| 1 | M&L for cleaning of sludge from septic tanks soakage well/ pits, man holes etc of any capacity and depth by taking out the sludge ( solid material), removing the waste materials from outside MOD land and burying in pits including soreadingf well in oits after burying of sludge and covering the pit with 25 cm thicklayer of local earth available and cover the pit to make it hygienically fit, complete all as specified and as directed.(Excavation for pit shall be included in this item |
| 2 | M&L for cleaning of blocked SGSW/CI/PVC drain pipe sewage line any type & dia in horizontal or vertical position by rodding from man hole to man hole ends to septick tanks/ soakage wells well flushing after taking out exiting man hole coverw taking out sludge and other materialsblocked the drains pipes excavation of pits carraige and levelinng of spoil pits after brrying of sludge and removal of surplus spoil to a distance not exceesing 50 mtr, complete all as specified and as directed. |
| 3 | M&L for cleaning blockage of gully trap of any size and depth WC urinal etc by dewatering and getteing out foreign materials scum etc and removing outside defence land including CI/SGSW/pipe of any dia from gully WC urinal amy floor to man hole of bldg, complete all as specified and as directed. |
| 4 | Demolition of brick work or stone masonary or block masonary etc built in cement mortar of any descreption including eccavtion and removal where ever required for embeded portion, complete all as specified and as directed. |
| 5 | M & L for walling of rondom rubble, uncoursed well bounded, bededed and solidly hearted, built in cement mortar 1:6, complete all as specified and as directed. |
| 6 | Ditto all as per item No 5 above but except stones, complete all as specified and as directed. |
| 7 | M&L for brick work with sub class B; bricks (Old size straight or curved on plan exceeding 6 mtr mean radius in CM 1 :6, complete all as specified and as directed. |
| 8 | M&L for flush pointing to random rubble masonary, uncoursed or brought upto courses in CM 1:3, complete all as specified and as directed. |
| 9 | Extra over stone walling for hammer dressing to face of stones and dressing of face beds and joints, as specified of random rubble walling uncoursed or brought upto courses with maximum depression on face from straight edge held against the dressed surface n exc 20 mm on granite or trap stone, complete all as specified and as directed. |
| 10 | Demolition of concrete in ground floors and paving n. Exc 15 cm thickness (below or above ground level, complete all as specified and as directed. |
| 11 | M&L for PCC (1:2:4) type B1 (using 20 m gradedstone aggregate ) as in coping etc including all necessary from works, complete all as specified and as directed. |
| 12 | M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded agg as in plinth protection finished even an smooth w/o using extra cement, complete all as specified and as directed. |
| 13 | M&L for 25 mm thick PCC type B1 (1:2:4) using 20 mm graded agg a in flooring finised even and fair w/o using extra cement, complete all as specified and as directed. |
| 14 | M&L cement concrete type D-2 ( 40 mm graded agg ) !:4:8 type using 40 mm graded agg 75 mm thick as in sub base, complete all as specified and as directed. |
| 15 | Taking down cement palster on brick or stone walls etc from drian, wqalls and Manholes etc including raking out joints hacking for key scrubbing down with water etc, complete all as specified and as directed. |
| 16 | M&L for rendering 15 mm thick in CM 1:4 over stone wall surfaces and finished even & smooth without using extra cement, complete all as specified and as directed. |
| 17 | Demolition and breaking up drain pipe 75/100 mm dia (AC, saltglazed, pvc or RCC pipes) set in CM or any descreption incl Excn of Earth work,RFR removal and making good, complete all as specified and as directed. |
| 18 | M&L for PCC (1:4:8) type D2 (using 40 mm garded stone aggregate as in as bed to drain pipes including packing under and haunching against the sides of pipes after these are laid tested for 150 mm bores of pipes, complete all as specified and as directed. |
| 19 | S&F of 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floor fixed complete using PVC solvent and necessary testing etc, complete all as specified and as directed. |
| 20 | M&L for 150 mm bore of pipe Reinforcd concrete pipes class NP2 laid and jointed complete with collars incl demotion and breaking up drain pipe, complete all as specified and as directed. |
| 21 | M&L for (150x 100) mm Sali glazed stone ware gully traps square or found mouthed, type P, complete all as specified and as directed. |
| 22 | S&F of 110 mm bore PVC (SWR) bends/Tee etc, complete all as specified and as directed. |
| 23 | S&F of 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors fixed complete using PVC solvent and necessary testing etc, complete all as specified and as directed. |
| 24 | S&F of 75 mm bore PVC (SWR) bends/Tee etc fixing, complete all as specified and as directed. |
| 25 | M&L in repair for 10 user LLDPE septic tank (conventional ) designed to carr sewage and sullage water, excavtion in any type of soil, PCC 1:4 below foundation vent shaft connection etc, complete all as specified and as directed. |
| 26 | S&F in repairs of setting in cement mortar 1:3 and flauching with cement concrete 1:2:4 type B-I cast oron man hole covers and frames medium duty any type and size, complete all as specified and as directed. |
| 27 | Demolition of cement concrete reinforcement cut as required to faclitate demolition) in ground floors and paving n exc 15 CM thickness (below or above ground level), complete all as specified and as directed. |
| 28 | M&L precast RCC manholes cover in cement concrete 1:2:4 type B-1 using 20 mm graded stone aggretegate, complete all as specified and as directed. |
| 29 | Mild steel TMT bars 8 mm dia quality conforming to Grade 415 MPA cut to length bent to shape required including crancking, bending and blinding with mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified and as directed. |
| 30 | S&F in repair vitreous chine wash down water closet pan (Peddestal pattern) white or clourred exculiding flushing cistern and flush pipe and incl seat cover provn of concrete/white cementing & Por S trap in repairs, complete all as specified and as directed. |
| 31 | S&F in repair PVC flushing cistern 10 lts capacity low lwvel including brackets, inlet and outlet PVC pipe and fitting, complete all as specified and as directed. |
| 32 | S&F in repair Vitreous china squatting pan, Orissa pattern size 630 X 450 mm white with integral foot rests (excluding flushing cistern and flush pipe), complete all as specified and as directed. |
| 33 | S&F in repair Viterous China urinal, flat back of size 465x355x265mm white (minimum) with grating and union for discharge pipe, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal plugs with and including 60mm long brass screws, pointing around urinal back in cement, including 32mm bore PVC waste pipe fixed in repair incl Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms), complete all as specified and as directed. |
| 34 | S&F in repair vitreous china wash absin white flat back size 550X40mm plug,porcelin stopper and incls brackets with waste fitting and conection pipe etc incls pedestal, complete all as specified and as directed. |
| 35 | Dismantling floor hearth wall tiling including cement mortar bedding, removing serviceable tiles to store and rubbish of the premises, complete all as specified and as directed. |
| 36 | M & L for non skid coloured printed ceramic tile 8 to 10 mm thick ( Square/rectangular/in joint less) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm,in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over 15 mm thick screed bed in CM (1:4), complete all as specified and as directed. |
| 37 | M & L for glazed ceramic tiles in vertical surface 600x300x10 mm thick colour and design (as approved) in vertical surface and jointed in neat cement slurry and pointed in whiter or colour cement to match the colour of tiles over 10 mm thick cement plaster using CM (1:4), complete all as specified and as directed. |
| 38 | S & F grating doom 125 mm dia of PTMT (minimum weight 25gms ), complete all as specified and as directed. |
| 39 | Note:- Schedule of credit Rs 13,535.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents. Please Enable Macros to View BoQ information |