| 1 | EARTHING |
| 2 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 3 | Supplying and fixing cosmos earthig electrode systems. |
| 4 | COSMOS ROMA 40mm DIA 3 Mtrs LENGTH WITH MOISTURE ENHANCER 25 Kg. |
| 5 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 6 | 45 mm dia (OD-45 mm & ID-40 mm nominal) |
| 7 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 8 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 9 | upto 50 Sqmm |
| 10 | Supplying of Cables. |
| 11 | Supplying of following size ISI marked PVC/XLPE insulated and PVC sheathed aluminium grade with armoured as required.(Make:Finolex,Gloster,Polycab and Havells with 18 months warranty from the date of supply) |
| 12 | 4x16 sq mm |
| 13 | 3.5x50 sq mm |
| 14 | MV CABLE JOINTING & END TERMINATION |
| 15 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 16 | 4 X 16 sq. mm (28mm) |
| 17 | 3.5 X 50 sq. mm (28mm) |
| 18 | POLE ERECTION |
| 19 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. |
| 20 | 10 mtr Octagonal street light pole Foundation, steel Fabrication and Erection with M-20 concrete labour and fixing of street light fittings internal wiring with crane rent etc. as required. |
| 21 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 22 | Cold twisted bars |
| 23 | SUPPLY OF POLES |
| 24 | Manufacturing, Supply and Installation of Octagonal /GI type wall street light bracket made of approved type and design with 500 mm overhanging from street light pole painting & not less than 9 Kg with one coat of Anti-corrosive Primer and two or more coats of automobile grade metallic paint of approved brand and shade, etc as reqd |
| 25 | Supply and fixing of Galvanized 1900mm T Bracket with 100mm dia head frame suitable arrangements for non integral type flood lights (3(or)4 No's) |
| 26 | Supply of following size meters hot Tip galvanized, octagonal pole with bottom and top base plate flood light fixing pole 3mm thick etc. as required. |
| 27 | Supply of 10 mtrs hot tip galvanized, 4mm thick octagonal pole with bottom 200mm A/F top 100mm A/F 310mmx310mmx20mm base plate with hot tip ‘J’ type EN8 grade CNC threaded foundation bolt size: M 24mm x 850mm - 4Nos, projected bolt length-150mm including L max connector junction box with hylam sheet board with 12way backlight connector. |
| 28 | Fabrication, supply of out-door feeder pillar type made out of not less than 2.2 mm thick MS sheet and angle iron base frame with hinged door on both side and gowden locks welded on the door i/c painting connection inter-connection etc. as per CPWD specifications (Part IV & V) of following size and providing and fixing following switch gears with cable entry boxes for both incoming and outgoing cables termination, glands, interconnection, connections powder coated painting, earthings , including of all erection, Labelling of incoming and outgoing feeders & transport charges etc., as required. The panel drawing should be submitted before execution of the works. (Make: L&T/Legrand/Schneider/Siemens). \\"Specification for Microprocessor based MCCB Conforms to IS/IEC 60947-2 & IEC 60947-2, Ics=100% of Icu,Suitable for Isolation,Adjustable Overload from 0.4-1.0 X In,Adjustable short circuit from 1.5-8XIr, Inbuilt Instantaneous protection,Provisional of thermal memory : ON/OFF,Variable trip class at 7.2 lr & 6 lr, Front LED indication of Over load (Ready, Over load pre-alarm & Overload),Provision of Manual, Rotary or motorized versions,Wide range of snap fit internal and external accessories\\"\\"Specification for Thermal Magnetic MCCB Conforms to IS/IEC 60947-2 & IEC 60947-2, Ics=100% of Icu,Suitable for Isolation,Adjustable Overload from 0.8-1.0 X In,Adjustable short circuit from 6-10 XIn, Provision of Manual, Rotary or motorized versions,Wide range of snap fit internal and external accessories |
| 29 | Supply, Installation of outdoor type cubicle fabricated out of 2.2 mm thick MS sheet free standing totally enclosed dust and vermin proof and locking arrangement of the board with size of 900mm x 700 mm x 250 mm deep (Nominal) double door type with 1)4P, 125A MCCB as incomer - 1No , 2) 4P 6-32A MCB - 4No 3)Timer and Contactor as a outgoing with necessary indication lamp and Hylam sheets for rail arrangements, connection and wirings including panel erections etc. as required. |
| 30 | Supplying and fixing of following size ISI marked PVC insulated and PVC unsheathed copper single core and multi-core shaethed bright annealed bare copper flexible cables for voltage grade 1.1 KV grade as required.(Make:Finolex,Gloster,Havells and Polycab) |
| 31 | 3x2.5 sqmm |
| 32 | Supply of Light Fixtures with Lamps |
| 33 | Supply and fixing of outdoor of LED Floodlighting for instant start, Extruded aluminium heat sink, designed to act as efficient heat dissipater – important for LED luminaires, Pressure die-cast aluminium cover on both sides for holding of extruded aluminium heat sink, Luminaire provided with heat resistant toughened glass, Control gear compartment is an integral part of luminaire, LEDs are provided with secondary lens optics to get optimum optical performance, The driver used is specially designed to have surge voltage, open/short circuit protections and Luminaire is provided with a mounting bracket fixed on pressure die-cast aluminium covers for aiming adjustment etc. as required. (Make: Bajaj, Philips, Stand LED) |
| 34 | 400W LED Flood light Input voltage : 140V to 270V AC ± 10%, Frequency :50Hz, Input power :240W , Efficiency: >85%, Viewing Angle:> 120, Lumens = 40000 lm ±10%, Colour Temp: 5700°K ±300°K, Power Factor >95, Protection : IP: 66 with External Surge protection 10kV. (Make: Bajaj, Philips, Crompton, Wipro) Please Enable Macros to View BoQ information |