| 1 | PUNJAB WATER RESOURCES DEPARTMENT Madhopur Division UBDC Gurdaspur NAME OF WORK :- Estimate for Laying of UPVC pipeline off taking at RD 15020/L of Babehali disty. Name of Firm Sr.No Description Unit QUANTITY Rate (in figures) Rate (in Words) |
| 2 | Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. Earth work upto 1.5 m. Depth for. All classes of soil except rocky |
| 3 | Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. |
| 4 | First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth |
| 5 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 6 | 10 mm thick cement plaster with cement mortar 1:4 on bed & top of side walls |
| 7 | Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design |
| 8 | Providing and fixing of Alfa valve of 180 mm dia complete Including all tax and charges |
| 9 | Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications 300 mm o/d UPVC pipe of 2.5 Kgf. / sqcm |
| 10 | Providing & fixing 180 mm Dia. Equal Tee (6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge |
| 11 | Providing & fixing 180 mm Dia. Short OR long Bend (90 Degree)(6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge |
| 12 | Providing & fixing 180 mm Dia. Socket (6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge. |
| 13 | Providing & fixing 180 mm Tail end point 6kg with M.S./C.I. flange(6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge. |
| 14 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge)(A) Class PN-1 as per ISI (g) 140mm i/d Sluice Valves flanged |
| 15 | Providing & fixing Single air valve ISI Marked as per IS-14845 including jointing all carriages complete (d) C.I Single air valve Screwed(Size 50mm) |
| 16 | Providing & fixing 180x50 mm Dia. MS Service saddle (6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge |
| 17 | Providing, laying, fixing, testing and commissioning of Class heavy duty MS Pipe conforming to IndianStandard IS:1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nutsbolts, gasketsetc. fixing the pipe on the wall /ceiling with suitable clamp sandpainting with two or more coats of synthetice paint of required shade complete in all respects. (d)50mm internal diameter |
| 18 | Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. Size 0.6 m. x 0.6 m. |
| 19 | Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. Size 0.9 m. x 0.9 m |
| 20 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete |
| 21 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 22 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 23 | Any other Item. Compatibility Report for Harpur.xls Run on 28-03-2025 12:10 The following features in this workbook are not supported by earlier versions of Excel. These features may be lost or degraded when you save this workbook in an earlier file format. Minor loss of fidelity # of occurrences Some formulas in this workbook are linked to other workbooks that are closed. When these formulas are recalculated in earlier versions of Excel without opening the linked workbooks, characters beyond the 255-character limit cannot be returned. 2.0 'boq 1'!B21 'boq 1'!C22 |