| 1 | Excavating in trenches not exc 1.5m wide and n.exc 1.5 m in depth, for foundations, etc, or for shafts, wells, cesspits, manholes, pier holes, etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 3 | Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed. |
| 4 | Materials and Labour for plain cement concrete (1:4:8) type D-2, using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed. |
| 5 | Materials and Labour for plain cement concrete (1:3:6) type C-2, using 40mm graded stone aggregate as in surface channel and drain including necessary formwork complete all as specified and as directed. |
| 6 | Materials and Labour for plain cement concrete (1:2:4) type B-0, using 12.5mm graded stone aggregate as in benching, coping, kerb and the like including necessary formwork complete all as specified and as directed. |
| 7 | Materials and Labour for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. all as specified and as directed. |
| 8 | Materials and Labour for precast reinforced cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces etc, any thickness, placed in position and set in cement mortar 1:6 complete all as specified and directed. (Note: Steel reinforcement shall be measured & paid separately) |
| 9 | Materials and Labour for TMT bars 10 mm dia and over, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 10 | Supply & fixing Mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to steel trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165. |
| 11 | Materials and labour for brick work with sub class 'B' burnt clay bricks straight or curved on plan exc 6 meter mean radius built in cement mortar 1:4 complete all as specified and as directed. |
| 12 | Materials and labour for rendering 15mm thick in cement mortar (1:4) on other than fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, WPC shall be mixed with morter as per manufacturers instruction and as directed, complete all as specified and directed. (Note: WPC shall be measured and paid separately as supply only) |
| 13 | Supply only liquid Water Proofing Compound of approved make. |
| 14 | Supplying and fixing 150 mm dia uPVC roof gutter complete all as specified and directed. |
| 15 | Supplying and fixing 150 mm dia uPVC coupler for roof gutter system complete all as specified and directed. |
| 16 | Supplying and fixing 150 mm dia uPVC elbow 90 degree for roof gutter system complete all as specified and directed. |
| 17 | Supplying and fixing 150 mm dia uPVC elbow 90 degree with running outlet 150x110 mm for roof gutter system complete all as specified and directed. |
| 18 | Supplying and fixing 150 mm dia uPVC external end cap for roof gutter system complete all as specified and directed. |
| 19 | Supplying and fixing 150 mm dia uPVC internal end cap for roof gutter system complete all as specified and directed. |
| 20 | Supplying and fixing 150 mm dia uPVC gutter support bracket for roof gutter system complete all as specified and directed. |
| 21 | Supplying and fixing 150 mm dia uPVC running outlet for roof gutter system complete all as specified and directed. |
| 22 | Supplying and fixing 150 mm dia uPVC stop end outlet for roof gutter system complete all as specified and directed. |
| 23 | Supplying and fixing 150 mm dia uPVC flexi clip for roof gutter system complete all as specified and directed. |
| 24 | Materials and labour for concrete bed to 110 mm dia drain pipes using PCC (1:4:8) type D2, using 40 mm graded crushed stone aggregate, including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed. |
| 25 | Supply and fixing 300 mm dia Reinforced concrete pipes, class NP3, laid and jointed complete with collars , complete all as specified and directed. |
| 26 | Supply and fixing PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed. |
| 27 | Supply and fixing PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints fixed to walls with suitable size clamps, complete all as specified and directed. |
| 28 | Supply and fixing PVC (SWR) bends any radius 110mm bore without access door, complete all as specified and directed. |
| 29 | Supply and fixing PVC (SWR) branch piece (Single Y) equal or unequal 110mm bore with access door, complete all as specified and directed. Please Enable Macros to View BoQ information |