| 1 | DSR Item No. 1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 2 | 3 x 1.5 sq. mm |
| 3 | 3 x 2.5 sq. mm |
| 4 | 3 x 4 sq. mm |
| 5 | DSR Item No.1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 6 | 25 mm |
| 7 | DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 8 | Single pole |
| 9 | Double pole |
| 10 | Triple pole and neutral |
| 11 | DSR item No.1.23 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 12 | 5/6 amps switch |
| 13 | 3 Pin 5/6 A. socket outlet |
| 14 | 15/16 amps switch |
| 15 | 6 Pin 15/16 A. socket outlet |
| 16 | DSR Item No.1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 17 | Supply & Erection of 3 mm thick white glazed bakelite sheet on existing M.S. box. The job includes the cost of sheet and making holes & cutting and fixing with screws as required to complete the job. The Bakelite sheet should be of make Super Hylam / Formica / GreenLam make only. |
| 18 | Supply and Erection of B.L. Holder of make Anchor Panta / Havells Reo/ Gold Medal Essenza ISI marked on existing Jn. Box / Wooden block including making connection etc. as required. |
| 19 | Supply and Erection of electronic step type socket type fan regulator in existing B.L. Sheet including making connection and petty material reqd. to complete the job. The fan regulator should be of Anchor Panta/ Havells Reo/ Gold Medal Essenza make only. |
| 20 | DSR item No.9.2.4 Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, (As per Complete Item No. 9 of the DNIT) |
| 21 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 22 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, (As per Complete Item No. 10 of the DNIT) |
| 23 | Size 12” Sweep 900 RPM with louver of Havells make Turbo Force SP / Orient make Industrial Heavy Duty / Crompton make HDEF EXHD 300-6-1/ Bajaj make Supreme PLUS/ Usha (Turbo HDEF) only |
| 24 | DSR item no.8.16.3LEDFlood powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt)Supplying,installation,Testing&CommissioningofFlood Light,powdercoatedpressuredie cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%,Input voltage: Input voltage: 140-270 Volt AC,(As per Complete Item No. 11 of the DNIT) |
| 25 | 100 Watt |
| 26 | DSR item No.8.9.5LEDBattenlight(Systemlumenefficacy≥105<120lm/Watt)Supplying, installation, Testing & Commissioning of LED surfacemountedBatten light of following bodymaterial and construction as per IS : 10322 withdriver(Replaceable) as per the requirement with Driver efficiency >85% ,(As per Complete Item No. 12 of the DNIT) |
| 27 | 18-22Watt |
| 28 | DSR item no. 8.7.10LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., (As per Complete Item No. 13 of the DNIT) |
| 29 | 36 watt |
| 30 | Supply and laying of XLPE insulated PVC sheathed Aluminium conductor cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid direct on surface with the help of M.S. clamp of suitable thickness. (As per Complete Item No. 14 of the DNIT) |
| 31 | Size 16 Sq.mm 2 Core XLPE Al. Arm. Cond. Cable |
| 32 | Supply and laying of XLPE insulated PVC sheathed Aluminum conductor cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing RCC/Hume/DWC/ Metal pipe. (As per Complete Item No. 15 of the DNIT) |
| 33 | Size 35 Sq.mm 3.5 Core XLPE Al. Arm. Cond. Cable |
| 34 | DSR item No.2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 35 | 100A,30KA,FPMCCB |
| 36 | 125A, 36KA,TPMCCB |
| 37 | 200A, 36KA,TPMCCB |
| 38 | Supply & erection of size 600mm (24” sweep) wall mounted heavy duty double ball bearing Air Circulator fan of Almonard / Crompton / Havells/ Orient/ Usha/ Bajaj make only, oscillating type complete with blades with sturdy close mess guard etc. (As per Complete Item No. 17 of the DNIT) Please Enable Macros to View BoQ information |