| 1 | Cutting in earth work and disposal of excavated earth work upto a lead of 20 metre IN ALL KIND OF SOIL |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand) : 4 graded stone aggregate 20 mm nominal size) |
| 3 | cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:2:4 (1 cement : 2 coarse sand) : 4 graded stone aggregate 20 mm nominal size) |
| 4 | Providing and laying cement conc. In retaining wall ,return walls ,walls(any thickness)including attached pilaster,column ,piers,abutment pillares post ,struts ,butterses ,strin g or lacing course ,parapets ,coping bed block anchor blocks ,plain window sill, fillets, sunken floor etc. up to floor five lvl ,excluding the cost of centering ,shuttering and finising1:4:8(1 cement :4Course sand ):8graded stone aggregate stone aggregate 40mm nominal size) |
| 5 | Centering and shuttering including strutting ,propping etc and removal of form work for Suspended floors, roofs, landings, balconies and access platformWalls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.Suspended floors, roofs, landings, balconies and access platform |
| 6 | Supplying filling,spreading&levelling stone boulder of size range 5cm to 20cm ,in recharge pit,in the required thickness ,for all leads & lifts ,all complete as per direction of Engineer –in charge . |
| 7 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 8 | 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall. |
| 9 | Laying of GI pipes ,over flow &outlet,inlet(100mm(light class) 40.00in all civil structure complete in all respect |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Hard drawn steel wire |
| 11 | Providing & Fixed Display Board Of Size 3’-0”X2’-0” (Minimum )Indicating Name Of Work ,Name Of Head ,Estimated Cost ,Date Of Award ,Date of Start, Date Of Completion And Expenditure Of Work On Site Of Work At Promonent Place . Please Enable Macros to View BoQ information |