|
| 1 | Const. of Changing Room and Toilet |
| 2 | Boring of 25cm dia piles of double under reamed of 50cm dia of bulb and 3.50 meter depth in B.C. Soil with hand operated auger machine |
| 3 | R.C.C . Work in cement coarse sand and 20mm gauge stone gride in proportion 1:1.5:3 in piles grade beam excluding supply of reinforcement and also including supply of all material labour T&P centering and shuttering etc.DSR Code No 5.1.2 |
| 4 | R.C.C . Work in cement coarse sand and 20mm gauge stone gride in proportion 1:1.5:3 in columns excluding supply of reinforcement and also including supply of all material labour T&P centering and shuttering etc.DSR Code No 5.2.2 |
| 5 | M-150 brickwork in 1:6 cement and fine sand mortor including cost of material , labour, T&P complete DSR Code No6.1.2 |
| 6 | 4 cm thick D.P.C. in 1:2:4 cement C. sand and 13mm stone grit and waterproofing material complete DSR Code No 4.10 |
| 7 | M-150 brickwork in 1:6 cement and fine sand mortor including cost of material , labour, T&P complete in super structure DSR Code No 6.1.2+6.5 |
| 8 | R.C.C . Work in cement coarse sand and 20mm gauge stone gride in proportion 1:1.5:3 in lintel T-beam, slab excluding supply of reinforcement and also including supply of all material labour T&P centering and shuttering etc. DSR Code No 5.3 Lintel |
| 9 | M.S. Work in R.C.C. Incluing supply of steel its wastage and hooks and authorised overlap (S No 3+8A)DSR Code No 5.22.1 |
| 10 | S/F M.S Fan box with 12mm Ms bar |
| 11 | Earth work in filling from 5 km. away from site including ramming ,dressing and levelling comp. DSR Code No 2.25(a) |
| 12 | Sand filling in foundation DSR Code No 2.27 |
| 13 | laying of PCC in 1:4:8 cement c sand and 40mm stone ballast including cost of material labour T&P etcDSR Code No 4.1.8 |
| 14 | 12mm thick plaster work in 1:4cement and fine sand mortor DSR Code No 13.1 |
| 15 | 52mm thick CC floor in 1:2:4 cement c sand and 20mm stone grit in panells finished by 3mm floating coat of neat cement without 3inch thick base concrete in 1:4:8 cement c sand and 40mm brick ballastDSR Code No 11.4 |
| 16 | P/ applying plaster of paris putty of avg. thickness 2mm of appd. Brand over the plastered wall surface to prepare to surface even and smooth DSR No 13.26 |
| 17 | finishing wall tex tured exterior paint of required shad : new work ( two or more coat) @3.28ltr /10sqm over and including priming coat of exterior primer applied @2.20kg /10sqmDSR Code No 13.45 |
| 18 | S/f of m.s. angle iron chaukhat40x40x6 mmDSR Code No 13.45 |
| 19 | S/F m.s. angle iron window grill , including all fitting and proper locking arangement (as per local market rate ) |
| 20 | S/f of 35mm thick Sitapur com. Quality ply wood shutters DSR Code No 9.20.1 |
| 21 | S/f of oxidise iron fitting |
| 22 | painting on new iron work in small areas with one coat of readymix priming coat and three coat of readymix paint appd. Brand as per DSr No 13.62.1 |
| 23 | S/f 5.5mm thick glass strip 3.50cm depth in flour |
| 24 | Rough cost plaster with 1:3 cement and c sand mortor com.in all respect DSR No 13.9.1 |
| 25 | S/F of first quality indian type white glazed earthen wear WC pan 580mm including supply of all material labour T&P with 10 Litre low level cistern com. In all respect (SI .N0 301) |
| 26 | S/F of first quality Urinal Basin com. (size 465x355x265mm)In all respect |
| 27 | S/f of 110mm dia PVC pipe 8kg /sqcm with socket and all accessories |
| 28 | S/F of low density PVC tank (syntax or equivalent quality ) 500ltr |
| 29 | S/f of 15mm dia PVC pipe line with socket bend tee etc complete in all respect |
| 30 | S/F of 25mm dia PVC pipe linewith socket bend tee etc complete in all respect |
| 31 | S/F of full way brass gate valve 25mm dia with wheel |
| 32 | S/F of 15mm dia brass gate valve with wheel |
| 33 | S/f of C.P. bib cock 15mm dia |
| 34 | S/F of 100 mm dia PVC pipe with clamps |
| 35 | Earth work in excavation in Soakpit DSr Code No 2.1.1 |
| 36 | Sand filling in foundation DSR Code No 2.27 |
| 37 | laying of PCC in 1:4:8 cement c sand and 40mm stone ballast including cost of material labour T&P etcDSR Code No 4.1.8 |
