| 1 | S&F in repair framed work as in doors or gates of angle made out of FE 410-W Gde E-250 quality -A or other section with gusset plates, rails, fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 2 | M & L for cross arms, bracing, supports, clamps and back plated fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of 2 coats of aluminium paint over a coat of red oxide primer after dismantling old unserviceable cross arms complete all as specified and as directed. |
| 3 | S&F in repair 150 watt LED flood light fittings having long life of high power LED with SMD LED exclusive innovative dia cast aluminium IP-66 built in IP-67 electronic driver with APFC, lower THD, open circuit protection, over voltage protection, surge protection up to 10KV with built in SPD & other safety as per IS-15885 part -2 ,Sec 13, IEC 60598-1 of operating voltage 140-270V avg life 50,000 hours complete manufacture prove all test certificate as per protection for minimum 2 years from manufacturing companies complete all as specified and directed. |
| 4 | S&F in repair LED Street Light fixture of 70W with IP-66 protected die-cast aluminium housing and heat resistive toughened glass. LED shall be having LM-79 and LM-80 complied as per L-70 standard. Maximum power consumption shall not exceed 70/72W and system lumens shall not be less than 9,000. Optics shall be properly designed with Polycarbonate Lenses to avoid dark patches on the road. Street light without lenses will not be acceptable. Driver shall be 3 stage \\"Constant Current Constant Voltage\\" with voltage range of 150-270V AC. Output voltage of driver should be complied to Safety Extra Low Voltage norms not exceeding 60 V DC complete all as specified and directed.Note: (i) The item rate shall deem to include provision of weather proof PVC insulated aluminium conductor cable 2.5 Sqmm, 2 core as required.(ii) Contractor shall produce warranty certificate of association with LED manufacturer for minimum two years. |
| 5 | M&L for 40 mm bore or next suitable size ( for LED fittings) light grade GI bracket 1.20 mtr long bent to shape by cutting welding and well finishing including MS clamp of flat iron of size 25x5mm suitable length 2 nos complete for steel tubular poles with nuts bolts and painting with two coats of aluminium paint over a coat of primer on MS clamp complete all as specified & directed. |
| 6 | S&F in repair junction box Triple Pole and neutral enclosure compression gland 2 with connector and clamp for pole mounting with two nos of nut bolt and washers and socket complete of size not less than 12\\"x10\\"x4\\" complete all as specified and directed. |
| 7 | S&F in repair flat cable flexible copper of size 1.5 sqmm 3 core, 1100 volt grading complete all as specified and directed. |
| 8 | M&L for cutting of vegetation surrounding transformer, two poles, four pole structure at various sub station / E&M installation and remove to a distance not exc 50 mtr complete all as specified and directed. |
| 9 | Supply & Fixing steel tubing GI light grade 40 mm dia for cable protection passing under Road/Floor or for fixing on walls complete all as specified and directed. |
| 10 | Supply & Fixing steel tubing GI light grade 50 mm dia for cable protection passing under Road/Floor or for fixing on walls complete all as specified and directed. |
| 11 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm, 4 core including taking down existing unserviceable cable and removing from site complete all as specified and directed. |
| 12 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm, 2 core including taking down existing unserviceable cable and removing from site complete all as specified and directed. |
| 13 | Excavation in trenches in hard/dense soil not exceeding1.5 meter wide and not exceeding 1.5metre wide and not exceeding 1.5metre in depth and getting out complete all as specified and directed. |
| 14 | Supply and laying sand cushioning with local dry and clean sand over and under the cable for protection of cable , 80 mm thick before laying the cable 150 mm thick after laying the cable complete all as specified and directed. Note:- Only punned thickness of 180mm shall be measured for payment. |
| 15 | Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250mm x 150mm x 40mm complete all as specified and directed. |
| 16 | Returning filling in with excavated soil, including spreading, leveling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 17 | Removing excavated materials (soil) not exceeding 50metre and depositing where directed at a level not exceeding 1.5 meter above starting point complete all as specified and directed. |
| 18 | Taking down LT UG cable, old bricks, cable covers, GI pipe of any size and description from any position for reuse carefully without damaging and re-laying/re-routing of same in trenches/ wall/ pole/ through pipe complete all as specified and directed.Note:- (i) Bricks, cable cover and GI pipe retrieved from above item shall be re-used in relaying/re-routing of LT cable.(ii) Earth work shall be allowed manually and cost of the same deemed to be include in quoted unit rates. (iii) Only sand cushioning shall be measured and paid seperatly under respective item. |
| 19 | S&F tiranga LED rope light Indian Tricolor strip light Orange,White, Green Colour in a single strip 15 meter plug and play waterproof IP65 Strip meter Plug and Play waterproof IP65 Strip Light Post Light Outdoor Lamp complete all as specified and directed. |
| 20 | Supply and fix water level indicator of measuring 2mtr ,material stainless steel , type-Float and board level indicator, complete all as specified and as directed |
| 21 | Supply and fix RCC pipe line route marker of size 900x150x100mm thick and writing MES PIPE LINE letter size 50x30mm complete all as specified and as directed |
| 22 | Supply and fix Foot Valve conforming to IS 4038, 80 mm (3”) dia complete all as specified and directed. |
| 23 | Supply and fix CI Non Return Valve of size 80mm dia complete all as specified and directed. |
| 24 | Supply and fix Fully automatic star delta Starter 3 Ph,415 Volts, suitable for 50 HP - 01 No including accessories complete all as specified and directed. |
| 25 | M & L for painting of CI /GI/MS pipe line with one coat of red oxide , zinc chrome and two coats of anti corrosive synthetic enamel paint including prearation of old painted surface complete all as specified and as directed .Note:- Inlet pipe should be painted in blue colour , out let pipe should be painted in green colour and over flow pipe should be painted in yellow colour. |
| 26 | S&F in repair DOL Starter 3 Ph,415 Volts, suitable for 10 HP - 01 No including accessories complete all as specified and directed. |
| 27 | S&F in repair DOL Starter 3 Ph,415 Volts, suitable for 05 HP - 02 No including accessories complete all as specified and directed. |
| 28 | S&F in repair DOL Starter 3 Ph,415 Volts, suitable for 15 HP - 02 No including accessories complete all as specified and directed. |
| 29 | S&F in repair stranded aluminium conductor flat twin core PVC insulated unsheathed 1100V 10 Sqmm 2 core complete all as specified and directed. |
| 30 | M&L for PVC conduit 20mm dia including fixing on wall/pole with necessary fixing arrangement complete all as specified and directed. |
| 31 | M&L for Bus Bar Panel of capacity 200 Amps copper bus bar 04 Nos with fixed on insulator welded with iron angle of size 40x40x6 mm thick and 60cm height grouting in floor, 0.45 mm depth grouting with PCC 1:3:6 upto ground level complete all as specified and directed. |
| 32 | Supply, erecting and fixing of steel tubular swaged pole (410 SP – 31) conforming to IS 2713 (part 1 to 3), 9 mtr long with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, including two coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint including dismantling of old unserviceable pole complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed).Note: (a) Cost of numbering of pole shall be deemed to included in unit rate.(b) Earth work and PCC will be measured and paid for separately under respective item here-in-after.(c) The pole shall be marked with designation, manufacturer's identification and year of manufacture(d) The Contractor shall submit test certificate of pole. |
| 33 | M & L for plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate in foundation of PCC poles/ struts, etc. including form work complete all as specified and directed |
| 34 | M & L for plain cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation of stay assy/ pole etc, including form work complete all as specified and directed |
| 35 | M & L for plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate for coping/plinth of poles, including necessary form work finished even & smooth without using extra cement complete all as specified and directed |
| 36 | S&F in repair LED bollard 8W, two feet height IP 65 as a imposing street furniture. The elegant yet minimalsitic design acts silent observer and giving lihgt, diffuser at the upper portion acts a beacon of path guidance in a landscape environment complete all as specified and as directed. |
| 37 | Supply, laying and spreading of 40mm graded stone aggregate complete all as specified and directed. |
| 38 | M & L for painting of PCC pole (Cross arms, clamps etc) with 2 coats of aluminium paints and including preparation of surfaces and painting upto the height of 1.2 m pole 9 m long with 2 coats of synthetic enameled paint including preparation of old surfaces and making colour bands and rewriting the pole number complete all as specified and directed. |
| 39 | M & L for painting of tubular/ rail pole (Cross arms, clamps etc) with 2 coats of aluminium paints and including preparation of surfaces and painting upto the height upto 9 m pole with 2 coats of synthetic enameled paint including preparation of old surfaces and making colour bands and rewriting the pole number complete all as specified and directed. |
| 40 | Cutting /trimming of tree branches upto 80 mm girth along LT/HT OH electric lines which or growing /touching or falling on ACSR conductor /poles or near by sub stns etc at any height from GL and making sufficient clearance not less than 1.5 mtr from ACSR conductor/ poles/ structure and taking down the same on the ground carefully avoiding the damage of and removing to a distance including stretching of conductor as required where directed by Engr - in -charge. Note :- Tree cutting will be maintain for periodicity for three months depending upon the grougth of three branches. Please Enable Macros to View BoQ information |