| 1 | Repair to Air Conditioning (Split/Window Type)Dismantling and taking out the existing old unserviceable reciprocating compressor hermetically sealed unit of any make from window type AC and S&F New reciprocating compressor suitable for window AC of capacity 1.5 Ton copper wound etc complete all as specified and directed. |
| 2 | All as per Srl item No.2.00 above but reciprocating compressor suitable for window AC of capacity 2.0 Ton complete all as specified and directed. |
| 3 | Dismantling and taking out the existing old unserviceable rotary compressor hermetically sealed unit of any make from split type AC and S&F New compressor suitable for Split AC of capacity 1.5 Ton copper wound complete all as specified and directed. |
| 4 | All as per Srl item No.3 above but rotary compressor suitable for Split AC of capacity 2.0 Ton complete all as specified and directed by Engineer in Charge. (Note for Srl No 2 to 41. All Engineering works shall be carried out at site AGE E/M store yard only in presence of Engr- in- Charge. 2. No equipment shall be transport/carry out to local market for repairs). |
| 5 | M&L for testing for leakage in system Window type Air conditioner of 1.5 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system complete all as specified and directed. |
| 6 | All as per item No 5.00 above but Air conditioner of 2 ton capacity complete all as specified and directed by Engineer in Charge. |
| 7 | M&L for testing of leakage in system Split type Air conditioner of 1.5 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system complete all as specified and directed. |
| 8 | All as per item No 7.00 above but Split type Air conditioner of 2.0 ton capacity complete all as specified and directed. |
| 9 | M&L for servicing of Air conditioning of Window/Split of any capacity including air Filter Cleaning, Condenser and Evaporator coil Cleaning, insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water complete all as specified and directedNote:-Item Serial No. 5.00 to 9.00(i) Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department.complete all as specified and directed (ii). Spare parts alongwith Refrigerant gas shall be measured and paid separately there rate above Rs. 100/- |
| 10 | S&F in repair starting capacitor of capacity 80/100 MFD complete all as specified and directed. |
| 11 | S&F in repair running capacitor of 36+6 MFD complete all as specified and directed. |
| 12 | S&F in repair running capacitor of 45+4/50+6/55 MFD complete all as specified and directed. |
| 13 | S&F in replacement of indoor unit incl outer body,fan motor, filter, copper cooling coil, blower, display, thermostate, sensor & PCB suitable for 1.5/2 TR split AC unit Non inverter type incltesting complete all as specified and directed. . |
| 14 | S&F in replacement of indoor unit incl outer body,fan motor, filter, copper cooling coil, blower, display, thermostate, sensor & PCB suitable for 1.5/2 TR split AC unit inverter type incltesting complete all as specified and directed. |
| 15 | S&F in repair Outdoor copper condesor unit suitable for upto 2.0 Ton Capacity Split AC complete all as specified and directed. |
| 16 | S&F in repair swing motor suitable for 1.5/2.0 Ton Capacity Window /split Air Conditioner complete all as specified and directed by Engineer in Charge. |
| 17 | S&F in repair outdoor PCB for inverter type upto 2.0 Ton Capacity Split AC complete all as specified and directed.. |
| 18 | S&F in repair Indoor PCB for inverter type upto 2.0 Ton Capacity Split AC complete all as specified and directed. |
| 19 | S&F in repair outdoor Fan Motor for inverter type upto 2.0 Ton Capacity Split AC complete all as specified and directed. |
| 20 | S&F in repair Indoor blower motor for inverter type upto 2.0 Ton Capacity Split AC complete all as specified and directed. |
| 21 | S&F in repair outdoor Sensor for inverter type upto 2.0 Ton Capacity Split AC complete all as specified and directed. |
| 22 | S&F in repair Indoor sensor for inverter type upto 2.0 Ton Capacity Split AC complete all as specified and directed. |
| 23 | S&F in repair Display Assembly for upto 2.0 Ton Capacity Split AC complete all as specified and directed. |
