| 1 | Demolition of unreinforced cement concrete as in roof, floors (other than ground floors), beams, staircases, landings, chajjas etc complete all as specified and directed. |
| 2 | M&L for PCC (1:2:4), type B0 ( using 12.5 mm graded aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs,, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 3 | Demolition of reinforced Cement concrete of any descrpition and in any position not otherwise specially provided if cement concrete is reinforced (reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 4 | M&L for reinforced cement concrete type B-1 (1:2:4) (using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies,canopies,deck slab and in shelves etc complete all as specified and directed. |
| 5 | S&F mild steel TMT steel bars 10mm dia and over, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 6 | S&F TMT steel bars 6 to 8mm dia, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 7 | M&L for use and waste form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (horizonal or sloping) for flat rough finished surfaces of concrete complete all as specified and directed. |
| 8 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 9 | M&L for brick work using locally available first class bricks sub class 'B' bricks (old size brick) well burnt, straight or curved on plan exceeding 6 m mean radius, built in cement mortar (1:6) complete all as specified and directed. |
| 10 | M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius, built in cement mortar (1:4) as in half brick thick walls complete all as specified and directed. |
| 11 | Taking down chowkats or frame exceeding 1.5 Sqm and not exceeding 4.00 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed. |
| 12 | Taking down chowkats or frame not exceeding 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed. |
| 13 | Taking down shutters of any description exceeding 1.0 Sqm but not exceeding 2.0 Sqm each complete all as specified and directed. |
| 14 | Taking down shutters of any description not exceeding 1.0 Sqm each complete all as specified and directed. |
| 15 | Taking down and refixing shutters of any description exceeding 1.0 sqm but not exceeding 2.0 sqm each in the same opening after repair work complete all as specified and directed. |
| 16 | Refixing shutters of any description not exceeding 1.0 sqm each in the same opening after repair work complete all as specified and directed. |
| 17 | S&F solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed. |
| 18 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet & edges will be painted to match with prelam sheet, reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and directed. |
| 19 | S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded, plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, complete all as specified and directed. |
| 20 | S&F Factory Made Solid PVC Moulded Door Shutter with partcle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm Plain colour PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. |
| 21 | S&F well seasoned second class hard wood plain, solid, straight chowkat and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints including treating the timber libarally brushed at least twice with oil or kerosene based solusion of chlorophyrifos 20EC 1.0 % (by weight) concentration complete all as specified and directed. |
| 22 | S&F pressed steel door frames conforming to IS : 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 125 mm x 60 mm, profile C, single rebate including hinges, mortar guards, lock strike plate, shock absorbers including PCC (1:2:4) type B-1 for filling of hollow section complete all as specified and directed. |
| 23 | S&F pressed steel door frames conforming to IS : 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 105 mm x 60 mm, profile C, single rebate including hinges, mortar guards, lock strike plate, shock absorbers including PCC (1:2:4) type B-1 for filling of hollow section complete all as specified and as directed. |
| 24 | S&F 35 mm thick, second class hard wood well seasoned, glazed and skeleton shutters with open rebated and prepared to receive glass, gauze, etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut mitered beads for securing glass, etc, sizes of members of shutters as specified in SSR Part I, Section -8, clause 8.24 (a), complete all as specified and directed. |
| 25 | S&F 35mm thick second class hard wood well seasoned plain, framed, panelled shutters (any number of panels), with panels of 12mm thick veneered particle board medium density with commercial face veneers: supplied and fitted to chowkats, sizes/section of members of shutters shall be as specified in SSR Part I, Section -8, clause 8.24 (a) complete all as specified and directed. |
| 26 | S&F 30 mm thick, second class hardwood well seasoned glazed and skeleton shutters open rebated and prepared to receive glass, gauge, etc, divided in to squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded as specified in SSR Part I Section 8 clause 8.24 (b) complete all as specified and directed. |
| 27 | S&F in repair galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.00mm and fixed with wooden bit or stainless steel wire staples as required complete all as specified and directed. |
| 28 | S&F stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 29 | S&F in repair stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 30 | S&F aluminium anodised, window and ventilator shutters, fixed type, with or without sash bar, using aluminium section weighing not less than 0.55Kg per metre including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws etc complete all as specified and directed.Note : (a) Thickness of aluminuim section shall not be less than 1.5mm.(b) Glass will be measured and paid separately. Please Enable Macros to View BoQ information |
| 31 | S&F aluminium anodised, window and ventilator shutters, fixed type, with or without sash bar, using aluminium section weighing not less than 0.55Kg per metre including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws etc complete all as specified and directed.Note : (a) Thickness of aluminuim section shall not be less than 1.5mm.(b) Glass will be measured and paid separately. Please Enable Macros to View BoQ information |