| 1 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles including removing of rubish, complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Demolition of cement concrete in ground floor and paving not exc 15cm thick below or above ground level, complete all as specified and directed. |
| 3 | Dismantling wrought iron or mild steel work of any discrption not otherwise provided for complete all as specified and as directed by Engineer-in-Charge |
| 4 | Excavation over areas not exc 1.5 mtr deep and gettting in hard/ dense soil, complete all as specified and directed. |
| 5 | Excavation over areas exc 1.5 mtr deep and not exc 3.0 mtr deep and gettting in hard/ dense soil, complete all as specified and directed. |
| 6 | M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation, filling in and mass concrete, complete all as specified and directed. |
| 7 | M&L for reinforced cement concrete M-30 (Design Mix) as in foundation including raft footings, foundation beams, plinth beams, bases for columns etc, complete all as specified and directed. |
| 8 | Material and labour for reinforced cement concrete M-30 (Design mix) in wall, retaining wall any thickness ,above top of footings, incl attached pillasters and butresses etc complete all as specified and as directed. |
| 9 | Use and waste of formwork to sides of rough finished surfaces of concrete foundation, footing, bases of columns, raft beams, side and soffits (if any) of foundation, plinth beam and similar work, complete all as specified and directed. |
| 10 | Use and waste of formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter for fair finished surfaces complete all as specified and directed. |
| 11 | S&F TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 12 | All as per ser item No 11.00 here-in-above but 6mm dia and over upto and including 10mm dia but as in stirrups, spaces and binders. |
| 13 | S&F Fe 410 -W Gde E-250 quality- B Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and directed. |
| 14 | M&L for preparation of new iron and steel surfaces of any description exc 10cms width or girth and applying two coats of epoxy base paint over a coat of epoxy base red oxide primer complete all as specified and directed. |
| 15 | Taking down concertina coil of any size and description complete all as specifed and directed |
| 16 | S&F concertina coil fencing with punched tape concertina coil 1050 mm dia 6-7 metre openable length, having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq mm with tape (0.52 mm thick) and weight 43.478 gm/ metre complete all as specified and directed . |
| 17 | Dismantling of barbed wire of any size and description complete all as specifed and directed. |
| 18 | S&F Galvanized, 2 strand, steel barbed wire 2.24 mm dia barbed wire with 2mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanized mild steel wire steples or steel pins, etc all as specified and as directed. |
| 19 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick, complete all as specified and directed. |
| 20 | Removing excavated material / soils to a distance exc. 500 mtr but not exc 1.5 Km and depositing where directed at a level not exc.1.5 mtr above the starting point, complete all as specified and directed. |
| 21 | S&F 110mm dia PVC (SWR) pipes single socketed as in pices, in any length with rubber ring joints, laid in weep holes complete all as specified and directed. |
| 22 | M&L for loose filling with aggregates for protection at the mouth of weep holes using 40 to 63 mm graded stone aggregate as shown in drawing. |
| 23 | M&L for preparation of new concrete wall surface and applying for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 24 | M& L for preparation on old concrete wall surface and applying for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces complete all as specified and directed. Please Enable Macros to View BoQ information |
| 25 | M& L for preparation on old concrete wall surface and applying for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces complete all as specified and directed. Please Enable Macros to View BoQ information |