Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Providing and fixing 200 mm i/d U type C.I. Bend Including tail pieces, glass wool wire gauge, with MS Sheet 3 mm with Holes Nut and Blot and Rubber Sheet etc. complete in all respect.(44Kg. U Type bend and 36 Kg Tail Piece each) |
| 2 | Providing and fixing Float operated water gauge 6” wide 15’ height painted and marked with in feet With bottom flange for fixing and pulley on top with 10” i/d copper ball with steel wire rope complete in all respect. |
| 3 | Providing and fixing aluminum ladder 1’ wide With 1’ center to center aluminum rod of 20 mm i/d complete in all respect. (20’ Long) |
| 4 | Supply and errection of street light Lumination 2x28 watt energy saving fitting as per specification. |
| 5 | Cutting of longitudenal joints 10mm to 12mm width and 150 mm depth of CC pavement for dismantling of CC Streets with cutter machine including all T and P and labour. |
| 6 | Supply of PCCP Pipe (Pre-stressed concrete cylinder)(with 10kg/sq.cm FTP) Rate inlusice all taxes, freight upto site, contractor proffit, excavation of earth, laying, jointing, welding, testing and commissioning complete in all respects.500mm i/d |
| 7 | Supplying, erection, testing and commissioning of Dewatering Pump of 3HP |
| 8 | Supplying, erection and fixing of DI Vent Pipe of size 150mm i/d. |
| 9 | Providing and fixing pressure gauge 6” dia 0-24 kg/sqcm complete in all respect. |
| 10 | LT. ALLUMINIUM CABLE: Supply erection testing of standard make aluminum armound LT cable for 1100 volts (3.5 core x 95 sqm) grade ISI marked Stranded compact circular aluminium conductor, conductor screen with extruded semi conducting compound, XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, innersheath of PVC, galvanised steel flat strip armoured, and overall PVC sheathed cable conforming to is 7098 (part-2) 2011 with up to date amendments for making following connection a) from G.O switch to metering equipment.b) from metering equipment to transformer complete in all respect. Make: Indian Cables Ltd./ Polycab / RR Cables /CAPP / Finolex / Havells / Gloster / Universal / Fort Gloster Industries Ltd./ Indian Cable Co. / Asian Cables Corporation Ltd.95 Sqmm size |
| 11 | LT. ALLUMINIUM CABLE: Supply erection testing of standard make aluminum armound LT cable for 1100 volts (3.5 core x 150 sqm) grade ISI marked Stranded compact circular aluminium conductor, conductor screen with extruded semi conducting compound, XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, innersheath of PVC, galvanised steel flat strip armoured, and overall PVC sheathed cable conforming to is 7098 (part-2) 2011 with up to date amendments for making following connection a) from G.O switch to metering equipment.b) from metering equipment to transformer complete in all respect. Make: Indian Cables Ltd./ Polycab / RR Cables /CAPP / Finolex / Havells / Gloster / Universal / Fort Gloster Industries Ltd./ Indian Cable Co. / Asian Cables Corporation Ltd.150 Sqmm size. |
| 12 | LT COPPER CABLE: Supply, erection, testing and commissioning of is marked PVC Copper insulated and sheathed 3.5 core circular flexible wire 1100 volts (3.5 core x 50 sqm) along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables / CAPP / Gloster / Universal / Fort Gloster Industries Ltd./ Asian Cables Corporation Ltd. 50sqmm 3 core. |
| 13 | Supply, errection and fixing of 9 watt LED light. |
| 14 | Supplying, erection and fixing of Go switch and RCC Pole for Go switch complete in all respect. |
| 15 | Providing and fixing of SS Sign Board with SS Plate of size 2.50 x 1.50 mtr with 3.00 mm thickness and SS Pipe 75mmx75mm including writing slogans on the sign board after painting from synthetic enamal paints in both side complete job. |
| 16 | Supply of PCCP Pipe (Pre-stressed concrete cylinder)(with 10kg/sq.cm FTP) Rate inlusice all taxes, freight upto site, contractor proffit, excavation of earth, laying, jointing, welding, testing and commissioning complete in all respects. 700 mm |
| 17 | Supply of PCCP Pipe (Pre-stressed concrete cylinder)(with 10kg/sq.cm FTP) Rate inlusice all taxes, freight upto site, contractor proffit, excavation of earth, laying, jointing, welding, testing and commissioning complete in all respects. 600 mm |
| 18 | Making connection with 500 mm i/d PCCP Pipe with existing 800 mm i/d DI pipe line, bailing out water, cutting, jointing, testing, providing and fixing all required Pipe and.specials complete job. |
| 19 | Laying of PCCP Pipe line By Trenchless Technology. in normal soil condition but not rock/ bolder/any undergrounds utilities like foundation Road, Drain coming in alignment or other underground obstruction suitable for MS casing pipe of size complete for 1000 mm i/d and 1200 mm i/d MS Pipe 12mm thick casing pipe. consisting with:- 1.Machinery on hire basis, Labour Heavy Hydraulic Crane, Jacking Machine and other necessary equipment Horizontal Boring/ Excavation. 2.Providing and Inserting of 1000mm i/d and 1200mm i/d M.S. casing pipe 12 mm thick(Fe-330 grade)Fabricated as per IS 3589 of 1991 from steel plates confirming to IS:-2062 including cutting, beveling, grinding and jointing with radiographically welding of pipe as per IS- 1182 and testing complete in all respect. 3.Providing and Inserting of 500mm i/d PCCP Pipe and testing complete in all respect. 4.Providing and Fixing of MS Spacer at a distance of 2 Mtrs apart to avoid contract of casing pipe and carrier pipes complete - For 1000mm i/d MS casing pipe of size complete for 500 mm PCCP pipe 5.Excavation for receiving pit of size 6m x 2.50 m x 4 m normal excavation for laying of casing pipe complete to satisfaction of Engineer-in-change. 6.Both side Plugs :-Concrete block 1:1.5:3 on both ends to plug the angular space between casing and carrier pipe complete in all respects. Trench Under Railway Line for 500mm Clear water rising main = 34 meter |
| 20 | Laying of PCCP Pipe line By Trenchless Technology. in normal soil condition but not rock/ bolder/any undergrounds utilities like foundation Road, Drain coming in alignment or other underground obstruction suitable for MS casing pipe of size complete for 1000 mm i/d and 1200 mm i/d MS Pipe 12mm thick casing pipe. consisting with:- 1.Machinery on hire basis, Labour Heavy Hydraulic Crane, Jacking Machine and other necessary equipment Horizontal Boring/ Excavation. 2.Providing and Inserting of 1000mm i/d and 1200mm i/d M.S. casing pipe 12 mm thick(Fe-330 grade)Fabricated as per IS 3589 of 1991 from steel plates confirming to IS:-2062 including cutting, beveling, grinding and jointing with radiographically welding of pipe as per IS- 1182 and testing complete in all respect. 3.Providing and Inserting of 500mm i/d PCCP Pipe and testing complete in all respect. 4.Providing and Fixing of MS Spacer at a distance of 2 Mtrs apart to avoid contract of casing pipe and carrier pipes complete - For 1000mm i/d MS casing pipe of size complete for 500 mm PCCP pipe 5.Excavation for receiving pit of size 6m x 2.50 m x 4 m normal excavation for laying of casing pipe complete to satisfaction of Engineer-in-change. 6.Both side Plugs :-Concrete block 1:1.5:3 on both ends to plug the angular space between casing and carrier pipe complete in all respects. Trench Under Railway Line and KMP Expressway for 500mm Clear water rising main = 124 meter |
| 21 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 200 HP. Enclosure shall be IP66. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensor less Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensor less Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensor less 1, 0 to 120Hz in Sensor less 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete in all respect as required. (At IBS Babra Bakipur) |
| 22 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 100 HP. Enclosure shall be IP66. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensor less Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensor less Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensor less 1, 0 to 120Hz in Sensor less 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete in all respect as required. (At IBS Babra Bakipur) |
| 23 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 60 HP. Enclosure shall be IP66. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensor less Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensor less Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensor less 1, 0 to 120Hz in Sensor less 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete in all respect as required. (At WTP Badli) |
| 24 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 275 HP. Enclosure shall be IP66. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensor less Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensor less Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensor less 1, 0 to 120Hz in Sensor less 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete in all respect as required. (At WTP Badli) |
| 25 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 60 HP. Enclosure shall be IP66. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensor less Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensor less Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensor less 1, 0 to 120Hz in Sensor less 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete in all respect as required. (At WTP Saidpur) |
