| 1 | Civil Works |
| 2 | 60.2.3Bailing out water using pump above 5 HP and Up to 10 HP-Bailing out water withengine and pump set above 5HP and up to 10HP, including conveyance to site anderection,cost of fuel, lubrication oil and other stores, pay of staff etc complete |
| 3 | 2.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge.All kinds of soil |
| 4 | 2.7.1Earth work in excavation by mechanical means (Hydraulic excavator )/ manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.Ordinary rock |
| 5 | 2.26.1Extra for every additional lift 1.5 m or part there of in excavation / banking excavatedor stacked materials.All kinds of soil |
| 6 | 2.9.1Excavation work by mechanical means (Hydraulic excavator) / manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soils as directed,within a lead of 50 m.Ordinary rock |
| 7 | 60.5.3DOWEL BARS - Supplying and Providing MS dowel bars of size 25 mm dia of 2.0mlong (1m in rock and 1m in concrete ) including drilling holes of 30mm dia and fillingthe gap with cement grout( 0.50kg/each) etc complete |
| 8 | 4.1.2Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | 5.33.1.2Providing and laying in position ready mixed or site batched design mix cementconcrete for reinforced cement concrete work; using coarse aggregate and fineaggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 toaccelerate / retard setting of concrete, to improve durability and workability withoutimpairing strength; including pumping of concrete to site of laying, curing, carriagefor all leads; but excluding the cost of centering, shuttering, finishing andreinforcement as per direction of the engineer-in-charge; for the following grades ofconcrete. Note: Extra cement up to 10% of the minimum specified cement content indesign mix shall be payable separately. In case the cement content in design mix ismore than 110% of the specified minimum cement content, the contractor shall havediscretion to either re-design the mix or bear the cost of extra cementAll work upto plinth levelConcrete of M30 grade with minimum cement content of350 kg /cum |
| 10 | 5.33.2.1Providing and laying in position ready mixed or site batched design mix cementconcrete for reinforced cement concrete work; using coarse aggregate and fineaggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 toaccelerate / retard setting of concrete, to improve durability and workability withoutimpairing strength; including pumping of concrete to site of laying, curing, carriagefor all leads; but excluding the cost of centering, shuttering, finishing andreinforcement as per direction of the engineer-in-charge; for the following grades ofconcrete. Note: Extra cement up to 10% of the minimum specified cement content indesign mix shall be payable separately. In case the cement content in design mix ismore than 110% of the specified minimum cement content, the contractor shall havediscretion to either re-design the mix or bear the cost of extra cementAll work above plinth level upto floor V levelConcrete of M25 grade with minimumcement content of 330 kg /cum |
| 11 | 5.35Add for using extra cement in the items of design mix over and above the specifiedcement content therein |
| 12 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more |
| 13 | 5.22A.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo - MechanicallyTreated bars of grade Fe-500D or more |
| 14 | 5.9.1Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete |
| 15 | 5.9.3Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform |
| 16 | 5.9.5Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers |
| 17 | 5.9.6Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts |
| 18 | 5.9.7Centering and shuttering including strutting, etc. and removal of form for:Stairs,(excluding landings ) except spiral - staircases) |
| 19 | 7.1.1Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarsesand) |
| 20 | 10.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same with necessary stainless steel nutsand bolts complete, i/c fixing the railing with necessary accessories & stainless steeldash fasteners, stainless steel bolts etc., of required size on the top of the floor or theside of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only weight of stainless steel members shall be consideredexcluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 21 | 13.46.1Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm) |
| 22 | 11.20.1Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard,jointed with neat cement slurry mixed with pigment to match the shade of tiles,including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar1:4 ( 1 cement : 4 coarse sand).Light shade pigment using white cement |
| 23 | Structural Works |
| 24 | 85.101Supply of MS plates confirming to IS 2062GrB including cost of conveyance charges |
| 25 | 85.102Supply of MS Tees, Angles, Joists, ISMB, ISMC confirming to IS2062GrA/Bincluding cost of conveyance charges |
| 26 | 85.103Supply of MS checquered plates including cost of conveyance charges |
| 27 | 85.106Supply of MS flats including cost of conveyance charges |
