| 1 | supply , fabrication & erection of pre-fabricated steel STRUCTURE / building is made up of primary members,secondary members, connections,roof sheeting,wall sheeting, sheeting fasteners,sealer,closures,ridge cap,flashing and trim,gutters and down spouts as in Parking shed for specialist vehicles complete all as as specified and shown on drawings. |
| 2 | SCH 'A' PART-II to VII :Note: These schedules are pre-priced by MES and the rate indicated against the respective schedule under Col 6 signifies this fact only. The tenderer is required to quote their lumpsum amount under col 13 against item of works catered under these schedule . |
| 3 | Lumpsum price inserted under col 13 by the tenderer for SITE CLEARANCE, EARTH WORK EXCAVATION AND DEVELOPMENT as listed in Schedule ‘A’ Part II representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part II |
| 4 | Lumpsum price inserted under col 13 by the tenderer for BUILDING/STRUCTURE( UPTO PLINTH LEVEL) as listed in Schedule ‘A’ Part III representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part III |
| 5 | Lumpsum price inserted under col 13 by the tenderer for Road/Path/Culvert as listed in Schedule ‘A’ Part IV representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part IV |
| 6 | Lumpsum price inserted under col 13 by the tenderer for Area Drainage as listed in Schedule ‘A’ Part V representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part V |
| 7 | Lumpsum price inserted under col 13 by the tenderer for Retaining Wall as listed in Schedule ‘A’ Part VI representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part VI |
| 8 | Lumpsum price inserted under col 13 by the tenderer for Internal Electric Supply as listed in Schedule ‘A’ Part VII representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part VII |
| 9 | SCHEDULE 'A' PART-VIII (MISCELLANEOUS B/R AND E/M Items)Note: This schedule is not pre-priced by MES and the rate indicated as \\"Rs 0.00\\" under Col 6 signifies this fact only.The tenderer is required to quote their rate under col 13 against item of works catered under this schedule . |
| 10 | ROAD / PATH / CULVERT |
| 11 | M & L Preparing surfaces by brushing with wire brushes for removing caked mud etc. Weeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc Applying evenly a prime coat of Cationic Bitumen Emulsion SS1 confirming to IS: 8887 at a rate application of 0. 7-1 kg/sqm on surface of WMMIVVBM as specified in Table 500-3 of MoRTH specification for road and bridge works 2013, using mechanical sprayer complete all as specified and directed . |
| 12 | M & L Applying evenly a tack coat of Cationic Bitumen Emulsion (RS-1) conforming to IS: 8887 at a rate of application of 0.2-0.3 kg/sqm on bituminous surface/WBM surfaces as specified in Table 500-5 of MaRTH specification for road and bridge works 2013, using mechanica sprayer after cleaning of existing surface complete all as specified and directed. |
| 13 | AREA DRAINAGE |
| 14 | Extra for forming fair finished to drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped end etc complete all as specified and directed. |
| 15 | INTERNAL ELECTRIC SUPPLY |
| 16 | Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 17 | Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant with driver and lamp complete all as specified and directed. |
| 18 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 19 | Excavating in trenches n. exc. 1.5 m. wide and n. exc. 1.5 m. in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pire holes, etc. n. exc. 10 sqm on plan and not exc. 1.5 m. in depth and getting out in soft/loose soil complete all as specified and directed. |
| 20 | Returning filling including spreading levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed. |
| 21 | Removing excavated soil not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point in soil complete all as specified and directed. |
| 22 | Sullpy, laying ,connecting and testing LT XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables heavy duty with aluminium conductor 1100 volts grade of size 4 core 16 Sqmm complete all as specified and directed. |
| 23 | Supply and laying unreinforced precast concrete cable cover, class, LV, type 1 flat, size 250mm x 150mm 40mm, ISI marked complete all as specified and directed. |
| 24 | Supply and spreading dry coarse sand in trenches for protection of underground electric cable, spread in uniform 23 cm thickness and punned down gently to 18cm complete all as specified and directed.Note: punned thickness shall be measured and paid. |
| 25 | Supply and fixing 8 Mtr Long Hot Dip Galvanised Street Light Octagonal Pole with Foundation type Base Plate and Foundation Bolts and additional structural steel as reqd, dimentions of Pole as Top Diameter - 70 mm, Bottom Diameter- 130 mm, Section Length - 8000 mm, Thickness - 3 mm, Foundation type Base Plate (200 x 200 x 16 mm), Foundation Bolts - 4 Nos 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projects bolt length 100 mm , with Single type arm bracket 1500 mm long , top dia 70 mm , suitable for LED Street Light fitting. The Pole shaft shall have octagonal cross section and continuously tapered with single longitudinal welding complete all as specified and directed. |
| 26 | M&L for cement concrete in foundation, filling mass concrete type-C2, 1:3:6, (40mm graded aggregate) for pole foundation & finishing the surface even & smooth without using extra cement incl necessary formwork complete all as specified and directed. |
| 27 | M & L for disconnecting and dismantling of existing street light pole including PCC and street light of any size complete all as specified and directed. Please Enable Macros to View BoQ information |