| 26 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 7.5 HP. Enclosure shall be IP66. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensor less Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensor less Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensor less 1, 0 to 120Hz in Sensor less 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete in all respect as required. (At WTP Saidpur) |
| 27 | Design and construction of automated PLC controlled 12.50 MLD Scada based water treatment plant including interconnecting DI pipe from raw water pump to inlet box of WTP, CWT and Suction Well for CW , inlet channel, Alum dozing, Flash mixing, Clarifloculator, filter box, over head Reservoir for back wash including pump sets and electric control panel, waste water tank including pump sets and electric control panel, DI pipes, DI specials, manhole covers, air scour equipment, chemical house including chlorination equipment and all other civil / mechanical / electric installations complete in all respects as per DNIT (Sluice valves of make IVC/VAG) 12.50 MLD CAPACITY including OandM during Defect liability period of 12 months after trial run period of 3 months and 5 years thereafter. (At Saidpur) |
| 28 | Providing, erection, testing and commissioning of horizontal motor pumping set for clear water having 75 m head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked. Discharge Capacity 6500 LPM (At IBS Babra Bakipur for Nuh.) |
| 29 | Providing, erection, testing and commissioning of horizontal motor pumping set for clear water having 35 m head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked. Discharge Capacity 8500 LPM (At IBS Babra Bakipur for Pataudi plus Haily mandi) |
| 30 | Providing, erection, testing and commissioning of horizontal motor pumping set for raw water having 15 m head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked. Discharge Capacity 11000 LPM (At WTP Badli) |
| 31 | Providing, erection, testing and commissioning of horizontal motor pumping set for clear water having 55 m head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked. Discharge Capacity 13500 LPM (At WTP Badli) |
| 32 | Providing, erection, testing and commissioning of horizontal motor pumping set for raw water having 12.5 m head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked. Discharge Capacity 12750 LPM (At WTP Saidpur) |
| 33 | Providing, erection, testing and commissioning of horizontal motor pumping set for clear water having 15 m head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked. Discharge Capacity 10000 LPM (At WTP Saidpur for Rising main) |
| 34 | Laying of PCCP Pipe line By Trenchless Technology. in normal soil condition but not rock/ bolder/any undergrounds utilities like foundation Road, Drain coming in alignment or other underground obstruction suitable for MS casing pipe of size complete for 1200 mm i/d MS Pipe 12mm thick casing pipe. consisting with:- 1.Machinery on hire basis, Labour Heavy Hydraulic Crane, Jacking Machine and other necessary equipment Horizontal Boring/ Excavation. 2.Providing and Inserting of 1200mm i/d M.S. casing pipe 12 mm thick(Fe-330 grade)Fabricated as per IS 3589 of 1991 from steel plates confirming to IS:-2062 including cutting, beveling, grinding and jointing with radiographically welding of pipe as per IS- 1182 and testing complete in all respect. 3.Providing and Inserting of 800mm i/d PCCP Pipe and testing complete in all respect. 4.Providing and Fixing of MS Spacer at a distance of 2 Mtrs apart to avoid contract of casing pipe and carrier pipes complete - For 1200mm i/d MS casing pipe of size complete for 800 mm PCCP pipe 5.Excavation for receiving pit of size 6m x 2.50 m x 4 m normal excavation for laying of casing pipe complete to satisfaction of Engineer-in-change. 6.Both side Plugs :-Concrete block 1:1.5:3 on both ends to plug the angular space between casing and carrier pipe complete in all respects. For Crossing under GWS Canal of 800mm R/W Inlet chanel = 9 meter |