| 28 | 85.108Fabrication , erection and commissioning of Structural Steel Embedded parts inIS2062 Grade and accessories as per approved specifications, drawings and directionsof deptl officer at site including cost of labour , machinery , incidental and handlingcharge etc complete but exculding cost of materials already supplied |
| 29 | 10.20Providing and fixing bolts including nuts and washers complete. |
| 30 | 10.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same with necessary stainless steel nutsand bolts complete, i/c fixing the railing with necessary accessories & stainless steeldash fasteners, stainless steel bolts etc., of required size on the top of the floor or theside of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 31 | 16.70.2Providing and fixing G.I. chain link fabric fencing of required width in mesh size50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers asrequired complete as per the direction of Engineer-in- charge.Made of G.I wire of dia4 mm. PVC coated to achieve outer dia. not less than 5 mm in required colour andshade |
| 32 | 13.52.1Finishing with Epoxy paint (two or more coats) at all locations prepared and appliedas per manufacturer's specifications including appropriate priming coat, preparationof surface, etc. complete.On steel work |
| 33 | OD412677/2025-2026Supplying, Cutting and erecting of 26 mm dia Galvanised Steel wire rope with 6x36Construction, Galvanized Steel Core, RHO Lay, Tensile : 1960 N/mm2, Min.Breaking Force: 472 kN |
| 34 | OD203477/2025-2026Vetting of Design and Drawings by an accredited Govt. Agency. (Actual to be paidon Submission of Bill) |
| 35 | Preparation of Bund |
| 36 | 60.5.3DOWEL BARS - Supplying and Providing MS dowel bars of size 25 mm dia of 2.0mlong (1m in rock and 1m in concrete ) including drilling holes of 30mm dia and fillingthe gap with cement grout( 0.50kg/each) etc complete |
| 37 | 60.65Providing Z steel sheet pile of size 400x185x7.5/8.5 driving down vertically in linesand levels interlocking with adjacent piles with suitable pile driving unit and allaccessories including all labour hire charges etc. complete and as per the directions ofdepartmental officers at site. |
| 38 | 60.1.1RING BUND Type-I-Putting up ring bund as per approved shape 2.5m bottom width,1m top width using empty gunny/polythene bags filled with earth placed in 2 rows at0.6m apart and filled in between with puddle clay to form bund for an average height2.00m including labour dismantling the bund after completion of the work etc.complete. |
| 39 | Electrification Works |
| 40 | 90.14.1.2Fabrication, supply, conveyance, installation testing and commissioning of floor orwall mounting, dust and vermin proof, cubicle type MV panel board comprising ofthe following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assemblyas per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approveddesign and requirement, with front and rear access facility, bus bar chambers, hingeddoors for all switch gear compartments, earthing the doors using 4 sq mm braidedcopper conductor, providing necessary cut-outs for mounting meters, relays,indication lamps, bus bar interconnection etc, detachable covers for bus bar chamberand cable alley, powder coating the assembly after subjecting to 7 tank process etc asrequired. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted anglesetc shall not be used for the fabrication of panel assembly. The measurments will betaken the area of the complete sheets used for panel board including partitions,folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCAsheet, powder coated (excluding base frame) |
| 41 | 90.14.3.2Supply and providing heavy duty 'A' section neoprene gasket in the panelboardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet |
| 42 | 90.14.4Supply and fabrication conveyance and installation of base frame of panel boardusing 75 x 40 mm rolled steel channel (ISMC) |
| 43 | 90.14.7Supply and providing copper earth bus in the panel board |
| 44 | 2.2.1Providing and fixing following rating and breaking capacity MCCB withthermomagnetic release and terminal spreaders in existing cubicle panel boardincluding drilling holes in cubicle panel. making connections. etc. as required.100 A, 16KA |
| 45 | 1.17.1Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x1.5 sq. mm |
| 46 | OD413828/2025-2026Supply and Installation of a Digital timer, operating at 220-250 VAC, 50Hz, with25A/1.5HP Capacity. It Features 5 On/Off Program settings for daily and weeklyschedules, along with manual start, ON delay, and OFF delay settings. Equipped witha high- precision, industrial- grade chip and strong anti- interference capabilities, thetimer can automatically turn on and off the power supply of various electricalequipment according to the time set by the user. The controlled objects can includestreet lights, light boxes, neon lights, and high/ mini mast systems. It also includes asufficient battery backup for time memory in case of power failure, and comes withsuitable fittings for use in a distribution box or MV panel with FRLS PVC insulated5mm single core cable suitable for control wiring towards contactor |
| 47 | OD413829/2025-2026Supply and installation of a double pole 25A Contactor, rated for 220-250 VAC.50Hz operation. It can control treet lights, light boxes, neon lights, high/mini mastsystems and induction loads |
| 48 | OD413830/2025-2026Supplying and installation of an IP20 Surge Protective Device (SPD) with suitablefittings for a distribution box or MY panel. Specifications include: Voltage protectionLevel (Up), Nominal Voltage: 230V. UOC, LOKV.L-N: 7KV, L-PE: 7KV, NPE:7KV Nominal Discharge Current (8/20& micros): 10kA. Total DischargeCurrent (8/20& micros): 60kA. Response Time & lt 35ns. AmbientTemperature (Ta):- 10 to 55& degC |
| 49 | OD413831/2025-2026Supply and fixing HRC fuse base of 32A using suitable nut and bolt. 32 A 2-wayneutral links mounted on DMC/SMC base |
| 50 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 51 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps |
| 52 | 2.14.2Supplying and fixing following rating, double pole, (single phase and neutral),240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 53 | 5.2Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc.(but without charcoal/ coke and salt) as required |
| 54 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10SWG |
| 55 | 90.16.4.2Supply and clamping the following sizes of strips on surface of wall / parapet/existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted orheavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good thedamages, colour washing etc. as required ( for vertical run).25 x 3 mm GI strip |
| 56 | 90.16.5.3Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.3.15 mm (10 SWG) |
| 57 | 90.6.5.6Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conformingto IS 694 part I 1960 in the existing surface / recess conduit as required includinggiving necessary connections of the following sizes.2 core 4.00 sq mm |
| 58 | OD413789/2025-2026Supply and installation of DMX controller (Signal controller for processing differentdesigns) |
| 59 | OD413790/2025-2026Supply and installation of 12V switched mode power supply (SMPS are placed within corresponding intervals for boosting the 12V power supply) |
| 60 | OD413791/2025-2026Supply and installation of Aluminium frame profile (IP66) |
| 61 | OD413792/2025-2026Supply and installation of RGB profile light strip (in a strip contains 240 LEDs permetre and lights are of IP66 protected ) |
| 62 | OD413793/2025-2026Supply and installation of Terminal connector (Each connectors are of IP66protected) 12 module moulded plastic box on surface |
| 63 | OD413794/2025-2026Supply and installation of junction box (IP66) for fitting SMPS in for providing 12Vpower supply |
| 64 | OD413795/2025-2026Supply and installation of IP 65/66 rated cable gland 4 sqmm |
| 65 | OD413796/2025-2026Supply and installation of Foot light with clamping, connectors and JB (All IP 66)along with required accessories |
| 66 | OD413797/2025-2026Supply and installation of T connectors (IP66) |
| 67 | Applying Cardium Compound to both sides of wire rope including all materials, labour and incidental expenses- 643.50m |
| 68 | Supply, providing and Installation of accessories TURN BUCKLE-JAW & JAW(BTJJ-16220 OR EQUIVALENT), SCREW PIN ANCHOR SHACKLE(7/8\\"), Pulley, Cotter Pin, Aluminium Standard Ferrule, 28 mm-;T HIMPLE, Fasteners, Rope Clamps, etc. Complete for Erection and Comissioning of bridge |
| 69 | EXCLUSIVE OF GST |
| 70 | Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL |
| 71 | 2:Rate should be inclusive of Insurance,Transportation, delivery and installation cost for all items |
| 72 | 3.Rate should be Exclusive of GST. |
| 73 | 4.Work should be executed as per DSR/PWD specification and direction of Engineer at site. |
| 74 | 5.CEMENT: Make use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference. |
| 75 | 6.RCC: (Assessment of strength of concrete by Cube testing at Approved Govt labs as per IS) Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference. |
| 76 | 7.STEEL REINFORCEMENT: Make: Tata,Vaishak, SAIL, JSW or eq primary make in the order of preference |
| 77 | 8.CENTERING & SHUTTERING: (Centering and shuttering for different category of work may be considered separately.) |
| 78 | 9.ELECTRICAL: Note: Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately. |
| 79 | Make of Electrical equipments/materials |
| 80 | All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification |
| 81 | MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent |
| 82 | Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD |
| 83 | Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent |
| 84 | Cable Glands & Sockets - REPUTED MAKE , Cosmos |
| 85 | Indicating Lamps - TEKINIC/RISHUB/STC, L&T, Schneider or equivalent |
| 86 | 10. STEEL WORK G.I.PIPE: Make: JINDAL, Tata or eq. primary make in the order of preference. |
| 87 | 11.ALUMINIUM WORK: Make: INDAL, JINDAL in the order of preference and prior sample approval from KEL, Client |
| 88 | 12.Rigid PVCPipes/Casing & Capping - A-ONE/REPUTED MAKE with ISI , Precession, Balco, GEO |
| 89 | 13. ACRYLIC SMOOTH EXTERIOR PAINT/ SYNTHETIC ENAMEL PAINT/WHITE CEMENT BASED PUTTY/ CEMENT PRIMER: Make: Asian, Berger, Nerolas or eq. in the order of pref. Please Enable Macros to View BoQ information |