| 1 | M&L Removal of old APP Based membrane of any description, hacking out of plaster underneath and cleaning the roof surface complete all as specified and directed. |
| 2 | M&L of 10mm thick rendering on top of roof surfaces of any description in cement mortar 1:4 mixed with liquid WPC , surface finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured & paid seperately. |
| 3 | M&L bitumenous based primer conforming to IS-3384-1965 @ 0.40 Kg / Sqm including preparation of roof surface complete all as specified and as directed. |
| 4 | M&L for APP based polymeric membrane minimum weighing 3.5 kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by torch application method complete all as specified and directed. |
| 5 | M&L for after laying the membrane apply two coats of aluminium paint @ 200 gm/Sqm (minimum) in two coats complete all as specified and directed. |
| 6 | Supply only integral liquid water proofing compound (ISI marked) complete all as specified and directed. |
| 7 | Supply and fixing Heat Resistant Terrace Tiles of size (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid over and including screed bed of 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner complete all as specified and directed. |
| 8 | Demolition of concrete of any description in any position complete all as specified and directed. |
| 9 | M&L for cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate ) as in roof kerbs, mud stops, rounded or chamfered on edges, leveling course in floor etc complete all as specified and directed. |
| 10 | Taking down cement plaster, terrazzo dado in any thickness from brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc including removal of rubbish, vegetation etc outside complex (MOD land) complete all as specified and directed. |
| 11 | M & L for 15 mm thick rendering in two layer (1st layer 10 mm thick & second layer 5 mm thick) on wall/concrete surface with cement mortar (1 : 4) finished even and smooth (without using extra cement) with liquid WPC complete all as specified and directed. (WPC Shall be measured seprately) |
| 12 | M&L for preparation of old decorated surface of exterior/Interior wall/Ceiling of projection/chajja by complete removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers and cutting of trunk, branches of tree and Cutting or uprooting grass , then washing the surface with Bleaching powder solution for treatment of fungal applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance, Superior elasticity and covers hairline crack up to 3.2 mm exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of of exterior primer (recommended by paint manufacturer) applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. |
| 13 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance, Superior elasticity and covers hairline crack up to 3.2 mm exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of of exterior primer (recommended by paint manufacturer) applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 14 | M&L for 1 mm thick wall care water proof putty over plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 15 | Taking down eaves gutters and rain water pipes (any size 75mm to 110mm of any pattern) ,of any description and in any position, including all fittings , heads, shoes, bends, swan necks, etc, (measured overall as fixed along the centre line over fittings and accessories)complete all as specified and directed. |
| 16 | S&F 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. |
| 17 | ditto but fixed in wall 110 mm complete all as specified and directed. |
| 18 | S&F 75 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. |
| 19 | ditto but fixed in wall 75 mm complete all as specified and directed. |
| 20 | S& F PVC (SWR) bends any radius 75mm dia with access door or without access door complete all as specified and directed. |
| 21 | S& F PVC (SWR) bends any radius 110 mm dia with access door or without access door complete all as specified and directed. |
| 22 | S& F PVC (SWR) junction single, (Single T) equal or unequal 75mm dia with access door or without access door complete all as specified and directed. |
| 23 | S& F PVC (SWR) junction single, (Single T) equal or unequal 110 mm dia with access door or without access door complete all as specified and directed. |
| 24 | S&F PVC SWR vent cowl 110 mmn dia complete all as specified and directed. |
| 25 | S&F for 100mm bore pipes stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall etc; complete all as specified and directed. |
| 26 | S&F for 75mm bore pipes stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall etc; complete all as specified and directed. |
| 27 | S&F 75 mm PVC (SWR) couplers complete all as specified and directed. |
| 28 | S&F 110 mm PVC (SWR) couplers complete all as specified and directed. |
| 29 | S&F 110 mm PVC (SWR) junction double, (double T), equal or unequal complete all as specified and directed. |
| 30 | S&F 110mm PVC 'P' or 'S' trap, complete all as specified and directed. |
| 31 | S&F 40mm bore steel water tubing medium grade galvanised inserted at the end of lateral slope projecting at least 15cm beyond the outer most projected part of the building below the drain pipe up to two storey construction as spout for sunken complete all as specified and directed. |
| 32 | Taking down 15mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specified and directed. |
| 33 | Taking down 20mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specified and directed. |
| 34 | Supplying and laying of 20 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches and fixed/concealed complete to walls and ceiling or laid in floor etc complete all as specified and directed. |
| 35 | Supplying and laying of 25 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches and fixed/concealed complete to walls and ceiling or laid of in floor etc complete all as specified and directed. |
| 36 | S&F in repair W.C vitreous china, squatting pan orissa patern of size 580x440mm white with intergral foot rest & P or S trap,flush pipe complete excluding flushing cistern complete all as specified and directed. |
| 37 | S&F in repair W.C vitreous china, (pedestal patern ) white (excluding flushing cistern and flush pipes ) including seat cover fixing bolt & P or S trap,flush pipe complete all as specified and directed. |
| 38 | S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 39 | S&F in repair PVC valveless, syphonic action type flushing cistern low level white with inlet ball valve, float and handle incl brackets and connections to pipes of capacity 10 lts complete all as spepciified and directed. Please Enable Macros to View BoQ information |
| 40 | S&F in repair PVC valveless, syphonic action type flushing cistern low level white with inlet ball valve, float and handle incl brackets and connections to pipes of capacity 10 lts complete all as spepciified and directed. Please Enable Macros to View BoQ information |