| 1 | Dismantling tile/ Kota stone/ Marble / Granite work in floors/walls and roofs laid in cement mortar including stacking material within 50 metres lead. 15.11.1 For thickness of tiles 10 mm to 25 mm. |
| 2 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. 15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). |
| 3 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 4 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 15.14.1 Of area 3 sq. metres and below. |
| 5 | Supplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding 20cm in depth and dressing complete. Note: - Maximum thickness of this layer shall be 20 cm. |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : 4.1.2 With 40mm nominal size graded stone aggregate. 4.1.2.2 M 10 |
| 7 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 sand) |
| 8 | 12 mm cement plaster of mix: 13.1.2 1:6 (1 cement : 6 sand) |
| 9 | 15 mm cement plaster on rough side of single or half brick wall of mix : 13.2.2 1:6 (1 cement: 6 sand) |
| 10 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 11 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 12 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq.metres and under including cutting the patch in proper shape, raking out joinjts and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 metres lead : 14.1.1 With cement mortar 1:4 (1 cement : 4 sand) |
| 13 | Steel work in built up tubular trusses/frame. Steel work in built up M.S. tubular section (round, square or rectangular hollow tubes etc.) trusses/frame work etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.14.1 Hot finished welded type tubes |
| 14 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 15 | Providing and laying vitrified floor tiles (without soluble salt) or printed (with soluble salt) Nano polished (Glossy finish) in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours & shades, 1st quality/ premium quality in flooring laid on 20mm thick cement mortar 1:4 (1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11.76.1 Plain ivory light shade. Size 600X600mm thickness 9-10mm |
| 16 | Providing and fixing Ceramic glazed wall tiles 300x450 mm or more (having thickness 6 to 7 mm) of 1st quality conforming to IS: 15622 of approved make in all Colours& shades, except burgundy, bottle green, black laid on 12mm thick bed of Cement Mortar 1:3 (1 Cement: 3 sand)preprad same day when mortar is still green jointed with grey cement slurry @3.3 kg per sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 17 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc. of required colour strength, thickness pattern, surface texture (smooth/rough) and size/shape, conforming to 15658-2006 made by table vibratory method using PU mould, laid in required colour and pattern over 50mm thick compacted bed of sand, compacting and proper embedding/ laying of inter locking paver blocks into the bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand including locking with M15 cement concrete in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturer's specifications and direction of Engineer-in- Charge. 11.72.1 80 mm thick C.C. paver block of M-35 grade. |
| 18 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 21.1.1 For fixed portion. 21.1.1.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 19 | Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side having 12 mm air gap including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in- Charge complete. |
| 20 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.63 mm all complete. 9.46.1 With 2nd class teak wood beading 62x19 mm. |
| 21 | Providing and fixing bright finished brass handles with necessary screws etc. complete. 9.81.1 125 mm |
| 22 | Providing and fixing bright finished brass sliding door bolts with nuts and screws etc complete. 9.82.1 300x16mm |
| 23 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 9.79.3 200x10 mm |
| 24 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : 17.11.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. |
| 25 | Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. 17.58.1 75 mm diameter (minimum wall thickness 3.2mm) |
| 26 | 17.58.2 110 mm diameter |
| 27 | Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 17.59.1 Coupler. 17.59.1.1 75 mm |
| 28 | 17.59.1.2 110 mm |
| 29 | Constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20m long complete as per standard design. |
| 30 | Providing and fixing brass bib cock of approved quality. 18.29.1 15 mm nominal bore |
| 31 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in- Charge. 18.6.1 Internal work - Exposed on wall. 18.6.1.1 15 mm nominal outer dia. Pipes. |
| 32 | 18.6.1.2 20 mm nominal outer dia. Pipes. |
| 33 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern and C.P. flush bend with fittings and C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid. |
| 34 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete. Note : Putty shall be applied only on the internal walls, for application on the exterior walls prior permission of Chief Engineer will be required. |
| 35 | Wall painting by any mechanical or manual means with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade. |
| 36 | Finishing walls by only mechanical or manual means with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm. |
| 37 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 38 | Grading roof for receiving water proofing treatment with. 22.14.2 Cement mortar 1:3 (1 cement : 3 sand) |
| 39 | Boundary Wall :- Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 20.3.1 300 mm dia piles. |
| 40 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : 4.1.1 With 20mm nominal size graded stone aggregate. 4.1.1.2 M 15 |
| 41 | Centering and shuttering including strutting, propping etc. and removal of form work for : 4.3.1 Upto plinth: Foundations, footings, bases for columns, plinth beams, curtain walls, columns below plinth. |
| 42 | 4.3.2 above plinth: Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, and string courses fillets etc. |
| 43 | Brick work with well burnt chimney bricks in bulls pattern trench kiln, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level i/c curing etc complete. 6.4.2 Cement Mortar 1:6 (1 cement:6 sand). |
| 44 | 12 mm cement plaster of mix: 13.1.2 1:6 (1 cement : 6 sand) |
| 45 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing) etc. complete. (Note:- 1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge. 2. No extra payment shall be done for overlaps and/or couplers. 3. Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”). 5.16.3 Cold twisted bars (CTD) |
| 46 | Structural steel work using M.S. flats, angles, channels I-section, H-section etc. riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 47 | Supplying and filling in plinth under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete. 2.27.1 With hard muram having CBR >12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm) |
| 48 | Colour washing such as green, blue or buff to give an even shade: New work (two or more coats) with a base coat of white washing with lime. |
| 49 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. Please Enable Macros to View BoQ information |