| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminum point wiring (light/fan/bell/socket, power point etc) complete, including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors etc complete all as specified and directed Engineer-in-Charge. |
| 2 | M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn in and incl PVC Casing and capping ISI Marked with its accessories PVC boxes ( including white plates with frame upto 18 module) for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed. Note :1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2.Wiring shall be done as per complaints recd from user only on required basis it is not necessary to do whole wiring of any whole bldg3. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, ceiling lights, bulkhead lights, bldg security light etc |
| 3 | One light point /fan/bell point controlled by switch 5 Amp single pole one way |
| 4 | One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch |
| 5 | One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board |
| 6 | One light point controlled by switch 5 Amp single pole two way |
| 7 | .-ditto- all as per ser Item No 2 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase, Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board |
| 8 | M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn in and incl PVC Casing and capping ISI Marked with its accessories with provn of PVC boxes and fixed with brass screws cup washer for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed. Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, bulkhead lights, bldg security light etc.3.Wiring shall be done as per complaints recd from user only on required basis it is not necessary to do whole wiring of any whole bldg. |
| 9 | One light point/fan point/bell point controlled by switch 5 Amp single pole one way |
| 10 | One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch |
| 11 | One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board |
| 12 | .-ditto- all as per ser Item No 8 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase, Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board |
| 13 | S&F bell ding dong elelctric 230V AC single pole etc complete all as specified and directed by Engineer-in-Charge |
| 14 | S&F Modular Switch, 6 Amp, one way, one Module as per existing. etc complete all as specified and directed by Engineer-in-Charge |
| 15 | S&F Modular Switch, 6 Amp, two way, one Module. etc complete all as specified and directed by Engineer-in-Charge |
| 16 | S&F Modular Switch, 16 Amp, one way, one Module as per existing. etc complete all as specified and directed by Engineer-in-Charge |
| 17 | S&F Modular Socket Outlet 6 Amp, 3 pin, combined two module etc as per existing complete all as specified and directed by Engineer-in-Charge. |
| 18 | S&F Modular Socket Outlet 6 Amp / 16 Amp - 2/3 pin combined two module as per existing etc complete all as specified and directed by Engineer-in-Charge |
| 19 | S&F Modular Bell push, 6 Amp, one module etc complete all as specified and directed by Engineer-in-Charge |
| 20 | S&F Modular Fan Regulator Fan step regulator, capicitor type 120 Watt - two module etc complete all as specified and directed by Engineer-in-Charge |
| 21 | S&F switch piano flush type single pole, one way 5/6 Amp etc complete all as specified and directed by Engineer-in-Charge |
| 22 | S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required etc complete all as specified and directed by Engineer-in-Charge. |
| 23 | S&F Socket outlet 3 Pin, 6 A etc complete all as specified and directed by Engineer-in-Charge |
| 24 | S&Flamp holder (Angular/Straight ), insulated body, with back plate for batten fitting etc complete all as specified and directed by Engineer-in-Charge |
| 25 | S&F Switch socket combination as per existing, 6 Amp flush type 230V AC etc complete all as specified and directed by Engineer-in-Charge |
| 26 | S&F Switch socket combination 5 Amp / 16Amp, five in one, as per existing 230V AC etc complete all as specified and directed by Engineer-in-Charge |
| 27 | S&F in replacement ceiling rose 3 terminal / PVC / polycarbonate, isolated body etc complete all as specified and directed by Engineer-in-Charge . |
| 28 | Taking out old PVC/Wooden/metal switch board, wire connection from the wall and fix new PVC Cutting sheet board box including connecting wire suitable for fixing switch/Socket/fan regulater of following sizes. (Note. Damaged Switch / Socket / regulator will be measured and paid Sepereately) |
| 29 | 100 x100x 50 mm |
| 30 | 100 x175x 50 mm |
| 31 | 200 x150x 50 mm |
| 32 | 250 x200x 50 mm |
| 33 | 350 x300x 50 mm |
| 34 | S&F in replacement double door Sheet metal enclosures factory made DBs 4 way TPN, 415 volts, protection class IP-42, suitable for fixing of MCBs, etc, confirming as per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar, With Neutral bar, Earthbar and Cable ties for Cable management, Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. |
| 35 | S & F in replacement double door Sheet metal enclosures factory made DBs SPN, 8 way, 240 volts, protection class IP-42,Concealed in wall suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar, With Neutral bar, Earthbar and Cable ties for Cable management, Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. |
| 36 | S&F in replacement double door Sheet metal enclosures factory made DBs 4 way SPN, 240 volts, Concealed in wall protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar, With Neutral bar, Earthbar and Cable ties for Cable management, Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. |
| 37 | S&F in replacement MCB , SP, AC, 240 Volts of 06 to 40 Amp capacity 10KA, 'B' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge |
| 38 | S&F in replacement MCBs, TPN, AC, 415 volts of 63 Amps capacity 10 KA, 'B' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge . |
| 39 | S&F in replacement MCBs, SPN, AC, 240 volts of 40 Amps capacity 10 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge |
| 40 | S&F in replacement MCBs, SPN, AC, 240 volts of 63 Amps capacity 10 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge |
| 41 | S&F in replacement square profile LED lighting fixture , environmental friendly, energy efficient ready to use pack LED Tube light fitiing 20 Watt with LED light source 6500 K,input voltage 220V-270V with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed by Engineer-in-Charge |
| 42 | S&F in replacement square profile LED lighting fixture with, environmental friendly, energy efficient ready to use pack LED Tube light fitiing 10 Watt with LED light source 6500 K,input voltage 240 V-270V with uniform light output, with all accessories including its connection with 2 core seathed cable of size 0.5 Sqmm with etc complete all as specified and directed by Engineer-in-Charge |
| 43 | S&F in replacement environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head Back-lit 10 W LED ,IP65 ,IK 08 rated product luminaire comprising of high brightness LEDs complete with all accessories prewired and including connecting up with & including twin core twisted flexible copper conductor cable of suitable size etc complete all as specified and directed by Engineer-in-Charge |
| 44 | Supply & fix in replacemnt industrial type switch socket for Geysers with 20 Amp MCB etc complete all as specified and directed by Engineer-in-Charge |
| 45 | S&F sub main wiring with two single core PVC insulated,unsheathed, FRLS stranded copper conductor cable 4 Sqmm with 4 Sqmm PVC insulated, unsheathed, FRLS stranded copper conductor cable as earth wire drawn through and including PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. Two run of 4 Sqmm cable i.e for one run for phase, one run for neutral with one run of 4 Sqmm cable for earth and one run of PVC Casing & caping shall be measured as one unit. |
| 46 | S&F sub main wiring with two single core PVC insulated, unsheathed, FRLS stranded copper conductor cable 1.5 Sqmm with 1.5 Sqmm PVC insulated, unsheathed, FRLS stranded copper conductor cable as earth wire drawn through and including PVC casing caping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. Two run of 1.5 Sqmm cable i.e for one run for phase, one run for neutral with one run of 1.5 Sqmm cable for earth and one run of PVC casing caping shall be measured as one unit |
| 47 | S&F sub main wiring with two single core PVC insulated, unsheathed, FRLSH stranded copper conductor cable 6 Sqmm with 6 Sqmm PVC insulated, unsheathed, FRLSH stranded copper conductor cable as earth wire drawn through and including PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge Note :1. Proper colour coding must be utilize for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. Two run of 6 sq.mm cable i.e for one run for phase, one run for neutral with one run of 6 Sqmm cable for earth and one run of PVC Casing & caping shall be measured as one unit |
| 48 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25 m depth and top edge of the earth plate not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts & washer etc. Earth wire connected upto main earth point / DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 using granded stone aggregate and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of TMT bar @ 100 mm CIC, both way, lifting arrangement complete including all necessary earth work etc complete all as specified and directed by Engineer-in-Charge |
