| 1 | Taking down carefully aluminium / copper point wiring (light / fan / socket or power) complete including fitting such as switches, ceiling roses, socket, light fittings, regulators etc complete and making good disturbed surfaces of walls, floors complete all as specified and directed. |
| 2 | Taking down unserviceable Submain of any size as directed. |
| 3 | Taking down main switch / DB as directed. |
| 4 | M & L for concealed point wiring complete with 1.5 sqmm single core multistranded copper conductor FRLS, PVC insulated and unsheathed cable 650 /1100 volts grade drawn through & including PVC conduit, medium grade with accessories like bends, tees, junction boxes etc fix on wall or ceiling surfaces all as specified including 1.5 sqmm, FRLS type, copper multistranded cable as earth wire including sunken type pressed steel terminal boxes of thickness 1.6 mm thick and plastic laminated white / coloured top sheet cover 3.0 mm thick for :One light / fan / call bell point controlled by one, one way switch. |
| 5 | All as per Ser item No 4.00 above but for 5 amps socket on independent board complete all as specified and directed. |
| 6 | All as per Ser item No 4.00 above but for 5 amps socket on same board complete all as specified and directed. |
| 7 | All as per Ser item No 4.00 above but with 2.5 sq mm cable for 15 amps switch socket combination outlet on independent board complete all as specified and directed. |
| 8 | S & F switch Piano 5 Amps, flush button type, SP, one way, 230 Volts, AC complete all as specified and directed. |
| 9 | Supply & fixing switch piano flush type single pole 15 Amps complete all as specified and directed. |
| 10 | Supply & fixing socket outlet 5 Amp flush button type complete all as specified and directed. |
| 11 | Supply & fixing switch piano single pole bell push complete all as specified and directed. |
| 12 | Supply & fixing bell electric (dingdong) 230 volt, SP complete all as specified and directed. |
| 13 | Supply & fixing decorative wall light fixture made up of polycarbonate/glass all as specified and directed. |
| 14 | All as per item 13.00 here-in-before but 6 pin 5/15 Amps multi type complete all as specified and directed. |
| 15 | M & L ceiling rose surface bakelite 65 x 50 mm three terminals complete all as specified. |
| 16 | Supply and fix ceiling fan regulator BLDC/Electronic rotary Step type single phase A/C 230 volts all complete as specified and directed. |
| 17 | Supply & fixing of 20 Watt Batten luminaire with Polycarbonate Housing with high quality opal finish diffuser. The luminaire should have a CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 2000 nominal lumens and an System efficacy of at least 100 lumen/watt and maximum system wattage of 20 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <10% and suitable for an operating voltage range of 140-270V AC. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. |
| 18 | Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of cap 20A complete all as specified and directed. |
| 19 | M & L for sub main wiring with two single core PVC insulated and unsheathed cable 4 sqmm with multi stranded copper conductor, FRLS type cable drawn through and including PVC concealed conduit of 20mm in size complete with all accessories alongwith provn of 4 sqmm PVC insulated and unsheathed, multi stranded copper conductor, FRLS type cable as earth wire complete all as specified and directed. |
| 20 | M & L for sub main wiring with two single core PVC insulated and unsheathed cable 6 sqmm with multi stranded copper conductor, FRLS type cable drawn through and including PVC concealed conduit of 25mm in size complete with all accessories alongwith provn of 6 sqmm PVC insulated and unsheathed, multi stranded copper conductor, FRLS type cable as earth wire complete all as specified and directed. |
| 21 | M & L for sub main wiring with four single core PVC insulated and unsheathed cable 10 sqmm with multi stranded copper conductor , FRLS type cable drawn through and including PVC concealed conduit of suitable size complete with all accessories alongwith provn of 2 run of 6 sqmm PVC insulated and unsheathed ,multi stranded copper conductor , FRLS type cable as earth wire complete all as specified and directed. |
| 22 | Supply and fix MCB DB, TPN 6 way double door Vertical type suitable for mounting of MCCB as incomer with suitable 200 amps rated bus bars, Neutral links, blanking plates complete all as specified and directed. |
| 23 | Supply & fixing MCCB 3 pole/4 pole of capacity 63 Amps with breaking capacity 16 Kilo Amps including all electrical connections and fixing arrangment complete all as specified and directed. |
| 24 | Supply and fix MCCB 100 Amps 4 pole 415 Volt, 25 KA breaking capacity complete all as specified and directed. |
| 25 | Supply and fix MCB DB, TPN 4 way double door with suitable 200 amps rated bus bars, Neutral links, blanking plates complete all as specified and directed. |
| 26 | Supply and fix Sheet metal DB, double door, SPN 8 way for MCB, 240 volt with 200 amps rated bus bar, neutral bar / connectors suitable copper thimbles, lugs etc complete all as specified and directed. |
| 27 | S/F MCB TPN 40 Amps 415 volts complete all as specified and directed. |
| 28 | S/F MCB TPN 63 Amps 415 volts complete all as specified and directed. |
| 29 | Supply & fixing MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed. |
| 30 | S & F MCB SPN, 240 volts, 40 to 63 Ampere, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed. |
| 31 | M&L for earthing complete with GI steel earth plate electrod 60x60cmx6.00mm thick bouried directly in ground /earth pit not less than 2.25m deep below the ground level with top edge of the plate not less than 1.5 m below the normal ground level connected to test point by using GI wire of dia 4 mm as earthing lead soldering/revated to earth plate at one end and connected DB by means of nut, bolts etc complete with PCC pit (1:3:6) type GI cover with handle funnel with watering pipe wire mess GI protection pipe for earthing lead all complete as specified and as per electric plate No.5 of SSR Part I Please Enable Macros to View BoQ information |