Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Civil Works |
| 2 | Plumnbing Works |
| 3 | Electrical Works |
| 4 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 30 mm, removal of stumps of such trees cut earlier and disposal of unserviceable material to be used or auctioned upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.B. By Mechanical Meansi. In area of non-thorny jungle |
| 5 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m |
| 6 | Earth work in excavation by manual mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 in in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 in and lift up to 1.5 in, as directed by Engineer-in-charge.(a) All kinds of soil |
| 7 | Earthwork in excavation by Mechanical means up to a depth of 2 m below the existing ground level tor foundation, trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils. ln ordinary rock (soft rock/ medium rock/ hard shale) |
| 8 | Earthwork in excavation by Mechanical means up to a depth of 2 m below the existing ground level for foundation, trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils. b. ln ordinary rock (soft rock/ medium rock/ hard shale) |
| 9 | Earthwork in excavation by manual means up to a depth of 2m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal Of surplus earth with all lead and lifts as directed and specified for the following classification of soils. (a) (a) All kind of soil (ordinary soil/hard soil/dense) |
| 10 | Construction of retaining walls/breast walls in cement mortar 1:5 as per drawing and Technical specification Clause 1604. III Marshy Soil. (iii) Stone Masonry in cement mortar 1:5 |
| 11 | Providing soling with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, completeb.i.100 mm |
| 12 | Providing soling with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.(b) Stone soling (ii) 150mm |
| 13 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) |
| 14 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curingcomplete (shuttering where necessary shall be measured and paid separately). |
| 15 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level with:a. Cement Mortar 1:6 (1 cement : 6 Coarse sand) |
| 16 | Random rubble masonry with hard stone in superstructure above plinth level and up to tirst floor level, including levemng up with cement concrete 1 :6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) at window sill, ceiling level and the like.a. Cement Mortar 1:6 (1 Cement : 6 Course Sand) |
| 17 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation etc in layers not exceeding 20 cm thick including breaking of clods, consolidating each layer by ramming and watering, lead up to 50 m and lift up to 1.5 ma. WIth available Excavated earth |
| 18 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 19 | Supplying, fitting and fixing in position reinforcement bars up to 1st floor level, conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required)Thermo-Mechanically Treated bars |
| 20 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required) |
| 21 | Shuttering / Formwork Centering and shuttering lncluding strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge. |
| 22 | Foundations, footings, bases of columns, etc. for mass concrete (using steel). |
| 23 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc (using steel |
| 24 | Columns, Pillars, Piers, Abutments, Posts and struts (using steel). |
| 25 | Stairs/ spiral staircase, (excluding landings) (using timber) |
| 26 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 27 | Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
| 28 | Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards (using timber). |
| 29 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level:M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 30 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, fillets, columns, pillars, posts and struts etc. above plinth level up to first floor level, excluding cost of centering, shuttering, finishing and reinforcement:M20 or 1 :11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 31 | Reinforced cement concrete work in beams, slabs, roofs having slope up to 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to first floor level, excluding the cost of centering, shuttering, finishing and reinforcement |
| 32 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineerin-charge.(a)All works up to plinth level |
| 33 | Extra for providing richer mixes. (a) Providing M-30 grade concrete |
| 34 | Half brick masonry with common burnt clay (non modular) lst class bricks in superstructure above plinth level up to first floor level (a) Cement mortar 1 :3 (1 cement: 3 coarse sand) |
| 35 | Half brick masonry with common burnt clay (non modular) lst class bricks in superstructure above plinth level up to first floor level (b) Cement mortar 1 :4 (1 cement: 4 coarse sand) |
| 36 | Half brick masonry with common burnt clay (non modular) 1stclass bricks in foundations and in plinth: |
| 37 | Providing 12mm thick cement plastering in cement mortar 1:2, 1:3, 1:4 including cleaning the surface, curing and carriage of all material within 200m complete as per Technical Specification. In cement Mortar 1:3 |
| 38 | 12mm thk cement plaster in single coat on rough side of single or half brick wall for columns |
| 39 | 15 mm cement plaster on the rough side of single or half brick wall of mix: |
| 40 | 15 mm thick Cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. |
| 41 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: (b)1 :4 (1 cement: 4 fine sand) |
| 42 | Rough cast plaster up to 10 height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two layers, underlayer 12 mm cement plaster 1 :4 (1 cement: 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement: 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. |
| 43 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to lS:733 and lS:1285, fixing with dash fasteners of required diameter and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, and panelling to be paid for separately): |
| 44 | For fixed portion |
| 45 | Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 46 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing Of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) |
| 47 | Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 48 | Providing and fixing fire resistant door frame of section 50x60 mm on horizontal side & 35x60 mm on vertical sides having built in rebate made out of 1.6 mm thick Gl sheet (Zinc coating not less than 120 gms/sqm) suitable for mounting 120 minutes Fire Bated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96 Kg/cum. The frame will have a provision of G.I, Anchor fasteners 14 nos. (5 each on vertical stile & 4 on horizontal rail of size M10 x 80) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges Of Size 100x89x3 mm for fixing of fire rated glazed shutter. The frame shall be finished with an approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer-in-charge. |
| 49 | Providing and fixing glazing in fire resistant door shutters,fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I.sheet (zinc coating not less than 120 gm/sqm) of size 20x33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c, including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading & special ceramic tape of 5x20 mm size etc. complete in all respect as per NBC 2016, IS:16231 (Part 3):2016 and as per direction of Engineer-in-charge |
| 50 | with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (E120). The manufacturer have to give test report/ certification of fire glass and the glass should have the stamp showing the value of E, EW & El. The glass shall be tested in approved NABL accredited lab or by any other acoreditation body which operates in accordance with lSO/lEC 17011 and accredits labs as per lSO/lEC 17025 for testing and calibration scopes shall be eligible.The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm. |
| 51 | Providing wood works in frames of doors, window, clerestory window and other frames, wrought frame and fixed in position with hold fast lugs or with dash fasteners of required diameter and length.(c) with first class local wood (ii) Champa/ Diengrai |
| 52 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought trained and fixed in position with hold fast lugs or with dash fasteners of required diameter & length a. With Teak wood/ Sissu wood. |
| 53 | Providing and fixing panelling or glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel insert excluding portion inside grooves or rebated to be measured). Panelling for panelled and glazed shutter 25mm to 40mm thick: (c) With 1st class local wood (ii) Champa/ Diengrai |
| 54 | Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) decorative type, core of block board construction with frame of 1 St class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 55 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)a.With Teak wood/ Sissu woodii. 30 mm thick shutters |
| 56 | Providing and fixing bright finished brass handles with screws etc. complete: (b)125 mm |
| 57 | Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc.complete as per direction ot Engineer-in-Charge. |
| 58 | Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar |
| 59 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 60 | Providing and fixing lSl marked M.S. pressed butt hinges bright finished with necessary screws etc. complete: |
| 61 | Providing and fixing bright finished brass door latch with necessary screws etc.complete:(b) 250xl6x5 mm |
| 62 | Providing and fixing lst marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete: (a) 125mm |
| 63 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete(b)200x10mm |
| 64 | Providing, fitting and fixing steel windows (including ventilators) of standard rolled steel sections as per relevant I.S.Code, joints mitred and welded with 15x3xl00mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65 mm and not less than 15 mm wide) bolting device, steel handles, pegs, stays of 300 mm long etc. complete including providing 12x12mm square bars duly welded to steel frame at not more than 12 cm c/c applying a priming coat of red-lead paint etc. complete as per drawing. (a) Openable |
| 65 | Providing & fixing glass panes with putty and glazing clips in steel doors,windows,clerestory windows, all complete with: (a) 5.5 mm thick glass panes |
| 66 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge: € With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) |
| 67 | Providing and fixing glazing in aluminium door. window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge: b. With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) |
| 68 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. |
| 69 | Applying ready mixed priming coat of approved brand and quality as per specifications |
| 70 | Applying one coat of water thinnable cement primer of approved brand and manufacture on surfaces: Water thinnable cement primer |
| 71 | Applying Priming coat: With ready mixed red oxide zinc chromate primer Of approved brand and manufacture on steel galvanised iron/ steel works |
| 72 | Applying priming coat:a.With ready mked pink or Grey primer Of approved brand and manufacture on wood work (hard and soft wood)/ with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood |
| 73 | Providing and applying Plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 74 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, including scaffolding: |
| 75 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, including scaffolding: c.Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 76 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade, including scaffolding: |
| 77 | Providing and laying vitrified floor tiles in different sizes(thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to ls:15622, ofapproved make, in all colours and shades laid on 20 mm thickcement mortar 1:4 (1 cement: 4 coarse sand), jointing withgrey cement slurry @ 3.3 kg/sqm including grouting the jointswith white cement and matching pigments etc„ complete. (a) Size of tile 600x600mm |
| 78 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to lS:15477, in average 6 mm thickness, including grouting of joints(Payment for grouting of joints to be made separately). Premium range |
| 79 | Providing and fixing lst quality ceramic glazed wall tiles conforming to ls:15622 (thickness to be specified by the manufacturer), of approved make, in all colours and shades of any size as approved by Engineer-in-Charge, in walls,skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.(a)Normal range |
| 80 | Providing and laying paver over a base of 100 mm compacted sand gravel including cutting where necessary finished with flush pointing with cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (a) 80 mm thick |
| 81 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 82 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 83 | Steel work welded in built up sections/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. ln gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 84 | Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ opening/ railing with M.S. flats at required spacing in frame all round, square or round M.S. bars with round headed bolts and nuts or screws |
| 85 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gins/sqm (both side inclusive) as per ls:277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia. x 50mm long with 6 mm dia. bolts, other flange Of cleat fixed to the angle hangers of 25xloxo.50 mm of required length with nuts & bolts Of required size and other end Of angle hanger fixed with intermediate G.I. channels 45xl 5xO.9 mm running at the spacing of 1200 mm centre to centre, to the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, Shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips |
| 86 | made out of 2.64 mm dia. x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges Of 20 mm and 30 mm long, the perimeter of ceiling fb(ed to walvpartition with the help Of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing Of gypsum board to ceiling section and perimeter channel with the help Of dry wall screws Of size 3.5x25 mm at 230 mm a/c, including jointing and finishing to a flush finish Of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides ol joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost Of painting with: |
| 87 | Providing and fixing, in position concealed G.I. section for wall panelling using board of required thickness fixed on the W' profile (0.55 mm thick) having a knurled web of 51.55 mm and two flanges of 26 mm each with lips of 10.55 mm, placed @ 610mm c/c in perimeter channel having one flange of 20 mm and another flange of 30 mm with thickness of 0.55 mm and web of length 27 mm. Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves @ 610 mm c/c with fully threaded self-tapping dry wall screws, Board is fixed to the W' profile with 25 mm countersunk ribbed head screws @ 200 mm c/c., all complcte as per drawings & directions of engineer-in-charge, the joints of the boards are finished with specially formulated jointing compound and 48 mm wide jointing tape to provide seamless finish. (b) Multipurpose cement board reinforced with suitable fibre cement screw. (i) 8 mm thick cement fibre board as per lS:14862 |
| 88 | 65 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1 :2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 15 mm thick cement hardener consisting of mix 1 :2 (1 cement hardener mix: 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture's specifications. This includes cost of cement slurry, complete. |
| 89 | Cement concrete floor topping 1:1:2 (1 cement: 1 coarse sand: 2 stone aggregate) finished with a floating coat of neat cement, including cement slurry, completeb. 20 mm thick |
| 90 | Cement concrete floor topping 1:3:6 (1 cement: 3 coarse sand: 6 stone aggregate) finished with a tloating coat Of neat cement, including cement slurry, complete.(b) 20 mm thick |
| 91 | Providing, Supplying,fitting,fixing and laying of dressed stone block walling and tile slab (Cherra/ local stone block) laid on 25mm thick base in cement mortar 1 :3 and jointed with grey cement slurry including clearing, directed. |
| 92 | Providing, Supplying, fitting, fixing and laying of dressed stone block walling and tile slab (Cherra/ local stone block) laid on 25mm thick base in cement mortar 1 :3 and jointed with grey cement slurry including clearing, rubbing etc. complete as directed.b. Cherra stone block (300x150x75) |
| 93 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made Of G.I. wire of dia. 3 mm including strengthening with 2 mm dia. wire or nuts, bolts and washers as required complcte as per the direction Of Engineer-in-charge. |
| 94 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia. 10 in openable length (total length 90 in), having 50 nos. rounds per 6 in length, up to 3 in height of wall with existing angle iron 'Y. shaped placed 2.4 in or 3.00 in apart and with 9 horizontal P.B.T. reinforced barbed wire, stud tied with G.I. staples and a.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-incharge, with reinforced barbed tape (Pl.B.T.)/ Spring core (2.5 mm thick) wire Of high tensile strength of 165 kg/sq.mm with tape (0.52 mm thick) and weight 43.478 gin/in (cost of M.S. angle, C.C. blocks shall be paid separately). |
| 95 | Construction of unlined surface drains of average cross sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3 m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307. B. Mechanical Means |
| 96 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming stone screening /binding materials to fill up the interstices of coarse aggregates, watering and compacting to the required density Grading 1 as per Technical Specification Clause 404.(B) By Mechanical Means |
| 97 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming stone screenings /binding materials to fill up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405B. By Mechanical means |
| 98 | (i) Providing and applying tack coat with penetration grade bitumen (S-90) using bitumen pressure distributor at the specified rate of 0.50 kg/sqm on the prepared WBM surface not primed, cleaned with hydraulic broom as per Technical Specification Clause 503 |
| 99 | Providing laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508.2 |
| 100 | Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510(II) Bitumen 60/70 grade |
| 101 | Maintenance of drains due to erosion including repair, clearing, cleaning, reshaping, regrading, deepening of side drains as well as catch water drains as per Technical Specification Clause 1907. |
| 102 | Providing precast cement concrete Jali 1:2:4 (1 cement: 2coarse sand: 4 graded stone aggregate 6 mm nominal size ),reinforced with 1.6 mm dia. mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete,excluding plastering of the jambs, sills and soffits |
| 103 | Sand gravel (chapter 33-basic rate of major material) (SL.NO 12)- river sand |
| 104 | Stone aggregate (blasted stone aggregate 20mm down graded)(chapter 33-basic rate of major material) (SL.NO 11) |
| 105 | Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and comers, all necessary fittings complete,including applying a priming coat of approved steel primer. (a) Using M.S. angels 40x40x6 mm for diagonal braces |
| 106 | Providing corrugated galvanised Iron sheet roofing of TATA SHAKTEE / SAIL including fitting and fixing necessary galvanised J or L hooks, bolts and nuts 8 mm dia with bitumen washer 25 mm dia x 3 mm thick and 1.6 mm thick limpet washer complete excluding cost of roof truss, purlin etc. |
| 107 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts,nuts and washers, etc., including making necessary connections with rain water pipes complete |
| 108 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. |
| 109 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed togcther at the end by end locks,mounted on specially designed pipe shaft with brackets, side guides and arrangements tor inside and outside locking with push and pull operation complete, including the cost Of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire Of adequate strength conforming to ls:4454 - part 1 and M.S. top cover Of required thickness tor rolling shutters. (a) 80xl.25 mm M.S. laths with 1.25 mm thick top cover |
| 110 | Providing and fixing ball bearing for rolling shutter |
| 111 | Making soak pit 2.5 in diameter 3,0 metre deep with 45x45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter,1.8 in long complete as per standard design |
| 112 | Disposal of surplus earth/ unserviceable material from the work site including loading and unloading complete as directed. (a) First 5 Km |
| 113 | Providing and fixing pre-coated galvanised iron profile sheets (size, shape and pitch Of corrugation as approved by Engineer-in-charge) 0.50 mm(+O.05 a/o) total coated thickness with zinc coating 120 grams per sqm as per ls:277, in 240Mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film Of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 mcter or as desired by Engineer-incharge. The sheet shall be fixed using selfrdrilling/ selftapping screws of size (5.5x55 mm) with EPDM seal, complete up to any pitch in horizontav vertical or ciirved surfaces, excluding the cost of purlins. rafters and trusses and including cutting to size and shape wherever required. |
| 114 | Providing and fixing pro-coated galvanised steel sheet roofing accessories 0.50 mm (+0.05 a/a) total coated thickness, Zinc coating 120 grams per sqm as per ls:277, in 240 Mpa Steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self-drilling/ selftapping screws complete: |
| 115 | Ridge |
| 116 | Gutter: Roof |
| 117 | Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for underground structures as directed by Engineer-in Charge and consisting of: (i) 1st layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1cement: 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the levelling course (levelling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10 mm to12 mm nominal size spreading @ 0.008 cum/sqm thoroughly embedded in the 2nd layer. |
| 118 | Grouting the joints offlooring tiles having joints of 3mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling, grouting and finishing complete as per direction of Engineer-in-charge. |
| 119 | Extra for carriage including loading and unloading and all charges complete beyond the initial lead of 5 Km. |
| 120 | Boulders |
| 121 | Stone Aggregates |
| 122 | Cement |
| 123 | Steel |
| 124 | Bricks |
| 125 | NON-SCHEDULED ITEMS (AS PER MARKET RATE) |
| 126 | MAIN BUILDING |
| 127 | Invisible Hidden Ghost Wood Sliding door fittings |
| 128 | Smart door lock |
| 129 | Berger paints |
| 130 | Externo Stark Puro Tiles |
| 131 | Rockdeck (Rate Analysis) |
| 132 | Venitto sand (Polish) (800x300)mm |
| 133 | Marfig Pearl |
| 134 | Vibrant Woven Vinyl flooring |
| 135 | Pare Soffit |
| 136 | Louvers 50mm thick x 2900mm long |
| 137 | Brick cladding |
| 138 | Panelled glass |
| 139 | Thatched roof |
| 140 | Bamboo support |
| 141 | Glass railing (10mm) |
| 142 | Ittimi rope tilt |
| 143 | Bamboo Ceiling |
| 144 | Alfresco live outdoor |
| 145 | Double Laminated Shingles |
| 146 | Ridge for Double laminated Shingles |
| 147 | UPVC gutter with accessories |
| 148 | Stone Cladding |
| 149 | WPC decking including frame |
| 150 | VILLAGE SHOP |
| 151 | Earthwork in excavation by manual means up to a depth of 2m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal Of surplus earth with all lead and lifts as directed and specified for the following classification of soils. (a) (a) All kind of soil (ordinary soil/hard soil/dense) |
| 152 | Providing soling with stone/ best quality picked jhama brick,sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete (b)(i) 100mm |
| 153 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). |
| 154 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level with |
| 155 | Random rubble masonry with hard stone in superstructure above plinth level and up to tirst floor level, including levemng up with cement concrete 1 :6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) at window sill, ceiling level and the like. |
| 156 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation etc in layers not exceeding 20 cm thick including breaking of clods, consolidating each layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 157 | Supplying, fitting and fixing in position reinforcement bars up to 1st floor level, conforming to relevant I.S. Code for R.C.C. work/ R.B walling including straightening, cleaning, cutting and bending to proper shapes and length as per details,supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs,spacers etc. complete. (Rates inclusive of all wastage,lappage, hooks, chairs, anchorage etc. and no measurement for the same is required) (b) High Yield Strength Deformed bars or Tor Bars |
| 158 | Providing form work of ordinary timber planking of thickness not less than 25mm and removal of the same for concrete members so as to give a rough finish including centering, shuttering, strutting and propping etc., for height of propping and centering of supporting floor to the soffit of the concrete member not exceeding 4.0M as specified for the following items: |
| 159 | Foundations, footings, bases of columns, etc. for mass concrete (using steel) |
| 160 | Columns, Pillars, Piers, Abutments, Posts and struts (using steel). |
| 161 | Lintels, beams, plinth beams, girders, bressumers and cantilevers (using steel). |
| 162 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost Of centerjng, shuttering, finishing and reinforcement- All work up to plinth level: |
| 163 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, fillets, columns, pillars, posts and struts etc. above plinth level up to first floor level, excluding cost of centering, shuttering, finishing and reinforcement: |
| 164 | Half brick masonry with common burnt clay (non modular) lst class bricks in superstructure above plinth level up to first floor level (b) Cement mortar 1 :4 (1 cement: 4 coarse sand) |
| 165 | 15 mm cement plaster on the rough side of single or half brick wall of mix: |
| 166 | 50 mm thick cement concrete flooring with concrcte hardener topping, under layer 38 mm thick cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting Of mix 1 :2 (1 cement hardener mix: 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg Of cemem or as per manufacturer's specifications. This includes cost of cement slurry, complete. |
| 167 | Steel work riveted and/ or bolted/ riveted in built up sections, frame work including cutting, hoisting, fixing in position and applying a priming coat of red- lead paint up to 4.6m height above plinth including drilling holes, supplying, fitting and fixing with bolts and nuts or welding, if necessary as directed. |
| 168 | Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and comers, all necessary fittings complete,including applying a priming coat of approved steel primer. (a) Using M.S. angels 40x40x6 mm for diagonal braces |
| 169 | Applying one coat of water thinnable cement primer of approved brand andmanufacture on surfaces |
| 170 | With ready mixed red oxide zinc chromate primer Of approved brand and manufacture on steel galvanised iron/ steel works |
| 171 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, including scaffolding: |
| 172 | Providing corrugated galvanised Iron sheet roofing of TATA SHAKTEE / SAIL including fitting and fixing necessary galvanised J or L hooks, bolts and nuts 8 mm dia with bitumen washer 25 mm dia x 3 mm thick and 1.6 mm thick limpet washer complete excluding cost of roof truss, purlin etc. |
| 173 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts,nuts and washers, etc., including making necessary connections with rain water pipes complete |
| 174 | Providing ridges or hips Of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. |
| 175 | Extra for carriage including loading and unloading and all charges complete beyond the initial lead of 5 Km. |
| 176 | Boulders |
| 177 | Stone Aggregates |
| 178 | Cement |
| 179 | Steel |
| 180 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings with one step cpvc solvent cement,trenching,refilling and testing of joints complete |
| 181 | 100 mm |
| 182 | 75 mm |
| 183 | 50 mm |
| 184 | 32 mm |
| 185 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 in spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 186 | 25mm nominal dia pipes |
| 187 | Supplying,fitting and fixing soil waste and vent pipes |
| 188 | Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete with sand cast iron S&S as per IS:1729/IS: 3989 |
| 189 | Supplying fitting and fixing complete single phase open well submersible pumps sets or similar. 2HP |
| 190 | POLYETHYLENE WATER TANK |
| 191 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ls:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 192 | 2000litre capacity |
| 193 | 5000litre capacity |
| 194 | SANITARY FITTINGS (Rate as per Jaquar Costumer Guide Vol 19.2 Catalogue 2024) |
| 195 | Wash basin for Toilet |
| 196 | JDS-BLM-25907N Thin Rim Table top Basin.530 x 420 x 140mm |
| 197 | ALD-727L130 Click Clack Waste coupling 32mm size Full Thread with130mm height |
| 198 | ALD-769L300X190 Bottle trap 32mm Size with 300mm & 190mm long wall connection pipes & wall flange. |
| 199 | FLP-5191PM 3-Hole Basin Mixer with Popup Waste System |
| 200 | FLP-5021PM Pillar Cock with Extension Body |
| 201 | FLP-5053PM Angular Stop Cock with Wall Flange |
| 202 | FLP-5037PM Bib Cock with Wall Flange |
| 203 | AKP-35795 Swivel Mirror 630 x 445mm Rectangular Shape |
| 204 | ACN-1137N Soap dispenser with Metallic bottle |
| 205 | Hand Dryer- Flash HDR-SSF-AK2807 Flash touch-free inframed hand dryer with 1150W rated power 7 carbon brush motor. |
| 206 | AKP-35711PS Single Towel Rail 600mm Long, Stainless Steel |
| 207 | AKP-35721P Towel Ring Square |
| 208 | AHS-1553 Paper Holder with Flap Recessed Type (Stainless Steel) |
| 209 | Water closet for S type |
| 210 | SLS-WHT-6953BIUFSMRimless, Blind Installation Wall Hung WC With UF Soft Close Slim Seat Cover, Hinges And Accessories Set,Size: 375x520x400 mm |
| 211 | JCS-WHT-2431S Single Piece Concealed Cistern Body (Front or Top Actuation) with Installation Kit & “S-Type”drain pipe connection set forWall Hung WC (without FlushControl Plate) |
| 212 | JCP-CHR-152415 Control Plate Opal |
| 213 | Water closet for P type |
| 214 | SLS-WHT-6953BIUFSMRimless, Blind Installation Wall Hung WC With UF Soft Close Slim Seat Cover, Hinges And Accessories Set,Size: 375x520x400 mm |
| 215 | JCS-WHT-2431P Single Piece Concealed Cistern Body (Front or Top Actuation) with Installation Kit & “P-Type”drain pipe connection set for Wall Hung WC (without Flush Control Plate) |
| 216 | JCP-CHR-152415 Control Plate Opal |
| 217 | ALD-577 Hand Shower (Health Faucet) with 8mm Dia, 1 Meter Long Flexible Tube & Wall Hook with N.R.V (Back Flow Preventer) |
| 218 | URS-WHT-13255 Urinals without sensor with fixing Accessories Size: 480 x 300 x 740 mm |
| 219 | SNR-51097 Sensor Flushing Valve for Urinal with Complete Kit (Battery Operated) |
| 220 | Model no: 1810-UC/1110UC, JSE-CHR-110UC450OX Curved shaped urinals partition with frosted glass 10mm , Chrome finish. |
| 221 | SHP-BLK-ST86112 Shower panels GLASSY-BLACK 1400x 250mm |
| 222 | Shower drain channel-Tile insert-Square Item code: 16-0205-05 (102 x 102)mm |
| 223 | Shower drain channel-Tile insert Item code: 16-0203-16 (450 x 125 x 30)mm |
| 224 | FLP-5165PM Single Lever Sink Mixer with Swinging Spout on Upper Side (Wall Mounted Model) with Connecting Legs & Wall Flanges |
| 225 | ERD-WHT-VO25 ERICA VERTICAL (Digital) 25Litres |
| 226 | PHYSICALLY CHALLEGED TOILET |
| 227 | WAC-SAP-BR0600CS Grab bar 692mm Long, Satin |
| 228 | WAC-SAP-BG0800CS Grab bar Vertical Swing, Satin |
| 229 | WAC-SAP-BAI090CS Grab bar Left 90° Angle,Satin |
| 230 | DIS-WHT-93801 Wall Hung Basin with Fixing Accessories, Size :650x565x155 mm |
| 231 | DIS-WHT-93753P180UFRimless Bowl For Coupled WC with UF Soft Close Seat Cover, Hinges, Fixing Accessories, Size:390x610x800mm P-Trap- 180 mm |
| 232 | DIS-WHT-93201 Cistern With Dual Flush Cistern Fitting |
| 233 | Providing and fixing Multi floor trap @320/ per piece inclusive of GST @18% for 4'' in Bathroom and Toilets, complete and as directed. |
| 234 | KRISTALL TREND,BKT-CHR-31651200X : Corner entry shower enclosure with door sliding to both sides - 4 parts Glass: 6mm Finish: Chrome (H: 1850 W: 1200 X 1200)mm |
| 235 | ESA-GBL-LDG1212 Artificial Marble Ledge 1200 x 1200mm |
| 236 | Model No. 1810-D/ 1110-D: Wall to wall shower Enclosure only door with towel rod & handel -1 part H: 1950 W:801-1000 |
| 237 | GALAXY BLACK ESA-GBL-LDG0812 Artificial Marble Ledge 801 - 1200mm |
| 238 | Double Bowl Exclusive Size: 1139 x 498 x 245mm (Black) 13-0312-02 |
| 239 | INTERNAL PIPELINE (Rate as per Market Rate) |
| 240 | PVC pipe for Soil pipe, Waste pipe and Urinals Pipe |
| 241 | 110mm dia. (Soil pipe) |
| 242 | 75mm dia (Waste pipe) |
| 243 | 50 mm dia (Waste pipe) |
| 244 | 90 Degree PVC bend |
| 245 | 110 mm dia |
| 246 | 75 mm dia. |
| 247 | 50 mm dia. |
| 248 | 90 Degree PVC bend with Doors |
| 249 | 110 mm dia |
| 250 | 75 mm dia. |
| 251 | 50 mm dia. |
| 252 | 45 Degree PVC bend |
| 253 | 110 mm dia |
| 254 | 75 mm dia. |
| 255 | 50 mm dia. |
| 256 | PVC single ‘Y’ |
| 257 | 110 mm dia |
| 258 | 75 mm dia. |
| 259 | 50 mm dia. |
| 260 | PVC coupler |
| 261 | 110 mm dia |
| 262 | 75 mm dia. |
| 263 | 50 mm dia. |
| 264 | PVC cleaning pipe |
| 265 | 110 mm dia |
| 266 | 75 mm dia. |
| 267 | PVC End Cap |
| 268 | 110 mm dia |
| 269 | 75 mm dia. |
| 270 | PVC cowl |
| 271 | 110 mm dia PVC cowl |
| 272 | 75 mm dia PVC cowl |
| 273 | SWIMMING POOL |
| 274 | MAIN POOL |
| 275 | Filters |
| 276 | Fiberglass reinforced tank and swing away water diffuser with top Mountmultiport valve (700 mm 'dia') |
| 277 | Make: Pentair USA |
| 278 | Recirculation pump |
| 279 | Self Priming pumps.Pump body and prefilter in cast iron Motorshafts instainless steel AISI-304, impeller in HT200, mechanical seal in graphite.with motor -2900 rpm, 1.1 kw, 220-380V, 1.5HP, protection IP-55 and insulation class-F. |
| 280 | Make: Pentair USA |
| 281 | WATER TREATMENTS |
| 282 | Dosing Pump |
| 283 | CHLOR #320 1PK |
| 284 | Make: Lyxar |
| 285 | POOL BASIN ITEMS |
| 286 | Main Drain |
| 287 | Wall inlet 2\\" slipwith 1.5\\" slip bushing white |
| 288 | Make: Pentair USA |
| 289 | Wall Inlet |
| 290 | Wall inlet 2\\" slipwith 1.5\\" slip bushing white |
| 291 | Make: Pentair USA |
| 292 | Suction Inlets ( Vacuum points) |
| 293 | Vacuum fitting in white ABS with 50/2 threaded. |
| 294 | Make: Pentair USA |
| 295 | Ladder |
| 296 | Standard Ladder 3 Steps AISI 304 |
| 297 | Ladder |
| 298 | Standard Ladder 4 Steps AISI 304 |
| 299 | POOL SIDE EQUIPMENTS |
| 300 | Skimmer |
| 301 | Make: Pentair USA |
| 302 | UNDERWATER ILLUMINATION |
| 303 | Underwater Lights |
| 304 | Surface Mounted Light 441 leds warm white 20W/12V |
| 305 | Make: Lyzar |
| 306 | Transformer for lights |
| 307 | Power: 400w |
| 308 | SWIMMING POOL MAINTENANCE ACESSORIES |
| 309 | Telescopic Handle |
| 310 | 2X240 cm Ribbed pole - 1.1mm thick |
| 311 | Make: Pentair USA |
| 312 | Hose Pipe (Floting Hose) |
| 313 | Extruded PE. ∮1 1/2\\" - 15M |
| 314 | Make: Pentair USA |
| 315 | Vaccum Head |
| 316 | Make: Pentair USA |
| 317 | Shallow Net |
| 318 | Aluminum leaf skimmer (blue anodized handle) |
| 319 | Make: Pentair USA |
| 320 | Deep Net |
| 321 | Aluminum frame deep rake(Bule anodized handle) |
| 322 | Make: Pentair USA |
| 323 | Brush |
| 324 | 18\\"/45cm standard curved polybristle wall brush |
| 325 | Make: Pentair USA |
| 326 | Test Kit |
| 327 | Basic PH &CL test kit |
| 328 | Make: Pentair USA |
| 329 | Pool Plumbing |
| 330 | Providing all necessary plumbing using u-PVC Schedule 40 pressure Pipes with plain socket suitable for solvent cement jointing conforming toIS:4985/2000 & fittings conforming to IS 7834/87. Cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc.The plumbing installation shall be tested to a pressure of 10 Kg/Sq.cm. for a period of 4 hours before covering with mortar. The rate includes all uPVC ball valves and non return valves as required and directed by the consultant. The pipe line will supported by proper MS support (duly pianted ) in the plant room and encased in concrete when underground. (All civil work support will be provided by the clinet). |
| 331 | Make: Paras/Astral/Equiv. |
| 332 | ELECTRICAL CONTROL PANEL and Wiring |
| 333 | Design, Manufacture, Supply, of Control panel constructed out of 1.5 - 2mm thick MS sheet steel fabricated cubicle type panel & panel degree of protection IP 41. The panel shall be complete incoming MCCB/ MCB, suitable size link complete with VAF digital electronic meter and 50/5 Amps suitable VA, CT's. set & complete with direct on line starter/ star delta starter, automatic/manual mode selection switch & earthing connector etc as required. whisch is sutable for pumps 4hp three phase380/440 VAC 50 hz. |
| 334 | Make: Polycab/Havels/Equiv. |
| 335 | Glass Mossiac Tiles |
| 336 | Size: 20x20mm |
| 337 | Rate Inclusive of materials and labour Item Rate BoQ BoQ_Ver4.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Directorate of Tourism Name of Work DEVELOPMENT OF TOURISM FACILITIES AT WAHKALIAR(Overlooking Nohkalikai), SOHRA, MEGHALAYA Contract No: Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 338 | INTERNAL WORK |
| 339 | Concealed wiring in looping system with 2x1.5 mm² PVC insulated single core cable of 600V grade in heavyguage PVC pipe including occuping and fitting of elbows, bends, fees, junction box etc. including requird size of MS Conceal boxes and front plate for housing of switches socketsfan regulator bell push etc complete to light point. |
| 340 | (a) Long Point upto 10 mtr |
| 341 | (b) Medium Point upto 6 mtr |
| 342 | (c) Short Point upto 3 mtr |
| 343 | Wiring as in item no.20 above to light plug point when fixed elsewhere with continous earth wire complete. |
| 344 | (a) Long Point upto 10 mtr |
| 345 | (b) Medium Point upto 6 mtr |
| 346 | (c) Short Point upto 3 mtr |
| 347 | Wiring as in item No.1 complete to a light plug point when fixed on the same board. |
| 348 | Wiring as in item No.20 above to a Power Plug Point with 2x4 mm² including supplying and fitting of 15 Amp modular switch socket combined with continous earth wire to a Power Plug Point Complete |
| 349 | (a) Long Point upto 10 mtr |
| 350 | (b) Medium Point upto 6 mtr |
| 351 | (c) Short Point upto 3 mtr |
| 352 | Wiring as in item No.20 above to a ceiling Fan/Exhaust Fan point. |
| 353 | (a) Long Point upto 10 mtr |
| 354 | (b) Medium Point upto 6 mtr |
| 355 | (c) Short Point upto 3 mtr |
| 356 | Wiring as in item No.20 above to calling Bell/Bell Indicator point. |
| 357 | (a) Long Point upto 10 mtr |
| 358 | (b) Medium Point upto 6 mtr |
| 359 | Wiring as in item No.20 above for Staircase/ 2 Way Switch wiring. |
| 360 | (a) Long Point upto 10 mtr |
| 361 | (b) Medium Point upto 6 mtr |
| 362 | Drawing of Main and Sub-Main Line wiring as inn item No.20 above with VIR or PVC Single Core 250V Grade Cable. |
| 363 | (a) With 2x2.5 mm² copper wire |
| 364 | (b) With 2x4 mm² copper wire |
| 365 | Drawing 3 phase Main Line 4 wire with DGSD approved VIR or PVC cable 660 V grade in Heavy Guage 16 SWG Regid pipe Including with all necessary accessories. |
| 366 | (c) With 4x6 mm² copper wire |
| 367 | (d) With 4x10 mm² copper wire |
| 368 | Supplying, fitting & fixing complete 240/415 V Al. Bus-Bar chamber. |
| 369 | A. Economy Sheet Steel 50Hz. 240/415 V. |
| 370 | (ii) TPN 4 Ways. |
| 371 | (c) 100 Amp 415 V Capacity. |
| 372 | Supplying & fixing of Load Kontaket Miniature Circuit Breakers DX3 MCB's for AC application till 63 A |
| 373 | A. Single Pole 240/410 V |
| 374 | (a) 0.5-6 Amp |
| 375 | (b) 6-32 Amp |
| 376 | Supplying, fitting & fixing of DX3 Isolators for AC applications upto 125 A. |
| 377 | C. Four Pole 415 V |
| 378 | (b) 40 Amp |
| 379 | Supplying, fitting and fixing of Moulded Case Circuit Breaker (MCCB's) of the following Amp capacity. |
| 380 | B. With breaking capcity of 20 kA |
| 381 | (iii) Four Poles |
| 382 | (b) 80-100 Amp |
| 383 | Supplying, fitting & fixing if Distribution Board ETPN DB's for MCB, Isolator, RCCB and RCBO. |
| 384 | B. IP 43-#1K 09 with metal door |
| 385 | (b) 6 way 8+18 Module |
| 386 | (c) 8 way 8+24 Module |
| 387 | Supplying, fitting and fixing of LED Batten surface or wall mounted with all necessary accssories. |
| 388 | (b) With Aluminium housing & integrated electronic driver. |
| 389 | (ii) 18 w (1182x23x37) mm |
| 390 | Supplying, fitting and fixing of LED PANEL LIGHTING surface or wall mounted with all necessary accessories. |
| 391 | (a) 2x2 (595x595x65) mm LED luminarie. |
| 392 | (i) 18 W |
| 393 | (ii) 24 W |
| 394 | Supplying, fitting and fixing of LED DOWNLIGHTS surface or wall mounted with all necessary accessories. |
| 395 | (b) Recess mounted pressure die-cast aluminium luminaire in powder coated whited finish with drop down PC diffuser with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver. |
| 396 | (i) 5 W ceiling cutout:ø 155 mm, height: 45 mm |
| 397 | Supplying, fitting and fixing of LED MIRROR LIGHT surface or wall mounted with all necessary. |
| 398 | Supply, Installation, Testing & Commissioning of 1x9 watt LED Mirror light fixture wall mounted with electronic high efficiency electronic driver as complete as required. (Phillips Make, Cat No-31083 shell or equivalent) |
| 399 | (a) LED Mirror Lights. |
| 400 | Supplying, fitting and fixing of LANDSCAPE LIGHTS surface or wall mounted with all necessary accessories. |
| 401 | (b) Family of post top lantern designed to complement the geometry of the area (design from the renaissance era yet with a modern look using new generation technology in LED). |
| 402 | (ii) 50 W suitable for pole dia ø 76 mm |
| 403 | (f) Decorative UP-down luminaire with wall surface mounting using COB LED as light source. |
| 404 | (i) 15 w |
| 405 | (h) Aesthetically designed die-cast aluminium landscape luminaire for downward lighting with high power LED as light source. |
| 406 | (i) 16 w (for Bollards) |
| 407 | Supplying, fitting, connecting, testing and commissioning of calling Bell/Bell Indicator type suitable for 230 V as well as battery operated complete with all necessary accessories. |
| 408 | (a) Dingdong Bell |
| 409 | Supplying, fitting & fixing of exhaust fan double self lubricating type single phase 50Hz 250V AC operated complete with supporting frame, fan blades, nuts and bolts and other petty accessories as required. |
| 410 | (a) Domestic Exhaust Fans |
| 411 | (i) 150 mm |
| 412 | Providing, laying, connection, testing & commissioning of the following sizes of 1100 V PVC/XLPE Armoured Cables with Alluminium conductor as per ISI code in bracket, trenches sand cushioning with laying etc and refilling the same in layers or by supporting them in walls and all other accessories as required. |
| 413 | (d) With 3.5 core 70 mm² . |
| 414 | Supplying, fitting and fixing of Copper lightning Arrester with 5 nos. Finger at the top & copper base plate at the bottom. |
| 415 | (b) with 5ft high copper rod. |
| 416 | Supplying, fitting & fixing earthing with copper earth plate 600x600x6 mm thick including accessories & providing masonry enclosure with cover plate having locking arrangement & watering pipe etc with charcoal, salt etc complete as required. |
| 417 | (a) Copper earth plate electrode. |
| 418 | Supplying and laying of 15 mm x 5 mm GI/Copper Strip at 0.50 mtrs, below ground. |
| 419 | (a) with 25 mm x 5 copper strip. |
| 420 | Supplying, fitting and fixing of 440 Volt grade Four pole change over Main Switch (Best Quality) |
| 421 | 100 Amp capcity. |
| 422 | Concealed wiring in looping system with 2x1.5 mm² PVC insulated single core cable of 600V grade in heavyguage PVC pipe including occuping and fitting of elbows, bends, fees, junction box etc. including requird size of MS Conceal boxes and front plate for housing of switches socketsfan regulator bell push etc complete to light point. |
| 423 | (a) Long Point upto 10 mtr |
| 424 | Drawing of Main and Sub-Main Line wiring as inn item No.20 above with VIR or PVC Single Core 250V Grade Cable. |
| 425 | (b) With 2x4 mm² copper wire |
| 426 | Supplying & fixing of Load Kontaket Miniature Circuit Breakers DX3 MCB's for AC application till 63 A |
| 427 | A. Single Pole 240/410 V |
| 428 | (a) 0.5-6 Amp |
| 429 | (b) 6-32 Amp |
| 430 | Supplying, fitting & fixing of DX3 Isolators for AC applications upto 125 A. |
| 431 | A. Double Pole 240 V |
| 432 | (b) 40 Amp |
| 433 | Supplying, fitting & fixing if Distribution Board SPN DB's for MCB, Isolator, RCCB and RCBO. |
| 434 | B. IP 43-#1K 09 with metal door |
| 435 | (c) 12 way + 12 Module |
| 436 | Supplying, fitting and fixing of LANDSCAPE LIGHTS surface or wall mounted with all necessary accessories. |
| 437 | (b) Family of post top lantern designed to complement the geometry of the area (design from the renaissance era yet with a modern look using new generation technology in LED). |
| 438 | (ii) 50 W suitable for pole dia ø 76 mm |
| 439 | Providing, laying, connection, testing & commissioning of the following sizes of 1100 V PVC/XLPE Armoured Cables with Alluminium conductor as per ISI code in bracket, trenches sand cushioning with laying etc and refilling the same in layers or by supporting them in walls and all other accessories as required. |
| 440 | (a) With 3.5 core 25 mm² . |
| 441 | (b) with 5ft high copper rod. |
| 442 | ELEVATOR SPECIFICATIONS |
| 443 | CAPACITY (kgs): 6 persons |
| 444 | SPEED (mps): 0.7 mps |
| 445 | RISE (m): 12.7m |
| 446 | STOPS :5 stops with opening on the same side |
| 447 | DRIVE: VVVF Regeneration (Closed loop) |
| 448 | POWER SUPPLY: 400/415 Volts (3 phase AC) |
| 449 | OPERATION: Full collective operation |
| 450 | CAR GROUP: One Car (Simplex) |
| 451 | MACHINE: PM Gearless (Located in shaft on top of guide rails) |
| 452 | TRACTION MEDIA: Flat coated steel belt |
| 453 | CAR FINISH: Stainless Steel - Hairline finish |
| 454 | FALSE CEILING FINISH: Stainless steel #4 (hairline) |
| 455 | VENTILATION: Cross flow fan |
| 456 | HAND RAILS: handrails on rear car panels |
| 457 | FLOORING: Vinyl |
| 458 | CAR DOOR FINISH: Stainless steel #4 (hairline) |
| 459 | LANDING DOOR FINISH: Stainless steel #4 (hairline) |
| 460 | FIRE RATED DOORS: Fire rating - 60mins |
| 461 | PIT DEPTH: 1350 |
| 462 | OVERHEAD: 4500 |
| 463 | HOISTWAY DIMENSIONS (W x D)mm: 1600mm W x 1400mm D |
| 464 | CAR DIMENSIONS (W x D x H)mm: 1000mm W x 1100mm D x 2100mm D |
| 465 | CAR & HOISTWAY DOOR TYPE: Central opening (CO) doors. |
| 466 | DOOR OPENING(W x H x - mm): 700 mmW x 2000 mm H |
| 467 | DOOR OPERATOR: DC Door Operator |
| 468 | COP: Black Titanium Hairline |
| 469 | CAR POSITION INDICATOR: 7Segment |
| 470 | HALL FIXTURES |
| 471 | HALL FIXTURES FACE PLATE: SS Hairline |
| 472 | HALL BUTTON ARRANGEMENT:Hall Botton with HPI |
| 473 | STANARD FEATURES : Anti Nuisance Car Call Protection |
| 474 | Overload Device |
| 475 | Nudging |
| 476 | Grounding Switch |
| 477 | Emergency Car Light Unit |
| 478 | Infrated Curtain Door Protection |
| 479 | Door Time Protection |
| 480 | Emergency Alarm Button |
| 481 | Extra Door Time of Lobby & Parking |
| 482 | Door Open / Close Button |
| 483 | Manual Rescue Operation |
| 484 | Belt Inspection Drive |
| 485 | Auto Fan Cut Off |
| 486 | Automatic Rescue Operation |
| 487 | OPTIONS INCLUDES: Automatic Rescue Operation Total in Figures 0.0 0.0 Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only ESMP Cost |
| 488 | Airt Quality Monitoring |
| 489 | Water Quality Monitoring |
| 490 | Noise Levels Monitoring |
| 491 | SOLID WASTE, Demolition wastes and scrapdisposal as per C & D rules 2016 |
| 492 | Dust settling and removal of water after rains:Provision for dust settling measures including water spraying and installation of dust screens around the site. |
| 493 | 8 drinking water purifiers (4 each at construction site andconstruction camps)100 LPH RO + UVwater filter- |
| 494 | Doctor’s visit to Construction Camp every fortnight forchecking of basic health of the workers. |
| 495 | Provision for helmet, gumboots, jackets, goggles, N95masks, Sanitisers, etc. to labourers. Lump sum |
| 496 | Bio Toilets in Construction CampSupply of D.R.D.O Technology Bio-Digester tanks Rotamoldeddouble wall manufactured in automatic Rotamoldingmachines using superior grade Virgin LLDPE(Polymer) with 2.5% Carbon Black, UV Resistant Polymerleading to highest quality consistency. Thickness of theouter shell of minimum 6mm, partitions made from HDPEPolymer of 8mm thick. Immobilization Matrices of HeavyDuty Poly Grass PVC Matting lining along the partitions onboth sides. Heavy duty pipes & fitting shall be used in these tanks of Finolex or equivalent make. Fasteners made ofBrass shall be used inside the tank with manufacturer’s testcertificate and including AMI (Bacteria) of 600 liters pertank.Size of Tank: 2000 Litres capacity upto 20-30 users per day;Tank Diameter of 1425mm; Tank Height of 1600mm;Outlet pipe diameter 75mm; inlet pipe diameter 110mm. |
| 497 | FRP Toilet Cabin IWC (Ceramic Pan) type of size 1250mm X 915mm X 2400mm with ± 5% tolerance. |
| 498 | Plumber(Skilled) |
| 499 | Plumber(unskilled) |
| 500 | Drinking water 250 LPH RO Plant |
| 501 | Provision of Hoarding /Posters at construction camps and provision of health checks at construction sites |
| 502 | Periodic visit by a qualified medical doctor (PHC/CHC/SDH etc.) to the campsite for health check-up of workers, at leastonce in 15 days. nt |
| 503 | Provision for helmet, gumboots, jackets, goggles, etc. to labourers Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy