| 1 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering/ valley gutter |
| 2 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 3 | S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall/valley gutter, fixed with self tapping screws as specified |
| 4 | S&F 3mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc as specified |
| 5 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete |
| 6 | Dismantling Joist, channel, angle, tubler trusses or tee sections, fixed independently, without connecting plates, etc. |
| 7 | Dismantling structural steel work in cluding doors, gates but excluding framed trusses etc, complete all as specified |
| 8 | M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161 1979 grade St.-240 complete all as specified |
| 9 | S&F wind ties for roof including securing bolts work conforming to Fe-290 Gde E-165 as specified and directed |
| 10 | S&F MS 1.25 mm thick MS plain black sheet in steel gates and similar work, cut to size, holes punched, including round headed screws and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded as required. |
| 11 | S&F Expanded metal not less then 4 kg/sqm , cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members as specified |
| 12 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar ficings, dressed stone work and pre-cast concrete articles complete all as specified and directed. |
| 13 | M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed |
| 14 | Taking down cement or cement lime plaster of any discription on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 15 | M&L for 12 to 15 mm thick smart care ready mix repair plaster with high quality polymer additive and well graded sand and fillers which can be used for plastering ( as per manufacturer instruction ) over interior surface of wall complete all as specified and directed. |
| 16 | M & L for preparation of new plastered surface and applying two coat of cement base paint over a coat of alkali resistant priming paint on external surface etc complete all as specified and as directed. |
| 17 | M & L Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings .complete all as specified (Payment for providing grooves shall be made separately). |
| 18 | M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge |
| 19 | M&L for applying three coats of white wash on new plastered surface with mechanical complete all as specified and directed. |
| 20 | M&L for applying two coats of white wash on old plaster surface with mechanical complete all as specified and directed. |
| 21 | Demolition of cement concrete (unreinforced) in any position n.exc 15cm thickness (below or above ground level) complete all as specified and directed. |
| 22 | Disposal of removed/demolished soil/materials exc 1.50 km but n. exc 5 km and depositing where directed complete all as specified and directed |
| 23 | M & L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10 cm width or girth, not otherwise described complete all as specified and directed. |
| 24 | M&L for preparation of old paint on steel and iron surfaces of any description not other wise described over 10 CM width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 25 | M&L 100mm thickness PCC 1:4:8, type D2 (using 40mm graded crushed stone aggregate) as in sub base of hardstanding complete all as specified |
| 26 | M&L 100mm thickness PCC 1:2:4, type B1 (using 20mm graded crushed stone aggregate) as in hardstanding incl necessary joints all in alternate panels complite all as specified and directed. |
| 27 | M&L 75mm thick PCC 1:2:4 type B1 using 20mm graded crushed stone agg mixed with metalic hardner all as specified as in flooring, surface of flooring finished even and smooth with using extra cement complete all as specified |
| 28 | M&L for 75mm thick cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in plinth protection /path finished even and smooth without using extra cement complete all as specified and directed. |
| 29 | M&L for Glass dividing strips, 3 mm and 38mm wide inserted in position, conform to design thick completeall as specified all as specified. |
| 30 | S&F in repairs PVC (SWR) pipe single socket in any length with rubber ring joints fitted to wall 110mm complete all as specified and directed |
| 31 | Material and labour for point wiring with 1.5 Sqmm copper conductor (Multi-standard) PVC insulated and unsheathed electric cable 1100 volts in and including PVC Conduit of suitable size with all fittings/ accessories in concealed and including PVC insulated and unsheathed electric cable 1100 volts1.5 Sqmm ( multi-stranded) copper conductor single core( Green co lour) cable as continuous earth wire connected to common earth dolly including 50 mm deep box made of 2nd class hard board of required size and shape etc covered with 3 mm thick plastic laminated sheet ( Make Hylum) for one light point independent controlled by one, one way switch complete all as specified and as directed by the Engineer-in-Charge. |
| 32 | All as per item No 31 above, but for one 3 pin socket outlet 5 Amp on same board complete all as specified and as directed by the Engineer-in-Charge. |
| 33 | All as per item No 31 above, but for one 3 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge. |
| 34 | Supply and fixing switch piano flush button single pole one way 5 Amps complete all as specified and as directed by the Engineer-in-Charge. |
| 35 | Supply and fixing socket outlet multipurpose 2 pin and 3 pin, 5 Amp, flush type complete all as specified and as directed by the Engineer-in-Charge. |
| 36 | All as per serial item No 31 here-in-before, but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor (Multi-stranded) insulated and unsheathed electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 1.5 Sqmm copper stranded conductor as continuous earth wire connected to common dolly complete all as specified and as directed by Engineer-in-Charge. |
| 37 | Supply and fixing switch socket combination multi purpose 2 in 1, 3 pin 5 Amp and 15 Amp, flush type complete all as specified and as directed by Engr-in-charge |
| 38 | Supply and fixing ceiling rose, surface bakelite, 65 x 50 mm, three terminals complete all specified and as directed by the Engineer-in-Charge. |
| 39 | Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amp MCB |
| 40 | Supply and fixing LED lights fitting Rechargable type 1x 16W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete |
| 41 | S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. |
| 42 | Supply and fixing in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including fixing arrangment at wall/pole all as directed. |
| 43 | Supply & fix exhaust fans AC single phase 230/ 240 V of size 380 mm sweep with louver alongwith cutting of holes and making good disturbed Area by plastering and two coat of paint all as directed at site. |
| 44 | Supply and fix in replacement MCB DB sheet metal enclosure factory fabricated double door SPN 6 way with 100 amps copper rated bus bar 240 volts IP-43, IK-09 with metal doors complete all as specified and directed. |
| 45 | Supply and fix in replacement MCB DB sheet metal enclosure factory fabricated double door SPN 12 way with 100 amps copper rated bus bar 240 volts IP-43, IK-09 with metal doors complete all as specified and directed. |
| 46 | Supply and fixing MCB SPN 240V, 50 Hz, 10KA 'C' curve miniature circuit breaker (MCB) and current carrying capacity 32 Amp rating in the MCB DB complete with connection testing and commissioning complete all as specified & directed. |
| 47 | Supply & fix MCB SP, 6 to 40 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. |
| 48 | Supply and fix steel water tubing medium grade galvanised with all fitting laid in wall/pole of 25 mm bore Note : Cutting of existing pipe and GI Fittings are included. |
| 49 | Supply and fix stop/ gate valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed of 25 mm bore |
| 50 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm nominal cross section in service connections |
| 51 | Supply and fix electric water heater, storage type steel body with fiber flash coated inner tank and heating element upto 5 KW capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate alongwith all water connections one No Bib tap 2 no stop cock alongwith flexible pipe all as directed by Engr-in-Charge. |
| 52 | Disconnecting & taking up or down existing unserviceable UG cable/service wire aluminium conductor including GI wire any size and type, complete all as specified and directed. |
| 53 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core. |
| 54 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in soft/loose/ soil for taking out/laying CI/GI pipe line and getting out soft/loose soil complete all as specified and as directed by Engineer-in-Charge. |
| 55 | Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge. |
| 56 | Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and as directed by Engineer-in-Charge. |
| 57 | Supplying and laying un-reinforced precast concrete cable cover LV type-I flat size 250 mm x 150 mm x 40 mm in trenches for protection of cable. |
| 58 | M&L for sand cushioning dry fine for cable cushioning below and above the cable complete all as directed at site by Engr- in-Charge. |
| 59 | Supply and fixing GI Pipe 40mm Light grade , for cable protection laid in trench under road or path or fixed on pole or wall with clamps with all fittings complete all as specified and as directed at site. |
| 60 | S&F in replacement LED Batten surface/wall mounted with specially designed powder coated aluminium housing,high optically efficient polycarbonate diffuser,in built electronic driver duly wired up to terminal block,power consumption<20W,luminaire lumen >2000 lm,system efficiency of >120 lumens/W,LED make Nichia/Cree/Everlite/Eclison/Osram/lumiled,with LED binning as per ANSI Bin C78.377A,photo biological safety report as per IEC 624718& electrical insulation class 1 Ingress protection IP 20,color rendering index CRI> 80 ,temp range 0 to 450 C ,driver efficiency >85% Power factor >0.9 THD <20% as per IEC 61000-3-2 ,color temp -6500K,Surge protection 2.5 KV,50000 burning hrs (min) as per L7O criteria,two stages isolated constant current operated driver with range 150-270 V AC and safety extra low voltage safe level< 60 V DC as per IEC standard with LM70 & LM 80 certification. |
| 61 | S&F in replacement LED security with aluminum pressure die cast housing, high purity PC fresnel diffuser with silicon gaskets for IP-65 protection, power consumption of 45 W and system efficiency > 100lm /W, in built electronic driver pre-wired upto terminal block with driver efficiency > 85% power factor > 0.95, suitable for external pole upto 35mm LED Make :- Nichia/Cree/Osram, CRI > 70, ambient temperature range 0-450c, THD<10%, colour temperature 5700K, surge protection cm 3.5KV 50000burning hour as per L70 criteria, multistage constant current constant voltage operated driver with range 150 -270 V AC and safety extra low voltage safe level < 60V DC as per IEC standard including GI pipe medium grade ISI mark of size 32 mm dia length not less than 1.5 mtrs bending to shape for fixing light and nuts, bolts, clamp as required to fix to wall all as specified and directed. |
| 62 | Supply and fixing in replacement of high wattage LED Highbay light offers more brightness with wider light spread of rated wattage of 150W suspended mounting, with IP20 protection glass complete all as specified and directed. |
| 63 | Supply & fixing for ceiling rose PVC Polycarbonate isolated body 62.5x25mm, terminals, complete all as specified & directed. |
| 64 | Taking down care fully sub main wiring / service connections of any size including batten/ conduit, including fittings and making good the disturbed surfaces of wall/ floor . |
| 65 | M&L for sub main wiring with two runs of single core FRLSH PVC insulated, unsheathed, multistranded copper conductor cable of size 2.5 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 25mm dia with its accessories, concealed type, including one run of single core FRLSH PVC insulated, unsheathed, stranded copper conductor cable of size 2.5 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes:- Finished sub main wiring with two runs of 2.5 sqmm cable & one run of 2.5 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. |
| 66 | All as per an item no.63 but for conductor cable of size 6.0 sqmm, complete all as specified and directed. |
| 67 | All as per an item no.63 but for conductor cable of size 4.0 sqmm, complete all as specified and directed. |
| 68 | Taking down distribution boards any size any type including MCB TPN/SPN/DB etc and making good the disturbed surfaces. |
| 69 | Supply and fix in replacement TPN DB sheet metal enclosure factory fabricated double door 4 way with 200 amps rated copper bus bar 240 volts IP-54, IK-09 with metal doors complete all as specified and directed. |
| 70 | Supply and fix in replacement MCB DB sheet metal enclosure factory fabricated double door SPN 4 way with 200 amps rated copper bus bar 240 volts IP-54, IK-09 with metal doors complete all as specified and directed. |
| 71 | Supply and fixing in replacement MCB SPN 240V, 50 Hz, 10KA 'C' curve miniature circuit breaker (MCB) and current carrying capacity SPN 20 Amp rating in the MCB DB complete with connection testing and commissioning complete all as specified & directed. |
| 72 | Supply & fix MCB SP, 6 to 32 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. |
| 73 | M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm size, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including galvanized steel earth lead wire of 4 mm dia, including 15 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mm formed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Loose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, all as per electrical plate no:3 of SSR part-1 . Please Enable Macros to View BoQ information |