| 1 | Dismantling timber scantlings 40 sqcm and over in section in any position unframed work, complete all as specified and as directed. |
| 2 | S&F in repair 2nd class softwood in scantling clean swan timber framed and fixed to the position to replace old and decayed timber, complete all as specified and as directed. |
| 3 | S&F Softwood 2nd class Clean sawn with butt joints eaves boards 20 mm thick, complete all as specified and as directed. |
| 4 | M&L Weather boarding, 25 mm thick, wrought both sides, V-jointed to give 20mm laps and fixed, complete all as specified and as directed. |
| 5 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 including dismantling of wrough iron of any descrption, complete all as specified and as directed. |
| 6 | Dismantling timber scantlings in fillets, rails,posts rafters,purlins etc under 40 sqcm in section unframed work, complete all as specified and as directed. |
| 7 | M&L for plain fillets square rectangular or triangular in section using 2nd class soft wood clean swan secured with nails exc 13 but n. exc 25 sqcm in section, complete all as specified and as directed. |
| 8 | M&L plain fillets square rectangular or triangular in section using 2nd class soft wood clean swan secured with nails not exc 3 sqcm in section, complete all as specified and as directed. |
| 9 | Dismantling of wall and celling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness inlcuding cover fillets, complete all as specified and as directed. |
| 10 | S&F 6 mm thick insulation consisting of PVC Insulated Panels as in wall having expanded polystyrene (EPS) stuck to 2mm thick plain colour PVC sheet duly fitted into the wall as per specifications and drawing.Note : Panelling should be rested on L/U shape edge profile of same pattern (PVC/Aluminium) complete all as spd and as directed. |
| 11 | M&L 4 mm thick Plywood in ceiling, grade BWR,type BB, fixed with screws to timber frame work, complete all as specified and as directed. |
| 12 | S&F 6 mm thick insulation consisting of PVC Insulated Panels as in ceiling having expanded polystyrene (EPS) stuck to 2mm thick plain colour PVC sheet duly fitted into the wall as per specifications and drawing.Note : Panelling should be rested on L/U shape edge profile of same pattern (PVC/Aluminium), complete all as specified and as directed. |
| 13 | M & L 4 mm thick veneered decorative plywood ,grade 1 (with BWR resin) with decorative face veneers on both faces,in wall fixed with screws to timber frame work, complete all as specified and as directed. |
| 14 | S & F second class Softwood 15 mm thickness planed both sides and edges tongued and grooved or rebated,and fixed with nails any situation, complete all as specified and as directed. |
| 15 | Demolition of brick work, PCC block masonary, stone masonary or boulder masonry built in cement mortar, complete all as specified and as directed. |
| 16 | M & L for brick work with sub class 'B' bricks (old sizes) straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6, complete all as specified and as directed. |
| 17 | M & L For Rendering 15 mm thick plastering on brick work or concrete surface in CM (1:6) and rendering is to be finished even and smooth w/o using extra cement, complete all as specified and as directed. |
| 18 | M&L for Preparing newly plastered surfaces and applying two coat of cement base paint over a coat of primer with alkali resistant priming paint, complete all as specified and as directed. |
| 19 | Taking down cement plaster or screed bedding layer of any description from concrete slab/terrace surfaces etc including racking out joints hacking for key, scrubbing down with water etc, complete all as specified and as directed. |
| 20 | M & L For Rendering 10 mm thick plastering on brick work or concrete surface in CM (1:4) and rendering is to be finished even and smooth w/o using extra cement, complete all as specified and as directed. |
| 21 | M&L for Preparation of undecorated/old surfaces of walls and applying one coat of oil emulsion, complete all as specified and as directed. |
| 22 | M&L for preparation of undecorated/old surfaces of walls and applying one coat of white wash, complete all as specified and as directed. |
| 23 | M&L for preparation of new plastered surfaces and applying three coats of white wash, complete all as specified and as directed. |
| 24 | Demoliton of cement concrete (un-reiforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level), complete all as specified and as directed. |
| 25 | M&L for 25 mm thick PCC type B-1 (1:2:4) using 20 mm graded agg as in flooring finised even and fair w/o using extra cement, complete all as specified and as directed. |
| 26 | M& L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded aggregate as in plinth protection finished even and smooth w/o using extra cement, complete all as specified and as directed. |
| 27 | M & L for non skid coloured printed ceramic tile 8 to 10 mm thick ( Square/rectangular/in joint less) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm,in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colur of tiles over 15 mm thick screed bed in CM (1:4), complete all as specified and as directed. |
| 28 | Dismantling floor hearth wall tilling including cement mortar bedding, removing serviceable tiles to store and rubbish of f the permishes, complete all as specified and as directed. |
| 29 | M & L for glazed ceramic tiles in vertical surface 600x300x10 mm thick colour and design (as approved) in vertical surface and jointed in neat cement slurry and pointed in whiter or colour cement to match the colour of tiles over 15 mm thick cement plaster using CM (1:4), complete all as specified and as directed. |
| 30 | M & L Cement concrete in foundations, filling and mass concrete1:3:6 type C-2 using 40 mm graded aggregate 75 mm thick, complete all as specified and as directed. |
| 31 | M& L Machine pressed rubber moulded coloured precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment, complete all as specified and as directed. |
| 32 | M & L for vitrified ceramic tiles 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm in floors dado etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM (1:6), complete all as specified and as directed. |
| 33 | S&F Durapaved chequered tiles (vitrified) 30 cm x30 cm x 8 to 10 mm thick set ,jointed and pointed in neat cement slurry in floors over 20 mm thick screed bed in CM (1:6) finished with cloured cement to match the shed of the slab, complete all as specified and as directed. |
| 34 | Taking down chowkats or frames but with shutters (without taking off shutters from the frame) exc 1.5 Sqm and n.exc 4.00 sqm, complete all as specified and as directed. |
| 35 | Taking down chowkats or frames but with shutters (without taking off shutters from the frame) not exc 1.5 Sqm, complete all as specified and as directed. |
| 36 | Taking down shutter of any description area exc. 1 sqm but n. exc. 2 sqm each, complete all as specified and as directed. |
| 37 | Taking down shutter of any description area n. exc. 1 sqm each, complete all as specified and as directed. |
| 38 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and as directed. |
| 39 | S&F Sheet glass thickness 3.00 mm,ordinary quality and glazing with oil putty in square not exceed 0.5 sqm in each pane including, complete all as specified and as directed. |
| 40 | S&F 2nd class soft wood glazed and skeleton shutters 35 mm thick , open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified and as directed. |
| 41 | S&F Plain, framed,panelled shutters thickness 35 mm of 2nd class softwood,(any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, complete all as specified and as directed. |
| 42 | S&F Glazed and skeleton shutters thickness 30 mm,(2nd class softwood), open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters supplied and fitted to chowkats if windows, ventilators, etc. are provided with stiles and rails as in SSR Part I, Sectionspecified 8 clause 8.24(b), complete all as specified and as directed. |
| 43 | M&L two coats of synthetic enamel paint over a coat of pink primer including preparation of surface on wooden sruface over 10 cm width or girth, complete all as specified and as directed. |
| 44 | S&F Door closer hydraulically regulated cost iron body designation No 1 universasl type suitable for door shuutters up to 700 mm in width and of weeight not more than 35 kgs, complete all as specified and as directed. |
| 45 | S&F Aluminium anodised, barrel tower bolts 100 mm of extruded section and fixed, complete all as specified and as directed. |
| 46 | S&F Aluminium anodised, barrel tower bolts 200 mm of extruded section and fixed, complete all as specified and as directed. |
| 47 | S&F Aluminium alloy, anodised, sliding door bolt 200 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and as directed. |
| 48 | S&F M S Butt hinges 100 mm medium weight, cold rolled mild steel, complete all as specified and as directed. |
| 49 | S&F M S Butt hinges 75 mm medium weight, cold rolled mild steel, complete all as specified and as directed. |
| 50 | S&F Aluminium handles 100 mm , cast type,anodised, complete all as specified and as directed. |
| 51 | S&F Aluminium handles 150 mm , cast type,anodised, complete all as specified and as directed. |
| 52 | S & F anodised aluminium door shutter with chowkat including 5.5 mm thick tinted glass selected quality with hydroulic floor door closer , hinges.Aluminium section for chowkat weight not less than 0.55 kg per running meter including necessary jointing,cleat glazing clips rubber packing aluminium handles , locking arrangement design and approved by Engr- in -charge, complete all as specified and as directed. |
| 53 | S&F floor door stopper long 140 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring, complete all as specified and as directed. |
| 54 | S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as spd and as directed. |
| 55 | S&F in repair curtain rod, mild steel, chromium plated fixing with stainless steel brackets and funnels stops, rollers etc, complete all as specified and as directed. |
| 56 | S&F Rat tail (helical) door spring 300 mm long fix/welded with chowkat, complete all as specified and as directed. |
| 57 | S&F sheet glass shelf assembly consisting of 5.5 mm sheet glass shelf 12 cm wide with brass chromium plated bracket guard and 60 cm long, complete all as specified and as directed. |
| 58 | S&F corner sheet glass shelf assembly consisting of 5.5 mm sheet glass shelf 12 cm wide with brass chromium plated bracket guard, complete all as specified and as directed. |
| 59 | S&F 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup, complete all as specified and as directed. |
| 60 | M&L two coat of synthetic enamel paint on steel surface over coat of a red oxide including preparation of Surfaces of any description, over 10 cm in width or girth,not otherwise described, complete all as specified and as directed. |
| 61 | M&L two coat of synthetic enamel paint on wooden surface over coat of a pink primer including preparation of Surfaces of any description, over 10 cm in width or girth,not otherwise described, complete all as specified and as directed. |
| 62 | S&F in repair vitreous china wash basin, white flat back size 550x400 mm plug, porcelain stopper and incl brackets with waste fittings and connection pipe etc including pedestal complete all as specified, complete all as specified and as directed. |
| 63 | S&F in repair Vitreous China squatting pan, ‘Orissa’ pattern, size 630 x 450 mm white, with integral foot rests (excluding flushing cistern ) incl flush pipe 60 cm long, complete all as specified and as directed. |
| 64 | S&F vitreous chine wash down water closet pan ( Pedestal pattern) white or coloured excluding flushing cistern and flush pipe and seat cover incl provision of concrete/ white cementing and P or S trap in repairs, complete all as specified and as directed. |
| 65 | S&F PVC flushing cistern, 10 ltrs capacity, low level including brackets, inlet and outlet PVC pipe and fittings complete fixed in repairs, complete all as specified and as directed. |
| 66 | S&F in repair Vitreous China squatting pan, ‘Orissa’ pattern, size 630 x 450 mm white, with integral foot rests (excluding flushing cistern and flush pipe), complete all as specified and as directed. |
| 67 | Viterous China urinal, flat back of size 465x355x265mm white (minimum) with grating and union for discharge pipe, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal plugs with and including 60mm long brass screws, pointing around urinal back in cement, including 32mm bore PVC waste pipe fixed in repair incl Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms), complete all as specified and as directed. |
| 68 | S&F in repairs pillar taps, 15 mm dia cast copper alloy fency type with capstan heads, chromium plated. screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks & fly nuts screwed for iron pipe, complete all as specified and as directed. |
| 69 | S&F Brass CP centre hole basin mixer complete all as specified, make - Johnson or equivalent in repair , complete all as specified and as directed. |
| 70 | S&F for 15 mm bore in repair bib taps, fancy type chormium plated with crutch or butterfly handle screwed down screwed for iron pope or for brass ferrule in repair, complete all as specified and as directed. |
| 71 | S&F in repair stop valves fancy tupe chromium plated screwed down high presure , with crutch or butterfly handle, cscrewed both ends for iron pipe or for unions 15 mm bore, complete all as specified and as directed. |
| 72 | S&F in repair PVC (SWR) pipes 110 mm single socketed, in any length with rubber ring joints, laid in trenches or in floor, complete all as specified and as directed. |
| 73 | S&F in PVC (SWR) junction single T equal or unequal 110 mm dia, complete all as specified and as directed. |
| 74 | S&F PVC (SWR) bends 110 mm dia fixed, complete all as specified and as directed. |
| 75 | S&F in repair PVC (SWR) pipes 75 mm single socketed, in any length with rubber ring joints, laid in trenches or in floor, complete all as specified and as directed. |
| 76 | S&F in PVC (SWR) junction single T equal or unequal 75 mm dia, complete all as specified and as directed. |
| 77 | S&F PVC (SWR) bends 75 mm dia fixed, complete all as specified and as directed. |
| 78 | S&F PVC connection pipe 15 mm size with PTMT nuts of length 600mm fixed to GI tubbing, complete all as specified and as directed. |
| 79 | Taking down and replacement with 3-layer PP-R polypropylele random copolymer) concealed pipe SDR 7.4 (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PRR plain & brass threaded polypropylele random fittings fixed complete to walls, ceiling or in floors, complete all as specified and as directed. |
| 80 | S&F in repair brass chromium plated tubular towel rail 20 mm dia D type , 60 mm long between flages, complete all as specified and as directed. |
| 81 | S&F Stop/angle valves 15 mm, cast copper alloy, screwed down,high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed fancy type, chromium plated, complete all as specified and as directed. |
| 82 | S & F Brass CP wall mixer 15 mm for mixing hot & cold water screwed down for iron pipe and fixed, complete all as specified and as directed. |
| 83 | S&F CP health faucet hand held triggered nozzle and delivers a spray of water with pipe, complete all as specified and as directed. |
| 84 | S&F CP jet spray with flexible tube 1.5 mtr long, complete all as specified and as directed. |
| 85 | Excavation in trenches for sewage line in any type of soil, n exc 1.5 M wide and n exc 1.5 M deep for foundation, etc or for shafts, wells, manholes etc n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in any type of soil, complete all as specified and as directed. |
| 86 | Returning filling in incl spreading leveling, watering and well ramming in layers n exc 25 cm, complete all as specified and as directed. |
| 87 | Removing excavated materials n exc 50M and depositing where directed at a level n exc 1.5 M above the starting point, complete all as specified and as directed. |
| 88 | Demolition of cement concrete reinforcement cut as required to facilitate demolition) in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and as directed. |
| 89 | M & L precast RCC manholes cover in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate, complete all as specified and as directed. |
| 90 | Mild steel TMT bars 8 mm dia, quality conforming to Grade 415 MPA cut to length , bent to shape required including cranking , bending and binding with mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and as directed. |
| 91 | M&L in repair for 10 User LLDPE septic tank (conventional) designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc, complete all as specified and as directed. |
| 92 | Demolition and breaking up drain pipe75/100 mm dia (AC,saltglazed, PVC or RCC pipes ) set in CM or any description incl Excn of Earthwork , RFR, removal and making good, complete all as specified and as directed. |
| 93 | M&L for PCC (1:4:8) type D2 using 40mm graded stone aggregates as in bed to drain pipes including packing under and haunching against the sides of pipes after these are laid tested for 150 mm bore of pipes, complete all as specified and as directed. |
| 94 | M&L for 150 mm internal dia Sail-glazed stoneware drain pipes laid in trenches and jointed as specified, complete all as specified and as directed. |
| 95 | M&L for 150 mm bore of pipe Reinforced concrete pipes, class NP2, laid and jointed complete with collars, complete all as specified and as directed. |
| 96 | Note:- Schedule of credit Rs 41,409.53.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents. Please Enable Macros to View BoQ information |