| 1 | Desilting of existing drains and removal of sludge / harden soil carefully without disturbing side wall including disposal of soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed |
| 2 | Demolition of cement concrete (unreinforced) of any description in any position complete all as specified and directed |
| 3 | M&L for PCC (1:4:8), type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete all as specified and as directed |
| 4 | M&L for PCC (1:2:4), type B-1 (using 20mm graded crushed stone aggregates) as in coping including weathering, slightly rounded or chamfered angles and necessary use and waste of form work complete all as specified and directed |
| 5 | Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar ashlar facings, dressed stonework, precast concrete articles and precast concrete block walling etc complete all as specified and directed. |
| 6 | M&L for pre-cast cement concrete block masonry with solid blocks of mix 1:3:6 (using 20mm graded crushed stone aggregates) exceeding 10 cm in width and setting in mortar cement (1:6) complete all as specified and directed |
| 7 | Taking down cement plaster on brick/concrete/stone masonry walls etc incl racking out joints, hacking for key, scrubbing down with water etc complete including removing rubbish off the premises complete all as specified and directed |
| 8 | M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick work or concrete block wall or concrete surfaces finished even and smooth without using of extra cement complete all as specified and directed. |
| 9 | M&L for pre-cast reinforced cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) as in cover slab set and jointed in CM 1:4 including necessary form work complete all as specified and directed. |
| 10 | M&L for TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hoping for columns end and binding with mild steel barber wire (annealed) not less than 0.9 mm dia complete all as specified and directed |
| 11 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends complete all as specified and directed |
| 12 | Material, T&P and labour for cleaning of sewage line of any dia/bore using the cleaning devices as per rule 5 and protective gear and safety devices as per rule 4 of the prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing blockage if any complete all as specified and as directed. |
| 13 | Cleaning of gully trap/Nahani trap/water closet up to firstt manhole from ground floor to third floor by rodding as directed including refixing of grating in position with white cement and removing the debris as directed including cutting of small vegetables where ever found at site complete all as specified and directed. |
| 14 | Cleaning of blocked / socked manholes including removal of dirt etc to a place not exc 50mm including removing and refixing existing man hole cover slab without damage and any depth of manholes complete all as specified and directed. Please Enable Macros to View BoQ information |
| 15 | Cleaning of blocked / socked manholes including removal of dirt etc to a place not exc 50mm including removing and refixing existing man hole cover slab without damage and any depth of manholes complete all as specified and directed. Please Enable Macros to View BoQ information |