| 35 | Laying of PCCP Pipe line By Trenchless Technology. in normal soil condition but not rock/ bolder/any undergrounds utilities like foundation Road, Drain coming in alignment or other underground obstruction suitable for MS casing pipe of size complete for 1200 mm i/d MS Pipe 12mm thick casing pipe. consisting with:- 1.Machinery on hire basis, Labour Heavy Hydraulic Crane, Jacking Machine and other necessary equipment Horizontal Boring/ Excavation. 2.Providing and Inserting of 1200mm i/d M.S. casing pipe 12 mm thick(Fe-330 grade)Fabricated as per IS 3589 of 1991 from steel plates confirming to IS:-2062 including cutting, beveling, grinding and jointing with radiographically welding of pipe as per IS- 1182 and testing complete in all respect. 3.Providing and Inserting of 800mm i/d PCCP Pipe and testing complete in all respect. 4.Providing and Fixing of MS Spacer at a distance of 2 Mtrs apart to avoid contract of casing pipe and carrier pipes complete - For 1200mm i/d MS casing pipe of size complete for 800 mm PCCP pipe 5.Excavation for receiving pit of size 6m x 2.50 m x 4 m normal excavation for laying of casing pipe complete to satisfaction of Engineer-in-change. 6.Both side Plugs :-Concrete block 1:1.5:3 on both ends to plug the angular space between casing and carrier pipe complete in all respects. For Crossing under Badli road of 800mm R/W Inlet chanel = 20 meter |
| 36 | Making connection with 350 mm i/d DI Pipe with existing 600 mm i/d DI pipe line, bailing out water, cutting, jointing, testing, providing and fixing all required Pipe and.specials complete job (At IBS Babra Bakipur) |
| 37 | Provision for 1 No screen with a clear opening of 20 mm 75 deg the screen shall have all wetted parts of stainless fabricated from steel grade 304 or superior.in Drain outlet of size 1.80*1.20 complete in all respects. (Inside screen chamber At NCR Chanel) |
| 38 | Providing and fixing of Mild steel Epoxy Painted side wall imbedded Open Channel gate with SS304 Rising type spindle type with CIN Hand wheel operated of gate size 1000x1200 mm as per site suitable for 1.0 m Seating water head (From Invert), Flush bottom Closure, Close top frame gate. with Electric Actuator as IS Specification. complete in all respect as per approved make and directions of Engineer-in-charge as per respective size. Make:- Jash/Indian Valve Company(Nasik) (At NCR Chanel) |
| 39 | Providing and fixing D.I. sluice valves (with cap) including, carriage, loading and unloading and fixing complete with bolts, nuts, rubber insertions etc. complete in all respect as per satisfaction of the Engineer-in-Charge. 350mm |
| 40 | Providing and fixing D.I. sluice valves (with cap) including, carriage, loading and unloading and fixing complete with bolts, nuts, rubber insertions etc. complete in all respect as per satisfaction of the Engineer-in-Charge. 400mm |
| 41 | Providing and fixing D.I. sluice valves (with cap) including, carriage, loading and unloading and fixing complete with bolts, nuts, rubber insertions etc. complete in all respect as per satisfaction of the Engineer-in-Charge. 450mm |
| 42 | Providing and fixing D.I. sluice valves (with cap) including, carriage, loading and unloading and fixing complete with bolts, nuts, rubber insertions etc. complete in all respect as per satisfaction of the Engineer-in-Charge. 700mm |
| 43 | Providing and fixing D.I. sluice valves (with cap) including, carriage, loading and unloading and fixing complete with bolts, nuts, rubber insertions etc. complete in all respect as per satisfaction of the Engineer-in-Charge. 600mm |
| 44 | Providing and fixing D.I. sluice valves (with cap) including, carriage, loading and unloading and fixing complete with bolts, nuts, rubber insertions etc. complete in all respect as per satisfaction of the Engineer-in-Charge. 300mm |
| 45 | Providing and fixing D.I. sluice valves (with cap) including, carriage, loading and unloading and fixing complete with bolts, nuts, rubber insertions etc. complete in all respect as per satisfaction of the Engineer-in-Charge. 500mm |
| 46 | Designing, providing, fixing, testing and commissioning of GASEOUS CHLORINATION SYSTEM having capacity upto 2000 grams/ hrs. as designed having the control of gas upto 20th part of max. dose . The complete system consists of (a) Vacuum regulator (b) Measuring Glass Tube (c ) Ejector (d) PF tubing (e) Spanner with cylinder opening key (f) Ammonia Gas (Liquid for leaking test) (g) 1’ dia PVC pipe with PVC fitting, ball valves etc. (h) 2 Nos. chlorine gas cylinder capacity 100 Kg. duly certified and approved by BIS and Explosive Department Govt. of India (i) Electronic Chlorine gas leak detector with sensor and hooter (j) Full face mask with canister as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070- 23142 dated 28-02-2024 |
| 47 | Designing, providing, fixing, testing and commissioning of CHLORINE GAS DRY SCRUBBER as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024. |
| 48 | Designing, providing, fixing, testing and commissioning of AUTO-SHUT OFF VALVE as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024 |
| 49 | Designing, providing, fixing, testing and commissioning of ONLINE COLORIMETRIC WATER QUALITY ANALYZER FOR RESIDUAL CHLORINE AND TURBIDITY including RTU-Cum-Gateway with Cellular (GSM, GPRS,4G/L TE,5G, NB-IoT), LoRa or other RF technology for remote data transfer as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024.... |
| 50 | Designing, providing, fixing, testing and commissioning of VACUUM-OPERATED AUTOMATIC SWITCHOVER SYSTEM WITH ALTERNATE CHLORINATOR as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024.. |
| 51 | Automation Panel for integration with VFD with Pump Control Panel, along with Auto/Manual Selection Switch as well as On/Off push button to be provided. Manual selection between pump 1 and pump 2 depending on which to be operated and which to be stand by to be provided, along with all relay interlocks and provision of operation of pumps through potential free/open collector digital outputs of RTU-cum-Gateway device. The panel will contain RTU-cum-Gateway with necessary I/Os and edge controller function, logic to operate PUMP and Motorized control valve in Local / Remote or Auto/ Manual modes of operation in tandem with Cloud Scheduler or Level sensor-based functions. Panel will contain SMPS with rechargeable battery backup (min. 24 hrs.) along with facility to connect all field instruments with 24 VDC power supply. with five year maintenance period. (1 nos at WW Badli, 1 nos at WW Iqbalpur, 1 nos at WW Saidpur, 1 nos at IBS Babra bakipur, 1 nos at IBS Sehsola, 5 nos at Farukhnagar Bossters(BS-1, BS-2, BS-3, BS-4 and BS-5), 1 nos BS Saidpur vill., 1 nos BS Mohammadpur vill., 1 nos BS Khaintawas vill., 1 nos BS Dhanwas vill. And 1 nos BS Jhund Sarai vill.) |
| 52 | Supply, Installation, Testing, Commissioning with Maintenance of five year of Online Chlorine Sensor to be installed at Pump End/Source. (1 nos at IBS Babra bakipur, 1 nos at IBS Sehsola, 5 nos at Farukhnagar Bossters(BS-1, BS-2, BS-3, BS-4 and BS-5), 1 nos BS Saidpur vill., 1 nos BS Mohammadpur vill., 1 nos BS Khaintawas vill., 1 nos BS Dhanwas vill. And 1 nos BS Jhund Sarai vill.) |
| 53 | Supply, Installation, testing, Commissioning with Maintenance of five year Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement. (IP-68), RS-485 ModBus. Line Size, installed at Pump End/Source. 350mm (2 nos on Farukhnagar CW RM in feild and 1 nos at WW Saidpur) |
| 54 | Supply, Installation, testing, Commissioning with Maintenance of five year Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement. (IP-68), RS-485 ModBus. Line Size, installed at Pump End/Source. 450mm (2 nos on Pataudi CW RM in feild) |
| 55 | Supply, Installation, testing, Commissioning with Maintenance of five year Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement. (IP-68), RS-485 ModBus. Line Size, installed at Pump End/Source. 500mm (1 nos at WW Saidpur on CW RM and 1 nos at feild on CW RM) |
| 56 | Supply, Installation, testing, Commissioning with Maintenance of five year Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement. (IP-68), RS-485 ModBus. Line Size, installed at Pump End/Source. 600mm (1 nos at inlet RW WW Saidpur, 2 nos at IBS Babra bakipur on outlet CW RM, 3 nos on Pataudi CW RM in feild and 1 nos at IBS Sehsola inlet CW RM) |
| 57 | Supply, Installation, testing, Commissioning with Maintenance of five year Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement. (IP-68), RS-485 ModBus. Line Size, installed at Pump End/Source. 800mm (1 nos at IBS Babrabakipur inlet CW RM and 2 nos on CW RM from Badli on feild) |
| 58 | Supply, Installation, testing, Commissioning with Maintenance of five year Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement. (IP-68), RS-485 ModBus. Line Size, installed at Pump End/Source. 900mm (1 nos at outlet WW Badli) |
| 59 | Supply, Installation, testing, Commissioning with Maintenance of five year Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement. (IP-68), RS-485 ModBus. Line Size, installed at Pump End/Source. 1000mm (1 nos at outlet WW Iqbalpur) |
| 60 | Supply, Installation, testing, Commissioning with Maintenance of five year of Pressure Transmitter along with its installation complete in all respect as per specifications. Measuring range – 10 kg/cm2, Output – 4 to 20 mA, to be installed at tail end/remote location (3 nos on CW RM From Badli WW, 5 nos at Farukhnagar Bossters(BS-1, BS-2, BS-3, BS-4 and BS-5), 1 nos on RW RM Iqbalpur WW, 1 nos inlet and 2 nos outlet at WW Saidpur, 3 nos on CW RM From Babra bakipur and 1 nos on CW RM for IBS Sehsola) |
| 61 | Field Instrumentation Panel comprising of RTU-Cum-Gateway with RS485/Modbus as well as discrete AI/DI to interface with remote location instruments like Field Flowmeter, Chlorine Analyzer and/or Pressure Transmitter etc. Power Supply based on solar panel of adequate capacity and rechargeable batteries with 24VDC output meant for smooth permanent operation of instruments connected to be provided. This panel will contain RTU-cum-Gateway and will be wired for full functionality as desired. with five year maintenance period. (4 nos on CW RM From Badli WW, 1 nos CW RM from Saidpur WW and 8 nos on CW RM from IBS Babrabakipur) |
| 62 | `Cloud based software comprising of Middleware, Database and Front-end web interface through suitable Dashboards, Aggregation screens and GIS assisted drill-down from macro to micro to be provided. Application data hosting and maintenance for Five years included in scope. Cloud services of Ministry of Electronics and Information Technology (Meity), Government of India empaneled cloud service providers shall be taken like Microsoft, Amazon, Google, BSNL etc. Cloud service provider must adhere the security standards and guidelines issued by Meity from time-to-time. As the data belongs to the State Government of Haryana, therefore the application and data hosted on Cloud must be kept and stored in data centres located in India only. Any change in application requirement or infrastructure shall be borne by the Implementation agency. Implementation agency shall carry out the Application Security Audit from a Certified Auditor (CA). Application and data shall be kept confidential and only the authorized users shall have the access to it. Implementation Agency shall be responsible for any data theft or data leakages.` |
| 63 | SIM Card for Five year operation of all the instrument above as required. (For 15 nos automation panal and 13 nos field Instrumentation Panel) |
| 64 | Supply, Installation, testing, Commissioning with Five year maintenance of Butterfly Valve with Electrical Actuator Body Material - CI/DI Pressure Rating – PN16 Feedback - 100% Open and 100% close **Unit Rate given, actual quantity to be ascertained while placing order. 350mm (1 nos at Farukhnagar CW RM in feild) |
| 65 | Supply, Installation, testing, Commissioning with Five year maintenance of Butterfly Valve with Electrical Actuator Body Material - CI/DI Pressure Rating – PN16 Feedback - 100% Open and 100% close **Unit Rate given, actual quantity to be ascertained while placing order. 600mm (1 nos at inlet RW WW Saidpur and 1 nos at inlet CW IBS Sehsola) |
| 66 | Supply, Installation, testing, Commissioning with Five year maintenance of Butterfly Valve with Electrical Actuator Body Material - CI/DI Pressure Rating – PN16 Feedback - 100% Open and 100% close **Unit Rate given, actual quantity to be ascertained while placing order. 800mm (1 nos at inlet CW At IBS Babra Bakipur) |
| 67 | Functional Integration at RTU-cum- Gateway for Motorized Control Valve in Pump Control Panel. With five year maintenance. (1 nos for each Butterfly Valve) |
| 68 | Supply, Installation, testing, Commissioning with Maintenance of five year of Radar and Water Level Transmitter along with according to water level in UGT (for UGT) Ingress Protection – IP 66, Measuring range – Up to 20 M, Process temp.- -40 to 60 deg. C, Full PVDF Body – For a long sensor lifetime **Unit Rate given, actual quantity to be ascertained while placing order (5 nos at WW Saidpur, 2 nos at IBS Babra bakipur, 2 nos at IBS Sehsola, 5 nos at Farukhnagar Bossters(BS-1, BS-2, BS-3, BS-4 and BS-5), 1 nos BS Saidpur vill., 1 nos BS Mohammadpur vill., 1 nos BS Khaintawas vill., 1 nos BS Dhanwas vill. And 1 nos BS Jhund Sarai vill.) |
| 69 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 150 HP. Enclosure shall be IP66. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete in all respect as required. (At RWBS Iqbalpur WW) |
| 70 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 60 HP. Enclosure shall be IP66. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete in all respect as required. (2 nos at BS-1(Chandnagar dhani) Farukhnagar) |
| 71 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 50 HP. Enclosure shall be IP66. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete in all respect as required. (2 nos at BS-1(Chandnagar dhani) Farukhnagar) |
| 72 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 25 HP. Enclosure shall be IP66. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete in all respect as required. (2 nos at BS-2(Sees mahal) Farukhnagar) |
| 73 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 30 HP. Enclosure shall be IP66. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete in all respect as required. (2 nos at BS-3(Civil hospital), 2 nos at BS-4(Samsan Ghat) and 2 nos at BS-5(Gaushala) Farukhnagar) |
| 74 | Supply of PCCP Pipe (Pre-stressed concrete cylinder)(with 10kg/sq.cm FTP) Rate inclusive all taxes, freight upto site, contractor profit, excavation of earth, laying, jointing, welding, testing and commissioning complete in all respects. 1000mm. |
| 75 | Providing and fixing D.I. sluice valves (with cap) including, carriage, loading and unloading and fixing complete with bolts, nuts, rubber insertions etc. complete in all respect as per satisfaction of the Engineer-in-Charge. 1000mm |
| 76 | Laying of PCCP Pipe line By Trenchless Technology. in normal soil condition but not rock/ bolder/any undergrounds utilities like foundation Road, Drain coming in alignment or other underground obstruction suitable for MS casing pipe of size complete for 1600 mm i/d and 1800 mm i/d MS Pipe 12mm thick casing pipe. consisting with:- 1.Machinery on hire basis, Labor Heavy Hydraulic Crane, Jacking Machine and other necessary equipment Horizontal Boring/ Excavation. 2.Providing and Inserting of 1600mm i/d and 1800mm i/d M.S. casing pipe 12 mm thick(Fe-330 grade)Fabricated as per IS 3589 of 1991 from steel plates confirming to IS:-2062 including cutting, beveling, grinding and jointing with radiographically welding of pipe as per IS- 1182 and testing complete in all respect. 3.Providing and Inserting of 1000mm i/d PCCP Pipe and testing complete in all respect. 4.Providing and Fixing of MS Spacer at a distance of 2 Mtrs apart to avoid contract of casing pipe and carrier pipes complete - For 1600mm i/d MS casing pipe of size complete for 1000 mm PCCP pipe 5.Excavation for receiving pit of size 6m x 2.50 m x 4 m normal excavation for laying of casing pipe complete to satisfaction of Engineer-in-change. 6.Both side Plugs :-Concrete block 1:1.5:3 on both ends to plug the angular space between casing and carrier pipe complete in all respects. For Crossing under Railway line of 1000mm R/W Rising main = 41 meter |
| 77 | Laying of PCCP Pipe line By Trenchless Technology. in normal soil condition but not rock/ bolder/any undergrounds utilities like foundation Road, Drain coming in alignment or other underground obstruction suitable for MS casing pipe of size complete for 1600 mm i/d and 1800 mm i/d MS Pipe 12mm thick casing pipe. consisting with:- 1.Machinery on hire basis, Labor Heavy Hydraulic Crane, Jacking Machine and other necessary equipment Horizontal Boring/ Excavation. 2.Providing and Inserting of 1600mm i/d and 1800mm i/d M.S. casing pipe 12 mm thick(Fe-330 grade)Fabricated as per IS 3589 of 1991 from steel plates confirming to IS:-2062 including cutting, beveling, grinding and jointing with radiographically welding of pipe as per IS- 1182 and testing complete in all respect. 3.Providing and Inserting of 1000mm i/d PCCP Pipe and testing complete in all respect. 4.Providing and Fixing of MS Spacer at a distance of 2 Mtrs apart to avoid contract of casing pipe and carrier pipes complete - For 1600mm i/d MS casing pipe of size complete for 1000 mm PCCP pipe 5.Excavation for receiving pit of size 6m x 2.50 m x 4 m normal excavation for laying of casing pipe complete to satisfaction of Engineer-in-change. 6.Both side Plugs :-Concrete block 1:1.5:3 on both ends to plug the angular space between casing and carrier pipe complete in all respects. For Crossing under Railway line of 1000mm R/W Rising main = 24 meter |
| 78 | Providing, erection, testing and commissioning of horizontal motor pumping set for raw water having 20 m head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked. Discharge Capacity 18100 LPM (At Iqbalpur WW) |
| 79 | Supply, Installation, testing, Commissioning with Maintenance of five year Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement. (IP-68), RS-485 ModBus. Line Size, installed at Pump End/Source. 100mm (1 nos at outlet BS-3 Farukhnagar, 1 nos at inlet BS Babra bakipur vill. and 1 nos at inlet BS no.13 Dewlawas vill.) |
| 80 | Supply, Installation, testing, Commissioning with Maintenance of five year Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement. (IP-68), RS-485 ModBus. Line Size, installed at Pump End/Source. 150mm (1 nos at CW RM for Jhund sarai, 1 nos at inlet BS-3 Farukhnagar, 1 nos at BS-4 Farukhnagar, 1 nos at outlet WW Saidpur, 1 nos at inlet BS Saidpur vill., 1 nos at inlet BS Mohammadpur vill., 1 nos at inlet BS Khaintawas vill., 1 nos at inlet BS Dhanwas vill., 1 nos at inlet BS Jhund Sarai vill., 1 nos at inlet BS no.6 Heraheri vill., 1 nos at inlet BS no.7 Khanpur vill., 1 nos at inlet BS no.14 Mirzapur vill., 1 nos at inlet BS no.15 Milakpur vill. and 1 nos at inlet BS no.16 Chawan vill.) |
| 81 | Supply, Installation, testing, Commissioning with Maintenance of five year Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement. (IP-68), RS-485 ModBus. Line Size, installed at Pump End/Source. 200mm (1 nos at CW RM for Khaintawas vill., 2 nos at inlet and outlet BS-1 Farukhnagar, 2 nos at inlet and outlet BS-2 Farukhnagar, 1 nos at inlet BS-5 Farukhnagar, 2 nos on Pataudi CW RM in feild, 1 nos at inlet BS no.1 Rampur vill., 1 nos at inlet BS no.2 Janaula vill., 1 nos at inlet BS no.3 Janaula road(Pataudi), 1 nos at inlet BS no.5 Narhera vill., 1 nos at inlet BS no.9 Sri ram chowk(Haily mandi), 1 nos at inlet BS no.10 At Disposal(Hailymandi), 1 nos at inlet BS no.11 Om colony(Hailymandi) and 1 nos at inlet IBS 2 Sri ram chowk(Hailymandi)) |
| 82 | Supply, Installation, testing, Commissioning with Maintenance of five year Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement. (IP-68), RS-485 ModBus. Line Size, installed at Pump End/Source. 250mm (1 nos at outlet BS-3 Farukhnagar, 1 nos at outlet BS-5 Farukhnagar, 1 nos at inlet BS no.4 Near court(Pataudi), 1 nos at inlet BS no.8 Shiv murti park(Pataudi) and 1 nos at inlet BS no.12 Palhawas road(Haily mandi)) |
| 83 | Supply, Installation, testing, Commissioning with Maintenance of five year Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement. (IP-68), RS-485 ModBus. Line Size, installed at Pump End/Source. 300mm (1 nos at outlet BS-1 Farukhnagar, 1 nos at outlet BS-4 Farukhnagar, 1 nos at WW Saidpur, 2 nos on Pataudi CW RM in feild and 1 nos at inlet IBS 1 Khor road (Pataudi)) |
| 84 | Supply, Installation, testing, Commissioning with Five year maintenance of Butterfly Valve with Electrical Actuator Body Material - CI/DI Pressure Rating – PN16 Feedback - 100% Open and 100% close **Unit Rate given, actual quantity to be ascertained while placing order. 100mm (1 nos at inlet BS Babra bakipur vill. and 1 nos at inlet BS no.13 Dewlawas vill.) |
| 85 | Supply, Installation, testing, Commissioning with Five year maintenance of Butterfly Valve with Electrical Actuator Body Material - CI/DI Pressure Rating – PN16 Feedback - 100% Open and 100% close **Unit Rate given, actual quantity to be ascertained while placing order. 150mm (1 nos at inlet BS-3 Farukhnagar, 1 nos at BS-4 Farukhnagar, 1 nos at inlet BS Saidpur vill., 1 nos at inlet BS Mohammadpur vill., 1 nos at inlet BS Khaintawas vill., 1 nos at inlet BS Dhanwas vill., 1 nos at inlet BS Jhund Sarai vill., 1 nos at inlet BS no.6 Heraheri vill., 1 nos at inlet BS no.7 Khanpur vill., 1 nos at inlet BS no.14 Mirzapur vill., 1 nos at inlet BS no.15 Milakpur vill. and 1 nos at inlet BS no.16 Chawan vill.) |
| 86 | Supply, Installation, testing, Commissioning with Five year maintenance of Butterfly Valve with Electrical Actuator Body Material - CI/DI Pressure Rating – PN16 Feedback - 100% Open and 100% close **Unit Rate given, actual quantity to be ascertained while placing order. 200mm (1 nos at inlet BS-1 Farukhnagar, 1 nos at inlet BS-2 Farukhnagar, 1 nos at inlet BS-5 Farukhnagar, 1 nos at inlet BS no.1 Rampur vill., 1 nos at inlet BS no.2 Janaula vill., 1 nos at inlet BS no.3 Janaula road(Pataudi), 1 nos at inlet BS no.5 Narhera vill., 1 nos at inlet BS no.9 Sri ram chowk(Haily mandi), 1 nos at inlet BS no.10 At Disposal(Hailymandi), 1 nos at inlet BS no.11 Om colony(Hailymandi) and 1 nos at inlet IBS 2 Sri ram chowk(Hailymandi)) |
| 87 | Supply, Installation, testing, Commissioning with Five year maintenance of Butterfly Valve with Electrical Actuator Body Material - CI/DI Pressure Rating – PN16 Feedback - 100% Open and 100% close **Unit Rate given, actual quantity to be ascertained while placing order. 250mm (1 nos at inlet BS no.4 Near court(Pataudi), 1 nos at inlet BS no.8 Shiv murti park(Pataudi) and 1 nos at inlet BS no.12 Palhawas road(Haily mandi)) |
| 88 | Supply, Installation, testing, Commissioning with Five year maintenance of Butterfly Valve with Electrical Actuator Body Material - CI/DI Pressure Rating – PN16 Feedback - 100% Open and 100% close **Unit Rate given, actual quantity to be ascertained while placing order. 300mm (1 nos at inlet IBS 1 Khor road(Pataudi)) |
| 89 | Operation and maintenance for the complete scope of work mention in the DNIT for a period of 6 year (including defect liability period of 6 years) after successful 3 months trial run period (will be charged to the A/Mtc. Estimate).1st year |
| 90 | Operation and Maintenance during 2nd year. |
| 91 | Operation and Maintenance during 3rd year. |
| 92 | Operation and Maintenance during 4th year. |
| 93 | Operation and Maintenance during 5th year. |
| 94 | Operation and Maintenance during 6th year |
| 95 | The Total value of Schedule4 Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail