| 1 | NS Items |
| 2 | Providing and fixing of Profile light of size 35 x 30mm with aluminium casing of 4500 k including cost of driver complete with all respect |
| 3 | Providing and fixing of LED Lights LED IP-65 flood light fixture made of die cast Aluminium housingfitted with toughened glass. (With LED’s RGB of 50 W including driver complete in all respect as perentire satisfaction of engineer incharge |
| 4 | Careful removal of existing FRP/Asthadhatu statue of and weight approx. 35ton. from itscurrent pedestal, including: providing and fixing working platforms/scaffolding,disconnecting existing fasteners/anchors, cutting away old grout if required, safe loweringusing chain blocks/boom lift/crane as required, tagging and securing all looseparts/accessories, protection of surfaces with padding/blankets, site clearing and stacking forloading Inclusive: All tools and plants (TandP), scaffolding, safety gear (helmets, lifelines,harnesses), barricading, traffic/safety management, insurance and third-party liability, anddisposal of dismantled minor debris. : Transportation, repair/refinish, re-installationcomplete in all respect as per entire satisfaction of engineer incharge |
| 5 | Providing, fabricating, supplying and fixing Krishna–Arjun Rath sculpture of approximate size30’-0” (L) × 23’-0” (H), complete with detailed artistic modelling of figures, chariot, horses andaccessories, made in FRP / fibre-glass reinforced resin over MS armature (or equivalentapproved material), including surface preparation, finishing, painting with weather-resistantPU/acrylic paints, textures and detailing complete in all respect as per the direction ofengineer in charge. |
| 6 | Providing and fixing of Rebaring of 12 mm dia of 200 mm depth Hilti Chemical Re-500 V4 inExisting RCC Structure as specified in Drawing complete in all respect as per entiresatisfaction of Engineer- in Charge |
| 7 | Providing and fixing Golden finish SS letters made from SS 304 grade, with back acrylic sheetand inbuilt LED lighting system, complete in all respects. The letters shall be fabricated withprecision cutting, smooth edges, golden PVD / electroplated finish, and suitable acrylicbacking for uniform light diffusion.The item includes supply and installation of LED lights, internal wiring, drivers, connectors,mounting framework, fixing on the structure, alignment, testing, and commissioning. Thesystem shall be complete with warranty of 2 years for LED lights and power supply...“???? ?????”– Letter height 48` (Two sets)“???? ????? ????? ??????????? ???????????” – Letter height 30` (Two sets) complete in all respect as per thedirection of engineer in charge |
| 8 | Providing, fabricating, supplying and fixing new decorative Chatri in FRP (Fiber ReinforcedPolymer) over Geeta Dwar as per approved architectural design and existing size, includinginternal structural supporting framework, moulded ornamental detailing, surface preparation,approved exterior grade paint finish, necessary anchoring arrangement with anchorbolts/chemical fasteners, waterproofing treatment at junctions, lifting, placing and fixing atrequired height .The work shall also include dismantling and carefully removing the existingChatri from the top of the structure after ensuring proper safety arrangements, includingscaffolding, staging, mechanical lifting, loosening of joints, lowering to ground level,complete in all respects as per approved drawings and directions of Engineer-in-Charge |
| 9 | HSR Items |
| 10 | [10.1]Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. [Through Rate] |
| 11 | [10.42]Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. [Through Rate] |
| 12 | [11.5.4]12 mm cement plaster of mix : 4. 1:6 (1 cement: 6 fine sand) [Through Rate] |
| 13 | [11.58]Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete [Through Rate] |
| 14 | [11.6.2]15 mm cement plaster on the rough side of single or half brick wall of mix : 2. 1:6 (1 cement: 6 fine sand) [Through Rate] |
| 15 | [11.98.1]Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 1. New work (Two or more coats applied @ 1.43 litre/ 10 sqm Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm [Through Rate] |
| 16 | [24.13.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.) [Through Rate] |
| 17 | [24.13.32]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 32. 25 Sq mm 4 core (Arm.) [Through Rate] |
| 18 | [5.44]Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. [Through Rate] |
| 19 | [6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) [Through Rate] |
| 20 | [6.25.2]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 2. All works above plinth level up to floor IV level [Through Rate] |
| 21 | [6.26.1]Extra for providing richer mixes up to plinth and at all floor levels. 1. Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum) [Through Rate] |
| 22 | [6.29.2]Centering and shuttering including strutting, propping etc. and removal of form work for : 2. Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. [Through Rate] |
| 23 | [6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform [Through Rate] |
| 24 | [6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers [Through Rate] |
| 25 | [6.34.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. [Through Rate] |
| 26 | [7.22.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 2. Cement mortar 1:6 (1 cement : 6 coarse sand) [Through Rate] |
| 27 | [8.3]Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge. [Through Rate] |
| 28 | [8.9.1.5]Stone work (machine cut edges) for wall lining etc. (veneer work) up to 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : 1.5. Red sand stone - exposed face fine dressed with rough backing.30 mm thick [Through Rate] Please Enable Macros to View BoQ information |