| 1 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. a) Group C |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.a) Group C |
| 3 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. a) 3 x 1.5 sq. mm |
| 4 | b) 6 x 1.5 sq. mm |
| 5 | c) 3 x 4 sq. mm |
| 6 | d) 6 x 4 sq. mm |
| 7 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm |
| 8 | b) 25 mm |
| 9 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.a) 20 mm |
| 10 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.a) 1 or 2 Module (75mmX75mm) |
| 11 | b) 3 Module (100mmX75mm) |
| 12 | c) 6 Module (200mmX75mm) |
| 13 | d) 8 Module (125mmX125mm) |
| 14 | e) 12 Module (200 mmX150 mm) |
| 15 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 5/6 amps switch |
| 16 | b) 3 pin 5/6 amp socket outlet |
| 17 | c) Bell push |
| 18 | d) Blanking Plate |
| 19 | e) 15/16 A switch |
| 20 | f) 6 pin 15/16 A socket outlet |
| 21 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.a) 1 or 2 Module |
| 22 | b) 3 Module |
| 23 | c) 4 Module |
| 24 | d) 6 Module |
| 25 | e) 8 Module |
| 26 | f) 12 Module |
| 27 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 28 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 29 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 30 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/ 6 A modular switch, connections etc. as required. |
| 31 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. |
| 32 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 33 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 34 | Supplying and fixing following way, single pole and neutral, sheet steel, with MCB distribution board, 240 V, on surface/ recess, complete tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 12 way Double door |
| 35 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole |
| 36 | b) Single pole and neutral |
| 37 | Supplying & fixing of 300 mm sweep 1400 RPM 230 Volt 1-ph 50 Hz AC heavy duty Exhaust fan in the existing opening including making good the damage, connection, testing and commissioning etc. as reqd. |
| 38 | Providing and fixing following rating and breaking capacity and poleMCCB with thermomagnetic release and terminal spreaders inexisting cubicle panel board including drilling holes in cubicle panel,making connections, etc. as required. a)125 A,36KA,FPMCCB |
| 39 | b)200 A,36KA,FPMCCB |
| 40 | S/I/T/C of 1200 mm sweep BEE star rating energy efficient ISI marked ceiling fan capacitor type with double ball bearing suitable for operation of single phase AC supply with power Consumption of Max. 50W capable to deliver 220 CFM (min.), speed of 350 rpm (min.) i/c wiring the down rod of standard length (upto 30 cm) with 1.5 Sqmm FR PVC insulated copper conductor single core cable etc and help of steel chain approx 1 mtr x 2 nos. as reqd. (including dismantling the old fitting if any) |
| 41 | SITC of wall fan 400 mm sweep oscillating type having plastic blade complete with all accessories such as front jaali i/c connection etc. as reqd. (including dismantling the old fitting if any) |
| 42 | SITC of 250 mm non metalic vantilating fan with louvers/ shutters suitable for 230 V AC supply i/c making hole in the wall to suit the size and making good the damage, repair, connection with 3-core wire etc. as required. |
| 43 | Supplying, installation, Testing & Commissioning of LED surface mountedBatten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 5700°K /6000°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).a) 18- 22 watt |
| 44 | Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 5700°K/ 6000°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).a) 36 watt |
| 45 | Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Al armoured power cable of 1.1 KV grade of following size on wall surface/recess as reqd. a) size 3 X 16 sq. mm |
| 46 | Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg- 120deg as per the application and the project requirement deg, suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 5700°K /6000°K(As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).a) 200 watt |
| 47 | b) 100 watt |
| 48 | S/I/T/C of Starter Control panel for 3 phase motor upto 7.5 HP having DOL starter of relay range 9 to 14 Amp. on the wall mounting comprising of contactor, relay, single phase preventor, auto-manual On/Off voltage selector switch, voltmeter, ammeter, push buttons etc. as reqd. |
| 49 | Supplying & fixing Hot press moulded SMC box of size 250 x 200 x 105 mm i/c S/F Aluminium Bus Bar of suitable size i/c Phase, Neutral and Earth link, including 1 no. 6A to 32A rating 240 V 10KA \\"C\\" curve SP MCB & 1 no. earth bar, 1 no. Neutral bar, DIN rail mounting with openable hinged door on street light pole as required complete with mounting bracket/arrangement made of 5 mm thick GI flat iron etc. complete as required at site. pole/wall etc as reqd. at site i/c dismantling of existing. |
| 50 | SH:-II Routine MaintainanceRunning maintenance and operation of all EI wiring, Light points / Fan Points / Exhaust Fan Points / Call Bell Points, Light / Power Plug Points, AC Points, EDB, Main Board, Street Light Points,Fittings, Ceiling Fans, Exhaust Fans, Brass Batten / Angle Holder, Call Bells, Buzzer etc. by deputing the following experience staff including Sunday and holidays as per terms and conditions attached. ( For 15 Days in a month )Staff engaged by the contractora) Wireman cum operator : 01 No.b) Khallasi : 01 No. |
| 51 | SH :- III Servicing routine Maintenance of STAC/ WTACComprehensive routine maintenance of Window / Split type ACs units of 1.0 / 1.5 / 2.0 TR capacity units of different makes installed at various locations as per inventory attached, i/c repairing / replacement of remote, capacitor running type, all types of defective parts,gun metal taps,electronic parts ,float valve assembly excluding topping up of refrigerant in compressor, refrigeration pipe, PCB for indoor/outdoor complete as per terms and conditions, and timing as per direction of Engineer -in- charge & wherever reqd. (Note:- i) During the period of Summer Season & duration as specified by the Engineer-in-Charge ii) Maintaining of Complaints will be recorded by the agency in the AC Task/Complaint register)(6 X 8= 48 Units for 8 Months) |
| 52 | Complete servicing of WTAC/STAC/unit of 1/1.5 / 2.0 TR capacity including dismantling the AC from its existing position at various locations/grill/window cutting,washing with High pressure water spray electric machine coil cleaning with D- Scaling Chemical, drying with air blower ,oiling, greasing, of blower fans cleaning of evaporative and condensing coil with suitable chemical like coil cleaner, as required in its existing position complete etc. as required. |
| 53 | Supplying & charging of Refrigerant gas (R-22/32 as per requirement of AC unit) in the following type capacity AC units i/c leakage testing removing the leakage, pressure testing, flushing the complete system, vacuumising and gas charging complete as required. (Cost for gas & labour charges already included in the below mentioned item) (Note:- Quantity of gas filled shall be entered in Consumption Register maintained by the agency) a) In 1.5 TR WTAC/STAC capacity |
| 54 | b) In 2.0 TR WTAC/STAC capacity |
| 55 | Repairing of PCB card of 1.5/2 TR capacity WTAC/split type AC unit having following capacity after dismantaling the defective card from AC unit & refixing the same i/c connections of electrical wires/cables & thimbles connection, testing & commissioning etc. complete as required. |
| 56 | SH-IV (Minor repair of Pumpsets Work)Rewinding of following size Submersible/Mono submersible/monoblock pumpset with copper rewinding wire incl. dismantling of pumpset from site, cartage from site to work shop and return back to site, cutting the burnt winding wire (i/c credit for old winding wire) along with installation, testing & commissioning etc. as reqd. at site.a) Upto 1 HP |
| 57 | of upto 3/5/7.5/10/20 HP Mono Submersible/Sewage/ Submersible P/set along with G.I. pipe in existing well/underground tank with the help of chain pulley and tripod etc. as reqd. |
| 58 | Taking out of upto 7.5 HP Mono Submersible/Sewage/ Submersible P/set along with G.I. pipe in existing well/underground tank with the help of chain pulley block and tripod complete as reqd. |
| 59 | Comprehensive Annual Maintenance of 100 LPH capacity RO System, connected prior to water coolers i/c four mandatory services (cleaning of All Filters), repair/ replacement of all electrical and electronic spare parts and One time replacement of consumables in a year like Particulate Filter 20”, Sediment Filter 20”, Pre Carbon Filter 20” and Post Carbon Filter, UF Filter, once in a year Membrane cleaning/ replacement as if any required (Except External Pre filters), Attending complaints within 24 working hours with complete overhaulting and servicing etc. (Dismantled Shall be retained with contractor). (Qty 01 Nos.-1 job) Please Enable Macros to View BoQ information |