| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. .2.8 |
| 2 | All kinds of soil. .2.8.1 |
| 3 | Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :: .2.10 |
| 4 | All kinds of soil .2.10.1 |
| 5 | Pipes, cables etc, not exceeding 80 mm dia. .2.10.1.1 |
| 6 | Pipes, cables etc. exceeding 80 mm dia. but notexceeding 300 mm dia .2.10.1.2 |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : .4.1 |
| 8 | 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) .4.1.4 |
| 9 | 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) .4.1.10 |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). .5.3 |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for .5.9 |
| 12 | Foundations, footings, bases of columns, etc. for mass concrete .5.9.1 |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. .5.22 |
| 14 | Cold twisted bars .5.22.3 |
| 15 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. Cooler stand & gratings made out of MS angle 40 x40x 5 and MS flat 32x5mm respectively. .10.25 |
| 16 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works .10.25.2 |
| 17 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. .15.2 |
| 18 | Nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix) .15.2.1 |
| 19 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : .17.3 |
| 20 | W.C. pan with ISI marked white solid plastic seat and lid .17.3.1 |
| 21 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: .17.7 |
| 22 | white Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps .17.7.3 |
| 23 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. .17.16.A |
| 24 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. .17.28 |
| 25 | Flexible pipe .17.28.2 |
| 26 | 32 mm dia .17.28.2.1 |
| 27 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 5 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. .17.31 |
| 28 | providing and fixing soil, waste and vent pipes. .17.35 |
| 29 | 100 mm diamete .17.35.1 |
| 30 | Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 .17.35.1.2 |
| 31 | 75 mm diameter : .17.35.2 |
| 32 | Centrifugally cast (spun) iron socketed pipe as per IS: 3989 .17.35.2.2 |
| 33 | Providing and fixing heel rest sanitary bend .17.40 |
| 34 | 100 mm dia .17.40.1 |
| 35 | Sand cast iron S&S as per IS - 3989 .17.40.1.2 |
| 36 | providing and fixing collar .17.57 |
| 37 | 100 mm .17.57.1 |
| 38 | Sand cast iron S&S as per IS - 3989 .17.57.1.2 |
| 39 | 75 mm .17.57.2 |
| 40 | Sand cast iron S&S as per IS - 3989 .17.57.2.2 |
| 41 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : .17.58 |
| 42 | 100 mm .17.58.1 |
| 43 | 75 mm dia .17.58.2 |
| 44 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : .17.60 |
| 45 | 100 mm inlet and 75 mm outlet .17.60.2 |
| 46 | Sand cast iron S&S as per IS - 3989 .17.60.2.1 |
| 47 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.Internal work - Exposed on wall .18.10 |
| 48 | 40 mm dia nominal bore .18.10.5 |
| 49 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, including making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall: .18.11 |
| 50 | 15 mm dia nominal bore .18.11.1 |
| 51 | 20 mm dia nominal bore .18.11.2 |
| 52 | Providing and fixing uplasticised PVC connection pipe with brass unions : .18.21 |
| 53 | 45 cm length .18.21.2 |
| 54 | 15 mm dia nominal bore .18.21.2.1 |
| 55 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : .18.46 |
| 56 | 15 mm dia nominal bore .18.46.1 |
| 57 | 20 mm dia nominal bore .18.46.2 |
| 58 | 25 mm dia nominal bore .18.46.3 |
| 59 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. .18.48 |
| 60 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : .18.49 |
| 61 | 15 mm dia nominal bore .18.49.1 |
| 62 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 .18.53 |
| 63 | 15 mm dia nominal bore .18.53.1 |
| 64 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : .19.1 |
| 65 | 200 mm diameter .19.1.3 |
| 66 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : .19.2 |
| 67 | 150 mm diameter S.W. pipe .19.2.2 |
| 68 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: .19.4 |
| 69 | 100x100 mm size P type .19.4.1 |
| 70 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 .19.4.1.1 |
| 71 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality .19.19 |
| 72 | H D - 20 .19.19.3 |
| 73 | 19.19.3.1 .19.19.3.1 |
| 74 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : .19.21 |
| 75 | For pipes 100 to 250 mm diameter .19.21.1 |
| 76 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominalsize), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cementon walls and bed concrete etc. complete as per standard design: .19.3 |
| 77 | Inside dimensions 455x610 mm and 45 cm deep for singlepipe line : .19.30.1 |
| 78 | With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 .19.30.1.1 |
| 79 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards .NSR |
| 80 | 15 mm dia nominal bore . |
| 81 | Providing and fixing white vitreous china flat back half stall urinal CAPRIANA 375 x 390 x 590 mm Cat. No. S4020112* with fitting complete make cera complete in all respect. .NSR Please Enable Macros to View BoQ information |