| 1 | Attending of complaint by covering the following items of work :-(a) Cleaning and clearing of blocked IWCs and EWCs to sewage line upto 1st manholes by rodding or any other suitable method and taking out the muck, mud and other debris from WCs and the sewage line cleaning with fresh water & removing the debris upto a distance exceeding 200M and not exceeding 250M and covering the same with a layer of soil not less than 15cm thick complete all as specified and as directed by Engr-in-Charge.(b) Cleaning and clearing of blocked chocked floor trap in kitchen and bathrooms including gully trap, the waste water line connection etc by rodding or by any other suitable method and taking out the debris to a distance exceeding 200m & not exceeding 250m and covering the same with a layer of soil not less than 15cm thick and drain out the floors taps, gully traps waste pipe and soil pipe with fresh water etc complete all as specified and as directed.Note:-(i) Adequate number of workmen shall be deployed as and when complain received for immediate execution. If any complaint not attend by the contractor within a day then a sum of Rs. 500.00 will be recovered against per complain per day from the contractor.(ii) Rate quoted above shall be deemed to including the cost of adequate T&P, equipment, safety devices etc(iii) Proper records (date wise) of complaints received & rectified by the contractor and attendance register of trademen shall be maintained and shall be produced for verification at the time of payment of each RAR/Bill. |
| 2 | Taking out liquid/solid content from manhole/ sump/ septic tank of any size any depth by super succer machine or high pressure pump, cleaning throughly including disposal of liquid/solid content out of the Cantt Area and covering with a layer of soil not less than 15cm thick complete all as specified and directed. |
| 3 | M&L for cleaning of Sewage line of 100mm bore from gully traps, grease traps etc. upto 1.5 m deep by removing all filtn/silt, foreign materials and other deposits whatsoever completely and making the line free from all obstacles and testing the flow of sewer line evenly, smoothly by filling water. The cleaning operation will be carried out in suitable lengths by blocking the first and last manholes of sewage line and removing the silt/sludge & other deposits out side of MD land in covered van/trolley,complete all as specified and directed. |
| 4 | All as per serial item No -3 above but sewage line of 150 mm bore and depth of sewage line upto 1.50 m complete all as specified and directed. |
| 5 | All as per serial item No -3 above but sewage line of 150 mm bore and depth of sewage line exc1.50 m and n exc 3.00 m complete all as specified and directed. |
| 6 | All as per serial item No -3 here-in-above but sewage line of 200 mm to 250 mm bore and depth of sewage line exc 1.5m and n exc 3.00 m complete all as specified and directed. |
| 7 | All as per serial item No -3 here-in-above but sewage line of 200 mm to 250 mm bore and depth of sewage line exc 3.00m and n exc 4.50 m complete all as specified and directed. |
| 8 | M&L for Cleaning of manholes depth upto 1.5 mtr by removing all silt, sludge, any other materials making clean and flushing with water complete incuding removal of spoils out side MD land and taken out cover slab and reset in the same position after cleaning and testing all as specified and directed. cleaning shall be done either manually or mechanically as required and directed by Engr-in-charge. |
| 9 | All as per serial item No 8 above but depth exceeding 1.5 m and not exc 3 m deep complete all as specified and directed. |
| 10 | All as per serial item No 8 above but depth exceeding 3.00 m and not exc 4.5 m deep complete all as specified and directed. |
| 11 | Demolition of brick work or stone/boulder masonary, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed. |
| 12 | M&L for brick work with sub class 'B' bricks well burnt straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 13 | Taking down cement plaster plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 14 | M&L for 15 mm thick rendering in CM (1:4) in two layers (10 + 5mm) mixed with approved water proofing compound @ 3% by weight of cement in second layer or as per direction of manufacturer on fair faces of brick work including finished even and smooth without using extra cement complete all as specified and directed.Note : WPC shall ve and paid separately as supply only |
| 15 | Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15cm thick (below or above ground level) complete all as specified and directed |
| 16 | Demolition of reinforcement cement Concrete of any description and in any position (reinforcement cut as required to facilitte demolition) complete all as specified and directed. |
| 17 | M&L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate in foundations, filling and mass concrete complete all as specified and directed. |
| 18 | M&L for PCC 1:2:4 type B1 using 20mm graded stone aggragate as in bed blocks, bed plates, coping etc including weathering slightly rounded or chamfered angles and throating making groves for fixing of man hole cover including necessary form work complete all as specified and directed. |
| 19 | M&L for precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including placing in position and set in CM (1:6) complete all as specified and directed.Note :- Reinforcement shall be measured and paid for separately. |
| 20 | M&L for cement concrete (1:3:6) type C2 using 40 mm graded crushed stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement incl form work. |
| 21 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed. |
| 22 | M&L for reinforcement TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 23 | S&F Mild steel Framed work such as grills, gratings, etc using angle Iron ,flat Iron ,round bars with end of bars shouldered and or rivetted or forged into spikes ,framed guard bars barred into iron doors ,walkways railing framework amd similler work confiming to Fe 290 ,GDE E-165 all as specified and directed. |
| 24 | M&L for cement concrete 75mm thick 1:2:4 type B-2 using 40mm graded stone aggregate as in pathways/hardstanding laid in alternate ways, each panel not exceeding 3.00 Sqm finished the surface even and fair without using extra cement and joint to be filled with Bituminous mastic filling including necessary form work complete all as specified & directed. |
| 25 | M&L for cement concrete 100mm thick 1:2:4 type B-2 using 40mm graded stone aggregate as in pathways/hardstanding/berms etc, laid in alternate ways, each panel not exceeding 3.00 Sqm finished the surface even and fair without using extra cement and joint to be filled with Bituminous mastic filling including necessary form work complete all as specified and directed. |
| 26 | M&L for 75 mm thick plain cement concrete 1:3:6, type c-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement including making joints with bitumastic filling in proportion of bitumen and sand (1:2) complete all as specified and directed. |
| 27 | M&L for forming Construction joint 30mm deep x 10mm wide filled with sealing compound, Grade ‘A’ complete all as specified and directed. |
| 28 | S&F in repairs as for Gun metal gate valves with iron wheel headscrewed both ends for iron pipes or for unions for 20 mm bore pipes, fixed complete all as specified and directed. |
| 29 | S&F in repairs, 20 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe (Minimum weight / 20mm-210) and fixed complete all as specified and directed. |
| 30 | S&F in repairs salt glazed stone ware gully trap square or round mouthed type 'P' of size 150 x 150 mm with CI grating, setting & jointing with cement with grouting surrounding gully trap with PCC 1:3:6, type C1 block 30x30x45cm together with necessary form work, excavation & earth work in soft/loose soil, complete, all as specified and directed. |
| 31 | S&F in repairs for MS grating CP 75/100mm dia, with hole for waste pipe of approved make including fixing with CM to floor/nahani traps etc complete all as specified and directed. |
| 32 | S&F in repairs, 15mm bore, PVC connection pipe 600mm long with PTMT nuts at both ends complete all as specified and directed. |
| 33 | S&F in repair 110 mm stack clamp out of 50mmx 5 mm flat iron and 16 mm dia round iron stays incl bolts and nuts and securing ends of stays to walls or roof etc, complete all as specified and directed. |
| 34 | Taking down chowkats or frame, n. exc 1.5 sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed. |
| 35 | S&F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, suppling & fixing in opening as per specification and drawing complete all as specified and directed. |
| 36 | S&F factory made solid panel PVC door shutter, 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded, plain colour PVC \\"C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement all as per specification and drawing complete all as specified and directed. |
| 37 | S&F 75 mm long butt hinges, medium weight, stainless steel, and fixed complete all as specified and directed. |
| 38 | S&F 125 mm size Aluminium handles, cast type, anodised complete all as specified and directed. |
| 39 | S&F 150 mm long aluminium, anodised barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 40 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises complete all as specified and directed |
| 41 | M&L for 25 mm thick Cement concrete type B-0, 1:2:4 (12.5 mm graded stone aggregate) as in bedding layer of floor finished the surface even and rough complete all as specified and directed. |
| 42 | M&L for coloured Non skid ceramic tiles(Ist quality) 7 to 8mm thick area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm as in floors etc., laid over and including 15 mm thick screed bed of cement & sand mortar 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 43 | M&L for Non skid ceramic tiles 7 to 8mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm 7mm thick coloured tiles in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, over screed bedding 15mm thick in CM 1:4 complete all as specified and directed. |
| 44 | M&L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set thick joint free set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick rendering in Cement& Sand Mortar 1:4 complete all as specified and directed. |
| 45 | S&F (in repairs) vitreous china wash down water closet pan (Padestal pattern), white (ISI marked), including connection to drain (or outgoing pipe) and to flushing pipe, anti-syphonoage pipe etc & with plastic WC seat cover (white) closed pattern with flat bottom and cover and suitable mild steel chromium plated or aluminised hinging device complete all as specified and directed. (Make : Hindware/Cera as approved by GE). |
| 46 | S&F (in repairs) vitreous china squatting pan 'orissa pattern' size 580 x 450 mm white with integral foot rest (ISI marked) with 'P' or 'S' trap, front or back inlet and foot rest any pattern, including connection to flushing pipe anti-syphonage pipe etc, including setting of pan & trap in lean PCC 1:5:10 complete and making good to distrubed floor with PCC or cement mortar 1:3 to match with sorroundings complete all as specified and directed. |
| 47 | &F vitreous china Semi pedestal pattern (Anglo Indian type) white connection to trap 'P' or 'S' and flush pipe etc seat cover and making good to disturbed surfaces of floor by filling with PCC 1:4:8 type D-2 to match with existing including taking down the existing old one complete all as specified and directed. |
| 48 | S&F in repairs vitreous china wash basin white of size 550x400 mm with padestal stand (ISI marked) including 32 mm CP waste coupling & PVC flexible waste pipe of min 90 cm long, flat back or angle back type excluding taps, waste chain & plug but incuding cast iron brackets and cutting for and pinning in ends of brackets or erecting stand complete fixed in repairs complete all as specified and directed. |
| 49 | S&F in repairs PVC low level flushing cistern 10 litrs capacity (white ISI marked) with inlet ball valve, float and handle, syphonic action type including brackets and flush pipe of polythelene of low or high density of PVC 32mm dia for LLFC make Dolfine/Commander Champion, complete all as specified. |
| 50 | S&F in repairs plastic water closet seat cover white closed pattern with flat bottom and mild steel CP or aluminium hinging device complete all as specified and directed. |
| 51 | S & F in repairs for 32mm Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified an directed. |
| 52 | Cleaning of open shaft of bldg including gully trap, cleaning with wire brush incl of grass, roots, bushes etc and taking out accumulated garbage etc, from shaft and removing the same to a distance not exceeding 50 meter, complete all as specified and directed. |
| 53 | Excavation in trenches not exc 1.5m wide and not exc 1.5m deep for foundation or for shafts, walls, manholes etc not exc. 10 Sqm on plan and getting out in soft/loose soil complete all as specified and directed. |
| 54 | All as per serial item No. 53 here-in-above but depth exc 1.5m and not exc 3m complete all as specified and directed. |
| 55 | Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and directed. |
| 56 | Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed. |
| 57 | Demolition and breaking up 150 mm bore drain pipes, salt glazed stone ware set in cement mortar including PCC haunching and bedding, complete all as specified and directed. |
| 58 | Demolition and breaking up 200 mm bore drain pipes, salt glazed stone ware set in cement mortar including PCC haunching and bedding, complete all as specified and directed. |
| 59 | S&F salt glazed stone ware drain pipes of 150mm bore, grade `A’, ISI marked, laid to slope in trenches, jointed in CM (1:1) and tested complete all as specified and directed. |
| 60 | M&L for 150 mm bore reinforced concrete pipe, class NP3, laid and jointed (in CM 1:1) complete with collars all as specified & as directed. |
| 61 | M&L for 200 mm bore reinforced concrete pipe, class NP3, laid and jointed (in CM 1:1) complete with collars complete all as specified and directed. |
| 62 | M&L for PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in bedding to SGSW/NP2 drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested complete for 150 mm bore pipe complete all as specified and directed. |
| 63 | M&L for PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in bedding to SGSW/NP2 pipes, including packing under and haunching against the sides of pipes after they are laid and tested complete for 200 mm bore pipe complete all as specified and directed. |
| 64 | M&L for cutting into existing manholes / Septic tank for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required for 150mm bore pipe complete all as specified and directed. |
| 65 | All as per serial item No. 64 above but for 200 mm bore pipe complete all as specified and directed. |
| 66 | S&F 110mm bore PVC (SWR) pipes class 'B' single socketed in any length with rubber ring joints / solvent cement joints laid in trenches or in floors complete all as specified including dismantling of PCC & taking out old unserviceable 110mm bore PVC pipe with fittings & making good disturbed area ccomplete all as specified and directed. |
| 67 | S&F PVC (SWR) pipe 110mm bore class 'B', single socketed in any length with rubber ring joints fixed to walls fixed in repair complete all as specified and directed. |
| 68 | S&F PVC (SWR) branch piece single (single Y)110 mm bore with access door fixed in repair complete all as specified and directed. |
| 69 | S&F PVC (SWR) bends any radius 110 mm dia fixed in repair complete all as specified and directed. |
| 70 | S&F 75mm PVC (SWR) pipes class 'B' single sockets, in any length with rubber ring joints, fixed to walls complete as specified and directed. |
| 71 | S&F 75mm bore PVC (SWR) pipes class 'B' single sockets, in any length with rubber ring joints, laid in ground or floors 75mm dia complete as specified and directed. |
| 72 | S&F in repairs, PVC (SWR) 75 mm dia, floor trap, plain with granting including jointing to waste pipe with solvent cement and fixing in PCC 1:2:4 complete all as specified and directed. |
| 73 | Dismantling of stone slabs or tiles of any description or thickness as in floors, pavings, aprons, pathway etc laid dry or laid dry and pointed complete all as specified and directed. |
| 74 | M&L for 75 mm thick PCC type D-2 1:4:8 ( using 40mm graded stone aggregate) as in sub base of floor complete all as specified and directed. |
| 75 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade of 80 mm thickness, with grey cement and pigment laid over sand cushing complete all specified and directed.Note :- Sand cushioning will measured and paid seperately. |
| 76 | S&F for Machine pressed precast concrete coloured interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and pigment laid over sand cushing complete all as specified and directed. Note :- Sand cushioning will measured and paid seperately. |
| 77 | All as per item No 76 above but except tiles (old tiles to be re-used) complete all as specified and directed. |
| 78 | Supply and laying of sand including spreading, levelling and ramming in layers n.exc. 25 cm thick in each layer complete all as specified and directed. |
| 79 | M&L for Pre-cast (Factory casted) cement concrete Kerb stone casted in PCC (1:2:4) Type B-1 using 20mm graded stone aggregates with plan or interlocking joints (as directed) and setting and jointed in cement mortar 1:6, complete all as specified and directed. |
| 80 | M&L for preparation of kerb stone, new un-treated concrete or plastered surfaces of any description over 10cm girth or width, not otherwise described and applying two coats of synthetic enamel paint in black and white colour over a coat of primer complete all as specified and directed. |
| 81 | M&L for Laquer coated Chequered cement concrete coloured tiles 30cmx 30cmx25mm thick set jointed in neat cement slurry and pointed in grey cement mixed with pigment to match the shade of tiles incl 15 mm thck cement screed in CM 1:6 complete all as specified and directed. |
| 82 | S&F in repairs 15 mm bore pillar taps, cast copper alloy, chromium plated, fancy type with capstan heads, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed. |
| 83 | S&F in repairs Toilet paper holder with flat recessed type stainless steel complete all as specified and directed. |
| 84 | S&F in repairs health faucet cast copper alloy with push button flexible steel pipe with PVC lining of 1 mtr long suitable for 15mm pipe complete all as specified and directed. |
| 85 | S&F in repairs flexible (coil shaped) PVC waste pipe for sink and wash hand basin 32/40mm dia, length not less than 70 cm, connected to PVC waste coupling/fittings complete all as specified and directed. |
| 86 | Taking up or down 15mm steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed. |
| 87 | Refixing 15mm old steel tubing and connection in new or old position (wall, ceiling, floors, etc.)complete all as specified and directed. |
| 88 | S&F steel tubing 15mm bore medium grade galvanised with all fittings and fixed complete to wall, ceilings or laid in floors all as specified and directed. |
| 89 | Taking up or down steel tubing and connections including cleaning if refixing required for 20 mm bore of pipe complete all as specified and directed. |
| 90 | Refixing 20mm old steel tubing and connection in new or old position (wall, ceiling, floors, etc.)complete all as specified and directed. |
| 91 | S & F steel tubing 20 mm bore medium grade galvanised with all fittings and fixed complete to wall, ceilings or laid in floors complete all as specified and directed. |
| 92 | M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 for concealed water tubing and making good , cutting not exc 10cm girth complete all as specified and directed. |
| 93 | Dismantling water tanks capacity exc 500 ltrs and n.exc 1000 ltrs and removing to store complete all as specified and directed. |
| 94 | Dismantling water tanks capacity exc 250 ltrs and n.exc 500 ltrs and removing to storecomplete all as specified and directed. |
| 95 | S&F Rotational moulded poly ethylene water storage tanks 500 ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed. |
| 96 | S&F Rotational moulded poly ethylene water storage tanks 1000 ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed. |
| 97 | S&F in repairs 20 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 15mm-142 gms/ 20mm-210 gms/25mm-455gms/ 40mm- 690 gms) complete all as specified and directed. |
| 98 | S&F in repair Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm 125gms) complete all as specified and directed. |
| 99 | M&L for water proofing treatment on RCC roof etc. comprising with the following operation & as specified herein below:- (a)Taking down existing old tarfelt, bituminous compound including cleaning & removing debris to a distance exc 100 m n.exc.250m. (b) M&L 25 thick cement concrete type B0 1:2:4 (12.5 mm graded aggregate) finished even and smooth. (c) Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight). (d) M&L for 20 mm thick screed bed in cement mortar 1:4 finished even and smooth.(e) Preparing & cleaning of fully dried cement plastered surface. (f) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 liters per sqm conforming IS-3384. (g) A layer of APP based polymeric membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (h) One coat of aluminium paint over APP membrane @0.11Kg/Sqm.Note:- Prior to execution of the APP Membrane works, leak proof test shall be done by ponding water on roof slab to minimum depth of 25 mm. The entire roof slab shall be flooded with water for 48 hours. The necessary barrier shall be made to make feasible to stagnate water for 48 hours on roof slab. |
| 100 | M&L for special treatment for sunken portion of WCs/Bath & toilet executed in following stage:- Stage1:- Demolition of wc including lime concrete and cemennt concrete etc and preparing of surfaces of existing sunken portion of wc`s or bath etc with wire brush to removed all loose dirts, oil grease etc including removing debries from site of work etc. Stage 2:- Providing 10mm thick plaster in CM 1:3 mixed with integral water proofing chemical of Dr Fixit Pidicrete URP or plaster seal of STP Ltd in the proportion/quantity all as per manufacturere`s instructions. Stage 3:- Apply Dr. Fixit Premeseal primer or equivelent of STP Ltd (and allow to dry for 8 hrs) all as per manufacturer`s instructions. Stage 4:- Apply two coats of water proofing elastomeric coating system of Dr Fixit Raincoats with DFT 100 micron or shilicry 215 of STP (The surfaces after painting one coats shall be allowed to dry for 6 hrs before next coats) Stage 5:- Rendering 10mm thick in CM 1:3 mixed with integral water proofing chemical of Dr Fixit Pidicrete URP or plaster seal of STP Ltd in the proportion/quantity all as per manufacturere`s instructions. Stage 6:- All CI joints shall be filled with mixture of cement fine sand and plaster seal of STP Ltd or Dr. Fixit pidicrete URP all as per manufacturer`s instructions. Stage 7:- Making holes in walls and fixing 600mm long 40mm dia medium grade GI spouts for draining of excess water if any. Stage 8:- Carryout ponding testfor 48 hrs to ensure water tighteness of repaired sunken portion and filling of sunken portion for cement concrete Type E2, 1:5:10 using 40mm graded stone aggregate as in lean concrete complete all as specified and directed. Note:- only plan area shall be measured for payment under this items. (b) Depth of suken portion of WC`s/ bath shall be upto 35 CM which is to be taken into account while coating the rate against this item. (c) The rate shall be quoted by contractor shall be deemed to be included for all the horizontal and verticl treated surface of sunken portion of WC`s/baths. |
| 101 | Dismantling fencing wire mesh,any type including Mild steel bars, flat iron , nuts & bolts etc complete all as specifeid and directed . |
| 102 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion in concrete, brick work, masonry, etc. and making good disturbed ground. Complete all as specified and directed. |
| 103 | M&L for Cement Concrete type C 2 1:3:6 using 40 mm graded stone aggregate as in foundation filling and mass concrete in fixing of fencing post including necessary form work if required at site complete all as specified and directed. |
| 104 | S&F for fencing post/Hand rails, half round or other stock section including embeding in concrete and screwing etc. wind ties for roof including securing bolt posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 105 | S&F mild steel screw bolts (Machine made) with hexagonal or square heads at one end and the screwed the other to be fitted with washers and one hexagonal or square but exc 5 cm but n.exc 10 cm long, dia of shank 5 to 10mm complete all as specified and directed. |
| 106 | Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and approved by GE. |
| 107 | Fixing only Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wire complete all specified and directed. |
| 108 | S&F mild steel MS round bar 10 mm dia and over cut to length bent to shape required including cranking bending hooking etc and binding with MS wire 0.9 mm dia (annealed) complete all as specified and directed. |
| 109 | S&F in repairs galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed. (each line wire to be measured) |
| 110 | M&L for treating ends of posts, backs of chowkhats, etc., area tarred exc. 0.1 Sqm but n.exc 0.5 Sqm each complete all as specified and directed. |
| 111 | M&L for preparing new plastered surfaces of walls and applying two coats of cement paint over a coat of alkali resistant priming paint complete as specified and directed. |
| 112 | M&L for preparing new steel surfaces of any description width or girth exc 10 cm applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 113 | All as per item No 112 above but n.exc 10 cm width or girth complete all as specified and directed. Please Enable Macros to View BoQ information |