| 1 | Bill of Quantities |
| 2 | Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.(Ordinary Rock-manual means,upto 3m depth,Not Requiring Blasting) |
| 3 | PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.) |
| 4 | Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications.PCC Grade M20. |
| 5 | Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia PVC/AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications. |
| 6 | Hand Packed stone filling in back of wallls including cost of all materials, royality, T&P etc. complete as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications) |
| 7 | Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal upto 2000 metres. (Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 2000m.) |
| 8 | Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. A PCC Grade M15 Case II PCC Grade M15 using batching plant transit mixer & manual placing |
| 9 | Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. PCC Grade M20 using batching plant transit mixer & manual placing |
| 10 | Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications.Case II PCC Grade M25 using batching plant transit mixer & manual placing |
| 11 | RCC Grade M25 using batching plant transit mixer & manual placing Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications |
| 12 | Providing & making Gabion structure with Mechanically Woven Double Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per IS 16014:2012, MORT&H Clause 2500, of required size, Mesh Type 10x12 (D=100 mm with tolerance of ± 2%) Zinc coated, Mesh wire diameter 3.0 mm, mechanically edged/selvedged with partitions at every 1m interval and shall have minimum 10 numbers of openings per meter of mesh perpendicular to twist, tying with lacing wire of diameter 2.2 mm, supplied @3% by weight of Gabion boxes, filled with boulders with least dimension of 200 mm, as per drawing, all complete as per direction of Engineer-in-charge. |
| 13 | Cement plum Masonry with 40% plum & 60% 1:3:6 cement concrete including supply of all material, labour, T&P etc. required for proper completion of the work. as per drawings and technical specifications Clause 802, 803, 1202 & 1203 of MORD Specifiction |
| 14 | Random Rubble Masonry Stone masonry work in cement mortar 1:3 in foundation complete as drawing and Technical Specification |
| 15 | Laying Cement Concrete Pipe NP3 (burried conduits) on first class bedding of granular material including fixing collar with cement sand mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonary work in head wall and parapets.300 mm dia |
| 16 | Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications. |
| 17 | Removal of Unserviceable Soil with Disposal upto 3000 metres (Removal of unserviceable soil including excavation, loading and disposal upto 3000 metres lead but excluding replacement by suitable soil which shall be paid separately as per clause 305..) |
| 18 | Supply & Fixing layer of Geo-Jute mat with Spraying of seeds of lemon grass/Dedonis/vetiver etc, including all cost of material, labour and T&P required to complete the work in all respect, with the following properties a. Material 100% natural, b. Weight 500 GSM, c. Minimum Breaking Load along Machine Direction (warp way)- 10(Kn/m) Cross Direction (warp way) 10.0 (Kn/m), d. Max elongation at break (in %): Machine Direction (warp way)-10, cross direction (warp way)-12 |
| 19 | Maintenance of Slab type Culverts by way of clearing, Cleaning, Erosion repair,repairs to cracks, parapet walls and Protection works as per drawing and technical specification Clasue 1908 |
| 20 | Hill Side Drain Clearance (Removal of earth from the choked hill side drain and disposing it on the valley side manually) |
| 21 | Clearing and Grubbing Road Land .(Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.) by manual means (In area of light jungle) |
| 22 | Removal of Unserviceable Soil with Disposal upto 3000 metres (Removal of unserviceable soil including excavation, loading and disposal upto 3000 metres lead but excluding replacement by suitable soil which shallbe paid separately as per clause 305..) |
| 23 | Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.(Ordinary Rock-manual means,upto 3m depth,Not Requiring Blasting) |
| 24 | Supply and installation of non-woven geotextile having mass/unit area - 250gsm over the slope to be treated including all cost of labour,material and T&P required for proper completion of work |
| 25 | Hand Packed stone filling in back of wallls including cost of all materials, royality, T&P etc. complete as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications) |
| 26 | Providing & making Gabion structure with Mechanically Woven Double Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per IS 16014:2012, MORT&H Clause 2500, of required size, Mesh Type 10x12 (D=100 mm with tolerance of ± 2%) Zinc coated, Mesh wire diameter 3.0 mm, mechanically edged/selvedged with partitions at every 1m interval and shall have minimum 10 numbers of openings per meter of mesh perpendicular to twist, tying with lacing wire of diameter 2.2 mm, supplied @3% by weight of Gabion boxes, filled with boulders with least dimension of 200 mm, as per drawing, all complete as per direction of Engineer-in-charge. |
| 27 | Excavation in Soil by Manual Means. (Excavation for roadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto 2000 metres.) |
| 28 | Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. A PCC Grade M15 Case II PCC Grade M15 using batching plant transit mixer & manual placing |
| 29 | Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications.Case II PCC Grade M25 using batching plant transit mixer & manual placing |
| 30 | Stone masonry work in cement mortar 1:3 in foundation complete as drawing and Technical Specification (b)Random Rubble Masonry. |
| 31 | Filling Pot- holes and Patch Repairs with - Bituminous concrete, 40mm. ( Removal of all failed material, trimming of completed excavation to provide firm vertical faces, cleaning of surface, painting of tack coat on the sides and base of excavation as per clause 503, back filling the pot holes with hot bituminous material as per clause 504, compacting, trimming and finishing the surface to form a smooth continuous surface, all as per clause 3004.2) Please Enable Macros to View BoQ information |