| 1 | Carriage of Materials by Mechanical Transport including loading,unloading and stacking upto 1 KM- Lime, moorum, building rubbish. |
| 2 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 3 | i) 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 5 | i) Foundations, footings, bases of columns, etc. for mass concrete. |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (Steel reinforcement shall be supplied free of cost from NFL main stores). |
| 7 | i) Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 8 | Brick work withbricks of class designation 75 in foundation and plinth in : cement mortar 1:6 (1 cement: 6 fine sand ). |
| 9 | 12 mm cement plaster of mix: 1:6 (1 cement:6 Fine sand). |
| 10 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. - Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). |
| 11 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 12 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. - In cement mortar. |
| 13 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. - Cement mortar 1:4 (1 cement :4 coarse sand) |
| 14 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. - Granite of any colour and shade - Area of slab over 0.50 sqm. |
| 15 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling to be paid for separately) : |
| 16 | i) For fixed portion - Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 17 | ii) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) - Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 18 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness. |
| 19 | Providing Misc. items, fittings, Sanitary, Water Supply Sinks etc. or any other items as per instructions of the Engineer-in-Charge, which are not covered under other items of SOQ. For the purpose of payment %age above the Market rates of material supported by cash receipt / vouchers may be quoted. |
| 20 | Assisting in executing various job un-susceptible to measurement and other work which are not including in any items stated above/ scope of works as per instructions of the Engineer-in-Charge. : |
| 21 | i) For this purpose, contractor has to deploy Skilled Labour along-with all requisite tools & tackles for one day (For 8:00 hour), which will be treated as one unit of each operation. |
| 22 | ii) For this purpose, contractor has to deploy Un-skilled Labour along-with all requisite tools & tackles for one day (For 8:00 hour), which will be treated as one unit of each operation. Please Enable Macros to View BoQ information |