|
| 1 | Comprehensive maintenance and repairs to electrically operated one Make ECE Passanger lift and its controls with safety devices etc with microprocessor variable voltage variable frequency with fault display controller simplex collective selective control to carry 8 patients, of speed 0.7mtrs/sec to serve up to second floor including ground floor with sliding collapsible steel door manually operated thermostat controlled with solenoid valve to prevent accidentally openingo f door during transit with digital car position indicator car operating panel with digital floor position indicator, emergency light, emegency alarm and serial communication system with automatic service device and synchronised leveling including maintenance, repair and replacement of defective parts ( Parts which will be measured and paid separately under relevant items). Inclusive of examination of all safety devices speed governors at fixed periodicity as per requirement, Comducting all laid down safety tests at specified period by qualified and skilled personnel. The lift is required to be serviceable 24 hours round the clock. Any defect noticed during maintenance period shall be attended immediately without any inconvenience to medical authorities, doctor's patients and visitors complete all as specified and directed.[Note :- All the spares/components required for the repair shall be measured and paid separately here-in-after as supply only rates]. |
| 2 | Comprehensive maintenance and repairs to electrically operated one Make ECE stretcher lift, microprocessor variable voltage variable frequency with fault display controller simplex collective selective control to carry patient stretcher with attendant and necessary medical equipments, of speed 0.55m/sec to serve up to second floor including ground floor with sliding collapsible steel door manually operated thermostat controlled with solenoid valve to prevent accidentally openingo f door during transit with digital car position indicator car operating panel with digital floor position indicator, emergency light, emegency alarm and serial communication system with automatic service device and synchronised leveling including maintenance, repair and replacement of defective parts ( Parts which will be measured and paid separately under relevant items). Inclusive of examination of all safety devices speed governors at fixed periodicity as per requirement, Comducting all laid down safety tests at specified period by qualified and skilled personnel. The lift is required to be serviceable 24 hours round the clock. Any defect noticed during maintenance period shall be attended immediately without any inconvenience to medical authorities, doctor's patients and visitors complete all as specified and directed.[Note :- All the spares/components required for the repair shall be measured and paid separately here-in-after as supply only rates].For item No 1 & 2: The comprehensive maintenance work of lift shall be carried out by approved equipemnt manufacturer only and item shell be executed after the completion period of comprehensive maintenance under the existing maint contract. |
| 3 | M&L in replacement of voice card for stretcher lift & Passanger lift complete all as specified and as directed |
| 4 | M&L in replacement of relay card for stretcher lift & Passanger lift complete all as specified and as directed |
| 5 | M&L in replacement of fuse card for stretcher lift & Passanger lift complete all as specified and as directed |
| 6 | M&L in replacement of SMPS 12 V (switched mode power supply ) for stretcher lift & Passanger lift complete all as specified and as directed |
| 7 | S & F Black electrically insulated rubber mat 6 mm thick all as specified and as directed by the Engr-in-Charge |
| 8 | S & F Black autistatic flooring 2 mm thick all as specified and as directed by the Engr-in-Charge |
| 9 | S & F in repairs for ventilation fan to fall ceiling by making a opening/cut to fall ceiling and fix it with necessery control wiring and protection grill all as specified and as directed by the Engr-in-Charge |
| 10 | M&L in replacement of travelling cable 24 core 1 sqmm multistranded copper cable (suitable for stretcher and passenger lifts) complete all as specified and as directed. |
| 11 | Supply only \\"Conractor 9 Amps (Siemens make) \\" complete all as specified and directed. |
| 12 | Supply only \\"MCB SP 16 Amps to match the exising complete all as specified and directed. |
| 13 | Supply only \\"Gear oil\\" complete all as specified and directed. |
| 14 | Supply only \\" Car main steel wire rope 13 mm dia\\" complete all as specified and as directed |
| 15 | Supply only \\" steel wire rope U clip\\" complete all as specified and as directed |
| 16 | Supply only \\"O/E/N realy 214 volt DC\\" complete all as specified and directed. |
| 17 | Supply only \\"Two phase transformer (415 volts AC)\\" complete all as specified and directed. |
| 18 | Supply only \\" controller SSP 440 V \\" complete all as specified and directed.\\" |
| 19 | Supply only \\"main controller mother board\\" complete all as specified and directed.\\" |
| 20 | Supply only \\"Door bearing for auto door\\" complete all as specified and directed.\\" |
| 21 | Supply only \\" Door drive belt V type\\" complete all as specified and directed. |
| 22 | Supply only \\"Read switch\\" complete all as specified and directed. |
| 23 | Supply only \\" Micro Switch \\" 15A 250 Volts complete all as specified and directed. |
| 24 | Supply only \\" Landing Switch\\" complete all as specified and directed. |
| 25 | Supply only \\" COP switch\\" complete all as specified and directed. |
| 26 | Supply only \\" door drive \\" complete all as specified and directed. |
| 27 | Supply only \\" floor sensor \\" complete all as specified and directed. |
| 28 | Supply only \\" auto door contact \\" complete all as specified and directed. |
| 29 | Supply only \\" auto door motor \\" complete all as specified and directed. |
| 30 | Supply only \\" controller fuse card \\" complete all as specified and directed. |
| 31 | Supply only \\" controller rectified card \\" complete all as specified and directed. |
| 32 | Supply only \\" controller realy 110v to 220v \\" complete all as specified and directed. |
| 33 | Supply only \\" main guide shoes 6 mm to 10 mm \\" complete all as specified and directed. |
| 34 | Supply only \\" brake coil 100 v to 220 v DC/AC \\" complete all as specified and directed. |
| 35 | Supply only \\" automatic door sensor unit\\" complete all as specified and directed. |
| 36 | Maerial and labour for preparation of old painted mild steel (MS) surfaces of passenger and stretcher lift ( all inside and out side door of the lift) including electric motor, floor of lifts and cabin fan of the lifts, puttying steel surfaces to obtain smooth and even finish and applying two coats of synthetic enemel paints by brush application complete all as specified and directed. |
| 37 | M&L for Servicing of Long Travel 4 Nos Motor alongwith 4 Nos Gear Box complete dismantling, overhauling, gear oil change and fillup complete all as specified and as directed by the Engr-in-charge |
| 38 | M&L for Servicing of Cross Travel motor & gear box assembly by greasing & gear oil change and fillup complete all as specified and as directed by the Engr-in-charge |
| 39 | M&L for Hist motor, gear box grasing & oil change and fillup complete all as specified and as directed by the Engr-in-charge |
| 40 | M&L for Cross travel trolly full checking and greasing complete all as specified and as directed by the Engr-in-charge |
| 41 | M&L for servicing of break assembly and replacement of Leather of LT brake complete including of oil filling all as specified and as directed by the Engr-in-charge |
| 42 | M&L for sevicing, tightness,cleaning of Pannel Board 4 Nos Drive all contractor all relay checking complete all as specified and as directed by the Engr-in-charge |
| 43 | M&L for Guarder repair in, long travel & testing complete all as specified and as directed by the Engr-in-charge |
| 44 | M&L for Long travel all guarder checking and grinding as required complete all as specified and as directed by the Engr-in-charge |
| 45 | M&L for Cross travel guarder checking complete all as specified and as directed by the Engr-in-charge |
| 46 | S/F s*2000VVVF AC drive crank No. 2 change 400 volts complete all as specified and as directed by the Engr-in-charge |
| 47 | M&L for Cross travel motor rewinding 3 phase, 5 HP DC convert 110 V make-bharat bijlee 2 Nos bearing chane complete all as specified and as directed by the Engr-in-charge |
| 48 | M&L for rechecking, callibration and minor repair to pendent push button assembly complete all as specified and as directed by the Engr-in-charge. |
| 49 | M&L for Timer Off relay complete all as specified and as directed by the Engr-in-charge |
| 50 | M&L for Contractor 9 Amps. Cap set of 4 Nos complete all as specified and as directed by the Engr-in-charge. |
| 51 | M&L for MCB Single pole 16 Amps cap complete all as specified and as directed by the Engr-in-charge. |
| 52 | M&L for HRC fuse 32 Amps cap complete all as specified and as directed by the Engr-in-charge Please Enable Macros to View BoQ information |
| 53 | M&L for HRC fuse 32 Amps cap complete all as specified and as directed by the Engr-in-charge Please Enable Macros to View BoQ information |