| 1 | Taking down carefully copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets etc for taking credit removing from site and making good disturbed surface etc. |
| 2 | Material and labour for point wiring with 1.5 sqmm cable FRLS PVC insulated, unsheathed copper multistranded conductor, 1100 V grade of size 1.5 sqmm including necessary termination board 1.5 Sqmm PVC insulated unsheathed FRLS copper conductor as earthing and connected to common earthing with PVC heavy duty casing caping/PVC conduit ISI marked as rquired at site along with all accessories and making good the disturbed surfaces of wall/ ceiling etc for the following : - Note : Colour coding for point and sub main wiring should be maintained at site. Incase of any deviation necessary recovery will be made as applicable. |
| 3 | One light point/ one fan point/ Bell Point controlled by one switch |
| 4 | One 3 pin socket outlet, 5 Amp independent |
| 5 | One 3 pin socket outlet 5Amps on same board with other switches |
| 6 | M&L for point wiring for power point with 2.5 Sqmm FRLS PVC insulated unsheathed copper cable 1100 Volt grade drawn through and including PVC casing caping heavy duty ISI marked /heavy duty conduit ISI marked as required at site alongwith accessories with 2.5 Sq mm FRLS PVC insulated unsheathed copper conductor cable as earthing wire and connected to common earth complete all as specified. |
| 7 | S & F switch socket combination 15 Amp flush type complete all as specified. |
| 8 | S & F Switch socket combination 5 Amp complete all as specified. |
| 9 | S&F switch piano flush type single pole one way 5 amp all as specified. |
| 10 | S&F holder any type for batten fitting complete all as specified |
| 11 | S&F electric bell, AC 230Volts single pole complete all as specified. |
| 12 | S&F bell push flush type single pole one way 5 amp all as specified. |
| 13 | S & F Ceiling rose 3 terminals complete all as specified & directed |
| 14 | S&F LED in repairs light fitting 1X20 watts,220V AC decorative box type with driver,holder including LED tube light connecting up with two/three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 15 | S&F in repairs white LED luminaire 600X600 mm,35/36 watt,220V recessed type with high efficiency PMMA diffuser soft glare free light complete with driver,holder and LED suitable for roof ceiling including connecting up with driver three core flexible copper conductor of suitable size. |
| 16 | S&F in repairs warm white LED luminaire 600X600 mm,35/36 watt,220V recessed type lumen output >= 122 lumen per watts , THD < 10% environmental friendly , new generation , aesthetically designed , ultra modern with high brightness SMD LEDs as light source incl inbuilt drivers with high efficiency PMMA diffuser soft glare free light complete suitable for roof ceiling including connecting up with three core flexible copper conductor of suitable size all as specified and directed. |
| 17 | S&F in repairs LED light fitting mirror type 2 ft long 10 watt ,220 V AC decorative type with driver holder including LED lamps and connecting upto flexible copper conductor of suitable size all as specified and directed. |
| 18 | Suply and fix in replacement Track mounted LED light with modern design, campact size with High power COB LED to provide Focussed light 9/10 W. Complete all as specified and directed . |
| 19 | S&F in replacement distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 12 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface complete all as specified and directed |
| 20 | S&F in replacement distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface complete all as specified and directed |
| 21 | S&F in replacement distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface complete all as specified and directed |
| 22 | S&F in replacement sheet metal enclosures distribution boards,double door 4 way three phase 415 volts MCCB,ISOLATOR&MCB,s comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following (a) MCCB 4 Pole 100 AMPS AC 415 V 10 KA=01 NO as incoming & outgoing MCB SP-12 No 40 AMP Note :- (i)The DB shall be of VTPN series (ii) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(iii)connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped.(iv) all the vacant holes of the DB shall be provided with blank plates of appropriate size.(v) double continuous earth wire shall be provided for each three phase DB from earthing mains dolly. |
| 23 | S&F in repair MCB single pole,SP 6 to 32 Amp 240 volt B curve 10 KA, IP 20 complete all as specified and directed |
| 24 | S&F in repair for Circuit breaker single pole & neutral SPN 240 volt C curve 10 KA 32 Amps capacity IP 20 complete all as specified and directed. |
| 25 | S&F in repair MCB SPN SPN 40 to 63 Amps,10 KA, 240 volt C curve IP 20 complete all as specified and directed incl taking down old one |
| 26 | Taking down old u/s submain wiring of any sizes complete all as specified & directed. |
| 27 | M&L for sub main wiring with two run of single core PVC insulated copper cable multi-stranded conductor 2X6 Sqmm drawn through in and including Non metalic PVC heavy duty PVC casing caping of suitable size as required at site with all accessories with 1X6 Sqmm PVC insulated unsheathed copper conductor as earth wire, connected to common earth complete all as specified and directed |
| 28 | M&L for sub main wiring with two run of single core PVC insulated copper cable multi-stranded conductor 2X4 Sqmm drawn through in and including Non metalic PVC heavy duty PVC casing caping of suitable size as required at site with all accessories with 1X4 Sqmm PVC insulated unsheathed copper conductor as earth wire, connected to common earth complete all as specified and directed |
| 29 | S&F in repairs G I tubing 40 mm dia light grade galvanised with all fittting and fixed fix on wall ceiling or laid in floors complete all as specified and direceted at site . |
| 30 | S&F in repair casing and caping 25mm/PVC heavy duty including all fixing accessories complete all as specified and directed . |
| 31 | M&L for earthing complete with galvanized steel earth plate electrode60cmX60cmX6mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth lead wire of 4.0 mm dia by means of nuts bolts, washers, check nuts of iron or steel including PCC pits and RCC cover in PCC 1:2:4 (type B-1) and necessary earth work in any type of soil medium grade GI watering pipe 20 mm dia with funnel and wire mesh and 15mm bore GI pipe light grade protection pipe upto test point etc including excavation and charcoal, common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I. all specified and directed. |
| 32 | S&F in repair Modular switch 6 Amp one way 240 V as per sample complete all as directed by Engr- in- Charge |
| 33 | S&F in repair Modular switch 16 Amp one way 240 V as per sample complete all as directed by Engr- in- Charge |
| 34 | S&F in repair Modular socket 6 Amp 3 pin 240 V as per sample complete all as directed by Engr- in- Charge |
| 35 | S&F in repair Modular socket 16 Amp 3 pin 240 V as per sample complete all as directed by Engr- in- Charge |
| 36 | S&F in repair Modular plate with support frame 3 module complete as per sample all as directed by Engr- in- Charge |
| 37 | S&F in repair Modular plate with support frame 6 module complete as per sample all as directed by Engr- in- Charge |
| 38 | S&F in repair Modular plate with support frame 8 module complete as per sample all as directed by Engr- in- Charge |
| 39 | S&F in repair flexible casing circular type complete all as specified and directed . |
| 40 | S&F in repair casing and caping 20mm/PVC heavy duty including all fixing accessories complete all as specified and directed . |
| 41 | S&F in repair switch socket combination 2 in 1,3 pin 5 and 15 Amp flush type. |
| 42 | All as per item No 39 above but 5A flush type |
| 43 | S&F in repair switch piano type 5 Amps 230 volts one way. |
| 44 | S&F in repair recess mounting LED panel 12 W 160mmX160mm luminaire white/warm white powder coated CRCA housing with LED seamless front frame with flat white high transmission acrylic cover. Make :- Bajaj Squadra 12W or equivalent make in wipro/Havells/CG |
| 45 | S&F hylam sheet of size 20X10 CM 3mm thick, white complete all as specifed and directed by Engr-in-charge. |
| 46 | S&F hylam sheet of size 30X20 CM 3mm thick, white complete all as specifed and directed by Engr-in-charge. |
| 47 | Deduct Credit for Demolished/Dismantled material Rs (-)52,460.00 (Minus) as listed in Schedule 'A' Part-II (Credit Schedule)Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'. Please Enable Macros to View BoQ information |