| 24 | S&F in repair running capacitor of 6 MFD complete all as specified and directed. |
| 25 | S&F in repair running capacitor of 2.5 MFD complete all as specified and directed. |
| 26 | S&F in repair running capacitor of 4 MFD complete all as specified and directed. |
| 27 | S&F in repair PVC Front gril suitable for Window type AC of any Make suitable for 1.5/2.0Ton window AC complete all as specified and directed. |
| 28 | S&F in repair electric blower motor double shaft suitable for upto 2.0 Ton Capacity Window type AC complete all as specified and directed. |
| 29 | S&F in repair electric blower motor for Indoor unit upto 2.0 Ton Capacity Split type AC complete all as specified and directed. |
| 30 | S&F in repair electric blower motor for Outdoor unit upto 2.0 Ton Capacity Split type AC complete all as specified and directed. |
| 31 | S&F in repair blower motor fan blade indoor suitable for 1.5/2.0 Split type AC complete all as specified and directed. |
| 32 | S&F in repair Outdoor fan blade suitable for 1.5/2 Ton capacity split type AC complete all as specified and directed. |
| 33 | S&F in repair fan blade suitable for 1.5/2 Ton capacity Window type AC complete all as specified and directed. |
| 34 | S&F in repair Remote for upto 2.0 Ton Capacity Split/Window type AC complete all as specified and directed by Engineer in Charge. . |
| 35 | S&F in repair thermostat switch with knob suitable for AC of any capacity complete all as specified and directed. |
| 36 | S&F in repair air Filter Suitable for 1.5/2.0 Ton Capacity Window/Split type Air conditioner complete all as specified and directed. |
| 37 | S&F in repair capillary tube length as per existing size suitable for 1.5/2.0 Ton Capacity Air conditioner complete all as specified and directed. |
| 38 | S&F in repair PCB Circuit with remote control suitable for any make and capacity of 1.5/2.0 Ton Window type AC and 1.5/2.0 split type capacity Air Conditioner complete all as specified and directed. |
| 39 | S&F in repair for PVC flexible drain out pipe for split AC suitable size fixed properly on wall /floor etc connetced propery complete all as specified and directed. |
| 40 | S&F for replacement of damaged Insulation of size 1/4&3/8, 1/2&5/8 for Split AC complete as per existing site complete all as specified and directed. |
| 41 | S&F for replacement of Rubber bush suitable for 1.5/2.0 ton capacity Suitable for Air conditioner as per sample complete all as specified and directed. |
| 42 | S&F for replacement of Copper Tube of size 1/4 inch and 3/8 inch suitable for any type and any capacity Air conditioner complete all as specified and directed. |
| 43 | S&F for replacement of Copper Tube of size 1/2 inch and 5/8 inch suitable for any type and any capacity Air conditioner complete all as specified and directed. |
| 44 | S&F for replacement of Flare nut of size 1/4inch, 3/8inch, 1/2inch, and 5/8inch suitable for any type and any capacity Air conditioner complete all as specified and directed. |
| 45 | S&F for replacement of Suction line charging Valve of size 1/2inch, 5/8inch suitable for upto 2 ton capacity split Air conditioner complete all as specified and directed.. |
| 46 | S&F for replacement of Discharge line valve of size 1/4inch, 3/8inch suitable for upto 2 ton capacity split Air conditioner complete all as specified and directed |
| 47 | Taking out and shifting to new location and refixing both indoor and outdoor unit of split type Air conditioning electrically driven 230V/250V ,AC 50 Hz capacity 1.5/2.0 Ton in wall with rowl plugs including making holes for inlet /outlet in the wall with 50mmX50mmX6mm size of agle iron for foundation of condensing unit as per suitable size and making good existing surface including insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water all as required and directed including necessary connection through voltage stabilizer etc complete all as specified and directed |
| 48 | M&L for rewinding for fan motor of air conditioner of any make and model upto 2 TR with super enameled copper wire with copper purity 99% (Minimum weight of winding wire 10 Kg per AC) of existing size and weight including replacement of bushing etc complete all as specified and directed |
| 49 | S&F in repair of PVC insulated sheathed flexible round, 4 core cable with copper conductor of size2.5 Sqmm for AC etc complete all as specified and directed |
| 50 | S&F in repair of sheet metal enclosure, single pole & neutral with two pin & earth plug and socket with one MCB single pole 20 amp, 240 volts etc complete all as specified and directed. |
| 51 | S&F in repair of contactor relay for split type AC etc complete all as specified and directed |
| 52 | S&F in repair of 2 pin metal socket & plug top for AC point single phase 240 volts etc complete all as specified and directed |
| 53 | S&F in repair of MCB single pole 240 volts, 10 to 32 amps, 10 kA, 'C' series, ISI marked etc complete all as specified and directedMake - Benlo/ havells or equivalent as approved by GE. |
| 54 | Dismantling of split AC of any capacity including refrigerant pipes, service connection, metal clad box and voltage stabilizer complete as required at site and depositing the same to MES yard. SOP is to be followed by proper pumping down of refrigerant gas before dismantling etc complete all as specified and directed |
| 55 | S&F in repair mounting frame/stand suitable for outdoor unit of split AC of any size etc complete all as specified and directed |
| 56 | M&L for Charging of gas R-22/R-410A/R-32/R-134(a)/ R-290 as existing Split / Window type Air Conditioner system any type and any capacity complete all as specified and directed by Engineer -in-Charge. . |
| 57 | M&L for Charging of gas R-22/R-410A/R-32/R-134(a)/ R-290 as existing Water Cooler, Refrigerator, Deep Freezer, Cold Room, VRF/VRV system any type and any capacity complete all as specified and directed. |
| 58 | S&F in repairs factory made board distribution (DB) in sheet steel enclosure without bus bar, SPN, 2 way, 240 Volts suitable for housing MCBs complete all as specified and as directed. |
| 59 | Taking down carefully unserviceable indoor electronic type PCB at existing location repair and refixing split type AC of capacity 1.5 to 2.0 ton complete all as specified and as directed. |
| 60 | Repair to Water CoolersDismantling and taking out the existing old unsv compressor sealed unit from Water cooler and S&F new compressor copper wound unit for operation on single phase, 230 V, 50 Hz, AC supply & confirm to IS-1067 Part-I, suitable for Water cooler of cooling capacity 40/80 ltrs/hrs and complete.Note :- 1. All Engineering works shall be carried out at site/E/M store yard only in presence of JE/Engr- in- Charge.2. No equipment shall be transport/carry out to local market for repairs |
| 61 | All as per item No. 60.00 above but compressor suitable for Water Cooler of cooling capacity 60/120 ltrs/hrs complete all as specified and directed. |
| 62 | M&L Checking the unserviceable water cooler of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete all as specified and directed |
| 63 | S&F in repair condensor motor 1/35 HP 230V,SP, 50 Hz suitable for 40/80 capacity water cooler as per existng sample etc complete all as specified and directed |
| 64 | All as per item No. 64 above but 1/10 HP suitable for 150/150,60/120 capacity or equivalent water cooler as per existng sample complete all as specified and directed. |
| 65 | S&F in repair condenser Blower fan blade suitable for 150/150,60/120 and 40/80 capacity water cooler or suitable for 1/10HP & 1/35 HP fan motor only including nuts/bolts any make and any capacity asper site requirement complete all as specified and directed. |
| 66 | S&F in repair running capacitor 8 mfd for condenser motor suitable for any capacity, size complete all as specified and directed. |
| 67 | S&F starting Capacitor suitable for compressor of water cooler of capacity 150/150,60/120 and 40/80 litre capacity complete all as specified and directed. |
| 68 | S&F in repair running capacitor 15mfd suitable for compressor of water cooler of capacity 150/150,60/120 and 40/80 litre capacity complete all as specified and directed. |
| 69 | S&F in repair starting relay current type suitable for compressor of water cooler capacity150/150,60/120 and 40/80 litre capacity complete all as specified and directed. |
| 70 | S&F in repair over load Protector suitable for compressor of water cooler 150/150,60/120 and 40/80 capacity complete all as specified and directed |
| 71 | S&F in repair thermostat switch with knob suitable for compressor of water cooler capacity 150/150,60/120 and 40/80 litre capacity complete all as specified and directed |
| 72 | S&F in repair PVC float valve of size 15 mm assy alongwith ball with complete accessories for water cooler any capacity of size 15 mm dia complete all as specified and directed. |
| 73 | Supply and repalcement of Self closing water tap 15 mm dia chromium plated inner/outer thread as per sample for water cooler cap[acity 150/150,60/120 and 40/80 litrecapacity complete all as specified and directed. |
| 74 | S&F in repair capillary tube of suitable length as per existing size for water cooler capacity 150/150,60/120 and 40/80 litre capacity complete all as specified and directed. |
| 75 | Taking out old u/s copper conductor cable lead from water cooler any capacity and supply and fixing new copper conductor cable for water cooler lead size 2.5 sqmm 3 core AC, 50 Hz, PVC sheathed and overall PVC insulated complete all as specified and directed. |
| 76 | Taking out old US plug top from water cooler any capacity and S & F of new plugtop of 15 Amp complete all as specified and directed. |
| 77 | Taking out old US PVC drain pipe from water cooler any capacity and S & F new PVC drain pipe with clamp of size 40 mm dia for water cooler complete all as specified and directed. |
| 78 | Taking out old U/S top cover gasket of water cooler 80/120/150 litre capacity ( storage capacity) and supply and fixing new gasket complete all as specified and directed. |
| 79 | Taking out old unserviceable top cover holding clamp of water cooler of any capacity and supply and fixing new holding clamp of suitable size complete all as specified and directed.. |
| 80 | M&L for testing the leakage in system by charging of Nitrogen Gas up to 300 PSI, repairing of leakage spots/Joints with gas welding work, cleaning and flushing the complete water cooler with gas, making the system leak proof, vacuuming the complete system complete all as specified and directed. |
| 81 | Supply and replacement of condensing coil suitable for Water Cooler of capacity 40/80,60/120,150/150 Ltrs as per sample including welding/soldering, at site complete all as specified and directed. |
| 82 | Supply and replacement of S.S Drain Tray suitable for Water Cooler of capacity 40/80,60/120,150/150 Ltrs as per sasmple kept complete all as specified and directed. |
| 83 | Repair to RefreigeratorM&L for removing burnt/defective sealed compressor unit of any make from any type and Capacity of 165 to 200 Ltrs refrigerator by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing compressor sealed unit including necessary brazing work as required new sealed compressor unit complete all as specified and directed. |
| 84 | All as per item No. 83 above but compressor suitable for refrigerator capacity of 286 to 320 Ltrs complete all as specified and directed. |
| 85 | M&L Checking the unserviceable Refrigerator of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete all as specified and directed. |
| 86 | Supply only freezer/ice chamber suitable for 165 to 320 ltrs capacity Refrigerator complete all as specified and directed. |
| 87 | Supply only relay current type and thermal over load protector suitable for compressor complete all as specified and directed. |
| 88 | Supply only thermostat auto defrost type suitable for any make and any capacity Refrigerator complete all as specified and directed. |
| 89 | Supply only capillary tube including brazing work of suitable length as per existing size for refrigerator any make and any capacity complete all as specified and directed. |
| 90 | M&L for Heater Coil for refrigerator of size 165 Ltr to 320 Ltr complete all as specified and directed. |
| 91 | S&F in repair New PCB for refrigerator of size 165 Ltr to 320 Ltr complete all as specified and directed. |
| 92 | S&F in repair Sensor for refrigerator of size upto 320 Ltr complete all as specified and directed. |
| 93 | S&F in repair Frost free Blower motor for refrigerator of size upto 320 Ltr complete all as specified and directed. |
| 94 | S&F in repair Thermal fuse for refrigerator of size upto 320 Ltr complete all as specified and directed. |
| 95 | S&F in repair Bi-Metal for refrigerator of size upto 320 Ltr complete all as specified and directed. |
| 96 | S&F in repair Defrost Timer for refrigerator of size upto 320 Ltr complete all as specified and directed. |
| 97 | S&F in repair Condensor coil for refrigerator of size 165 Ltr to 320 Ltr complete all as specified and directed. |
| 98 | S&F in repair Filter Strainer for refrigerator/ water cooler of complete all as specified and directed. |
| 99 | S&F in repairs bulbs 15 Watts pin/screw type complete all as specified and as directed. |
| 100 | Repair to Deep FreezerM&L for removing burnt/defective sealed compressor unit icluding brazing work of any make from Capacity 155 to 320 Ltr of Deep freezer by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit complete all as specified and directed. |
| 101 | M&L for testing the leakage in system by charging Nitrogen Gas up to 300 PSI. Repairing the leakage spots/Joints with welding work including supply and replacement of filter pencil type copper and capillary tube of existing dia & length. Making the system leakproof vacuuming the system complete all as specified and directed. |
| 102 | M&L Checking the unserviceable Deep Freezer of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete Note:- petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department complete all as specified and directed. |
| 103 | S&F in repair relay current type and over load protector suitable for compressor complete all as specified and directed.Make: Danfos/Ind Foss or equivalent as approved by GE. |
| 104 | S&F in repair thermostat auto defrost type suitable for any make and any capacity Deep Freezer complete all as specified and directed. |
| 105 | S&F in repair Blower motor for Deep Freezer 4x4 complete all as specified and directed. |
| 106 | S&F in repair capillary tube of suitable length as per existing size for Deep freezer any make and any capacity complete all as specified and directed. |
| 107 | S&F in repair new Axial fan motor with Condenser motor (Rotary/Axial fan) suitable for any type and any capacity deep freezer complete all as specified and directed.Make: AUE/Cool Blow/Universal/ Frac master or equivalent as approved by GE. |
| 108 | S&F in repair starting capacitor suitable for Deep freezer suitable for any type and any capacity deep freezer complete all as specified and directed. |
| 109 | Repair to Voltage StabilizerS&F replacement of Voltage stabilizer 1 KVA input voltage range 130 volt to 270 volt and output voltage 220 volt to 230 Volt AC + 2% variation of voltage complete with accessories etc complete all as specified and directed. |
| 110 | All as per Item No.109 above but Capacity 2 KVA |
| 111 | All as per Item No.110 above but Capacity 4 KVA |
| 112 | All as per Item No.110 above but Capacity 5 KVA |
| 113 | Dismantling and taking out voltage stablizer transformer unit, upto 3 KVA capacity, electric circuit board, all cable connections, complete overhauling of the system including repairing/replacement of push on switch,PCB, transistor, capacitor, relay transistor, diode, condenser, zener, pre-set, IC, 12 volt transformer, 24 Volt transformer, voltmeter, PVC connector, indicator lamp, cutout, MCB, and any other parts as required for proper functioning of stabilizer complete alongwith testing, commissioning including transportation from site to workshop and back complete all as specified and as directed. |
| 114 | All as per Item No.113 above but Capacity 4 & 5 KVA |
| 115 | S&F 1100 volts grade , heavy duty cable with PVC insulated, aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed, flat or circular of size 2 core x 6 sqmm with IS 694 : 2010, incl casing cappingcomplete all as specified and as directed. Please Enable Macros to View BoQ information |