| 1 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B, Wire make: Gloster,Havells, Grandlay, DJB approved make |
| 2 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 modular switch, connections ets as required. |
| 3 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections powder pained including earthing etc. 8way(4+24), Double door, Double door |
| 4 | Supplying and fixing 32A rating, 240/415V, 10KA C curve, Miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required pole. Single pole |
| 5 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100A. |
| 6 | Higher Wattage Decorative ultra slim polycarbonate LED lighting fixture with high lumen output, environmental friendly, energy efficient ready to use pack 25 W LED 6500 K Make :- Havells / Crompton / Orient / Philips/ Bajaj |
| 7 | Installation, testing and commissioning of pre wired, fluorescent fitting/ compact fluorescent/LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling / wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor single core cable and earthing etc. as required. |
| 8 | Supply of Ceiling fan heavy duty 1200 mm. Make :- Havells / Crompton / Orient / Philips/ Bajaj |
| 9 | Installation, testing and commissioning of ceiling fan, wall fan including wiring the down rods of standard length (up to 3 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 10 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required |
| 11 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 12 | Supply of exhaust fan heavy duty 900/1440 RPM size 300 mm. Make :- Havells / Crompton / Orient / Usha/ Bajaj |
| 13 | Installation of exhaust fan / air circulator fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required upto 450 mm sweep |
| 14 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7-meter-long etc. with charcoal/ coke and salt as required. |
| 15 | New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. Suitable for pole dia Ø 45 mm (max.) 70/72W LED Make :- Havells / Crompton / Orient / Philips/ Bajaj |
| 16 | Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation/ (during casting) for cable entry / wall including bending the pipe to the required shape complete as required of 40mm dia |
| 17 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 1X1.5 sq.MM , |
| 18 | Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X2.5sq.mm+1 X2.5sq.mm earth wire |
| 19 | Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired.2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 20 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 21 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 Sq.MM |
| 22 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 1X1.5 sq.MM , |
| 23 | Supply of 4 core 4 sq mm PVC/XLPE insulated electrical copper armoured cable Make: DJB approved make. (For supply of 70/72 Watt LED Street Lights) |
| 24 | Supply of 4 core 10 sq mm PVC/XLPE insulated electrical copper armoured cable Make: DJB approved make. (For supply of Main Cable from LT Panel to DB of new building.) Please Enable Macros to View BoQ information |