Housing Urban and Rular Development Boards / Undertakings / PSU Closing in 0 days TDR #54758509

Tender For Internal Electrification & Electrical Connection Work Under Upgradation Work At Lalganj Bus Depot, District-Pratapgarh.

Issued by Boards / Undertakings / PSU · Lalganj, Uttar Pradesh
Tender Value
40 Lakhs
Estimated cost
Bid Submission
31 Mar 2026
0 days left
EMD
80000
Bank guarantee accepted
Document Fee
1770
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lalganj → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Internal Electrification & Electrical Connection Work Under Upgradation Work At Lalganj Bus Depot, District-Pratapgarh.

BOQ

Name of Work:- INTERNAL ELECTRIFICATION & ELECTRICAL CONNECTION WORK UNDER UPGRADATION WORK AT LALGANJ BUS DEPOT, DISTRICT-PRATAPGARH.
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
2Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
3Wiring for circu it/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X2.5 sq. mm + 1X2.5 sq. mm earth wire
4Wiring for circu it/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
5Wiring for circu it/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
6Wiring for circu it/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
7Wiring for circu it/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
8Wiring for circu it/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 10 sq. mm + 2X6 sq. mm earth wire
9Wiring for circu it/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
10Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
11Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
12Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
13Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
14Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm
15Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
16Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch
17Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
18Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet
19Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
20Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet
21Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Bell push
22Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
23Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
24Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
25Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required 3 Module (100mmX75mm)
26Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required 6 Module (200mmX75mm)
27Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required 8 Module (125mmX125mm)
28Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required 12 Module (200mmX150mm)
29Installation .Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing up to two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
30Supplying and fixing call bell/ buzzer suitable for single phase, V, complete as required.
31Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
32Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Up to 450 mm sweep
33Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
34Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
35Supplying & fixing suitable size Gl box with modular plate and cover in fronton surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
36Supplying and fixing PVC batten/ angle holder including connections etc. as required.
37Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A.30KA.FPMCCB
38Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) 6 way , Double door
39Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) 12 way , Double door
40Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) 4 way (4 + 12), Double door
41Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) 6 way (4 + 18), Double door
42Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door
43Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
44Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
45Supplying and fixing following rating, double pole, the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A
46Supplying and fixing following rating, double pole, the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
47Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 63A
48Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
49Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
50Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
51Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
52Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
53Supplying and laying 6 SWG G.l. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with Gl thimble etc. as required.
54Supplying and laying 25 mm X 5 mm G.l. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.l. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.l. nut bolt & spring washer spaced at 50mm)
55Providing and fixing 25 mm X 5 mm G.l. strip on surface or in recess for connections etc. as required.
56Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing as required.
57Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Up to 35 sq. mm
58Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Up to 35 sq. mm
59Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Up to 35 sq. mm (clamped with 1mm thick saddle)
60Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 3-1/2 X 35 sq.mm
61Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 4 X 16 sq. mm (28mm)
62Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 6 sq. mm (19mm)
63Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm)
64Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.(DSR Civil 2023 Item no. 10.18.)
65Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factornot less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts,washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
66Supply of AC 300mm Sweep, 230/250 Volts, 50 Hz exhaust fan (Heavy Duty) with blades,cover etc. complete as required.
67Supply of AC 200mm Sweep, 230/250 Volts, 50 Hz exhaust fan (Light Duty) with blades,cover etc. complete as required
68Supply of Factory made 12 to 20 Watt LED Bulb fitting,cool day light,(65000 K temp.) suitable for Batton/Angle holder including making connection.Complete in all respect.
69Supply of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.CAT-AAA
70SuppLY and fixing of 18-22W LED Batten fitting with Extruded||Aiuninumn housing, spevial polycarbenate difluser for glare freeIlght distnbution and suitable mounting for on both surface & suseda, Compelete in all respect. 1980-2420 syslem lumens, >l10 Lm/W, PF>0.95, THD<10%, CRI > CAT-AA 80, with 3 year wafrarlee
71Supply and fixing of IP 20, Front Lit, Mid Power SMD type LEDLight, Recess mounting round'square 12Watt to 15Watt, with cut outmin 125 mm, heiglht min 40 mn, LED Downlighter having Powderlcoated de cast aluminium housing with heat sink,, diffuser/Reletor and driver set, suitable for 24 Hr Continuous Operation, completc in all respat 1440-1800 Sy stem lumens, >120 Lm W, PF0 95, THI) <10% at CAT:AAAull loed, CRI >80, >300V over voltage protection, 2.5 KV internalSurge Protection, with S ycar warrantee
72Supply and fixing of IP 20, Front Lit, Mid Power SMD type LED| Light, recess Surface mounting round 18 Watt to 20 Watt, Cut out Min 150 mm, Height Min 40 mm,, LED Down Lighter having Powder coated die cast aluminium housing with heat sink, High purity / transmi_ivity UV Stabilized Non yellowish diffuser/ Reflector for uniform light distribution, detachable driver set,suitable for 24 Hr Continuous Operation, Complete in All respect. 2160-24(0 systen lumens, >l20 Lm/W, PF>0.95, THD <10% at CAT-AAA full load, CRI >80, ,>300V over voltage prolection, 2.5 KV internalSurge Proteclion, with 5 years warranlee.
73Supply and fiNng of LED Tube Light with heavy duty Metal Boxtype Tebe Light titting Ix22 watt suitable for uplo Ix 22 watt LEDPolycarbwwte tue light complete Including tube suitable for bethsurface & suspended conplete in all respect 2%20 sstenn lumens >120 LmW, PF0 95, THD< 10%, CRI >80, CAT-AAAsheet thick ness min 0 Rnm, Tube with aluminiun heat sink, >00V over lage protevtion, 2.5 KV internal Surge Protetion, withST atrantee
74Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade. 16 sq. mm 4 core
75Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade. 35 sq. mm 3-1/2 core
76Supply & Fixing of LAN socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
77Supply and fixing of Three phase multifunctional electronic energy meter 10 to 60 Amp. Capacity fitted in intergral box on wall complete in all respect.
78Supply of aluminium conductor XLPE insulated armoured served sheathed cables 1100 Volts grade. 16 sq. mm 4 core
79Supply of aluminium conductor XLPE insulated armoured served sheathed cables 1100 Volts grade. 10 sq. mm 4 core
80Supply of aluminium conductor XLPE insulated armoured served sheathed cables 1100 Volts grade. 35 sq. mm 3-1/2 core
81Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB' s (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat B Only.Incoming 100 Amp MCCB -1 No Outgoning 63 Amp. MCCB-2 Nos.+(100 AMP. MCCB-4 NOS.+63 AMP FPMCB-4NOS.) AS BUILDING PANEL
82SUPPLY, IN STALLATION AND COMISSIONING OF PANEL BOARD ( MCCB TYPE) Incoming 100 Amp MCCB -1 No Outgoning 63 Amp. MCCB-2 Nos.+(100 AMP. MCCB-4 NOS.+63 AMP FPMCB-4NOS.) AS BUILDING PANEL
83Supply & fixing of fire extinguisher, ABC Type 4.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
84Supply & fixing of CO2 type fire extinguisher, 4.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
85Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter \\"FIRE\\" in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer.
86Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect.
87Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with Double arm bracket (1 Mtr length each ) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect.
88Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect.40 A TPN
89Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 52 watt to 72 Watt. Confirming to IP66 Protection complete in all respect.CAT- AAA
90Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above Protection complete in all respect.CAT- AAA
91Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 140 to 150 Watt. Confirming to IP 66 Protection complete in all respectsCAT- AAA Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 54758509
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 40 Lakhs
LAST DATE 31-03-2026
Authority
Authority Name Uttar Pradesh Housing And Development Board
Work Description Tender for Internal Electrification & Electrical Connection Work Under Upgradation Work At Lalganj Bus Depot, District-Pratapgarh.
Basic Detail
Tender No 424/L-11/14 Dated 11.03.2026
Bidding Type Tender
Location
City Lalganj
State Uttar Pradesh
Key Dates
Publish Date 20 Mar 2026
Submission Date 31 Mar 2026
Open Date 31 Mar 2026
Finance
Tender Value 40 Lakhs
Tender Fee 1770
EMD 80000
Exemption Not Available
Document List
1.pdf
2.pdf
304a867b-7b78-448f-8141-78a304b053d8.html
BOQ_2102395.xls
Tendernotice_1 (8).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

1.pdf

pdf

2.pdf

html

304a867b-7b78-448f-8141-78a304b053d8.html

xls

BOQ_2102395.xls

pdf

Tendernotice_1 (8).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender