| 1 | Disconnecting and taking down existing old BER Air Conditioners of any type / any capacity / any make from the existing location and depositing the same in MES Store Yard complete all as specified and as directed. |
| 2 | Disconnecting and taking down existing old BER Refrigerators of any type / any capacity / any make from the existing location and depositing the same in MES Store Yard complete all as specified and as directed. |
| 3 | Disconnecting and taking down existing old BER Ice Cube Making Machine of any capacity / any make from the existing location and depositing the same in MES Store Yard complete all as specified and as directed. |
| 4 | Disconnecting and taking down existing old BER Air/Desert Coolers of any capacity / any make from the existing location and depositing the same in MES Store Yard complete all as specified and as directed. |
| 5 | Supply, installation, commissioning and testing of Refrigerator, single door, electric driven (single phase), capacity 100 Ltr or nearby size in upper side with eco friendly refrigerant, BEE 5 star rated with Inverter compressor. Make : Samsung/LG/Whirlpool/Godrej |
| 6 | Supply, installation, commissioning and testing of Refrigerator, single door, electric driven (single phase), capacity 215 Ltr or nearby size in upper side with eco friendly refrigerant, BEE 5 star rated with Inverter compressor complete all as specified and as directed.. Make : Samsung/LG/Whirlpool/Godrej |
| 7 | Supply, installation, commissioning and testing of Refrigerator, double door, electric driven (single phase), capacity 320 Ltr with eco friendly refrigerant, BEE 5 star rated with Inverter compressor complete all as specified and as directed.Make : Samsung/LG/Whirlpool/Godrej |
| 8 | Supply, installation, commissioning and testing of Ice making machine of capacity 260Litres self standing,made out of stainless steel body air cooled with Non CFC refrigerant working on single phase power supply 100 Kg/24Hrs or nearest capacity within + 10 % range of rated capacity and 60 Kgs or nearest capacity within + 10 % range of ice storage bin complete all as specified and as directed. Make : Blue Star/Voltas/Celfrost. |
| 9 | S&F desert cooler electric driven (single phase), having nominal air flow capacity of minimum 4000 CuM per hour (or nearest size) Plastic/PVC Body complete all as specified and as directed.. Make : Bajaj/Havells/Crompton/Symphony |
| 10 | Supply and install Hi wall split type AC units indoor/outdoor complete with cordless remote control unit and with in built air ioniser invertor type compressor, 100% copper tubing of Indoor & Outdoor cooling & condenser unit respectively with CFC free gas for better indoor air quality with 5 star rating and EER 3.2 of capacity 1.5 TR single phase including cabling work, insulation between indoor unit to outdoor unit and provision of MS Brackets for resting of outdoor units (where reqd) or making resting platform of outdoor unit by brick works complete all as specified and as directed. Make : Carrier/Daikin/Hitachi/Blue Star. |
| 11 | Supply and install Hi wall split type AC units indoor/outdoor complete with cordless remote control unit and with in built air ioniser invertor type compressor, 100% copper tubing of Indoor & Outdoor cooling & condenser unit respectively with CFC free gas for better indoor air quality with 5 star rating and EER 3.2 of capacity 2.0 TR single phase including cabling work, insulation between indoor unit to outdoor unit and provision of MS Brackets for resting of outdoor units (where reqd) or making resting platform of outdoor unit by brick works complete all as specified and as directed. Make : Carrier/Daikin/Hitachi/Blue Star. |
| 12 | S & F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 270 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and as directed. Make : V-Guard/ Vinitec/ Microtek. |
| 13 | M & L for concealed sub main wiring 2 x 4.0 Sqmm for phase and neural, 1 x 4.0 Sqmm for earth wire PVC insulated (heavy duty) 1100 volts grade, FRLSH, with single core copper conductor & including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of stone concrete or slab walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, cutting not exceeding 10cm girth complete all as specified and as directedNote :- Two runs of 04 Sqmm cable with 01 run of 4 Sqmm earth wire along with PVC conduit shall be measured as one RM (from distribution board to metal clad switch socket point near AC). |
| 14 | S & F sheet metal enclosures single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB SPN 20 Amps, complete all as specified and as directed. |
| 15 | M&L for PVC pipe 20 mm dia heavy duty with all fittings and fixing accessories such as coupler, lock nut, saddle, pipe hook and laid on floor (for wash out line) complete all as specified and as directed |
| 16 | M&L for high thermal conductivity and corrosion resistant Copper Tube of size 1/4 inch (6mm) with nitrile rubber insulation including all fittings and fixing accessories used in extended length complete all as specified and as directed |
| 17 | M&L for high thermal conductivity and corrosion resistant Copper Tube of size 5/8 inch (16mm) with nitrile rubber insulation including all fittings and fixing accessories used in extended length complete all as specified and as directed |
| 18 | M&L for high thermal conductivity and corrosion resistant Copper Tube of size 1/2 inch (13mm) with nitrile rubber insulation including all fittings and fixing accessories used in extended length complete all as specified and as directed. |
| 19 | M&L for high thermal conductivity and corrosion resistant Copper Tube of size 5/8 inch (16mm) with nitrile rubber insulation including all fittings and fixing accessories used in extended length complete all as specified and as directed. |
| 20 | M & L for making holes by core cutting machine on stone/concrete / brick walls.Dia of hole not exc.50mm and thickness of wall 50cm to 70cm for entry of suction and discharge pipes of AC and making good disturbed surfaces with cement mortared and finally finished with plaster of paris and painted the disturbed surfaces with existing type of paint and tint complete all as specified and as directed |
| 21 | Taking down existing copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed. |
| 22 | M & L for point wiring complete with and including single core PVC FRLSH insulated unsheathed flexible bright annealed multi stranded copper conductor cables 1.5 Sqmm (22/0.30 mm) 1100 volts grade drawn through and including heavy grade PVC rigid conduits 20 mm or higher dia as reqd at site, totally concealed in walls/floors/ceiling including all conduit accessories/fittings/junction boxes/inspection covers etc; of heavy grade, ISI marked and modular sunken terminal boxes of factory made 16 SWG pressed steel housing, totally concealed in walls with modular sheet top cover, fixed flush with wall surface by means of brass screws and sunk/cup washers, for mounting of switches, sockets fan regulates etc; including 1.5 Sqmm (22/0.30 mm)1100 V grade FRLS,PVC insulated, unsheathed flexible multi stranded copper conductor cable as continuous earthwire connected to metallic bodies of luminaires/fans etc; at one end and to common earth dolly at other end, complete all as specified and as directed. (a) One light/Fan point controlled by one way switch 6 Amps 240 volts |
| 23 | Ditto All as per item No. 22 above but one 3 pin socket outlet, 5/6 Amps on the same board with other switches |
| 24 | Ditto All as per item No. 22 above but one 3 pin socket outlet, 5/6 Amps, independent |
| 25 | M&L concealed point wiring complete with and including single core PVC FRLSH insulated unsheathed flexible bright annealed multi stranded copper conductor cables 4.0sqmm 1100 volts grade drawn through and including heavy grade PVC rigid conduits 20 mm or higher dia as reqd at site, totally concealed in walls/floors/ceiling including all conduit accessories/fittings/junction boxes/inspection covers etc; of heavy grade, ISI marked and modular sunken terminal boxes of factory made 16 SWG pressed steel housing, totally concealed in walls with modular sheet top cover, fixed flush with wall surface by means of brass screws and sunk/cup washers, for mounting of switches, sockets etc; including PVC insulated ISI marked unsheathed FRLS cable size 4 sq mm copper conductor as earth wire to common earth dolly complete all as specified and as directed.One 3 pin socket outlet, 15/16 Amps, independent |
| 26 | S&F modular switch 1 way 10 A 1 module complete all as specified and as directed |
| 27 | S&F Modular socket 6 A 2/3 Pin 2 module complete all as specified and as directed. |
| 28 | S&F modular switch 1 way 16 A 1 module complete all as specified and as directed. |
| 29 | S&F Modular socket 6 A/16A 2/3 Pin 2 module complete all as specified and as directed. |
| 30 | S&F in replacement for ceiling rose, 3 terminals /PVC/Polycarbonate, isolated body complete all as specified and as directed. |
| 31 | S&F in replacement of 18/20watt,230V surface and wall mounted warm white LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper conductor cable from ceiling rose complete all as specified and as directed.Make- Luker LT5M20 / Havells ENDURA LINEAR NEO BS20WLED865SPCWH / Bajaj BCLAB 20W WH LED P |
| 32 | S&F LED Building Security Light/Street Light fitting 35 W,IP-65 protection made up of die cast aluminium housing with high power LED as lighting source complete fixing with GI bracket made out of 40mm bore GI pipe light grade 1.2 Mtr long bend to shape and fixed to pole/wall with necessary MS clamp accessories complete all as specified and as directed. |
| 33 | Taking down ceiling fan/Exhaust Fan, sealing cable end,dismantling blades and removing fan and blades to store complete all as specified and as directed. |
| 34 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50Hz RPM 1200, Copper winding of sweep 250mm complete all as specified and as directed. |
| 35 | M&L for Provision of PVC conduit for Telephone/TV/LAN/CCTV not less than 25 mm with Cutting chases for concealed conduit wiring, pinning in and making good to surface where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., cutting not exc 10 cm girth including 3 mm thick wall care putty on wall, making surface matching to adjacent surface complete all as specified and as directed. |
| 36 | M&L for Cutting chases for concealed conduit wiring, pinning in and making good to surface where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., cutting not exc 10 cm girth including 3 mm thick wall care putty on wall, making surface matching to adjacent surface complete all as specified and as directed. |
| 37 | Taking down existing copper/aluminium sub main wiring complete for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed. |
| 38 | M&L for concealed sub main wiring with two single core PVC insulated FRLS cables with stranded copper conductors 2.5 Sqmm , 1100 Volts grade in and including PVC conduit medium grade with all fitting & other accessories and copper cable 2.5 sqmm continuous earth wire complete all as specified and as directed. (Two runs of 2.5 Sqmm cable with 01run of 2.5 Sqmm earth wire along with PVC conduit medium grade shall be measured as one RM) |
| 39 | M&L for concealed sub main wiring with two single core PVC insulated FRLS cables with stranded copper conductors 4 Sqmm , 1100 Volts grade in and including PVC conduit medium grade with all fitting & other accessories and copper cable 4 sqmm continuous earth wire complete all as specified and as directed. (Two runs of 04 Sqmm cable with 01run of 4 Sqmm earth wire along with PVC conduit medium grade shall be measured as one RM) |
| 40 | M&L for concealed sub main wiring with Two single core PVC insulated FRLS cables with stranded copper conductors 6 Sqmm , 1100 Volts grade in and including PVC conduit medium grade with all fitting & other accessories and copper cable 6 sqmm continuous earth wire complete all as specified and as directed. (Two runs of 06 Sqmm cable with 01 run of 6 Sqmm earth wire along with PVC conduit medium grade shall be measured as one RM) |
| 41 | Supply and fix in replacement sheet metal enclosures double pole MCB 20 Amps with a two pin and earth plug and socket complete with all accessories etc complete all as specified and as directed. |
| 42 | Supply and fix in replacement sheet metal enclosures TP MCB 63 Amps with three pin and earth plug and socket complete with all accessories etc complete all as specified and as directed. |
| 43 | S&F in replacement MCB DB SPN 12 way Double door sheet metal enclosure factory made suitable for MCB DB's 240 volts,concealed in wall complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site complete all as specified and as directed.Note - MCBs will be measured & paid separately under respective item of sch A, if required to be replaced. |
| 44 | S&F in replacement MCB DB SPN 8way Double door sheet metal enclosure factory made suitable for MCB DB's 240 volts,concealed in wall complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and circuits complete as reqd at sitecomplete all as specified and as directed.ote - MCBs will be measured & paid separately under respective item of sch A, if required to be replaced. |
| 45 | S&F in replacement MCB DB 4way SPN Double door sheet metal enclosure factory made suitable for MCB DB's 240 volts,concealed in wall complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site complete all as specified and as directed.Note - MCBs will be measured & paid separately under respective item of sch A, if required to be replaced. |
| 46 | S&F MCB SP 6 to 32 Amps 240V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing complete all as specified and as directed. |
| 47 | S&F of C Curve MCB SPN 40 Amps working on 240 volts, 50 HZ,10 KA complete all as specified and as directed.. |
| 48 | S&F of C Curve MCB TP 63 Amps working on 240 volts, 50 HZ,10 KA complete all as specified and as directed. |
| 49 | S&F MCCB with rating of 125 Amps, 415 Volts 3 pole with 16 kA breaking capacity,thermal magnetic adjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capacity(Icu). MCCB should be with suitable spreaders and phase barriers for each terminals complete all as specified and as directed. |
| 50 | S&F in replacement of factory made epoxy powder coated Distribution Board TP & N 4 way double door (VTPN MCCB DB) MCCB as In comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout flush to wall and making good disturbed surface and touch up with the same finishes complete all as specified and as directed. Note:MCBs/ MCCBs will be measured and paid separately under respective Sch A item in the schedule |
| 51 | M&L for Earthing complete with galvanised iron earth plate electrode 600 x 600 x 6mm as earthing lead buried directly in ground vertically to depth not less than 2.25 mtr below GL with the top edge of the plate not less than 1.5 mtr from GL, connected to GI earth lead of 4.0mm dia, by means of bolts & nuts, to GI and connected to earthing test point all as shown in electrical plate No. 3 of SSR Part-I of 2009* specified or indicated and testing on completion including excavation / earth work in any type of starta, PCC (1:3:6) type C1 earthing chamber pre cast slab 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric (XPM) weight not less than 4 KG/sqm cast iron frame, funnel with wire mesh GI watering pipe of 20 mm bore medium grade and lugs with and including GI earth wire 4 mm dia with GI protection pipe of 15 mm medium grade 7.5 meter long etc complete tested on completion complete all as specified and as directed.Note: 1. Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. 2. GI wire above 7.5m will be measured and paid separately. |
| 52 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 2 core complete all as specified and as directed. |
| 53 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core complete all as specified and as directed. |
| 54 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 2 core complete all as specified and as directed. |
| 55 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm4 core complete all as specified and as directed. |
| 56 | M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and as directed. |
| 57 | M & L for making holes by core cutting machine on stone/concrete / brick walls.Dia of hole not exc.250mm and thickness of wall not exceeding 50cm and making good disturbed surfaces with cement mortar and finally finished with plaster of paris and painted the disturbed surfaces with existing type of paint and tint complete all as specified and as directed. |
| 58 | S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. |
| 59 | M&L PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and as directed. |
| 60 | Ditto all as per item No. 59 above but 175 x 100 x 50 mm deep |
| 61 | Ditto all as per item No. 59 above but 200 x 150 x 50 mm deep |
| 62 | Ditto all as per item No. 59 above but 250 x 200 x 50 mm deep |
| 63 | Ditto all as per item No. 59 above but 350 x 300 x 50 mm deep |
| 64 | S&F LED flood light 70 watt 230 V AC outdoor type with driver inbuilt thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and LED lamp complete all as specified and as directed. |
| 65 | S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 66 | S&F water proof 8 module plastic box IP 65, for 2x 5/15 Amps swich and socket fixed on the box and unit fitted on external wall complete all as specified and as directed. |
| 67 | S & F in main distribution panel weather proof outdoor type Double door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7032 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-65, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars electrolytic grade of 100 amps current rating, LED Phase Indicators RYB. Incoming MCCB four pole 63A,415 V AC with Thermal Adjusting Ics= 100 % Icu =01No . Out going MCb's 16 SP =4 Nos mounted on DIN Channel The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding and fix horizontally. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. All joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts, washers and AL Lugs etc. The panel shall be provided with 04 Nos 25mmx25mmx4mm thick angle iron supports of not less than each 0.6mtr height duly painted with anti corrosive black paint including earth work and grouted in PCC 1:3:6 at suitable depth as per site requirement including taking down existing one. The overall size of the Busbar panel shall not be less than 400mmx200mmx500mm (LxDxH)including 4 Nos cable entry holes suitable for cable entry up 3.5 C 95 Sqmm at bottom complete all as specified and as directed. |
| 68 | Excavation in trenches n.exc 1.5 M wide and not exceeding 1.5 mts in depth in wide for laying of cables and n exc 1.5 mtr in depth and getting out in hard/dense soil incl dressing/trimming sides and levelling/grading and ramming of bottom of excavation complete all as specified and as directed. |
| 69 | Excavation in trenches n exc 1.5m wide and n.exc 1.5m in depth and getting out in soft/disintegrated rock complete all as specified and as directed. |
| 70 | Returning, filing in incl spreading, levelling watering and well ramming excavated soil in layers not exceeding 25 cm thick each, filling back in trenches after cables have been laid and tested complete all as specified and as directed. |
| 71 | Removing excavated surplus soil obtained from excavation to a distance not exceeding 1.5 m above the starting point, complete all as specified and as directed. |
| 72 | Supply and laying 50 x 38 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 25 to 35 sqmm 3.5 core complete all as specified and as directed. Please Enable Macros to View BoQ information |