| 1 | Supply & fix in replacement energy saving and environmental friendly long life LED street light 35 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP65 protection and impact resistance of IK07 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with & including twin core twisted flexible copper conductor cable of suitable size of 230V , 50 HZ etc complete all as specified and as directed by Engineer-in-Charge |
| 2 | Supply & fix in replacement 36 Watt LED Panel 2X2 environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source, 6500 K suitable for armstrong/Grid ceiling, complete with separate electronic driver ceiling light 36 Watt with and including connecting up with & including twin core, twisted, flexible copper conductor cable of suitable size 230 Volt, 50 HZ etc complete all as specified and directed by Engineer-in-Charge. |
| 3 | Supply & fix in replacement 36 Watt LED Panel 2X2 surface mounting environmental friendly, new generation,aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source,6500 K suitable for armstrong/Grid ceiling, complete with separate electronic driver ceiling light 36 Watt with and including connecting up with & including twin core, twisted, flexible copper conductor cable of suitable size 230 Volt, 50 HZ etc complete all as specified and directed by Engineer-in-Charge . |
| 4 | Supply & fix in replacement 15 Watt LED Panel 1X1 environmental friendly, new generation,aesthetically designed, flat panel for surface mounting which provides soft-light and glare free symmetrical illumination, complete with separate electronic driver ceiling light 15W including connecting up with & including twin core twisted flexible copper conductor cable of suitable size of 230 Volt, 50 HZ etc complete all as specified and directed by Engineer-in-Charge |
| 5 | Supply & fix in replacement warm white 36 Watt LED Panel 2X2 environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source, 4500 K suitable for armstrong/Grid ceiling, complete with separate electronic driver ceiling light 36 Watt with and including connecting up with & including twin core, twisted, flexible copper conductor cable of suitable size 230 Volt, 50 HZ etc complete all as specified and directed by Engineer-in-Charge. |
| 6 | Supply & fix in replacement Round shape, 12 Watt LED downlighter with high efficacy LEDS,Operating voltage 160V-360V with surge protection of 2 KV ideally suited for low ceiling areas to give glare free light, complete with and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size 230V , 50 HZ etc complete all as specified and directed by Engineer-in-Charge. |
| 7 | Supply & fix round/Square shape 6 Watt LED downlighter with high efficiencey LEDS Operating voltage 160V-360V with surge protection of 2 KV , ideally suited for low ceiling areas to give glare free light , complete with including connecting up with and including twin core twisted flexible copper conductor cable of suitable size of 230V, 50 HZ etc complete all as specified and directed by Engineer-in-Charge. |
| 8 | Supply & fix in replacement Square shape, 12 Watt LED downlighter with high efficacy LEDS,Operating voltage 160V-360V with surge protection of 2 KV ideally suited for low ceiling areas to give glare free light, complete with and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size 230V , 50 HZ etc complete all as specified and directed by Engineer-in-Charge. |
| 9 | S&F in replacement square profile LED lighting fixture with extruded environmental friendly, energy efficient ready to use pack LED Tube light fitiing 10 Watt with LED light source 6500 K,input voltage 140V-270V with uniform light output, with all accessories including its connection with 2 core seathed cable of size 0.5 Sqmm with etc complete all as specified and directed by Engineer-in-Charge. |
| 10 | S&F in replacement square profile LED lighting fixture, environmental friendly, energy efficient ready to use pack Aluminium housing LED Tube light fitiing 40 Watt with LED light source 6500 K,input voltage 240V-270V with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed by Engineer-in-Charge . |
| 11 | S&F in replacement square profile LED lighting fixture, environmental friendly, energy efficient ready to use pack Aluminium housing LED Tube light fitiing 20 Watt with LED light source 6500 K,input voltage 240V-270V with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed by Engineer-in-Charge . |
| 12 | Supply and fix in replacement Warm white Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitiing 20 Watt with LED light source with uniform light output, Complete all as specified and directed |
| 13 | Supply & fix in replacement LED Bulb 12W Emergency Bulb | Rechargeable Emergency Bulb for Power Cuts | Backup : 4hrs, Cool Day Light,Pack of 1, b22d, LED to fix on batten holder etc complete all as specified and directed by Engineer-in-Charge |
| 14 | Supply & fix in replacement Rechargeable LED Bulb 10 Watt (Warm white) and lumen output 950 suitable for \\"B-22 type to fix on batten holder and wall light etc complete all as specified and directed by Engineer-in-Charge |
| 15 | Taking down carefully copper/aluminum point wiring (light/fan/bell/socket, power point etc) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors etc complete all as specified and directed Engineer-in-Charge. |
| 16 | M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn in and incl PVC Casing and capping ISI Marked with its accessories with provn of PVC boxes and fixed with brass screws cup washer for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed. Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, bulkhead lights, bldg security light etc |
| 17 | One light point controlled by switch 5 Amp single pole one way |
| 18 | One Fan point controlled by switch 5 Amp single pole one way |
| 19 | One bell point controlled by switch 5 Amp single pole one way |
| 20 | One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch |
| 21 | One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board |
| 22 | One light point controlled by switch 5 Amp single pole two way |
| 23 | .-ditto- all as per Item No 16 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase, Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board |
| 24 | M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn in and incl PVC Casing and capping ISI Marked with its accessories PVC boxes (upto 18 module suitble for Mylinc series of Legrand including white plates with frame upto 18 module of make suitable for Mylinc Series ) for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed. Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2.Wiring shall be done as per complaints recd from user only on required basis it is not necessary to do whole wiring of any whole bldg3. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, ceiling lights, bulkhead lights, bldg security light etc |
| 25 | One light point /fan point/bell point controlled by one switch with cables 1.5 sq. mm size |
| 26 | One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch |
| 27 | One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board |
| 28 | One light point controlled by switch 5 Amp single pole two way |
| 29 | .-ditto- all as per ser Item No 24 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase, Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board |
| 30 | S&F in replacement bell ding dong elelctric 230V AC single pole etc complete all as specified and directed by Engineer-in-Charge |
| 31 | S&F in replacement Modular Switch, 6 Amp, one way, one Module as per existing of any type. etc complete all as specified and directed by Engineer-in-Charge |
| 32 | S&F in replacement Modular Switch, 6 Amp, two way, one Module. etc complete all as specified and directed by Engineer-in-Charge |
| 33 | S&F in replacement Modular Switch, 16 Amp, one way, one Module as per existing. etc complete all as specified and directed by Engineer-in-Charge . |
| 34 | S&F in replacement Modular Socket Outlet 6 Amp, 3 pin, combined two module etc as per existing complete all as specified and directed by Engineer-in-Charge. |
| 35 | S&F in replacement Modular Socket Outlet 6 Amp / 16 Amp - 2/3 pin combined two module as per existing etc complete all as specified and directed by Engineer-in-Charge. |
| 36 | S&F in replacement Modular Bell push, 6 Amp, one module etc complete all as specified and directed by Engineer-in-Charge |
| 37 | S&F in replacement Modular Fan Regulator Fan step regulator,suitable for 1200 mm fan two module etc complete all as specified and directed by Engineer-in-Charge . |
| 38 | S&F in replacement switch piano flush type single pole, one way 5/6 Amp etc complete all as specified and directed by Engineer-in-Charge |
| 39 | S&F in replacement stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required etc complete all as specified and directed by Engineer-in-Charge. |
| 40 | S&F in replacement Socket outlet 3 Pin ,6 A etc complete all as specified and directed by Engineer-in-Charge |
| 41 | S&F in replacement Switch socket combination with box as per existing, 6 Amp flush type 230V AC etc complete all as specified and directed by Engineer-in-Charge |
| 42 | S&F in replacement Switch socket combination 5 Amp / 16Amp, five in one, with box as per existing 230V AC etc complete all as specified and directed by Engineer-in-Charge |
| 43 | S&F in replacement lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting etc complete all as specified and directed by Engineer-in-Charge |
| 44 | S&F in replacement ceiling rose 3 terminal / PVC / polycarbonate, isolated body etc complete all as specified and directed by Engineer-in-Charge . |
| 45 | Taking out old PVC/ Wooden/ metal switch board, wire connection from the wall and fix new PVC Modular board box including connecting wire suitable for fixing switch/ Socket/ fan regulater of following sizes. (Note.Damaged Switch / Socket / regulator will be measured and paid Sepereately) |
| 46 | 100 x 100 x 50 mm |
| 47 | 100 x 175 x 50 mm |
| 48 | 200 x 150 x 50 mm |
| 49 | 250 x 200 x 50 mm |
| 50 | 350 x 300 x 50 mm |
| 51 | S & F in replacement double door Sheet metal enclosures factory made DBs 4 way TPN, 415 volts ,protection class IP-42, suitable for fixing of MCBs, etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. |
| 52 | S & F in replacement double door Sheet metal enclosures factory made DBs SPN, 8 way ,240 volts ,protection class IP-42,Concealed in wall suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. |
| 53 | S & F in replacement double door Sheet metal enclosures factory made DBs 4 way SPN, 240 volts ,Concealed in wall protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. |
| 54 | S&F in replacement MCB , SP, AC, 240 Volts of 06 to 40 Amp capacity 10KA, 'B' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge |
| 55 | S&F in replacement MCBs, TPN, AC, 415 volts of 63 Amps capacity 10 KA, 'B' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge . |
| 56 | S&F in replacement MCBs, SPN, AC, 240 volts of 40 Amps capacity 10 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge |
| 57 | S&F in replacement MCBs, SPN, AC, 240 volts of 63 Amps capacity 10 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge |
| 58 | Supply & fix in replacemnt industrial type switch socket for Geysers with 20 Amp MCB etc complete all as specified and directed by Engineer-in-Charge |
| 59 | S&F in replacement sub main wiring with two single core PVC insulated,unsheathed, FRLS stranded copper conductor cable 4 Sqmm with 4 Sqmm PVC insulated, unsheathed, FRLS stranded copper conductor cable as earth wire drawn through and including PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. Two run of 4 Sqmm cable i.e for one run for phase, one run for neutral with one run of 4 Sqmm cable for earth and one run of PVC Casing & caping shall be measured as one unit. |
| 60 | S&F sub main wiring with two single core PVC insulated,unsheathed, FRLS stranded copper conductor cable 2.5 Sqmm with 2.5 Sqmm PVC insulated, unsheathed, FRLS stranded copper conductor cable as earth wire drawn through and including PVC casing caping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. Two run of 2.5 Sqmm cable i.e for one run for phase, one run for neutral with one run of 2.5 Sqmm cable for earth and one run of PVC casing caping shall be measured as one unit |
| 61 | S&F in replacement sub main wiring three phase with 6 Sqmm single core, 4 Run PVC insulated,unsheathed, FRLSH stranded copper conductor cable with 6 Sqmm,one Run PVC insulated, unsheathed, FRLSH stranded copper conductor cable as earth wire drawn through and including PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge .Note :1. Proper colour coding must be utilize for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. Three run of 6 sq.mm cable i.e for three run for phase, one run for neutral with one run of 6 Sqmm cable for earth and one run of PVC Casing & caping shall be measured as one unit |
| 62 | M&L for earthing in replacement complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25 m depth and top edge of the earth plate not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts & washer etc. Earth wire connected upto main earth point / DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 using granded stone aggregate and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of TMT bar @ 100 mm CIC, both way, lifting arrangement complete including all necessary earth work etc complete all as specified and directed by Engineer-in-Charge. |
| 63 | S&F in replacement Modular white cover plate with frame 3 Module complete all as specified and directed |
| 64 | S&F in replacement Modular white cover plate with frame 6/8 Module complete all as specified and directed |
| 65 | S&F in replacement Modular white cover plate with frame 8/12 Module complete all as specified and directed |
| 66 | S&F in replacement Modular metal flush box 6 Module complete all as specified and directed |
| 67 | S & F for plastic body exhaust fan, AC single phase, 240 V of size 150 mm sweep including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan complete all as specified and as directed. |
| 68 | S & F for plastic body exhaust fan, AC single phase, 240 V of size 200 mm sweep with louvers including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan complete all as specified and as directed |
| 69 | S & F for plastic body exhaust fan, AC single phase, 240 V of size 250 mm sweep with louvers including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan complete all as specified and as directed |
| 70 | S & F for plastic body exhaust fan, AC single phase, 240 V of size 300 mm sweep with louvers including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan complete all as specified and as directed |
| 71 | S&F in replacement 100 Watt high bay light fittings Epoxy powder coated pressure die cast aluminium housing in grey finish with elegantly designed heat sink for efficient thermal management,strdiness & excellent corrosion resistent,m16 cable gland provided at cable entery ,the fixture epoxy coated,high efficiency long life LED lumen efficiency of >140 lm/W,power factor>.95 with view angle 120 degree for better uniformity,tempered protective toughned glass ,thermal shock and impact resistence IK 07 fixed to the housing,built in potted IP65 electronic LED driver with APFC,lower THD,phase to phase(440 V withstand ) Open circuit protection,over voltage protection, surge voltage protection,suspended by means of heavy duty nickel plated,eye volt provided with fixture complete all as directed by Engineer in Charge. |
| 72 | S&F in replacement 150 Watt high bay light fittings Epoxy powder coated pressure die cast aluminium housing in grey finish with elegantly designed heat sink for efficient thermal management, strdiness & excellent corrosion resistent,m16 cable gland provided at cable entery, the fixture epoxy coated, high efficiency long life LED lumen efficiency of >140 lm/W with view angle 120 degree for better uniformity, tempered protective toughned glass, thermal shock and impact resistence IK 07 fixed to the housing, built in potted IP65 electronic LED driver with APFC, lower THD, phase to phase (440 V withstand) Open circuit protection, over voltage protection, surge voltage protection, suspended by means of heavy duty nickel plated, eye volt provided with fixture complete all as directed by Engineer in Charge Please Enable Macros to View BoQ information |