| 49 | S&F in replacement Modular white cover plate with frame 3 Module complete all as specified and directed |
| 50 | S&F in replacement Modular white cover plate with frame 6 Module complete all as specified and directed |
| 51 | S&F in replacement Modular white cover plate with frame 8 Module complete all as specified and directed |
| 52 | S&F in replacement Modular white cover plate with frame 12 Module complete all as specified and directed |
| 53 | S&F in replacement Modular metal flush box 6 Module complete all as specified and directed |
| 54 | CEILING FANSTaking out/down and opening of existing ceiling fans upto 1400 mm sweep,from any position, of any make etc & refixing at the desired location in the entire Cantt area including KK Range area after reassembling and after servicing/overhauling by thouroghly cleaning the shaft, rotor, stator and applying lubricant/ grease to bearings and including repair / replacement of spare parts/ material/items, making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length including using material/parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional complete all as specified and as directed.Note:- (i) The connected items required like capacitor,Bearings,Bush, Canopy, down rods etc will be measured and paid sperately under respective items. (ii) The rate for connected items required like Grease,nut bolt, washer insulation tape,1.5 sqmm wire are deemed to be included in the work. (iii) The each job will be measured on the basis of complaints receieved from users.Contractor will arrange ladder upto ceiling on own cost for repair/replacement of ceiling fan/wall fan |
| 55 | Opening of ceiling fans upto 1400 mm sweep, of any make and old type pattern ceiling fan etc in the store yard of AGE E/M , removing burnt out defective unserviceable winding & rewinding in E/M Store with appropriate size of super enamelled copper wire including applying super enamelled varnishing over winding , drying etc , reassembling and fixing after repair /replacement of spare parts/ material/items at the desired location including making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length including using material/parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, clamps, washers etc including painting and cleaning the metal surface, greasing/lubricant etc to make it functional etc complete all as specified and directedby Engineer-in-ChargeNote:- (i) The connected items required like capacitor,Bearings,Bush, Canopy,down rods etc will be measured and paid sperately under respective items. (II) Ceiling fan winding,Repair/Replacement will be in the AGE E/M Store yard. (iii) Bush type old vintage,Fan winding is included in above quatated rate. |
| 56 | S&Fin replacement Ball bearing No 6201 etc complete all as specified and directedby Engineer-in-Charge |
| 57 | S&F in replacement Ball bearing No 6202 etc complete all as specified and directedby Engineer-in-Charge |
| 58 | S&F in replacement capacitor 2.5 mfd, 250 volts, AC etc complete all as specified and directed by Engineer-in-Charge. |
| 59 | Supply and fix in replacement of rubber reel, bolt, nut including pin etc complete all as specified and directed by Engineer-in-Charge |
| 60 | Supply and Fix in replacement of electronic fan regulator electronic step up type, SP 230 volt suitable for 48/56 inches fans incl making necessary connections, to make it functional etc complete all as specified and directed by Engineer-in-Charge. |
| 61 | S & F fan Regulator switch type- Dimmer on the existing phenolic laminated etc. as reqd single pole 240 volts grade 100 watts heavy duty ISI marked. etc complete all as specified and directed by Engineer-in-Charge . |
| 62 | S&F in replacement of conopy (top and bottom) of ceiling fan , of any sweep, any make etc complete all as specified and directed by Engineer-in-Charge. |
| 63 | S&F in replacement of down rod 0.45 Mtr long made out of 15 mm bore medium grade GI pipe with & including clamp, nuts, bolts, split pins, washers, threading etc and making connections to make it functional etc complete all as specified and directed by Engineer-in-Charge |
| 64 | S&F in replacement of down rod 0.60 Mtr long made out of 15 mm bore medium grade GI pipe with & including clamp, nuts, bolts, split pins , washers , threading etc and making connections to make it functional etc complete all as specified and directed by Engineer-in-Charge |
| 65 | S&F in replacement of down rod 1.5 Mtr long made out of 15 mm bore medium grade GI pipe with & including clamp, nuts , bolts, split pins, washers, threading etc and making connections to make it functional etc complete all as specified and directed by Engineer-in-Charge |
| 66 | S&F in replacement of down rod 3.00 Mtr long made out of 15 mm bore medium grade GI pipe with & including clamp, nuts, bolts, split pins, washers, threading etc and making connections to make it functional etc complete all as specified and directed by Engineer-in-Charge |
| 67 | S&F in replacement of set of blades (set of three) made of aluminium suitable for 1200 mm sweep ceiling fans, of any tint, including provision of brass screws for fixing etc complete all as specified and directed by Engineer-in-Charge |
| 68 | M&L for preperation of ceiling fans upto 1400 mm sweep, of any make by cleaning of metal surfaces including painting with spray painting to required gloss with white synthetic enamel paint to complete body of fans and writing MES No with black paint etc complete all as specified and directed by Engineer-in-Charge. |
| 69 | EXHAUST FANSTaking down/out and Opening of existing exhaust fans of 300/450 mm sweep, of any make etc., refixing at the desired location in the entire Cantt area including KK Range area after reassembling and after servicing/overhauling by thouroghly cleaning the shaft, rotor, stator and applying lubricant/grease to bearings including repair / replacement of spare parts/ material/items, making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length including using material/parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, clamps, washers etc after cleaning the metal surface, greasing/ lubricant etc to make it functional etc complete all as specified and directed by Engineer-in-Charge Note:- (i) The connected items required like capacitor,Bearings,Bush, etc will be measured and paid sperately under respective items (ii) The rate for connected items required like Grease,nut bolt, washer insulation tape,1.5 sqmm wire are deemed to be included in the work.(iii) The each job will be measured on the basis of complaints receieved from users. |
| 70 | Taking out and Opening of existing exhaust fans 300 mm size, of any make etc from the store yard of AGE E/M, removing burnt out defective unserviceable winding & rewinding with appropriate size of super enamelled copper wire including varnishing, drying etc, reassembling and fixing at the desired location after replacing items/ material including making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length including using material/parts of minor nature such as screws, nuts, bolts, washers etc including cleaning the metal surface, lubricant/ greasing etc to make it functional etc complete all as specified and directed by Engineer-in-Charge Note:- (i) The connected items required like capacitor, Bearings, Bush, Canopy, etc will be measured and paid sperately under respective items |
| 71 | .-ditto- all as per ser item No.70 (here-in-before) but of 450 mm size |
| 72 | S&F in replacement capacitor 3.5/4 mfd, 250 volts , AC etc complete all as specified and directed by Engineer-in-Charge |
| 73 | M&L for preperation of exhaust fans 300 mm sweep, of any make by cleaning of metal surfaces including painting with spray painting to required gloss with white synthetic enamel paint to complete body of fans and writing MES No with black paint etc complete all as specified and directed by Engineer-in-Charge. |
| 74 | M&L for preperation of exhaust fans 450 mm sweep, of any make by cleaning of metal surfaces including painting with spray painting to required gloss with white synthetic enamel paint to complete body of fans and writing MES No with black paint etc complete all as specified and directed by Engineer-in-Charge. |
| 75 | WALL FANS/TABLE FANSTaking down/ out carefully including opening of existing Padestal/wall mounted fans/ air circulator heavy duty size/ sweep, of any make etc from any location, refixing at the desired location after reassembling and after servicing/ overhauling by thouroghly cleaning the shaft, rotor, stator and applying lubricant/grease to bearings and one coat of super enamelled varnish over winding to improve the insulation resistance including repair /replacement of spare parts/ material/ items, making connection by using material/ parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, clamps, washers etc after cleaning the metal surface, greasing/ lubricant etc to make it functional etc complete all as specified and directed by Engineer-in-Charge Note:- (i) The connected items required like capacitor, Bearings, Bush etc will be measured and paid sperately under respective items (ii) The rate for connected items required like Grease,nut bolt, washer insulation tape,1.5 sqmm are wire are deemed to be included in the work.(iii) The each job will be measured on the basis of complaints receieved from users. |