| 38 | M-150 brickwork in 1:4 cement and fine sand mortor including cost of material , labour, T&P complete in super structure.DSR Code No 6.1.1 |
| 39 | S/F of Aluminium door frame and Aluminium shutter with all aluminium fitting for locking arrengement (As per local market rate). |
| 40 | Brick bat filling in soakpit |
| 41 | site clearence before and after completion the work |
| 42 | Const. of B/Wall |
| 43 | Earth work In excavation in pits DSR Code No 2.6.1 |
| 44 | Sand filling in foundation DSR Code No 2.27 |
| 45 | Laying of PCC in 1:4:8 cement, c sand &40mm stone Ballast DSR Code No 4.1.8 |
| 46 | Laying of PCC in 1:1.5:3 cement, c sand &20mm stone Grit DSR Code No 4.1.2 |
| 47 | Boring of 25cm dia piles of double under reamed of 50cm dia of bulb and 3.60 meter depth in B.C. Soil with hand operated auger machine |
| 48 | R.C.C . Work in cement coarse sand and 20mm gauge stone gride in proportion 1:1.5:3 in piles grade beam excluding supply of reinforcement and also including supply of all material labour T&P centering and shuttering etc.DSR Code No 5.1.2 |
| 49 | R.C.C . Work in cement coarse sand and 20mm gauge stone gride in proportion 1:1.5:3 in columns excluding supply of reinforcement and also including supply of all material labour T&P centering and shuttering etc.DSR Code No 5.2.2 |
| 50 | M-150 brickwork in 1:6 cement and fine sand mortor including cost of material , labour, T&P complete in super structure DSR Code No 6.1.2+6.5 |
| 51 | 12mm thick plaster work in 1:4cement and fine sand mortor DSR Code No 13.1 |
| 52 | finishing wall tex tured exterior paint of required shad : new work ( two or more coat) @3.28ltr /10sqm over and including priming coat of exterior primer applied @2.20kg /10sqmDSR Code No 13.45 |
| 53 | finishing wall tex tured exterior paint of required shad : new work ( two or more coat) @3.28ltr /10sqm over and including priming coat of exterior primer applied @2.20kg /10sqmDSR Code No 13.45 |
| 54 | RCC work in 1:1.5:3 cement c sand and 20mm stone grit DSR Code No 5.3 |
| 55 | M.S. Work in RCC DSR Code No 5.22.A.1 |
| 56 | S/F of M.S. Gate including all fitting DSR Code No10.15.1 |
| 57 | S/f of MS Pipe 40x40x5 mm with hold fast DSR Code No10.31 |
| 58 | painting three coat over one priming coat of appd. Primer DSR Code No13.62.1 |
| 59 | Painting runway /taxi track marking with adequatenos of coats to give uniform finish with marking paint….com. DSR 16.47.1 |
| 60 | 12mm thick plaster work in 1:4cement and fine sand mortor DSR Code No 13.1 |
| 61 | Earth work in filling from 5 km. away from site including ramming ,dressing and levelling comp. DSR Code No 2.25(a) |
| 62 | M-150 brickwork in 1:6 cement and fine sand mortor including cost of material , labour, T&P complete DSR Code No6.1.2 |
| 63 | Steel work inbuilt up Tubular(round,square or ractangular hollow tubes etc) Trusses etc including cutting,hoisting,fixing in position and applying a priming coat of approved steel primer including welding and bolted with with special shaped washers etc all complete.DSR-10.16.2 |
| 64 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(0.63 mm thick sheet) DSR.12.1.3 |
| 65 | Supply of Bat-minton Court kit.with Net and Pole with Racket and shuttle cock badminton with portable & Movable as per lokal market rate |
| 66 | Supply of Basket Ball Court kit.with 6 Inch dia 2.2 mtr. Extension +20 mm board +Ring Fixed in Ground etc. as per lokal market rate |
| 67 | Supply of Valley Ball Court kit. With pole , Net & Volley Ball . Volley Ball Pole Fixed in Ground Adjustable Height 3 Inch x4 Feet Pipe as per lokal market rate |
| 68 | Supply of Foot Ball Court kit.with 3 Inch dia potable and movable on wheel as per lokal market rate |
| 69 | clearence of site |
| 70 | Fixing of sign board & photography |
| 71 | Installation of hand pump with Submersible Pump |
| 72 | Tranpotation of Handpump material and t&p from divi. Store to site of work |
| 73 | Hiring charge of necessary T&P and Equipment requried for instalation of Handpump cutter , wire rope lamps wooden Planks ,loading arrengment for palm and presser for com. Days including excavation of pit and water etc. complete |
| 74 | P/ of india mark hand pump machine and pipe etc |
| 75 | standerd deepwell hand pump machine complete |
| 76 | 140mm PVC pipe 8kg per sqm |
| 77 | P/ O 32mm diameter GI pipe B Class all completion |
| 78 | To make vertical bore 150mm dia boring by hand boring in following depthsin soil mixed with morum /shingle /kankar the depth of bore shall be according to strata condition this shall be decited by eng. I/C (0-30m) |
| 79 | To make vertical bore 150mm dia boring by hand boring in following depthsin soil mixed with morum /shingle /kankar the depth of bore shall be according to strata condition this shall be decited by eng. I/C (31-50m) |
| 80 | To make vertical bore 150mm dia boring by hand boring in following depthsin soil mixed with morum /shingle /kankar the depth of bore shall be according to strata condition this shall be decited by eng. I/C (50-60m) |
| 81 | S/F of end cap 110 mm dia required including all material labour T&P |
| 82 | S/F of nylon mesh required including all material labour T&P |
| 83 | Preparation of assembly as per eng. I/C and lowering of assembly consisting of110mm dia PVC pipe 6kg/sqcm, 1 kg /Sqcm, 10 kg /sqcm and testing ets vertically along with stainer pipe fitted at bottom .(0-45m) |
| 84 | Preparation of assembly as per eng. I/C and lowering of assembly consisting of110mm dia PVC pipe 6kg/sqcm, 1 kg /Sqcm, 10 kg /sqcm and testing ets vertically along with stainer pipe fitted at bottom .(45- above BGL) |
| 85 | S/Filling coarse sand arround stainer ( up to 3 mtr. From the bottom of stainer and filling of bentonite between bore hole and casing pipe including all material labour T&P |
| 86 | Lowring of 32mm dia GI pipe with ets cutting , threding etc. com. |
| 87 | Development of drilled bore hole sand till free yield of water is achieved in newly constructed bore hole including all material labour T&P etc. com. And installation of india marka II Hndpump (padestal) its position and its centering |
| 88 | disaffection by chlorination work of Development work of after handpump installation after devlopment including supply of all chemicals required. |
| 89 | Const. of PCC plateform in 1:2:4 of size 1.85 mtr. Dia as deparmental type design for India marka Handpumpe |
| 90 | Const. of PCC drain in 1:2:4 as deparmental type design complete |
| 91 | embossing on pedestal as per direction of eng.I/C |
| 92 | S/F oF 1.00HP Submersible pump with loweing,fitting,cable,Wire Rope,Controll panells & Pipe line fitting |
| 93 | P/laying pipe line in field &Building |
| 94 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C-1.10.3 |
| 95 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.-1.14 |
| 96 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire-1.14.1 |
| 97 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire-1.14.3 |
| 98 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.-1.25 |
| 99 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.-1.31 |
| 100 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.-1.32 |
| 101 | Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)-4 way (4 + 12), Double door-2.4.1 |
| 102 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.-2.1 Single pole |
| 103 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. -2.2 |
| 104 | Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A-Marcket Rate |
| 105 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.-5.4 |
| 106 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.- Marcket Rate. |
| 107 | Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed by the Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size - Marcket Rate |
| 108 | size 25 sq mm x 3-1/2core |
| 109 | Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA- DSR-1413 |
| 110 | Supply & fixing of recess mounting round 15 to 18 watt LED down Lighter having Powder coated die cast aluminium housing with heat sink , diffuser /reflector and driver set complete in all respect.CAT. - AAA- Marcket Rate |
| 111 | Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. |
| 112 | S/F OF 1.5 TAN SPLIT AC - Marcket Rate Please Enable Macros to View BoQ information |