| 1 | Total amount of Sch 'A' Sec-I (BUILDING AND SWT WORKS) Lump sum price worked out by the contractor for \\"BUILDING AND SWT WORKS\\" as listed in schedule 'A' Part-I |
| 2 | Total amount of Sch 'A' Sec- II (SITE DEVELOPEMENT & MISC. EARTH WORKS) Lump sum price worked out by the contractor for \\"SITE DEVELOPEMENT & MISC. EARTH WORKS\\" as listed in schedule 'A' Part-II |
| 3 | Total amount of Sch 'A' Sec- III (INTERNAL ELECTRIFICATION WORKS) Lump sum price worked out by the contractor for \\"INTERNAL ELECTRIFICATION WORK \\" as listed in schedule 'A' Part-III |
| 4 | Total amount of Sch 'A' Sec-IV (SEWAGE DISPOSAL WORKS) Lump sum price worked out by the contractor for \\"SEWAGE DISPOSAL WORKS\\" as listed in schedule 'A' Part-IV |
| 5 | Total amount of Sch 'A' Sec- V (PATH, CULVERTS AND HARDSTANDING WORKS) Lump sum price worked out by the contractor for \\"PATH, CULVERTS AND HARDSTANDING WORKS\\" as listed in schedule 'A' Part-V |
| 6 | Total amount of Sch 'A' Sec- VI (AREA DRAINAGE WORKS) Lump sum price worked out by the contractor for \\"AREA DRAINAGE WORKS\\" as listed in schedule 'A' Part-VI |
| 7 | Total amount of Sch 'A' Sec- VII (FENCING WORKS) Lump sum price worked out by the contractor for \\"FENCING WORK\\" as listed in schedule 'A' Part-VII |
| 8 | Total amount of Sch 'A' Sec- VIII (PROTECTIVE WORKS) Lump sum price worked out by the contractor for \\"PROTECTIVE WORKS\\" as listed in schedule 'A' Part-VIII |
| 9 | Total amount of Sch 'A' Sec-IX (EXTERNAL WATER SUPPLY WORKS) Lump sum price worked out by the contractor for \\"EXTERNAL WATER SUPPLY WORKS\\" as listed in schedule 'A' Part-IX |
| 10 | Total amount of Sch 'A' Sec - X (DEMOLITION WORKS) Lump sum price worked out by the contractor for \\"DEMOLITION WORKS\\" as listed in schedule 'A' Part-X. |
| 11 | Schedule 'A' Section-XII (Misc Items of Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col. 5 siginifies this fact only. |
| 12 | SITE DEVELOPEMENT & MISC. EARTH WORKSForming embankments including raising (or lowering) earth, spreading in layers n exc 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc 1.5 m high from base complete all as specified and directed. |
| 13 | INTERNAL ELECTRIFICATION WORKSConcealed point wiring using approved colour coding as per IS, with 1.5 Sqmm (nominal area), single core multistranded copper conductor of 1100 volts grade, ISI 694 marked, PVC insulated and unsheathed FRLS-H, drawn through and including heavy duty PVC conduit of appropriate dia (2mm wall thickness) and conduit accessories ISI marked, PVC junction boxes etc, concealed in walls/ceiling/floors including 1.5 Sqmm (nominal area), single core multistranded copper conductor of 1100 volts grade, ISI 694 marked, PVC insulated and unsheathed FRLS-H as earth continuity conductor to common earth & connecting to earth dolly for the following :- |
| 14 | One light/fan point (Ceiling/ Wall/ Exhaust) controlled by one number one way switch or one number one way switch and regulator |
| 15 | One 5/6 Amps socket outlet on independent board |
| 16 | One 5/6 Amps socket outlet on the same board with other switches |
| 17 | Concealed point wiring using approved colour coding as per IS, for 15 Amps socket outlet on independent board with 2.5 Sqmm (nominal area), single core multistranded copper conductor of 1100 volts grade, ISI 694 marked, PVC insulated and unsheathed FRLS-H, drawn through and including heavy duty PVC conduit of appropriate dia (2mm wall thickness) and conduit accessories ISI marked, PVC junction boxes etc, concealed in walls/ceiling/floors including 2.5 Sqmm (nominal area), single core multistranded copper conductor of 1100 volts grade, ISI 694 marked, PVC insulated and unsheathed FRLS-H as earth continuity conductor to common earth & connecting to earth dolly.Notes for item Nos. 13 to 14 : (a) Modular metal flush boxes, modular cover plates with frame and switches/sockets etc shall be measured and paid separately under respective items of Sch 'A'/BOQ here-in-after.(b) Cost of cutting/chases for concealing of conduit shall be deemed to be included in quoted lump sum of Sch 'A' Section-I. |
| 18 | MCB SP, 240 Volt , 50 Hz, 6 to 32 A, 10 KA , \\"B\\" curve, complete all as specified and directed. |
| 19 | BLDC Ceiling fan energy efficient, minimum service value (m3/minute/Watt)>= 6.0, including modular electronic step type fan regulator, 2 module 120 watts fixed on cover sheet, 230 V, 50 Hz, 1200 mm sweep conforming to IS 374-2019, with all standard accessories as per manufacturer's recommendations ,with provision of PVC insulated flexible cable FRLSH grade 3 core 0.5mm copper conductor 1100 volts grade from porcelain connector /ceiling rose to ceiling fan,complete all as specified and directed. |
| 20 | Energy saving LED light fitting , 1 x 20 watt, 230 volts, Decorative ultra slim linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack with electronic driver and with best quality diffuser high lumen output, 2.5 KV voltage surge protection, PF 0.98, THD < 10 % suitable for surface/ pendant mounting complete with all accessories including and connecting of with twin core of PVC insulated 0.75 Sqmm copper conductor cable complete all as specified and directed. |
| 21 | Energy generation energy saving and environmental friendly long life LED building security light 1 x 35 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having top opening separate driver compartment IP 65 protection and impact resistance of IK 07, with all accessories including suitable bracket with 32 mm bore light grade GI pipe bent to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed. |
| 22 | RCBO 'A' Type (SPN-2M) 32 Amp 30 mA (In accordance with IS 12640-2 & IEC 61009-1) 240 V/415 V 50 Hz, with 10 KA short circuit capacity, RCBO is designed for use in domestic , commercial and industrial distribution systems at the most downstream circuit for ensuring protection from leakage current, short circuit & over load to the user for a particular circuit. In normal use, it is safe tio use and free of threat to user as well as to environment complete all as specfied and directed . Make Havells Cat no DHCEACSN2030032 or equivalent in other specified makes. |
| 23 | Exhaust fan 300 mm sweep made of sturdy Engineering metal body, heavy duty, Single phase AC 230/240V, with energy efficient motor, pre lubricated double ball bearing, speed 900 rpm complete with louvers for wall mounting incl providing & grouting holding down bolts, nuts, washers and provision of flexible copper conductor cable 3 core from ceiling rose to exhaust fan incl complete all as specified and directed. Note: Cost of making hole of required size for fixing of the exhaust fan , shall be deemed to be included in quoted lump sum of Sch 'A' Section-I. |
| 24 | PROTECTIVE WORKS PVC(SWR) pipes single socketed 110mm bore, in single length (without joints), laid in weep holes in stone masonry complete all as specified and directed. |
| 25 | EXTERNAL WATER SUPPLY WORKSCutting of existing rising main MS heavy duty pipe of size 150mm dia in position for tapping & insertion of Tee and making branch connection of size 150mm dia for 100000 GLN SWT from existing MS rising main of size 150mm dia including jointing all necessary fittings Tee (150x150x150), flange heavy duty with nut bolt washer & rubber/fiber gasket of 3mm thickness complete all as specified & directed Note:- (i) Excavation and earth work is included in this item. (ii)Titan joint /and lead joint required on site will be included in this item and nothing will be paid extra on these account. |
| 26 | MS ERW steel flanged pipe of size 150mm dia conforming to IS-3589 (1981,) wall thickness of pipe 5.0mm, laid in trench in hard/dense soil under road, culvert etc including all necessary fittings such as Tee, Bend, Nipple, heavy duty flanged etc including nut bolt washer, rubber/fiber gasket of 3mm thickness complete all as specified and directed. |
| 27 | All as per Srl item No 23.00 above but 100 mm dia. |
| 28 | MS ERW steel flanged pipe of size 80mm dia conforming to IS-3589 (1981,) wall thickness of pipe 4.4 mm, laid in trench in hard/dense soil under road, culvert etc including all necessary fittings such as Tee, Bend, Nipple, heavy duty flanged etc including nut bolt washer, rubber/fiber gasket of 3mm thickness complete all as specified and directed. Note for Srl item No 23, 24 & 25 :- (a) Welding works i.e flanged to be welded in plain end of pipe etc is inclusive in the quoted unit rate and nothing will be paid extra on this account. (b) Excavation and earth work shall be measured and paid seperately. |
| 29 | Cast iron Air Release Valve with 2 air outlet 50mm dia bore, ISI marked & fixing up in GI water supply mains 80mm bore, including joints and jointing materials such as nuts, bolts, washers and rubber/fibe gaskets complete all as specified & directed. |
| 30 | Cast iron Air Release Valve with 2 air outlet 50mm dia bore, ISI marked & fixing up in GI water supply mains 100mm bore, including joints and jointing materials such as nuts, bolts, washers and rubber/fibe gaskets complete all as specified & directed. |
| 31 | Cast iron foot valve 100 mm bore, ISI marked inclduing joints and jointing meterial complete all as specified & directed. |
| 32 | Single core FRLS multi-starnded PVC unsheathed 1100 Volt grade single core copper conductor cable of size 10 sqmm drawn through PVC flexible conduit from motor starter panel to motor complete all specified and directed. |
| 33 | Supply/Laying / fixing, jointing, testing and commissioning, LT under ground cable 1100 volts grade XLPE insulated & PVC sheathed cable heavy duty armoured, with multistranded aluminium conductor laid in trenches/ ducts/ pipes/fixed on walls/poles complete all as specified and directed of following sizes:-.Note:- (a) Excavation & earth work, GI pipe for laying of cable, sand cushioning & cable protection cover shall be measured and paid for seprately under respective items of the schedule.(b) Cable shall be tested in the presence of Engr-in Charge after laying in the trench before returning filling in the trench. |
| 34 | 4 Core 50 Sqmm |
| 35 | Dry sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified and directed.Note :- Thickness after punning shall be considered for payment. |
| 36 | Unreinforced precast concrete cable cover, ISI Marked IS-5820 (Latest Edition), class LV, Type 1, flat, size 250mm x 150mm x 40mm for protection of LT cable complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 37 | Unreinforced precast concrete cable cover, ISI Marked IS-5820 (Latest Edition), class LV, Type 1, flat, size 250mm x 150mm x 40mm for protection of LT cable complete all as specified and as directed. Please Enable Macros to View BoQ information |