| 76 | Opening of existing Padestal/wall mounted fans , upto 400/ 450 mm size/ sweep, of any make etc from the store yard of AGE E/M, removing burnt out defective unserviceable winding & rewinding IN E/M Store yard with appropriate size of super enamelled copper wire including varnishing, drying, cleaning of bearing,shaft, stator,rotor etc, reassembling and fixing at the desired location including making connection to make it functional by using material/ parts of minor nature such as screws, nuts, bolts, washers etc including cleaning , greasing/ lubricant etc complete all as specified and as directed.Note:- (i) The connected items required like capacitor, Bearings, Bush, Canopy, down rods etc will be measured and paid sperately under respective items |
| 77 | S&F in replacement Anchor fastner in wall for geyser etc complete all as specified and directed by Engineer-in-Charge |
| 78 | GEYSERSTaking out/down carefully and opening of existing water Geysers of 25 Ltrs capacity,from any position,anywhere in Cantt including KK Ranges of any make etc & refixing after reassembling and after repair /replacement of spare parts/ material/items, at the desired location and making necessary water inlet, outlet & electric connections to make in functional by using material/parts of minor nature such as screws, insulation tape, nuts, bolts, washers etc complete all as specified and directed by Engineer-in-Charge Note :- Material/ items/spare parts required for repair/ replacement shall be mesured and paid separetely under respective items |
| 79 | GEYSERSTaking out/down carefully and opening of existing water Geysers of 25 Ltrs capacity,from any position,anywhere in Cantt including KK Ranges of any make etc painting with spray painting to required gloss with white synthetic enamel paint to complete body refixing after reassembling and after repair /replacement making necessary water inlet, outlet & electric connections to make in functional by using material/parts of minor nature such as screws, insulation tape, nuts, bolts, washers etc complete all as specified and directed by Engineer-in-Charge Note :- Material/ items/spare parts required for repair/ replacement shall be mesured and paid separetely under respective items |
| 80 | S&F in replacement of base assembly suitable for 25 ltrs capacity geyser with inlet and outlet pipe made out of copper base plate with gasket , proper size of nuts, bolts & washers etc complete all as specified and directed by Engineer-in-Charge |
| 81 | Supply only inner tank sheet cover made of MS sheet suitable for 25 ltrs geyser capacity of any Make as installed at site including outer insulation,puf etc complete all as specified and directed by Engineer-in-Charge. |
| 82 | S&F in replacement element 1.5 KW, rubber gasket type with & including rubber gasket complete suitable for 25 Ltrs Geysers of any Make as installed at site etc complete all as specified and directed by Engineer-in-Charge |
| 83 | S&F in replacement element 2 KW, rubber gasket type with & including rubber gasket complete suitable for 25 Ltrs Geysers of any Make as installed at site etc complete all as specified and directed by Engineer-in-Charge |
| 84 | S&F in replacement PVC insulated cable 40/0.0076, 3 core copper conductor cable for connection fron geyser to top plug etc complete all as specified and directed by Engineer-in-Charge |
| 85 | S&F in replacement safety valve(pressure release valve) suitable for 25/50 ltrs capacity vertical type geyser etc complete all as specified and directed by Engineer-in-Charge |
| 86 | S&F in replacement brass,non return valve 15 mm bore suitable for 25/50 ltrs capacity vertical type geyser of any make as installed at site etc complete all as specified and directed by Engineer-in-Charge |
| 87 | S&F in replacement indicator lamps(set of two -green & red) AC, 220 volts suitable for 25/50 ltrs capacity vertical type geyser etc complete all as specified and directed by Engineer-in-Charge |
| 88 | S&F in replacement thermostat switch, pointer type with adjustable knob, suitable for 25/50 ltrs capacity vertical type geyser & etc complete all as specified and directed by Engineer-in-Charge |
| 89 | Supply only PVC connection pipe complete with brass end terminal size 600 mm long. Make : kohinoor Gold/Havells or equivalent |
| 90 | Supply only PVC connection pipe complete with brass end terminal size 900 mm long etc complete all as specified and directed by Engineer-in-Charge. Make : kohinoor Gold/Havells or equivalent |
| 91 | S&F in replacement thermal cut out suitable for 25/50 ltrs capacity vertical type geyser etc complete all as specified and directed by Engineer-in-Charge. |
| 92 | S&F in replacement 15/16 Amp three pin, plug top, 230 Volts, suitable for 25/50 ltrs capacity geyser etc complete all as specified and directed by Engineer-in-Charge |
