| 1 | M&L in replacement of sub main wiring from street light to junction box with PVC insulated and PVC Round Sheathed 3-core Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, 1.5 sqmm in and including heavy grade PVC conduit and its accessories with fixing arrangements on pole surface, wall, ceiling etc complete all as specified and directed by Engr-in-chargeNote : One run of 3-core Copper Conductor (flexible) industrial cable ,one run of PVC conduit together taken as one length for measuring unit length. Make: Havells Cat part No. WHMFDSKG31X5 or equivalent in any approved make. |
| 2 | M&L in replacement of sub main wiring from street light to junction box with PVC insulated and PVC Round Sheathed 3-core Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, 2.5 sqmm in and including heavy grade PVC conduit and its accessories with fixing arrangements on pole surface, wall, ceiling etc complete all as specified and directed by Engr-in-chargeNote : One run of 3-core Copper Conductor (flexible) industrial cable ,one run of PVC conduit together taken as one length for measuring unit length. Make: Havells Cat part No.WHMFDSKG32X5 or equivalent in any approved make. |
| 3 | S&F in replacement service wire 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sqmm x 2 Core nominal cross section complete all as specified and directed by Engr-in-charge |
| 4 | M&L in replacement of LT UG cable 16 Sqmm x 4 Core 1100 Volts grade XLPE insulated , armored, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including, lugs/ thimbles/ ferrules including making connection, testing complete all as specified and as directed by Engr-in-charge |
| 5 | M&L in replacement of LT UG cable 25 Sqmm x 4 Core 1100 Volts grade XLPE insulated, armored, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including, lugs/ thimbles/ ferrules including making connection, testing complete all as specified and as directed by Engr-in-charge. |
| 6 | Excavating in trenches in Hard and dense soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, laying of cable etc not exc 10 Sq mtr on plan and not exc 1.5 mtr in depth and getting out complete all as specified and directed by the Engr-in-Charge. |
| 7 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm as in soils complete all as specified and as directed by Engr-in-charge |
| 8 | Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point as in soils complete all as specified and as directed by Engr-in-charge |
| 9 | M&L for Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8cm deep before laying the cable and 15cm deep after laying and stretching the cable complete all as specified and as directed by Engr-in-charge. |
| 10 | Supplying and laying un-reinforced precast concrete cable cover Class LV, Type I, flat, size 250x150x40mm laid dry over electric cable for protection complete all as specified and directed by the Engr-in-Charge |
| 11 | M&L for PCC 1:2:4 type B-1 using 20 mm graded aggregate as in coping of poles and platform incl. necessary form work fair and finishing without using extra cement complete all as specified and as directed by Engr-in-charge. |
| 12 | Supply and laying GI Pipe light grade 50mm dia for cable protection laid in trenches or fixed on pole/wall complete all as specified and as directed by Engr-in-charge |
| 13 | Supply and fix PVC conduit pipe 25mm dia heavy duty secured to poles/wall or laid in trench at a depth of minimum 150 mm and width 150 mm inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.all as specied and as directed by Engr-in-charge |
| 14 | S&F PVC conduit pipe 20mm dia heavy duty secured to poles/wall or laid in trench at a depth of minimum 150mm and width 150mm inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and as directed by Engr-in-charge. |
| 15 | S&F in replacement GI pipe 40mm bore, light grade of 1.50 metres length, bent to shape required as in street light brackets, fixed to poles/ walls with suitable size MS clamps, nuts & bolts complete all as specified and as directed by Engr-in-charge. |
| 16 | M&L for preparation of old surface of steel pole including channels and applying two coats of aluminium paint including making five no. alternative yellow & black strips 30 cm height each (upto 1.50 metre height from top of PCC coping) & numbering to the poles with synthetic enamel paint complete all as specified and directed by the Engr-in-Charge. |
| 17 | S&F Cable junction box of size not more than 250x150x75 mm with 6-32 Amp MCB SPN and bus bar fixed along the wall/pole complete including mounting arrangements including removing the existing defective looping box complete all as specified and as directed by Engr-in-charge. |
| 18 | S&F in replacement MCB TPN, 415V, 50Hz, 32Amps complete all as specified and directed by Engr-in-charge |
| 19 | S&F in replacement of MCB SPN, 220V , 50Hz , 32Amps complete all as specified and directed by Engr-in-charge |
| 20 | S&F in replacement of MCB SP, 220V , 50Hz , 5-32Amps for street light complete all as specified and directed by Engr-in-charge |
| 21 | S&F in replacement post top lantern LED 45W, 220v, 50Hz , IP>65, CCT 6500K/3000K environmental friendly,long life aesthetically design with symmetrically light distribution, spun aluminium landscale luminaire with high power LEDs as light source with clear cover including wiring with 1.5 sq mm PVC insulated standed copper conductor throught existing conduit/casing capping and conectting the lights with the nearest street light feeders/switch control as per site requirment complete all as specified and as directed by Engr-in-charge.Make:- Havells Cat part No. RUBYPT45WLED757PSYM TOPC or equivalent in Philips Cat part no BGP200 LED45 CW PSU GR CPC SPD or equivalent in CROMPTON Cat part no. CBP-610-40-57-SL-CA-NBK. |
| 22 | S&F in replacement 10 Watt LED Disc shaped Bollard Light (Warm White in colour) in Extruded Aluminum section fitted with low glare PC diffuser in complete half section with IP 65 protection including foundation nut bolts and making connections complete all as specified and as directed by Engr-in-charge.Make : Havells Cat part no. UFOBLS10WLED830PSYM TOPC or equivalent in Jaquar Cat part no OBL-GRY-LBLDDSC010XW or equivalent in Philips Cat part no. Philips pylon Pedestal 58171. |
| 23 | S&F in replacement 10 Watt LED Conical shaped Bollard Light (Cool Day in colour) in Extruted Aluminum section fitted with low glare PC diffuser in complete half section with IP 45 protection complete including foundation nut bolts etc & making connections complete all as specified and as directed by Engr-in-charge.Make : Havells Cat part no. CONEBLS8WLED857PSYM TOPC or equivalent in CROMPTON Cat part no LBLTW-10-CDL or equivalent in Jaquar Cat part no. LBLDCON010XW. |
| 24 | S&F in replacement of 8W/10 Watt LED Conical shaped Bollard Light (Warm White in colour) in Extruted Aluminum section fitted with low glare PC diffuser in complete half section with IP 65 protection complete including foundation nut bolts & making connections complete all as specified and as directed by Engr-in-charge.Make :Havells Cat part no. CONEBLS8WLED830PSYM TOPC or equivalent in CROMPTON Cat part no LBLTW-10-WW or equivalent in Jaquar Cat part no. LBLDCON010XW. |
| 25 | S&F in replacement of 50Watt LED Tri colour Bollard Light outdoor type, weatherproof in die-cast Aluminum pipe housing with cylindrical apal/MS powder-coated body fitted with low glare PC diffuser in complete half section with IP 65 protection suitable for pathway/ landscaping lighting with tricolor and tratic white output switch complete including foundation nut bolts etc & making connections complete all as specified and as directed by Engr-in-charge.Make :Bajaj Cat part no. BLSLC 50W LED TRI 3M or equivalent in Havells/Phillips/Jaquar. |
| 26 | S&F in replacement LED Flood light fitting 50watt 5000k, 125 lm/w, natural white, IP>66, grey powder coated die cast aluminium housing , inbuilt energy efficent surge protected electronic driver with toughtened glass including all connected accessories complete all as specified and as directed by Engr-in-charge. |
| 27 | S&F in replacement LED Flood light fitting 70watt 5000K/3000K, IP>66, grey powder coated die cast aluminium housing, inbuilt energy efficent surge protected electronic driver, with all connected accessories complete all as specified and as directed by Engr-in-charge. |
| 28 | S&F in replacement LED Flood light fitting 100watt 5000K/3000K, IP>66, grey powder coated die cast aluminium housing, inbuilt energy efficent surge protected electronic driver, with all connected accessories complete all as specified and as directed by Engr-in-charge. |
| 29 | S&F in replacement High power LED Street light fitting 35 watt 5000K/3000K, IP>66 , IK>07 grey powder coated die cast aluminium housing, inbuilt energy efficent surge protected electronic driver, with all connected accessories complete all as specified and as directed by Engr-in-charge. |
| 30 | S&F in replacement High power LED Street light fitting 70 watt 5000K/3000K, IP>66 , IK>07 grey powder coated die cast aluminium housing, inbuilt energy efficent surge protected electronic driver, with all connected accessories complete all as specified and as directed by Engr-in-charge. |
| 31 | S&F Digital timer switch for 220V AC-240V AC with weekly/ Daily programming modes having maximum switching capacity of 2300 Watt suitable for mounting on DBs and LT Panels complete all as specified and directed by Engr-in- Charge.Make:- Havells Cat part No.DHTJW01016 or equivalent in L&T/Schneider. |
| 32 | S&F 5Watt LED (Warm White) spike light using COB LED as light source Environmental friendly, compact, light weight, energy saving, IP 65/66 complete with all accessories including making connection with 1.5 sqmm 3 core flexible copper cable complete all as specified and as directed by Engr-in-charge. Make : Model No. IRVINESPS5WLED830PSYMTG of Make Havells or equivalent Jaquar code-0SKGRY LSPK03R104XW or HPL cat No-HPLLEDSP0660. |
| 33 | S&F Cable Junction Boxes IP 66/67/69 (Black) “weather proof” for outdoor installation (with knockouts for cable entry) suitable for cable size 4 Sqmm to 10 Sqmm of dimension 130x180x77mm with terminals complete all as specified and as directed by Engr-in-charge. Make : Hensel Model No. KF 1010 B/ Rittal/Siemens/Schneider/ Universal Switch Gear. |
| 34 | S&F LED based tri-colour Kerb Light (Red/White/Green) suitable for outdoor use, comprising high efficiency LEDs with minium IP-65 protection, mounted flush with kerb stone/ pavement, complete with housing, suitable for 230V AC single phase supply, including necessary fixing arrangement, wiring connection complete all as specified and as directed by Engr-in-charge. |
| 35 | Note : Deduction for amount of Rs. 33,720.00 as listed in Schedule 'A' Part-II (Schedule of Credit) shall be made while awarding of contract. Please Enable Macros to View BoQ information |