| 1 | item-1 | M/s MECO make AC ammeter, Model ML72, input 0-5 A DC, Scale 0-2500 A AC, Deflection angle 240 degree, Accuracy 2.5% of full scale as per attached specifications. |
| 2 | item-2 | M/s MECO make AC ammeter, Model ML110, input 0-5 A DC, Scale 0-800 A AC, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 3 | item-3 | M/s MECO make AC ammeter, Model ML110, input 0-5 A DC, Scale 0-200 A AC, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 4 | item-4 | M/s MECO make AC ammeter, Model ML110, input 0-5 A DC, Scale 0-1000 A AC, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 5 | item-5 | M/s MECO make AC ammeter model MLC110, input CTR 2500/5 A AC, Scale 0-2500 A AC Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 6 | item-6 | M/s MECO make AC ammeter model MLC110, input CTR 1500/5 A AC, Scale 0-1500 A AC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 7 | item-7 | M/s MECO make AC ammeter model MLC110, input CTR 800/5 A AC, Scale 0-800 A AC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 8 | item-8 | M/s MECO make AC ammeter model MLC144, input CTR 1200/5 A AC, Scale 0-1200 A AC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 9 | item-9 | M/s MECO make AC ammeter model MLC110, input CTR 150/5 A AC, Scale 0-150 A AC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 10 | item-10 | M/s MECO make model ML110, input (-15)-0-(+75)mV DC, Scale (-500)-0-(+2500) A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 11 | item-11 | M/s MECO make DC ammeter model ML110, input 0-50 mV DC, Scale 0-40 A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 12 | item-12 | M/s MECO make DC ammeter model ML110, input 0-75 mV DC, Scale 0-600 A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 13 | item-13 | M/s MECO make DC ammeter model ML110, input 0-50 mV DC, Scale 0-400 A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 14 | item-14 | M/s MECO make DC ammeter model ML110, input 0-75 mV DC, Scale 0-75 A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 15 | item-15 | M/s MECO make DC ammeter model ML110, input 0-75 mV DC, Scale 0-300 A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 16 | item-16 | M/s MECO make DC ammeter model ML110, input 0-75 mV DC, Scale 0-2000 A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 17 | item-17 | M/s MECO make DC ammeter model ML110, input 0-75 mV DC, Scale 0-30 A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 18 | item-18 | M/s MECO make DC ammeter model M96, input (-75)-0-(+75) mV DC, Scale (-50)-0-(+50) A DC, deflection angle 90 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 19 | item-19 | M/s MECO make DC ammeter model ML72, input 0-75 mV DC, Scale 0-3000 A DC, deflection angle 240 degree, Accuracy 2.5% of full scale as per attached specifications. |
| 20 | item-20 | M/s MECO make DC ammeter model ML110, input 0.2-1 A DC, Scale 0.2-1 A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 21 | item-21 | M/s MECO make DC ammeter model ML110, input 0-5 A DC, Scale 0-5 A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 22 | item-22 | M/s MECO make DC ammeter model ML110, input 0-1000 micro A DC, Scale 0-1000 micro A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 23 | item-23 | M/s MECO make DC ammeter model M96, input 0-5 A DC, Scale 0-5 A DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 24 | item-24 | M/s MECO make AC voltmeter model MLC110, input PTR 420/120 V AC, Scale 0-500 V AC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 25 | item-25 | M/s MECO make AC voltmeter model MLC144, input PTR 420/120 V AC, Scale 0-500 V AC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 26 | item-26 | M/s MECO make AC voltmeter model ML72, input 0-10 mA DC, Scale 0-25 KV AC, deflection angle 240 degree, Accuracy 2.5% of full scale as per attached specifications. |
| 27 | item-27 | M/s MECO make AC voltmeter model MLC72, input 0-150 V AC , Scale 0-150 V AC, deflection angle 240 degree, Accuracy 2.5% of full scale as per attached specifications. |
| 28 | item-28 | M/s MECO make AC voltmeter model MLC110, input 0-150 V AC , Scale 0-150 V AC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 29 | item-29 | M/s MECO make DC voltmeter model ML110, input 0-400 V DC , Scale 0-400 V DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 30 | item-30 | M/s MECO make DC voltmeter model ML110, input 0-75 V DC , Scale 0-75 V DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 31 | item-31 | M/s MECO make DC voltmeter model ML110, input 0-300 V DC , Scale 0-300 V DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 32 | item-32 | M/s MECO make DC voltmeter model M96, input 0-150 V DC , Scale 0-150 V DC, deflection angle 90 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 33 | item-33 | M/s MECO make DC voltmeter model M96, input 0-50 V DC , Scale 0-50 V DC, deflection angle 90 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 34 | item-34 | M/s MECO make DC voltmeter model ML72, input 0-60 V DC , Scale 0-60 V DC, deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 35 | item-35 | M/s MECO make DC voltmeter model ML72, input 0-60 V DC , Scale 0-60 V DC, deflection angle 240 degree, Accuracy 2.5% of full scale as per attached specifications. |
| 36 | item-36 | M/s MECO make DC voltmeter model ML72, input (-400)-0-(+400) V DC , Scale (-400)-0-(+400) V DC, deflection angle 240 degree, Accuracy 2.5% of full scale as per attached specifications. |
| 37 | item-37 | M/s MECO make DC voltmeter model ML72, input (-300)-0-(+300) V DC , Scale (-300)-0-(+300) V DC, deflection angle 90 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 38 | item-38 | M/s MECO make Wattmeter model 110LW33, input CTR 2500/5 A AC, input PTR 420/120 V AC, Scale 0-1750 KW, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 39 | item-39 | M/s MECO make Wattmeter model ML110, input 4-20 mA DC, scale (-60)-0-(+300) MW, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 40 | item-40 | M/s MECO make Wattmeter model ML110, input 4-20mA DC, scale (-15)-0-(+75) MW, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 41 | item-41 | M/s MECO make Wattmeter model ML110, input 4-20 mA DC, scale (-50)-0-(+250) MW, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 42 | item-42 | M/s MECO make Wattmeter model ML72, input 4-20 mA DC, scale (-50)-0-(+500) KW, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 43 | item-43 | M/s MECO make Wattmeter model ML110, input 4-20 mA DC, scale (-50)-0-(+500) KW, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 44 | item-44 | M/s MECO make Wattmeter model ML72, input 4-20 mA DC, scale (-0.4)-0-(+2) MW, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 45 | item-45 | M/s MECO make Wattmeter model ML96, input 4-20 mA DC, scale 0-1200 KW, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 46 | item-46 | M/s MECO make VAR meter model 110LV33, Input CTR 2500/5 A AC, PTR 420/120 V AC, Scale (-1000)-0-(+1000) KVAR, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 47 | item-47 | M/s MECO make VAR meter model 144LV33, Input CTR 1200/5 A AC, PTR 420/120 V AC, Scale 0-800 KVAR, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 48 | item-48 | M/s MECO make VAR meter model ML72, Input 4-20 mA DC, Scale (-0.4)-0-(+2) MVAR, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 49 | item-49 | M/s MECO make VAR meter model ML110, Input 4-20 mA DC, Scale (-500)-0-(+500) KVAR, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 50 | item-50 | M/s MECO make VAR meter model ML110, Input 4-20 mA DC, Scale (-60)-0-(+300) MVAR, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 51 | item-51 | M/s MECO make VAR meter model ML110, Input 4-20 mA DC, Scale (-15)-0-(+75) MVAR, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 52 | item-52 | M/s MECO make VAR meter model ML110, Input 4-20 mA DC, Scale (-100)-0-(+200) MVAR, Deflection angle 240 degree, Accuracy 1.5% of full scale as per attached specifications. |
| 53 | item-53 | M/s MECO make frequency meter model FL110, Input PTR 420/120 V AC, Scale 45-55 Hz, Deflection angle 240 degree, Accuracy 1% of full scale as per attached specifications. |
| 54 | item-54 | M/s MECO make frequency meter model F72, Input PTR 420/120 V AC, Scale 45-55 Hz, Deflection angle 90 degree, Accuracy 1% of full scale as per attached specifications. |
| 55 | item-55 | M/s MECO make Active power transducer model WT33, type 3 phase-2 element-3 wire, input CTR 2500/5 A AC, input PTR 420/120 V AC, Output 4-20 mA DC corresponding to scale(-0.4)-0-(+2) MW , load 500 ohm max., Aux. supply 85-265 V AC/DC, mounting DIN rail, Accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications. |
| 56 | item-56 | M/s MECO make Active power transducer model WT33, type 3 phase-2 element-3 wire, input CTR 800/5 A AC, input PTR 420/120 V AC, Output 4-20 mA DC corresponding to scale(-50)-0-(+500) KW , load 500 ohm max., Aux. supply 85-265 V AC/DC, mounting DIN rail, Accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications. |
| 57 | item-57 | M/s MECO make Active power transducer model WT33, type 3 phase-2 element-3 wire, input CTR 1200/5 A AC, input PTR 420/120 V AC, Output 4-20 mA DC corresponding to scale 0-920 KW , load 500 ohm max., Aux. supply 85-265 V AC/DC, mounting DIN rail, Accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications. |
| 58 | item-58 | M/s MECO make Active power transducer model WT33, type 3 phase-2 element-3 wire, input CTR 800/5 A AC, input PTR 230 KV/115 V AC, Output 4-20 mA DC corresponding to scale (-60)-0-(+300) MW , load 500 ohm max., Aux. supply 85-265 V AC/DC, mounting DIN rail, Accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications. |
| 59 | item-59 | M/s MECO make Active power transducer model WT33, type 3 phase-2 element-3 wire, input CTR 200/5 A AC, input PTR 230 KV/115 V AC, Output 4-20 mA DC corresponding to scale (-15)-0-(+75) MW , load 500 ohm max., Aux. supply 85-265 V AC/DC, mounting DIN rail, Accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications |
| 60 | item-60 | M/s MECO make Active power transducer model WT33, type 3 phase-2 element-3 wire, input CTR 1500/5 A AC, input PTR 420/120 V AC, Output 4-20 mA DC corresponding to scale 0-1200 KW , load 500 ohm max., Aux. supply 85-265 V AC/DC, mounting DIN rail, Accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications |
| 61 | item-61 | M/s MECO make Reactive power transducer model RPT33, type 3 phase-2 element-3 wire, input CTR 2500/5 A AC, input PTR 420/120 V AC, Output 4-20 mA DC corresponding to scale (-0.4)-0-(+2) MVAR , load 500 ohm max., Aux. supply 85-265 V AC/DC, mounting DIN rail, Accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications |
| 62 | item-62 | M/s MECO make Reactive power transducer model RPT33, type 3 phase-2 element-3 wire, input CTR 1200/5 A AC, input PTR 420/120 V AC, Output 4-20 mA DC corresponding to scale 0-920 KVAR, load 500 ohm max., Aux. supply 85-265 V AC/DC, mounting DIN rail, Accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications |
| 63 | item-63 | M/s MECO make Reactive power transducer model RPT33, type 3 phase-2 element-3 wire, input CTR 800/5 A AC, input PTR 230KV/115 V AC, Output 4-20 mA DC corresponding to scale (-60)-0-(+300) MVAR , load 500 ohm max., Aux. supply 85-265 V AC/DC, mounting DIN rail, Accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications |
| 64 | item-64 | M/s MECO make Reactive power transducer model RPT33, type 3 phase-2 element-3 wire, input CTR 200/5 A AC, input PTR 230KV/115 V AC, Output 4-20 mA DC corresponding to MVAR , load 500 ohm max., Aux. supply 85-265 V AC/DC, mounting DIN rail, Accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications |
| 65 | item-65 | M/s MECO make Reactive power transducer model RPT33, type 3 phase-2 element-3 wire, input CTR 800/5 A AC, input PTR 420/120 V AC, Output 4-20 mA DC corresponding to scale (-500)-0-(+500) KVAR , load 500 ohm max., Aux. supply 85-265 V AC/DC, mounting DIN rail, Accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications |