| Sl. No. | Item Description |
| 1 | AC WINDOW/SPLIT TYPE 1.5/2 TONM&L Removing the burnt/defective sealed compressor unit of any make from Window type of air conditioner capacity 1.5Ton by cutting of suction and discharge lines and un-screwing the foundation nuts, supply and fixing of new sealed compressor unit make - Tecumseh Kirloskar, Model RNB 5522 of rotary compressor by tightening the foundation nuts with new fittings and connecting suction and discharge lines with gas welding work complete all as directed at site. |
| 2 | All as per item No 1 hereinbefore above but Air conditioner of 2 ton capacity and sealed compressor unit Make - Tecumseh Kirloskar, Model RNB 5529 complete all as directed at site. |
| 3 | M&L Removing the burnt/defective sealed compressor unit of Split type make from any type of air conditioner capacity 1.5Ton by cutting of suction and discharge lines and un-screwing the foundation nuts, supply and fixing of new sealed compressor unit make - Kirloskar, Model AE 5522E or CR 22K 6 M /AW 1500 by tightening the foundation nuts with new fittings and connecting suction and discharge lines with gas welding work complete all as directed at site. |
| 4 | All as per item No 3 hereinbefore above but Air conditioner of 2 ton capacity and sealed compressor unit complete all as specified and direct ed at site. Make - Tecumseh, Model AW-2000 |
| 5 | Testing and Repairing leakage in system Air conditioner of 1.5 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system and supply & charging refrigerant gas F-22 (approx 1.90 Kg) complete. |
| 6 | All as per item No 5 hereinbefore above but Air conditioner of 2 ton capacity complete all as specified and direct ed at site. gas F-22 (approx 2.30 Kg) complete. |
| 7 | S&F in replacement of electric blower motor capacity 1/7 HP SP 230V, 50Hz, 930/875/825/775 RPM for window type Air conditioner including testing etc complete Make : Gulmarg/GE Motor/Crompton Greaves complete all as specified and direct ed at site. |
| 8 | S&F in replacement of electric blower motor capacity 1/8 HP SP 230V, 50Hz, 1350 RPM for 2 Ton capacity split type Air conditioner including testing etc complete Make : Gulmarg/GE Motor/Crompton Greaves complete all as specified and direct ed at site. |
| 9 | S&F in replacement of electric blower motor capacity 1/13or 1/10 HP SP 230V, 50Hz, 1450 RPM for Split type Air conditioner including testing etc complete Make : Gulmarg/GE Motor/Crompton Greaves complete all as specified and direct ed at site. |
| 10 | S&F in replacement of electric blower motor capacity 1/5 HP SP 230V, 50Hz, 930 RPM for window type Air conditioner including testing etc complete Make : Gulmarg/GE Motor/Crompton Greaves complete all as specified and direct ed at site. |
| 11 | S&F in replacement thermostat for window type AC, working on SP, 230V,AC Make : Indfos/ Ranutrol, complete all as directed at site. |
| 12 | S&F in replacement of PCB circuit with remote control for air conditioner of 1.5 Ton / 2.0 Ton any Make and capacity complete all as specified and direct ed at site. Make : Voltas/Carrier/Ranutrol/LG/Blue star |
| 13 | S&F in replacement air filter for split type Air conditioner (set of three Nos) Make-Marcon or Equivalent complete all as specified and direct ed at site. |
| 14 | S&F in replacement air filter washable of Nilon mesh suitable for window type air conditioner complete all as specified and direct ed at site. Make : Marcon |
| 15 | S&F in replacement starting capacitor 150 to 200 MFD, 440 volts AC ( Suitable for 2 TR split AC) complete all as specified and direct ed at site. Make : Asian/Empire |
| 16 | S&F in replacement starting capacitor 100 to 120 MFD, 440 volts AC ( Suitable for 1.5 TR window type AC) complete all as specified and direct ed at site. Make : Asian/Empire |
| 17 | S&F in replacement running capacitor 36/45 MFD, 440 volts AC ( Suitable for 1.5 TR window AC) complete all as specified and direct ed at site. Make : Asian /Empire |
| 18 | S&F in replacement capacitor 6 MFD, 440 volts AC ( Suitable for fan motor) complete all as specified and direct ed at site. Make : Asian /Empire |
| 19 | S&F in replacement relay box type model-KCH 5230004 Make : Usha/Arvind/Voltas |
| 20 | S&F of copper filter pencil type to any make and capacity of air conditioner complete Make : Vaishali Metal complete all as specified and directed. |
| 21 | S&F in repair front grill of PVC for window type AC of any make complete all as specified and direct ed at site. all as per existing grill |
| 22 | S&F in replacement of selector switch for window type AC complete all as specified and direct ed at site. Make- Blue star/Voltas |
| 23 | S&F of burnt/defective outdoor unit of split AC 1.5 Ton 5 star rating make- voltas/LG/ Samsung with complete sealed compressor unit capacity 1.5Ton and blower ,condenser connecting suction and discharge lines initially filled with refriigeratin gas complete all as directed. |
| 24 | S&F relay over load protector complete set suitable for AC complete all as specified and direct ed at site. |
| 25 | S&F in replacement relay box type model-AC85004 /AC 85001 operating on SP 230 Volt, AC, Make : Usha/Arvind/Voltas |
| 26 | S&F of burnt/defective indoor unit suitable for 1.5 TR split AC 5 star rating make- voltas/LG / Samsung with complete blower, remote senser with remote, conrtolling unit, swinging arrangement and air filter complete all as specified and directed. |
| 27 | M&L for Sub main wiring in repairs with two runs of single core FR LS PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn in and including non metallic rigid PVC conduit of not less than 25 mm dia concealed in wall by cutting chases of wall and making good the disturbed surface, including FRLS PVC insulated unsheathed 4.0 Sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly from main distribution board complete all as specified and directed by Engr-in-Charge. Make of PVC conduit/Casing Caping:- Plaza/Finolex/Polycab/Kalinga/Jindal/Asian& Make Of wire - Make - HPL/L&T/HPL/Havells |
| 28 | S&F of burnt/defective indoor unit suitable for 2.0 TR split AC 5 star rating make- voltas/LG / Samsung with complete blower, remote senser with remote, conrtolling unit, swinging arrangement and air filter complete all as specified and directed. |
| 29 | M&L for Point wiring with FRLS PVC insulated and unsheathed electric cable 1100 volts grade single core having multistranded copper conductor of 2.5 Sqmm nominal cross sectional area for phase & neutral, drawn in and including non metallic rigid PVC conduit in concelead in walls not less than 25mm base size with all fitting and fixing accessories and with 2.5 Sqmm green FRLS PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor connected to earth dolly by providing suitable lugs excluding galvanised boxes of suitable size with white laminated bakelite sheet for mounting switches,sockets etc complete for 15 amps socket point on independent board controlled by one switch. |
| 30 | S&F of burnt/defective outdoor unit of split AC 2.0 Ton 5 star rating make- voltas/LG/ Samsung with complete sealed compressor unit capacity 2.0 Ton and blower ,condenser connecting suction and discharge lines initially filled with refriigeratin gas complete all as directed. |
| 31 | SHIFTING OF AC'SM&Lfor taking down split type AC complete with connectted electric wires, copper tubing, insulation sleeves, outdoor fitting bracket from exiting place and the same fitted to as per requirement/ handed over site,and after fitting complete AC from one place to another place, find leakage in system by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including copper tubing up to 2 running mtr (in replacement), after exceeding 2 Running mtr it (Copper tubing) should measured and paid separately, cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system and supply & charging refrigerant gas F-22 (approx 2 Kg) in air conditioner 1.5 Ton to 2.0 ton completeall as per directed by Engr-in Charge |
| 32 | M&L for Servicing of AC Window/Split type/tower type any capacity and type with water wash through high pressure jet pump and cleaning of all filter using air blower complete all as specified directed |
| 33 | S&F in repairs Copper tubing of following size complete:-(a) 3/8” size |
| 34 | (b) 5/8 ” size |
| 35 | (c) 1” size |
| 36 | (d) 1/4 ” size |
| 37 | (e) 1/2” size |
| 38 | Supply and charging of gas R 134a in AC plant of any capacity complete all as specified and directed by Engr-in-charge. Note:- Gas will be accepted in sealed and tested cylender . |
| 39 | Repair of existing operating pannels of air conditioner (cold store) of capacity 1.5/2 TR and making complete incoming and outgoing connections complete all as specified and directed by Engr-in-charge. |
| 40 | M&L for profile insulation of outdoor unit complete all as specified and directed. |
| 41 | S&F of AC contactor three phase 415-660 volts 32 Amps coil voltages 230 Volt as per sample complete all as specified and directed. |
| 42 | S&F of following parts and fixed complete all as specified and directed. a. Hand shut valve of size 5/8\\" Make- Synergn |
| 43 | b. Pressure gauge (0-500 PSI) |
| 44 | c. Valve 3 way |
| 45 | d. Flair nut 3/4\\" brass |
| 46 | e. Dead plug (brass) |
| 47 | f. Union |
| 48 | S&F MCCB four pole 63 Amp 16 KA 415 volts complete all as specified and directed Make- HPL/Havells |
| 49 | S&F in repairs Sheet metal inclosure with earth plug and socket single pole and neutral with single pole MCB 20 Amps 240 volts complete all as directed. Make:- HAVELL's or equivalent in Legrand/Standard. |
| 50 | S&F in repairs MCB SP, 240 volts, 5-32 Amps, 10KA breaking capacity, 'C' type including connection with suitable size almuminium /copper lugs complete all as directed |
| 51 | M&L Plug top, 3 pin, 15 Amp, SP, 230V, fixed in repairs complete. |
| 52 | M&L for Modular Switch socket combination 20 Amp, 230 volts AC, fixed in repairs complete. |
| 53 | DESERT COOLERSS&F in replacement Complete motor assembly kit of 1/7HPor 200 watts motor, 230V AC, copper winding, complete clamps=04 Nos and water fan 18\\" sweep Make GE Motors/ Crompton/ Havells Mark complete all as specified and direct ed at site. |
| 54 | S&F in replacement vertical pump/Water mersed pump complete tube operated on SP 230V AC Make : Crompton/cool- Home/GE Motors/ISI Marked complete all as specified and direct ed at site. |
| 55 | S&F in replacement wood-wool pad complete heavy size (set of three pads) Approx wt 400 Gms complete all as specified and direct ed at site. |
| 56 | S&F in replacement capacitor 6 MFD, 440V, Make - Empire/ EPCOS/ Capro/ Asian or ISI Mark complete all as specified and direct ed at site. |
| 57 | M&L Scrapping down the complete existing paint inside and out side of desert cooler cleaning the surface and applying two coat of synthetic enamel paint over and including one coat of red oxide primer with sprayer and writing SM/MES No with white black enamel paint complete all as specified and direct ed at site. |
| 58 | S&F of Desert cooler electric driven single phase having norminal air flow capacity of 5600 CuM per hour (peak), Honycamb cooling media, water storage storage tank capacity 65 liters, complete with air blower motor and water mersed pump with water level indicator complete all as specified and directed. Make: Bajaj model No. DMH 65 NEO or eqivelent/Symphony |
| 59 | S&F of Desert cooler Metal body electric driven single phase having norminal air flow capacity of 5400 CuM per hour (peak), Honycamb cooling media, water storage storage tank capacity 50 liters, Air throw coverage- 20 ft, Cooling Medium- Woodwool pads, 05 blades, high speed, fan diameter 18 inch complete with air blower motor and water mersed pump with water level indicator complete all as specified and directed. Make: Khaitan/Symphony/Bajaj |
| 60 | WATER COOLERSSupply, fixing & testing of blower motor for water cooler SP 230V 50 Hz AC 1/12 HP 930 RPM with fan of size 12.5\\" dia complete etc Make : GE Motor/AUE complete all as specified and directed |
| 61 | All as per item No-50 but 1/20 HP 1350 RPM with fan of 13\\" dia complete all as specified and directed. |
| 62 | All as per item No-50 but 1/35 HP, 1350 RPM with fan of 10\\" dia complete all as specified and directed |
| 63 | All as per item -50 above but 1/83 HP 1350 RPM and fan of 9\\" dia complete all as specified and directed. |
| 64 | S&F in replacement starting capacitor 40 to 60 MFD, 275 volts Make- Sharda/Empire/Bhel etc complete all as specified and directed. |
| 65 | All as per item No-54 above but of 60 to 80 MFD complete all as specified and directed. |
| 66 | S&F in repairs running capacitor 10 MFD 440 volts AC Make: EPCOS/ Capro /Asian etc complete all as specified and directed. |
| 67 | All as per item No 56 but of 15MFD complete all as specified and directed. |
| 68 | All as per item No 56 but of 25/30 MFD complete all as specified and directed. |
| 69 | S&F in replacement thermostat for water cooler up to 150 ltr capacity. Make : Ranutrol/Danfoss/Indfos etc complete all as specified and directed. |
| 70 | S&F in replacement push cock heavy duty brass Chromium plated 15mm bore Make- Plumber/Jaquir as approved by GE. complete all as specified and directed. |
| 71 | S&F of float valve 15mm bore of PVC rigid type with polythene ball complete all as directed Make : Prayag or Equivalent as approved by GE. complete all as specified and directed. |
| 72 | S&F starting Relay current type suitable for compressor model= AE 4440M, KCE 443 HAA, CAJ, 34, CAJ 2612M, AE451E, KCE 461 HAE , 513HAE complete, Make-Kirloskar/Tecumseh/ Usha / Arvind |
| 73 | S&F in repairs of over load protector for compressor of water cooler complete all as specified and directed. |
| 74 | S&F of copper filter pencil type to any make and capacity of water cooler etc complete Make : Vaishali Metal complete all as specified and directed. |
| 75 | S&F in replacement of capillary tubing having 0.050/0.055 bore complete Make : Vaishali Metal complete all as specified and directed. |
| 76 | S&F of stop cock 15mm brass heavy duty cromium plated having minimum wet 360 gm Make: Plumber, GEM, Jaquar complete all as specified and directed. |
| 77 | S&F in replacement rubber hose pipe of 20mm size with clip for outlet tray of water cooler approx 1.5Mtr long complete all as specified and direct ed at site. |
| 78 | M&L Removing the burnt/defective sealed compressor unit of any make from water cooler cap 60 ltr/hr By cutting of suction and discharge lines and un-screwing the foundation nuts supply and fixing of new sealed compressor unit make : Kirloskar/Emmerson model : AE 444M or KCE 444 HAA/CAJ34 etc by tightening foundation nuts with new fittings and connecting suction and discharge line with gas welding work etc complete. |
| 79 | All as per item No 69 above but water cooler capacity 80 ltr/hr and S&F compressor Make : Kirloskar/Emmerson Model : CAJ 2612M/AE451E/KCE 461 etc complete. |
| 80 | All as per item No 69 but water cooler capacity 150-150 ltr/hr and S&F compressor Make : Kirloskar/Emmerson Model AHR-13/KCJ 513 complete all as specified and direct ed at site. |
| 81 | S&F in replacement cable PVC 3 core flexible heavy duty copper 2.5 Sqmm complete Make :Plaza/Finolex /Havells complete all as specified and directed. |
| 82 | S&F in replacement single core copper conductor insulalated 2.5 Sqmm complete Make : Plaza/Finolex /Havells complete all as specified and directed. |
| 83 | S&F in replacement cable PVC 4 core flexible heavy duty copper 4 Sqmm complete Make : Plaza/Finolex /Havells complete all as specified and directed. |
| 84 | Repairing Testing the leakage in system by charging of Nitrogen Gas up to 300 PSI. Repairing of leakage spots/Joints with gas welding work, cleaning and flushing the complete water cooler with gas, making the system leak proof, vacuuming the complete system, supply and charging of Freon-22 Gas approx 1.6 Kg complete for water cooler 40/60/120 ltr capacity |
| 85 | M&L Dismantling of water cooler of any capacity and taking out complete internal assembly ie. Inner tank, inlet and out let connection etc and descaling with chemical agent including cleaning and washing and reassembling with same position and making the tank leak proof by necessary brazing/welding work with gasket etc. |
| 86 | M&L Replacement of water cooler inner tank made of stainless steel as per existing capacity (80 Ltrs) & size with necessary gaskets complete set with drilling work fixing with nut,bolts & washer etc complete all as specified and direct ed at site. |
| 87 | All as per item No 76 but 150 but, Ltrs. complete all as specified and direct ed at site. |
| 88 | M&L Replacement of glass wool in 40/60/80/120 ltrs capacity water coolers by taking out inner outer tank and reassembling in same position including testing complete all as specified and direct ed at site. |
| 89 | M&L for repairing of bottom base and legs of water cooler by suitable welding work complete all as specified and directed. |
| 90 | DEEP FREEZERM&L Testing the leakage in system by charging Nitrogen Gas up to 300 PSI. Repairing the leakage spots/Joints with welding work including supply and replacement of filter pencil type copper and capillary tube of existing dia & length. Making the system leakproof vacuuming the system and charging of Gas 134a approx 1.0 Kg and testing complete |
| 91 | S&F in replacement of Relay current type and over load protector complete set suitable for compressor Model KCE 336 & KCE 345/2415 complete all as specified and direct ed at site. |
| 92 | S&F in replacement of thermostat Auto defrost type complete for Deep freezer (Refrigeration of)any make & capacity Make : Ranutrol/Indfos etc complete all as specified and direct ed at site. |
| 93 | M&L Removing burnt/defective sealed compressor unit from deep freezer of any make by cutting of suction and discharge lines and un-screwing of foundation nuts. Supply and replacing of new sealed compressor unit Make : Kirloskar Model :KCS 410 LAA/KCS 412 LAG/Tecumseh 2415 incl necessary gas welding making the system leak proof, testing and tightening the foundation nuts with new grounts and connecting suction and discharge line with gas welding work etc complete. |
| 94 | All as per item No 83 but compressor Make-Tecumseh Model TSK-1350 complete all as specified and direct ed at site. |
| 95 | S&F relay current type and over load protector complete set suitable for compressor model No KCS 410 LAA or KCS 412 LAG fixed in repairs complete all as specified and direct ed at site. |
| 96 | S&F in replacement of drier filter complete set suitable for deep freezer 215 / 386 ltrs complete all as specified and direct ed at site. |
| 97 | Supply, fixing & testing of blower motor for Deep frizer SP 230V 20 watts complete with fan complete all as specified and directed |
| 98 | REFRIGERATOR S&F Relay current type and overload protector complete suitable for compressor model KCE336, KCE345 fixed in repairs complete all as specified and direct ed at site.MAKE : Ranutrol/ Voltas /LG |
| 99 | S&F Thermostat auto defrost type, fixed in repairs for refrigerators any make & capacity 165/310 Ltr Rerfrigerator complete all as specified and direct ed at site. MAKE : Danfos/Ind foss/Ranutrol |
| 100 | Vegitable tray as per sample and suitable for refrigerator Make Godrej, Voltas or whirlpool , LG of capacity 300 Ltr |
| 101 | S&F refrigerator of 3 Star, Smart Inverter Compressor, Convertible, Shiny Steel Finish, Frost-Free Double Door capacity 345 Ltrs complete al as specified and directed Make LG model No- GL-S382SPZX or whirpool /samsung/Equilent |
| 102 | S&F Evaporator suitable for Voltas/Godrej refrigerators capacity fixed in repairs 165/286/300 ltr complete all as specified and direct ed at site . |
| 103 | M&L for removing burnt/defective sealed compressor unit of any make from any type/Capacity (165/286/300/310 Ltr) of refrigerator by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit Make Tecumesh, Godrej, Voltas or whirlpool , LG, including necessary gas welding, making the system leak proof, including Repair to leakage in system by charging of nitrogen gas upto 300PSI, in the refrigeration system, testing and tracing the leakage in system, arresting the leakage with gas welding etc and making the complete system leak proof, vaccumising the system and testing, the system for smooth functioning complete and charging of refrigerent gas 134a complete all as specified and directed at site. |
| 104 | Supply and charging / toping up of gas Freon- 22 with required standared pressure in Split AC of any capacity complete all as specified and directed.Note:- Gas will be accepted in sealed and tested cylinder having capacity 13.6 Kg each. |
| 105 | M&L for checking of AC supply electrical/electronics circuitary and finding fault and rectification the same with replacement of step down transformer 230 volt to 12/24 volts,replacement of faulty PCB of water purification system, and replacement of resistance , small pieces of wires etc complete all as directed . |
| 106 | S&F of AQUA D PURE 4 in 1 Copper RO Water Purifier with 10 Stage Purification Filtration, UV, UF, TDS Adjuster and 12 Liter Large Storage Tank, Suitable for all type of water supply complete all as directed. Make- Aqua guard/ Beetek |
| 107 | Repair of water purifier and replacement of solonoid valve, PF nozzle, EVA tube, boul, including replacement of candle 10'' filter set and cartrige, carbon filter and pri filter set etc installed in various building of Infantry school and MH area and made functional complete all as directed. Make- Aqua guard/ Beetek |
| 108 | M&L Checking the unserviceable plant (such as water cooler, refrigerator, Deep frizer etc) of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete Note:- Petty stores such as insulation tape, screws, small pieces of wires, etc shall be provided by the Contractor. Cost of the same is deemed to be included in the quoted unit rate. |
| 109 | M&L Removing the burnt/defective sealed compressor unit of Tower type make from any type of air conditioner capacity 4.0 Ton of 3 phase by cutting of suction and discharge lines and un-screwing the foundation nuts, supply and fixing of new sealed compressor unit make - Daikin Model JT160BCBY1L, Kirloskar or Equavalent by tightening the foundation nuts with new fittings and connecting suction and discharge lines with gas welding work complete all as directed at site. |
| 110 | S&F in replacement of PCB circuit with remote control for Tower AC air conditioner cap 4.0 Ton of any Make and capacity complete all as specified and direct ed at site. Make : Voltas/Lloyd/Blue star |
| 111 | S&F in replacement of electric Condentioner motor capacity 120 W SP 230V, 50Hz, 120 W for 4 Ton capacity Tower type Air conditioner of Out door unit including testing etc complete Make : Gulmarg/GE Motor/Crompton Greaves complete all as specified and direct ed at site. |
| 112 | S&F in replacement of electric Blower motor capacity 8 P SP 230V, 50Hz, 120 W for 4 Ton capacity Tower type Air conditioner of Indoor unit including testing etc complete Make : Gulmarg/GE Motor/Crompton Greaves complete all as specified and direct ed at site. |
| 113 | Attending the complaints of non functional and Preventive maintenance of storage type electric water heater (Geyser) of capacity 25/50 ltrs comprising of the following tasks at different locations of any make with technecian team (one electrician and one helper) attend the complaint regularly. Technecian team will collect the complaint from AGE E/M No. 1 office regularly and feed back of the complaint will be submitted on same day complete all as specified and as directed.(a) Inspection of geyser after opening bottom cover plate.(b) Examine water tightness of storage tank.(c) Carry out operation of all stop cocks, pressure reducing valves, etc. to ensure free movement of the working parts.(d) Replace washers and glands of defective taps to ensure water tightness smooth functioning.(e) Inspect vent pipes and remove blockage obstruction if any.(f) Check and correct earth continuity of electrical items.(g) Check and correct temperature setting of thermostats and test its functioning.(h) Checking and adjustments of pressure reducing valves.(i) Checking of dead weight type high pressure release valve (PRV) by removing dead weight protection cleaning the seat and ensuring that the waste hole is not blocked / chocked.(j) Testing of Geysers after repairs/maintenance in all respect for proper functioning. |
| 114 | Taking down storage geyser of any capacity after disconnecting electrical connection from existing socket, removing the bolts and nuts from wall and disconnected inlet and outlet water connection for repair/ replacing the unsv items and assemble the same after making serviceable, cleaning dust including connecting flexible 3 core cable as required, painting the geyser complete, with white colour synthetic enamel paint by spraying and filling cavaties with pillar, one coat after cleaning all dust, with proper filling of glass wool as heat resistance material, suitable quantity etc and refixing the geyser at it's original location complete all as directed spcified by Engineer-in-charge |
| 115 | S&F heating element push type 1.5 KW ISI Marked complete all as specified and directed . |
| 116 | All as per item No. 03 but 2 KW capacity complete all as specified and directed . |
| 117 | S&F heating element triangle type 2.0 KW ISI Marked complete all as specified and directed . |
| 118 | All as per item No. 05 but 1.5 KW capacity complete all as specified and directed . |
| 119 | S&F heating element thread type 1.5KW with ISI Mark complete all as specified and directed . |
| 120 | All as per item No. 07 but 2 KW capacity complete all as specified and directed . |
| 121 | S&F Thermostat ISI marked suitable for the Geysers 25 ltrs/ 50 ltrs capacity, 20 Amps, 240 Volts AC, adjustable type, 210 mm long or nearest size as per sample |
| 122 | S&F Thermostat ISI marked suitable for the Geysers 25 ltrs. to 50 ltrs capacity,20 Amps, 240 Volts AC, fixed type,300 mm long or nearest size, Set at 90+/-6 degreeC as per sample |
| 123 | S&F PVC connections pipe with brass hexagonal adapters both side suitable for 15mm dia pipe 60cm long for cold water as per requirement. |
| 124 | S&F PVC connections pipe (braided coated) with brass hexagonal adapters both side suitable for 15mm dia pipe 45 cm long for hot water as per requirement. |
| 125 | S&F PVC connections pipe (braided coated) with brass hexagonal adapters both side suitable for 15mm dia pipe 60cm long for hot water as per requirement. |
| 126 | S&F Non-return valve 15mm / 20mm dia of brass ISI marked as per requirement. |
| 127 | S&F Indicators of Geysers of any capacity/type as per requirement. |
| 128 | S&F Cable PVC insulated 3 core 2.5 Sqmm with stranded copper conductor 1100 Volts grade complete all as specified and directed. Make- Finolex/Havells/Policab |
| 129 | S&F 3 pin plug top, 16 amp capacity, 240 VAC, heavy duty, Make- Westen/Havells/Anchor |
| 130 | S&F Geyser storage inner tank made out of copper sheet suitable for 25 ltrs capacity |
| 131 | S&F Geyser storage inner tank made out of copper sheet suitable for 50 ltrs capacity |
| 132 | S&F Apparatus plate copper of Geysers of any capacity/ type |
| 133 | S&F Safety valve plug made out brass metal with fusible lead, inner thread type suitable for geyser of any type/capacity . |
| 134 | S&F in repair electric saving five star / Four star rated 2 KW rated power water heater storage type (Geyser) of capacity 25 Ltrs with all accessories complete including making water and electric connection all as required at site including 04 Nos of old fashner nuts required suitable size fixed in brick wall including complete all as specified and directed by Engr-in- Charge make Make- Jaquar Model- Elena Vertical or equivelent in Havells model- Bianca |
| 135 | Taking down electric water heater (geyser) of 50 Ltrs capacity from existing system, disconnected inlet and outlet water connection for leakage complaint and replacing the rusted, leakage inner water tank with new one made out of stainless steel and fixing in outer shell with proper filling of glass wool as heat resistance material, suitable quantity, refixing the apparatus plate, geyser element, thermostat etc and also refixing the geyser at it's original location complete all as specified and directed. |
| 136 | Taking down electric water heater (geyser) of 25 Ltrs capacity from existing system, disconnected inlet and outlet water connection for leakage complaint and replacing the rusted, leakage inner water tank with new one made out of stainless steel and fixing in outer shell with proper filling of glass wool as heat resistance material, suitable quantity, refixing the apparatus plate, geyser element, thermostat etc and also refixing the geyser at it's original location complete all as specified and directed. |
| 137 | Attending the complaints of non functional and Preventive maintenance of solar water heating system/ Solar flat plate collector comprising of the following tasks at different locations of any make, complete all as specified and as directed.(a) Inspection of solar heating system and find out leakage in system(b) Examine water pipe line(c) Carry out operation of all stop cocks, pressure reducing valves, etc. to ensure free movement of the working parts.(d) Replace washers and glands of defective taps to ensure water tightness smooth functioning.(e) Inspect vent pipes and remove blockage obstruction if any.(f) Check and correct earth continuity of electrical items.(g) Check and correct temperature setting of thermostats and test its functioning.(h) Checking and adjustments of pressure reducing valves.(i) Checking all electrical connection to ensure proper functioning.(j) Cleaning all glass plate(k) Testing of solar heating system after repairs/maintenance in all respect for proper functioning. |
| 138 | M&L for repair the unserviceable solar water heating system and de-scaling with authourised agent and making serviceable by filling the Distilled water, cleaning the solar toughned glass, stopping the leackage with replacing the old unserviceable CPVC pipe/tee/bend/broken glass tubes etc. complete all as specified and directed. Note1 :- The contractor ensure that all materials/spares once the incorporated in the work, they should maintain warranty for the same through the contract period from the date of executing. |
| 139 | S&F Heating element as per sample including rubber washers (ISI marked) of any type suitable to existing Solar water heater of capacity 2000 watts and connected items all as specified and directed by engr-in- charge. |
| 140 | S&F Heating element as per sample including rubber washers (ISI marked) of any type suitable to existing Solar water heater of capacity 3000 watts and connected items all as specified and directed by engr-in- charge. |
| 141 | S&F Gl tubing medium grade 15mm bore with fitting and connected items all as specified and directed by engr-in- charge Make- Tata, Swastik, Jindal, Prakash, Surya. |
| 142 | S&F Gl tubing medium grade 25mm bore with fitting and connected items all as specified and directed by engr-in- charge Make- Tata, Swastik, Jindal, Prakash, Surya. |
| 143 | S&F GI coupling union 15 mm to 25 mm bore, ISI marked completeand connected items all as specified and directed by engr-in- charge. |
| 144 | S&F Bib taps 15 mm , chromium plated fancy type cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed down,screwed for iron pipe or for unions and connected items all as specified and directed by engr-in- charge . Make- Plumber/Jaquar |
| 145 | S&F Stop valves 15 mm , chromium plated fancy type cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and connected items all as specified and directed by engr-in- charge Make- Plumber/Jaquar |
| 146 | S&F Stop valves 25 mm , chromium plated fancy type cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and connected items all as specified and directed by engr-in- charge Make- Plumber/Jaquar |
| 147 | S&F in replacement of 16 mm external dia Chlorinated Poly Vinyl Chloride (CPVC) pipe consisting of high grade polymer effectively bonded in the inside and outside of an aluminium tube CPVC-AL-CPVC by melt adhesive(including joining/fixing with cement solvent) suitable for hot water supply from solar water heater to the bathrooms and fixed to wall, ceiling etc. including all materials, fittings and fixing works and testing of pipe line test for solvent cement joints and adhesive joints and testing of all materials shall be as per manufactures instructions, literature and confirming to IS-15450 : 2004 or ASTM -1282 including making good the disturbed surfaces complete all as specified and directed. Make- Finolex/Surya |
| 148 | S&F in replacement of 25 mm external dia Chlorinated Poly Vinyl Chloride (CPVC) pipe consisting of high grade polymer effectively bonded in the inside and outside of an aluminium tube CPVC-AL-CPVC by melt adhesive(including joining/fixing with cement solvent) suitable for hot water supply from solar water heater to the bathrooms and fixed to wall, ceiling etc. including all materials, fittings and fixing works and testing of pipe line test for solvent cement joints and adhesive joints and testing of all materials shall be as per manufactures instructions, literature and confirming to IS-15450 : 2004 or ASTM -1282 including making good the disturbed surfaces complete all as specified and directed. Make- Finolex/Surya |
| 149 | S&F in replacement Float valves 15 mm with complete accessories all as specified and directed by Enge-in-charge. Make- Prayag or equivelent |
| 150 | S&F in replacement Float valves 25 mm with complete accessories all as specified and directed by Enge-in-charge.Make- Prayag or equivelent |
| 151 | S&F in repairs MCB SP 6 to 32 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-in-Charge. Make - HPL/L&T/ HPL/Havells |
| 152 | S&F for MCB Single pole and neutral rated capacity 5 to 32 Amps, 240 volts breaking capacity 10 KA complete all as specified and as directed. Make: ABB/L&T/SCHINDER |
| 153 | S&F for MCB Four pole rated capacity 63 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed.Make: ABB/L&T/SCHINDER |
| 154 | S&F in repairs Sheet metal inclosure with earth plug and socket single pole and neutral with single pole MCB 20 Amps 240 volts complete all as directed. Make:- HAVELL's or equivalent in Legrand/Standard. |
| 155 | S&F in repairs Metal clad plug, 2 pole with earth terminal capacity 20 Amp fixed in existing single pole and neutral enclosure complete.Make:- HAVELL's or equivalent in Legrand/Standard. |
| 156 | S&F single core PVC insulated and sheathed cable with multistranded aluminium condutor of size 10 Sqmm Weather proof flat twin core cable for service connections from pole to Distribution board complete all as specified and directed Make:- HAVELL's / finolex/Policab |
| 157 | S&F of sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor cable of size 4.00 sqmm LT, 1100 volts grade, drawn through and including 25 mm dia PVC non metallic conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 4 sqmm single core multistranded copper conductor cable green colour as earth continuity conductor. Note:- (i) Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 25mm dia shall be measured as one run lenght. (ii) Cable required for connection to DBs shall deemed to be included and shall not be measured seperately. (iii) Earth wire shall run inside the PVC conduit. |
| 158 | M&L for Point wiring with FRLS PVC insulated and unsheathed electric cable 1100 volts grade single core having multistranded copper conductor of 2.5 Sqmm nominal cross sectional area for phase & neutral, drawn in and including non metallic rigid PVC conduit in concelead in walls not less than 25mm base size with all fitting and fixing accessories and with 2.5 Sqmm green FRLS PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor connected to earth dolly by providing suitable lugs excluding galvanised boxes of suitable size with white laminated bakelite sheet for mounting switches,sockets etc complete for 15 amps socket point on independent board controlled by one switch. |
| 159 | S&F in replacement of 100 LPD Puf insulated stainless steel hot water storage tank for 100 LPD solar water heater storage tank material 316 grade stanless steel outer clading material powdar coated GI sheet with inlet and outlet water connections. complete all as per site requirement and directed by Engr-in-charge. |
| 160 | S&F in replacement of 200 LPD Puf insulated stainless steel hot water storage tank for 200 LPD solar water heater storage tank material 316 grade stanless steel outer clading material powdar coated GI sheet with inlet and outlet water connections. complete all as per site requirement and directed by Engr-in-charge. |
| 161 | S&F in replacement of 300 LPD Puf insulated stainless steel hot water storage tank for 300 LPD solar water heater storage tank material 316 grade stanless steel outer clading material powdar coated GI sheet with inlet and outlet water connections. complete all as per site requirement and directed by Engr-in-charge. |
| 162 | M&L for maintanance and servicing of following mentioned OT light fittings including control panel, suspension spring including all connected items and carring out routing check OT lights for smooth functioning all as per menufacturer instructions and entire setisfaction of engr-in-charge (a) Unserviceable spares which are required to be replaced shall be measured and paid saperately in relevent items (b) Authourised personel should repair the unit (c) Clean the light housing and arm using mild soap and sterlized water mixture. Apply this mixture to a clean cloth and wipe down the light head and arm (d) Check frount lens and optics to ensure there are no chips,cracks or other (e) Check to see that all mounting and attachement screws, wisher etc are in place securely tightened. Replace any missing screw retighten as required.(i) OT-I |
| 163 | (ii) OT-II |
| 164 | (iii) OT-III |
| 165 | (iv) OCU |
| 166 | (v) MI Room |
| 167 | S&F in replacement of Projection Lamp for operation surgical light Type 7027 Cat Part No BRL/BCD AI/220 of 12 V, 50 Wand 50Hz frequence and connected items all as specified and directed by engr-in- charge Make- Philips |
| 168 | S&F in replacement of Electronic Transformer Dimming by normal' phase-cut' dimmer short circuit and over voltage protection. Working with Main supply 240 v, 50-60 Hz , Lamp power 50 w, Lamp voltage 12 v Ac. and connected items all as specified and directed by engr-in- charge Make- Philips |
| 169 | S&F in replacement sensing card of online UPS 5KVA including cleaning, dusting and tightness of all electrical connection Make - Microtech all as specified and directed by engr-in- charge |
| 170 | S&F in replacement of sheet metal enclosures single pole and neutral 4 way, 240 volt with 200 Amp rated bus bar for DBs (double door) , complete all as specified and directed Make- Havells/Legrant |
| 171 | S&F in replacement of sheet metal enclosures Triple pole and neutra 8 way, 240 volt with 200 Amp rated bus bar for DBs (double door) , complete all as specified and directed Make- Havells/Legrant |
| 172 | S&F Rotational moulded PVC water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position of capacity 500 ltrs complete all as directed at site. Make- Syntex Suprimo or equivent |
| 173 | S&F Rotational moulded PVC water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position of capacity1000 ltrs complete all as directed at site. Make- Syntex Suprimo or equivent Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |