 47 | MS angle Iron (50X50x6 mm), Length : (450 mm) x 2 Nos |
| 48 | GO switch handle Supporting : (Channel iron (75x40x6 mm) , Length: 460mm. |
| 49 | GO switch unit (11kv, 400A, 25KA) Tripple pole O/D type. |
| 50 | D.O Fuse Unit |
| 51 | Surge Arrester, 9 kV Station Class (Porcelain Type) |
| 52 | Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) |
| 53 | Stay set complete |
| 54 | Stay Wire (7/3.15 mm) (7kg Per Stay Set) |
| 55 | Pipe Earthing Set |
| 56 | Supply of 6SWG GI wire For Earthing |
| 57 | Supply of LT Distribution Panel Box suitable for 250KVA S/Stn of size 1100x800x275mm +/- 5% made of steel sheet of 1.63 mm thickness having double door locking arrangement duly powder coated painted complete withLT Distribution Panel Box with MCCB 400 amp 3P 50kA-1 No. Make L&T , Schneider and ABB only, MCCB 250 Amp 36kA 3P of L&T Schneider and ABB make only 3No. MCCB Rating 250Amp, 3 Poles having following specifications (1) Minimum frame size 250 Amp (2) Type variable trip free, (3) Breaking capacity- Isu & LCS at 415, 50 Hz (KA: not less than 50 KA) (4) , Thermal release range: 320-440Amp (5) Mecanical life (operation) 20000 No. (6) Electrical life (operation) 4000 No. (7) Rated insulation voltage (V) 690V (8) Tripping thermal releasing setting : Thermal-O/L variable setting (9) Tripping magnetic releasing setting : Magnetic- S/C fixed setting (12) in (10) (Operation) volatge 415V, AC (11) Caliberation temperature: 40 degree C (12) High voltage withstand voltage : 3KV for 1 minute (13) Confirming to IS : 1993/60947-2, 1989 (14) Make L&T/ Havells/ABB/ HPL/ Schiender and approved vendor of HPSEBL (15) ICS : 100% ICU Reangular type aluminum alloy bus bar of 250 Amp. having length 800 mm of Phase 800 mm long for netural outgoing feeder 3 nos. outgoing feeders shall be made in the Pannel U type Single pole MCCBs of 400 Amp. shall be provided in all 3- phases. The panel shall be fully wired with insulated copper wire have adequate clearance . As per standard specification |
| 58 | Half Clamp (M.S. Flat 50x5 mm) |
| 59 | Full Clamp (M.S. Flat 50x5 mm) |
| 60 | Guide Clamp |
| 61 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)] |
| 62 | Aluminium Thimble 300 sq mm |
| 63 | Copper Thimble 95 sq mm |
| 64 | Barbed wire |
| 65 | Danger Plate |
| 66 | Aluminium Paint. |
| 67 | LT Cable (3.5 core ) 300 mm2 |
| 68 | ACSR Conductor 6/1/3.35 for jumpering |
| 69 | switch capacitor 81-KVR for 250 KVA transformer |
| 70 | Erection of DTR |
| 71 | Erection of 250 KVA , 11/0.433KV DTR, complete viz digging of pit for poles & earthing (2 No. for pole & 3 no. for earthing), Drilling of holes in X arms & poles Prepration of plateform structure member CI, AI i.e. X-arm & Knee bracing set, Erection of Double Pole Structure, Concreting of RCC Muff with c:c 1:3:6 (1 cement :3 sand :6 aggregate 20 mm nomial size with curing complete etc.), Erection of plateform, Erection of x-arms, Erection of G.O. Switch, Erection of Drop-Out Fuse Unit, Erection of Lightning arrestor, Erection of LT Box, Providing Earthing connection including G.I.Wire to G.O Switch, Transformer, Lightning arrestor, etc , Erection of 4 Nos. Stay set , Erection of Jumper, Pipe Earthing 3 No. sets , Laying of LT Cable, Barbed wire & painting complete in all respect. |
| 72 | Transportation charges inclusive of hydra crane charges and mannual carriage of DTR and its associate material. |
| 73 | Estimate cost for providing wooven mesh fencing along with Gate & locking arrangement (2Nos) |
| 74 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation |
| 75 | Providing and laying in position cement concrete of specified grade excluding the cost of centering |
| 76 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of shuttering & steel work |
| 77 | Steel work welded in built up sections trusses and framed work including cutting |
| 78 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50×50 Chain Link Fencing Wire |
| 79 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. |
| 80 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc comlete |
| 81 | Supply Part CT-PT Metering Equipment structure |
| 82 | Supply of CT-PT combined unit (PT: 11KV/110V ):CT:10-400/5A (“The CT-PT metering unit should be got tested/approved from M&T.”) |
| 83 | Supply of 3Ø 3/4 wire CT-PT Operated Static Trivctor Meter (DLMS Compliant ) |
| 84 | Supply of PVC multistained 4 mm sq copper wire |
| 85 | Supply of ɸ-1 inch GI pipe for conceiling |
| 86 | Supply of Bend Joints/Elbow |
| 87 | X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos for incomer line |
| 88 | MS angle Iron (50X50x6 mm), Length : 2800 mm x 1 Nos for LA |
| 89 | X-Arm: [Channel Iron (100x50x6 mm), Length : 460 mm X 2 Nos for supporting Main Channel of CT-PT Unit |
| 90 | X-Arm: [Channel Iron (75x40x6 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch |
| 91 | CT-PT bed, belting & Knee Bracing |
| 92 | MS angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos |
| 93 | MS angle Iron (35X35x5 mm), Length : (460 mm) x 2 Nos |
| 94 | MS angle Iron (35X35x5 mm), Length : (950 mm) x 2 Nos for bed knee bracing |
| 95 | CT-PT GO Switch fixing Assembly |
| 96 | GO switch unit (11kv, 400A, 25KA) Tripple pole O/D type. |
| 97 | D.O Fuse Unit |
| 98 | Surge Arrester, 9 kV Station Class (Porcelain Type) |
| 99 | Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) |
| 100 | Stay set complete |
| 101 | Stay Wire (7/3.15 mm) (7kg Per Stay Set) |
| 102 | Pipe Earthing Set |
| 103 | Supply of 6SWG GI wire For Earthing |
| 104 | Half Clamp (M.S. Flat 50x5 mm) |
| 105 | Full Clamp (M.S. Flat 50x5 mm) |
| 106 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)] |
| 107 | Aluminium Thimble 300 sq mm |
| 108 | Copper Thimble 95 sq mm |
| 109 | Barbed wire |
| 110 | Danger Plate |
| 111 | Aluminium Paint. |
| 112 | Erection Part (CT-PT Metering Equipment structure):- |
| 113 | Erection of CT-PT Metering Equipment structure, complete viz digging of pit for earthing (3 no. for earthing), Drilling of holes in X arms & poles Prepration of plateform structure member CI, AI i.e. X-arm & Knee bracing set, Erection of plateform, Erection of x-arms, Erection of G.O. Switch, Erection of Drop-Out Fuse Unit, Erection of Lightning arrestor, Providing Earthing connection including G.I.Wire to G.O Switch, Lightning arrestor, etc , Erection of 4 Nos. Stay set , Erection of Jumper, Pipe Earthing 3 No. sets , Barbed wire & painting complete in all respect |
| 114 | Supply Part of 1-Phase LT line |
| 115 | Supply of 9.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980 (Part-'A') as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-47 |
| 116 | Supply of RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if any. |
| 117 | Supply of LT 1.1KV XLPE Cable Un Armoured 3.5x240 + 240mm sq 2 cables |
| 118 | Supply of shackle insulator. |
| 119 | Supply of D-Iron (U-Clamps) |
| 120 | Supply of LT stay set |
| 121 | Supply of Stay Wire (7/4 mm) (9.0 Kg per stay set) |
| 122 | Supply of Egg. Insulator |
| 123 | Supply of Full Clamps (4 No. for A.I. + 1 No. for Stay Set) |
| 124 | Supply of Earth Knob |
| 125 | Supply of Nuts & Bolts @25 KG Per Km. |
| 126 | Supply of Aluminium paint. |
| 127 | Supply of X-Arm (Horizontal) 600x100x50x6. |
| 128 | Supply of Knee Bracing Set- MS Angle Iron: (65x65x6, Length 1100 mm x 1 No.) |
| 129 | Supply of Anchoring Assembly for LT |
| 130 | Supply of Suspension Assembly for LT |
| 131 | Supply of Façade Hook for LT |
| 132 | Supply of Supply of Earthig Set complete (Preferbly coil earthing) |
| 133 | Supply of GI wire for Earthing |
| 134 | Erection Part:- LT |
| 135 | Erection of steel tubular pole 9.00 mtr long (Single pole) digging of pit, Erection of pole, Drilling of holes in X-arm, , Fixing of insulator X-arm knee-bracing set top clamp, Fixing of barbed wire danger plate, Concreting of RCC Muff with c:c 1:3:6 (1 cement :3 sand :6 aggregate 20 mm nomial size with curing complete etc.) , Filling of pit+ramming, painting of pole and all steel items (Punching of the poles is stricitly not allowed) |
| 136 | Laying, stringing , sagging & binding with Insulator & Installation of Suspension Assembly and Tension Assembly of LT AB cable 1.1 Kv XLPE Un armoured 3.5 x 240+240 mmsq. 2 cables. |
| 137 | Erection of Stay Set LT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting) |
| 138 | Erection of Earthing Set (Digging of pit, fixing of GI Wire, filling of pit) |
| 139 | Transportation by truck of LT Line its associate material including Loading Unloading. Please Enable Macros to View BoQ information |