| 1 | Operation & Maintenance (O&M) |
| 2 | Unskilled |
| 3 | Semi-skilled |
| 4 | Supplying and erecting ultra violet storage type waterpurifier ( RO+UV+UF) with softener for safe drinkingwater consisting of UV germicidal tube of 8W capacity chokemade of copper wire and two indicator lamps, storagecapacity of purified water 7 to 8 litre with activated carbonfilter and softener operating on 230 V single phase A.C3-5-1 |
| 5 | Supplying and erecting 12V/180Ah tubular battery with battery terminal wire,duly charged with 36 months warranty complete |
| 6 | Providing annual comprehensive maintenance contract for 1.5TRsplit/window air conditioning unit complete as per terms and conditions. Jobincludes 1) quarterly servicing 2) on call repair 3) replacement of all spares within24 hours 4) sending standby manpower for VIP movement. The job exclude sheetmetal work and plastic material |
| 7 | Providing replacement of existing unservicablerotary/scroll compressor of air conditioner 1.5 TR bynew one of same capacity with guarantee for one year withprovided refrigerant complete. |
| 8 | Providing brazing pipes and checking leakages in thesplit/ window unit duly with dry nitrogen pressure in anapproved manner. |
| 9 | Providing vaccumising the airconditioner system to 200 micron andcharging with R32 refrigerant for 1.5TR window/split AC unit. |
| 10 | Supplying and erecting candle filter with filter pot forwater cooler. |
| 11 | Supplying and erecting connector Pipe for candle filter ofwater cooler |
| 12 | Providing replacement of base tray of water cooler of anycapacity. |
| 13 | Providing temporary illumination consisting of white/colour series lights with 8mm LED miniature lamps of 2 to 3.4V [1000nos] with cap with required switchgears erected and dismantled with rotor effect as approved with scaffolding up to three days. |
| 14 | Providing and fixing temporary electronic rotating machine to give running effect to strips lights and miniature lights up to a load of 5000 W 230v, 50Hz, complete with mains and required switchgears with continuous earth wire and dismantling up to three days. |
| 15 | Providing, maintaining and operating temporary public address system on hire consisting 02 Nos. solid state heavy wattage amplifier 250 watts ( one for working and another for stand by emergency ) working on AC / generator and 24 volt car battery supply, 06 Nos. of matching of 100 volt line (200 watts) box type speakers/sound column, 02 Nos super sensitive microphone with suitable size of microphone holding stand. The system shall be in a fully automatic change over operation in case of failure of supply for one day. |
| 16 | Providing, maintaining and operating temporary PA audio mixing consoles -stereo with built-in MP3 player, 48V phantom supply on all channelsprofessional mixer with 24 digital effects, 2 Group outputs. Mixer shall have 12 MIC and 10 line balanced mono inputs with enhanced headroom & each input channel has a gain control, 4 band active EQ controls, AUX1, AUX2, AUX3/EFX, AUX4/FX and PAN control with channel mute switch, with easy and accurate monitoring of left & right output levelsthrough individual 12 segment LED array, 11 preset EQ settings & headphone output with level control for output monitoring. The system shall be in a fully automatic change over operation in case of failure of supply for one day |
| 17 | Providing temporary illumination consisting of LED flood light fitting 100w,having colour temp up to 6500k, IP65, housing of pressure die castaluminium alloy and heat sink extruded aluminium complete erected withmains, switchgears with continuous earth wire erected and dismantled with usingscaffolding up to three days |
| 18 | Providing temporary illumination consisting of water proof LED Par Light, 54pieces x 3W, 230v, 50Hz, with RGBW controller complete erected withmains, switchgears with continuous earth wire erected and dismantled with usingscaffolding up to three days |
| 19 | Providing, commissioning and maintaining temporaryCCTV system with 8 channel NVR, IP video/audio input- 1 no, IP based 2.0 MP, Full HD, IR IP dome camera - 2nos, IP based 2.0 MP, Full HD, IR IP PTZ camera - 2 nos,2TB Hard Disk - 2 no, 32'' Full H D professional Display - 1no, 8 port PoE Switch - 1 no, Power supply unit to camera -1 no, On Line UPS UPS - 1 no with necessary mains,switchgears on hire basis for one day14-1-56 |
| 20 | Providing temporary digital projector having Full HD 1080p resolution with White and Colour Brightness at range of 3000-4000lm,HDMI port, USB port, AV port, computer port with spring loaded white screen connected with necessary mains, required switchgears and maintaining the same during the function including dismantling. |
| 21 | Providing temporary illumination consisting of LED rope light having 4 to 6 W capacity per meter [multi colour] and consisting suitable power adaptor with mains, switchgears erected and dismantled with using scaffolding and maintaining the same up to 3 days |
| 22 | Providing temporary illumination consisting of flood light fitting 200 W complete LED fitting having colour temp up to 6500k, IP65, housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete required switchgear erected and dismantled with using scaffolding up to three days. |
| 23 | Hiring charges for supplying and maintaining temporary 415V, 50 cycles AC generating set 11 to 25 kVA (excluding 25 kVA) capacity with necessary fuel, mains, switchgears and accessories complete with continuous running on load/no load as per requirements complete with self certification. 14-2-3 |
| 24 | Painting identification number by indelible ink marker / enamel paint on fittings / equipment with the help of ladders if necessary by dismantling and refitting the enclosures, tubes etc if required the same and refitting complete. |
| 25 | Carrying out Servicing of DG set up to 50 kVA with/without AMF Panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, Carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & properfrequency, Examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with Distilled water, Checking V belts with necessary adjustment, Checking and retightening of nut bolts including coupling bolts of engine and alternator, Checking & cleaning ofradiator and leakage testing Checking of radiator & fuel supply hose pipes,Checking of AVR, excitation diodes, its connections confirming proper outputvoltage. Checking & resetting of valve tappets, Cleaning of DG set internallyusing blower, cleaning radiator, Attending breakdowns as and when requiredduring One month period or during VIP visit within 2 hours of intimation andSubmit the servicing report to engineer in charge.(Non Comprehensive) as perspecification No. GEN-SER-AMC |
| 26 | Supplying, erecting, testing and commissioning of microprocessor based AMFpanel suitable for diesel generating set of above 15 kVA up to 20 kVAcapacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etcas per specification no. GEN-AMF. |
| 27 | Supplying and erecting 12V/180Ah tubular battery with battery terminal wire,duly charged with 36 months warranty complete |
| 28 | Supplying and erecting 12V/150Ah tubular battery with battery terminal wire,duly charged with 36 months warranty complete. |
| 29 | Supplying & erecting seamless outside & inside, smooth, dry and clean (New) copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete. |
| 30 | Supplying & erecting seamless outside & inside, smooth, dry and clean (New) copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete. |
| 31 | Supplying & erecting seamless outside & inside, smooth, dry and clean (New) copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 22mm complete. |
| 32 | Supplying & erecting seamless outside & inside, smooth, dry and clean (New) copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 32mm complete. |
| 33 | Supplying & erecting seamless outside & inside, smooth, dry and clean (New) copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 42mm complete. |
| 34 | Providing vaccumising the airconditioner system to 200 micron and charging with refrigerant R32 for 2TR window/split AC unit. |
| 35 | Providing replacement of existing unserviceable compressor of 150 litre cooling capacity water cooler by new one of same capacity along with suitable refrigerant with guarantee for one year. |
| 36 | Rewinding the motor of the ceiling fan 1200 mm / 1400 mm of all types, makes and over hauling including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year. |
| 37 | Rewinding the motor of the Exhaust fan 900/1400 RPM 450 mm of all types, makes and over hauling including minor repairs, lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year |
| 38 | Supplying & erecting single phase, 240V, street light control panel up to the max load of 6kW, SPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54, IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame/CC foundation. |
| 39 | Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54, IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. |
| 40 | Rewinding of submersible pump motor in Borewell of all types and makesabove 5 H.P. up to 25 H.P with coated copper wires & overhauling with minorrepairs, lubricating of ball bearings & bush bearing, and replacing screws etc.testing for the original speed, H.P. and no load consumption & guarantee for oneyear.4) Rates of Item No. 18-1-17 & 18-1-18 for rewinding of submersible pumpin open well and water tank shall be decreased by 40%. |
| 41 | Rewinding of submersible pump motor in Borewell of all types and makesup to and including 5 HP with coated copper wires & overhauling with minorrepairs, lubricating of ball bearings & bush bearing, and replacing screws etc.testing for the original speed, H.P. and no load consumption & guarantee for oneyear. |
| 42 | Supplying & erecting automatic control panel for 3 Ph, 415 volt, /centrifugalpump set up to 10 HP consisting of Star Delta starter having relay range 9-14Amp, S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed inCRCA powder coated Vibration proof enclosure with IP 54 protection. ControlPanel should offer single phasing, phase reversal, phase imbalance etc. |
| 43 | Supplying & erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with novolt coil and overload element with necessary materials and connected to supplyup to 7.5 H.P. |
| 44 | Supplying & erecting Fully Automatic Star/delta starter suitable for 12.5 H.Pto 15 H.P. for 3 phase squirrel cage motor totally enclosed with overload and novolt relay complete erected on provided angle iron frame. |
| 45 | Supplying and erecting G.I. pipe pole ‘B’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. OH-PL/GIP |
| 46 | Dismantling the existing cables of all types & size up to 10 sq mm. |
| 47 | Refilling the holes for dismantled cables with cement mortar & finishing etc.complete |
| 48 | Dismantling the existing underground cable without damaging it withglands, cable end box including refilling the trench up to ground level andmaking coils complete. |
| 49 | Supplying & erecting crimping type aluminium lugs for cable up to 16 sq mmcomplete as per specification No. CB-CL/AL |
| 50 | Supplying & erecting crimping type aluminium lugs for cable 25 sq mmcomplete as per specification No. CB-CL/AL |
| 51 | Supplying & erecting crimping type aluminium lugs for cable 35 sq mmcomplete as per specification No. CB-CL/AL |
| 52 | Supplying & erecting cast iron cable indicator plate buried along with route ofcable for PVC / XLPE armoured cable as per specification No. CB-CIP |
| 53 | Supplying & erecting water tight terminal box of 1.6 mm (16 gauge) CRCAsheet of size 200 x 150 x 150 mm. complete on pole as per specification No. CBSB |
| 54 | Supplying & erecting single compression type brass cable glands for 2 to 4core 2.5 sq mm /2 to 4 core 4 sq mm /2 core 6 sq mm for XLPE armouredcable as per specification No. CB-GL |
| 55 | Supplying & erecting single compression type brass cable glands for 3 to 4core 6 sq mm /2 to 4 core 10 sq mm for XLPE armoured cable as perspecification No. CB-GL |
| 56 | Supplying & erecting single compression type brass cable glands for 3 to 4core 16 sq mm /3 to 4 core 25 sq mm /3 core 35 sq mm for XLPE armouredcable as per specification No. CB-GL |
| 57 | Supplying and laying (including excavation of suitable width & depth up to 90cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPEfor enclosing cable below ground/road surface, to required depth complete. |
| 58 | Supplying & erecting G.I. pipe ‘A’ class 25 mm dia. erected for enclosingXLPE armoured cable on wall/pole as per specification no. CB-CE |
| 59 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL |
| 60 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL |
| 61 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formedwire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductorcomplete erected with glands & lugs, on wall/ trusses/pole or laid in providedtrench/ pipe as per specification no. CB-LT/AL |
| 62 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formedwire armoured (strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductorcomplete erected with glands & lugs, on wall/ trusses/pole or laid in providedtrench/ pipe as per specification no. CB-LT/AL |
| 63 | Supplying and erecting slotted angles, frames etc. for panel board or anyother purposes complete with bending, cutting, drilling and welding completeerected at the position with necessary materials duly painted with one coat ofred oxide and two coats of enamel paint to match the switchgears or as perdirections by the authority |
| 64 | Supplying and erecting GI sheet 1.6 mm (16 SWG) caution board of size 200 x150 mm duly painted with red oxide and enamel paint in Marathi, Hindi andEnglish erected at position for medium voltage (415 Volt) installation withcompliance to IS 2551-1982 |
| 65 | Supplying and erecting GI wire of high purity of required sizes used for earthingor any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/conduit with screws complete. |
| 66 | Supplying and erecting 9 Way AB cable distribution box on provided pole withnecessary accessories as per specification no. OH-ABC/JBS |
| 67 | Supplying and erecting 3 phase 5 core 95 sq.mm. (3x95+1x50+1x16) Aerialbunched aluminium cable along with necessary accessories for LT distributionon provided LT pole as per specification no. OH-CBL/ABC |
| 68 | Supplying and erecting 3 phase 5 core 70 sq.mm. (3x70+1x50+1x16) Aerialbunched aluminium cable along with necessary accessories for LT distributionon provided LT pole as per specification no. OH-CBL/ABC |
| 69 | Supplying and erecting 3 phase 5 core 25 sq.mm. (3x25+1x25+1x16) Aerialbunched aluminium cable along with necessary accessories for LT distributionon provided LT pole as per specification no. OH-CBL/ABC |
| 70 | Supplying and erecting 3 phase 5 core 16 sq.mm. (3x16+1x25+1x16) Aerialbunched aluminium cable along with necessary accessories for LT distributionon provided LT pole as per specification no. OH-CBL/ABC |
| 71 | Dismantling, cleaning and servicing of air cooler (4 ft to 5 ft size) |
| 72 | Removing old rust and painting of cooler body with anti-corrosive paint |
| 73 | Replacement of Khus (Cooling Pads) with new high-quality khus material |
| 74 | Repairing leakage of water tank including sealing and minor welding work |
| 75 | Replacement of water pump (standard submersible pump for cooler) |
| 76 | Rewinding of cooler motor including insulation and testing |
| 77 | Replacement of fan blade / fan assembly |
| 78 | Replacement of cooler pump (if separate circulation pump exists) |
| 79 | Checking and repairing electrical wiring, switch, capacitor Please Enable Macros to View BoQ information |