| 93 | M&L for checking the solar water heater for No water in tap, Water not heated at all,although cold water flow is normal, Water not heated enough or sufficient quantity of hot water is not available, insufficient quantity of boiling hot water is received, leakge of water from collectors etc and cleaning of Tubes and collectors etc and testing of Solar water heater for desired temperature hot water etc complete all as specified and directed by Engineer-in-Charge. |
| 94 | S& Fix in replacement solar water heater glass tubes suitable upto capacity 300 ltrs complete all as specified and directed |
| 95 | S& Fix in replacement solar water rubber hose pipe suitable for 100 ltrs capacity complete all as specified and directed |
| 96 | S & F for plastic body exhaust fan, AC single phase, 240 V of size 150 mm sweep including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan and deposit to E/M Store yard complete all as specified and as directed. |
| 97 | S & F for plastic body exhaust fan, AC single phase, 240 V of size 200 mm sweep with louvers including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan and deposit to E/M Store yard complete all as specified and as directed. |
| 98 | S & F for plastic body exhaust fan, AC single phase, 240 V of size 250 mm sweep with louvers including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan and deposit to E/M Store yard complete all as specified and as directed. |
| 99 | S & F for wall mounted high speed fan, AC single phase, 240 V of size 300 mm sweep ,air delivery more than 90 CFM ,number of speed setting 3 including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan complete all as specified and as directed. |
| 100 | Taking down existing Exhaust fan metal body from the wall/window and deposit to E/M Store yard S & F New Exhaust fan metal body 300 mm sweep with high speed 2100 RPM including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan complete all as specified and as directed |
| 101 | Taking down existing Exhaust fan metal body from the wall/window and deposit to E/M Store yard S & F New Exhaust fan metal body 450 mm high speed 1400 RPM including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan complete all as specified and as directed |
| 102 | Supply & fix in replacement energy saving and environmental friendly long life LED street light 35 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP65 protection and impact resistance of IK07 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with & including twin core twisted flexible copper conductor cable of suitable size of 230V , 50 HZ etc complete all as specified and as directed by Engineer-in-Charge |
| 103 | Supply & fix in replacement 36 Watt LED Panel 2X2 environmental friendly, new generation,aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source,6500 K suitable for armstrong/Grid ceiling, complete with separate electronic driver ceiling light 36 Watt with and including connecting up with & including twin core, twisted, flexible copper conductor cable of suitable size 230 Volt, 50 HZ etc complete all as specified and directed by Engineer-in-Charge . |
| 104 | Supply & fix in replacement Square/Round shape warm white12 Watt LED downlighter with high efficacy LEDS,Operating voltage 160V-360V with surge protection of 2 KV ideally suited for low ceiling areas to give glare free light, complete with and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size 230V , 50 HZ etc complete all as specified and directed by Engineer-in-Charge . |
| 105 | Supply & fix 18 Watt LED Surface LED Panel 1X1 environmental friendly, new generation,aesthetically designed, flat panel for surface mounting which provides soft-light and glare free symmetrical illumination, complete with separate electronic driver ceiling light 18 W including connecting up with & including twin core twisted flexible copper conductor cable of suitable size of 230 Volt, 50 HZ etc complete all as specified and directed by Engineer-in-Charge |
| 106 | Notes for Item Ceiling fan, Exhaust fan, geyser(i) Contractor has to take the complaint at MES power house (E/M) from Concern JE E/M Daily Basis (Except Sunday & holiday).(ii) Contrcator has to attend the complaint within 24 Hrs after received from sub divsion(iii) Contrctor has to provide the Mobile no so that massges can be send on the same mobile No.(iv) For non collection of complaits from JE E/M Rs.500/- per day will be charged. (v) For Non attendence of complaints in 24 Hrs Rs.200/- per day per complaint will be charged(vi) Contractor has to return the complaint duly signed from the user with time & date. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail