| 1 | Taking down carefully copper/aluminum point wiring (light/ fan/ bell/ socket, power point etc) complete, including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors etc complete all as specified and directed Engineer-in-Chage. |
| 2 | M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn in and incl PVC Casing and capping ISI Marked with its accessories PVC boxes (upto 18 module suitble for Mylinc series of Legrand including white plates with frame upto 18 module of make suitable for Mylinc Series) for fixing switches/ socket/ regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed. Note :1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2.Wiring shall be done as per complaints recd from user only on required basis it is not necessary to do whole wiring of any whole bldg3. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, ceiling lights, bulkhead lights, bldg security light etc |
| 3 | One light point controlled by switch 5 Amp single pole one way |
| 4 | One Fan point controlled by switch 5 Amp single pole one way |
| 5 | One bell point controlled by switch 5 Amp single pole one way |
| 6 | One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch |
| 7 | One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board |
| 8 | One light point controlled by switch 5 Amp single pole two way |
| 9 | .-ditto- all as per Item No 2 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase, Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board |
| 10 | M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn in and incl PVC Casing and capping ISI Marked with its accessories with provn of PVC boxes and fixed with brass screws cup washer for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed. Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, bulkhead lights, bldg security light etc |
| 11 | One light point controlled by switch 5 Amp single pole one way |
| 12 | One fan point controlled by switch 5 Amp single pole one way |
| 13 | One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch |
| 14 | One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board |
| 15 | .-ditto- all as per ser Item No 10 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase, Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board |
| 16 | M&L for point wiring complete concealed type with two runs of 1.5 Sqmm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn through and including PVC rigid conduit not less than 20 mm dia with its accessories with Flush mounting modular metal boxes (upto 18 module suitble for Mylinc series of Legrand with and including white plates with frame upto 18 module of make suitable for Mylinc Series) for fixing switches/ socket/ regulators etc with and including 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable as earth continuity conductor to common earth & connecting to earth dolly for the following, etc complete all as specified and directed by Engineer-in-Charge. Note :1. Proper colour coding shall be adopted for wiring (For Phase - Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. Wiring shall be done as per complaints received from user 3. All points are required to earthed upto fixtures i.e. Holders, Tube lights. Wall lights, ceiling lights, bulkhead lights, bldg security light etc |
| 17 | One light point/fan point/bell point controlled by one switch with cables 1.5 sq. mm size |
| 18 | One light point controlled by two , 2 way switches , with cable 1.5 Sqmm |
| 19 | One 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq. mm size |
| 20 | One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size |
| 21 | --do-- all as per item No 20 above with but 2.5 sqmm size cable for, 3 pin socket 15 Amp |
| 22 | S&F in replacement Modular Switch, 6 Amp, one way, one Module as per existing. etc complete all as specified and directed by Engineer-in-Charge |
| 23 | S&F in replacement Modular Switch, 6 Amp, two way, one Module. etc complete all as specified and directed by Engineer-in-Charge |
| 24 | S&F in replacement Modular Switch, 16 Amp, one way, one Module as per existing. etc complete all as specified and directed by Engineer-in-Charge |
| 25 | S&F in replacement Modular Socket Outlet 6 Amp, 3 pin, combined two module etc as per existing complete all as specified and directed by Engineer-in-Charge. |
| 26 | S&F in replacement Modular Socket Outlet 6 Amp / 16 Amp - 2/3 pin combined two module as per existing etc complete all as specified and directed by Engineer-in-Charge |
| 27 | S&F in replacement Modular Bell push, 6 Amp, one module etc complete all as specified and directed by Engineer-in-Charge |
| 28 | S&F in replacement Modular Fan Regulator Fan step regulator, 120 Watt - two module etc complete all as specified and directed by Engineer-in-Charge |
| 29 | S&F bell ding dong elelctric 230V AC single pole etc complete all as specified and directed by Engineer-in-Charge |
| 30 | S&F in replacement switch piano flush type single pole, one way 5/6 Amp etc complete all as specified and directed by Engineer-in-Charge |
| 31 | S&F in replacement stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required etc complete all as specified and directed by Engineer-in-Charge. |
| 32 | S&F in replacement Socket outlet 3 Pin ,6 A etc complete all as specified and directed by Engineer-in-Charge |
| 33 | S&F Switch socket combination as per existing, 6 Amp flush type 230V AC etc complete all as specified and directed by Engineer-in-Charge |
| 34 | S&F Switch socket combination 5 Amp / 16Amp, five in one, as per existing 230V AC etc complete all as specified and directed by Engineer-in-Charge |
| 35 | S&F in replacement lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting etc complete all as specified and directed by Engineer-in-Charge |
| 36 | S&F in replacement ceiling rose 3 terminal / PVC / polycarbonate, isolated body etc complete all as specified and directed by Engineer-in-Charge . |
| 37 | Taking out old PVC/ Wooden/ metal switch board ,wire connection from the wall and fix new PVC Cutting sheet board box including connecting wire suitable for fixing switch/Socket/fan regulater of following sizes. (Note.Damaged Switch / Socket / regulator will be measured and paid Sepereately) |
| 38 | 100 x100 x 50 mm |
| 39 | 100 x175 x 50 mm |
| 40 | 200 x150 x 50 mm |
| 41 | 250 x200x 50 mm |
| 42 | 350 x300x 50 mm |
| 43 | S&F in replacement double door Sheet metal enclosures vertical type, factory made DBs 4 way, (VTPN DB's) 415 volts with provision of 63 Amps MCCB 25 KA protection class IP-43, suitable for fixing 4 pole RCCB/MCCBs, Isolators etc including prewired, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 200 Amps rated copper Busbar, With Neutral bar, Earthbar and Cable lies for Cable management, Fully shrouded, Neutral bars, Prefitted masking sheet complete all as specified and as directed. |
| 44 | S & F in replacement double door Sheet metal enclosures factory made DBs 4 way TPN, 415 volts ,protection class IP-42, suitable for fixing of MCBs, etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar, With Neutral bar, Earthbar and Cable ties for Cable management, Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. |
| 45 | S & F in replacement double door Sheet metal enclosures factory made DBs SPN, 8 way, 240 volts, protection class IP-42, Concealed in wall suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar, With Neutral bar, Earthbar and Cable ties for Cable management, Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. |
| 46 | S & F in replacement double door Sheet metal enclosures factory made DBs 4 way SPN, 240 volts ,Concealed in wall protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. |
| 47 | S&F in replacement MCB , SP, AC, 240 Volts of 06 to 40 Amp capacity 10KA, 'B' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge |
| 48 | S&F in replacement MCBs, TPN, AC, 415 volts of 63 Amps capacity 10 KA, 'B' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge . |
| 49 | S&F in replacement MCBs, SPN, AC, 240 volts of 40 Amps capacity 10 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge |
| 50 | S&F in replacement square profile LED lighting fixture , environmental friendly, energy efficient ready to use pack LED Tube light fitiing 20 Watt with LED light source 6500 K,input voltage 240V-270V with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed by Engineer-in-Charge . |
| 51 | S&F in replacement square profile LED lighting fixture with extruded , environmental friendly, energy efficient ready to use pack LED Tube light fitiing 10 Watt with LED light source 6500 K,input voltage 240V-270V with uniform light output, with all accessories including its connection with 2 core seathed cable of size 0.5 Sqmm with etc complete all as specified and directed by Engineer-in-Charge.Make: Smart bright batten or equvalent in Make. |
| 52 | S&F in replacement environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head Back-lit 10 W LED ,IP65 ,IK 08 rated product luminaire comprising of high brightness LEDs complete with all accessories prewired and including connecting up with & including twin core twisted flexible copper conductor cable of suitable size etc complete all as specified and directed by Engineer-in-Charge. |
| 53 | Supply & fix in replacemnt industrial type switch socket for Geysers with 20 Amp MCB etc complete all as specified and directed by Engineer-in-Charge. |
| 54 | S&F in replacement sub main wiring with two single core PVC insulated, unsheathed, FRLS stranded copper conductor cable 4 Sqmm with 4 Sqmm PVC insulated, unsheathed, FRLS stranded copper conductor cable as earth wire drawn through and including PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. Two run of 4 Sqmm cable i.e for one run for phase, one run for neutral with one run of 4 Sqmm cable for earth and one run of PVC Casing & caping shall be measured as one unit. |
| 55 | S&F in replacement sub main wiring concealed with two single core PVC insulated,unsheathed, FRLS stranded copper conductor cable 4 Sqmm with 4 Sqmm PVC insulated, unsheathed, FRLS stranded copper conductor cable as earth wire drawn through and including PVC Conduit 20 mm dia ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. Two run of 4 Sqmm cable i.e for one run for phase, one run for neutral with one run of 4 Sqmm cable for earth and one run of PVC Conduit shall be measured as one unit. |
| 56 | S&F in replacement sub main wiring with two single core PVC insulated,unsheathed, FRLS stranded copper conductor cable 1.5 Sqmm with 1.5 Sqmm PVC insulated, unsheathed, FRLS stranded copper conductor cable as earth wire drawn through and including PVC casing caping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. Two run of 1.5 Sqmm cable i.e for one run for phase, one run for neutral with one run of 1.5 Sqmm cable for earth and one run of PVC casing caping shall be measured as one unit |
| 57 | S&F in replacement sub main wiring three phase with 6 Sqmm single core,4 Run PVC insulated,unsheathed, FRLSH stranded copper conductor cable with 6 Sqmm,one Run PVC insulated, unsheathed, FRLSH stranded copper conductor cable as earth wire drawn through and including Concealed in wall with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. four run of 6 sq.mm cable i.e for three run for phase, one run for neutral with one run of 6 Sqmm cable for earth and one run of PVC Casing & caping shall be measured as one unit. |
| 58 | S&F in replacement sub main wiring with two single core PVC insulated,unsheathed, FRLSH stranded copper conductor cable 6 Sqmm with 6 Sqmm PVC insulated, unsheathed, FRLSH stranded copper conductor cable as earth wire drawn through and including PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge Note :1. Proper colour coding must be utilize for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. Two run of 6 sq.mm cable i.e for one run for phase, one run for neutral with one run of 6 Sqmm cable for earth and one run of PVC Casing & caping shall be measured as one unit. |
| 59 | M&L for earthing in replacement omplete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25 m depth and top edge of the earth plate not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts & washer etc. Earth wire connected upto main earth point / DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 using granded stone aggregate and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of TMT bar @ 100 mm CIC, both way, lifting arrangement complete including all necessary earth work etc complete all as specified and directed by Engineer-in-Charge |
| 60 | Taking out/ down and opening of existing ceiling fans 1200 mm sweep, from any position, of any make etc & refixing at the desired location after reassembling and after servicing/overhauling by thouroghly cleaning the shaft,rotor,stator and applying lubricant/ grease to bearings and one coat of super enamelled varnish over winding to improve the insulation resistance including repair /replacement of spare parts/ material /items , making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length including using material/parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/ lubricant etc to make it functional complete all as specified and as directed. |
| 61 | M&L for preperation of ceiling fans 1200 mm sweep, of any make by cleaning of metal surfaces including painting with spray painting on required gloss with white synthetic enamel paint on complete body of fans and writing MES No with black synthetic enamel paint etc complete all as specified and directed by Engineer-in-Charge |
| 62 | Supply & fixing in replacement capacitor 2.5/3 mfd, 250 volts , AC etc complete all as specified and directed by Engineer-in-Charge |
| 63 | S&F in replacement PVC insulated cable 40/0.0076, 3 core copper conductor cable for connection fron geyser to top plug etc complete all as specified and directed by Engineer-in-Charge. |
| 64 | Supply & fixing in replacement Ball bearing No 6201&6202 etc complete all as specified and directed by Engineer-in-Charge. |
| 65 | S&F in replacement of down rod 0.60 Mtr long made out of 15 mm bore medium grade GI pipe with & including clamp, nuts, bolts, split pins, washers, threading etc and making connections to make it functional etc complete all as specified and directed by Engineer-in-Charge. |
| 66 | S&F in replacement Modular white cover plate with frame 3 Module complete all as specified and directed. |
| 67 | S&F in replacement Modular white cover plate with frame 6 Module complete all as specified and directed. |
| 68 | S&F in replacement Modular white cover plate with frame 8/12 Module complete all as specified and directed. |
| 69 | S&F in replacement Modular metal flush box 6 Module complete all as specified and directed. |
| 70 | S & F for plastic body exhaust fan, AC single phase, 240 V of size 150 mm sweep including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan complete all as specified and as directed. |
| 71 | S & F for plastic body exhaust fan, AC single phase, 240 V of size 200 mm sweep with louvers including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan complete all as specified and as directed. |
| 72 | S & F for plastic body exhaust fan, AC single phase, 240 V of size 300 mm sweep with louvers including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan complete all as specified and as directed. |
| 73 | Supply & fix in replacement energy saving and environmental friendly long life LED street light 35 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP65 protection and impact resistance of IK07 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with & including twin core twisted flexible copper conductor cable of suitable size of 230V, 50 HZ etc complete all as specified and as directed by Engineer-in-Charge Please Enable Macros to View BoQ information |