| 1 | Supply and installaiton of Volley ball ground lighting |
| 2 | Supply and installation testing and commissioning of 400W , 6500K IP 65 LED flood light having efficacy 110Lm/W or more including all necessary materials for installaiton on the lighting mast as directed. |
| 3 | Supply, Installation and commissioing of 11mtr height Steel tubular pole with arms for installation of 4 nos. LED lights as shwon in the drawing. as directed. (Excluding price PCC for foundation) |
| 4 | Supply of following sizes of 1.1 KV grade single core/multicore aluminium conductor XLPE insulated and PVC sheathed armoured / unarmoured cable conforming to IS 1554 (Part-I) 1988.4 Core,10 sq.mm. XLPE armoured Aluminium Cable for power supplu to mast from FP No. 6 as directed. |
| 5 | Supply of following sizes of 1.1 KV grade single core/multicore aluminium conductor XLPE insulated and PVC sheathed armoured / unarmoured cable conforming to IS 1554 (Part-I) 1988.3 Core, 4 sq.mm. XLPE armoured Aluminium Cable for pole SMC box connection as directed. |
| 6 | Supply of following sizes of 1.1 KV grade single core/multicore aluminium conductor XLPE insulated and PVC sheathed armoured / unarmoured cable conforming to IS 1554 (Part-I) 1988.3 Core, 4 sq.mm. XLPE unarmoured Aluminium Cable for lighting connection of the top of the pole form SMC box as directed. |
| 7 | Supply and installation of IP55 Poly carbonate SMC box size 230mmx170mmx105mm door fixed hinged (make - syntex) with 32A TP MCB DIN bar, Neutral bar, Earth bar ect. as required with necessary all materials required to fit the box on pole or as directed |
| 8 | Supply and installation of IP55 Poly carbonate SMC box size 230mmx170mmx105mm door fixed hinged (make - syntex) with 5A SP MCB DIN bar, Neutral bar, Earth bar ect. as directed with necessary all materials required to fit the box on pole or as directed |
| 9 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioC70:C80ning, protective covering and refilling the trench etc as required.Up to 35 sq. mm |
| 10 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Up to 35 sq. mm |
| 11 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on surface of building walls addirected Upto 35 sq. mm (clamped with 1mm thick saddle/PVC rope) |
| 12 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm |
| 13 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm |
| 14 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Up to 35 sq. mm |
| 15 | Supply and making cable end termination with brass compression glands and crimped aluminium lugs following sizes of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade of the following sizes as required.3 C X 10 sq. mm (82mm ) at feeder piller side, |
| 16 | Earthing for Volley ball ground lighting |
| 17 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 18 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 19 | Construction of 400mm x 400mm x 400mm masonry manhole with air tight C.I. Cover |
| 20 | Supply and installaiton of Lawn Tennis Courts lighting |
| 21 | Supply and installation testing and commissioning of 400W , 6500K IP 65 LED flood light having efficacy 110Lm/W or more including all necessary materials for installaiton on the lighting mast as directed. |
| 22 | Supply, Installation and commissioing of 11mtr height Steel tubular pole with arms for installation of 4 nos. LED lights as shwon in the drawing. as directed. (Excluding price PCC for foundation) |
| 23 | Supply of following sizes of 1.1 KV grade single core/multicore aluminium conductor XLPE insulated and PVC sheathed armoured / unarmoured cable conforming to IS 1554 (Part-I) 1988.4 Core,10 sq.mm. XLPE armoured Aluminium Cable for power supplu to mast from FP No. 6 as directed. |
| 24 | Supply of following sizes of 1.1 KV grade single core/multicore aluminium conductor XLPE insulated and PVC sheathed armoured / unarmoured cable conforming to IS 1554 (Part-I) 1988.3 Core, 4 sq.mm. XLPE armoured Aluminium Cable for pole SMC box connection as directed. |
| 25 | Supply of following sizes of 1.1 KV grade single core/multicore aluminium conductor XLPE insulated and PVC sheathed armoured / unarmoured cable conforming to IS 1554 (Part-I) 1988.3 Core, 4 sq.mm. XLPE unarmoured Aluminium Cable for lighting connection of the top of the pole form SMC box as directed. |
| 26 | Supply and installation of IP55 Poly carbonate SMC box size 230mmx170mmx105mm door fixed hinged (make - syntex) with 32A TP MCB DIN bar, Neutral bar, Earth bar ect. as required with necessary all materials required to fit the box on steel structure of the mast. or as directed |
| 27 | Supply and installation of IP55 Poly carbonate SMC box size 230mmx170mmx105mm door fixed hinged (make - syntex) with 5A DP MCB DIN bar, Earth bar ect. as reqiored with necessary anchor fastner required to fit the box on the wall at required position or as directed |
| 28 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioC70:C80ning, protective covering and refilling the trench etc as required.Up to 35 sq. mm |
| 29 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on surface of building walls addirected Upto 35 sq. mm (clamped with 1mm thick saddle/PVC rope) |
| 30 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm |
| 31 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Up to 35 sq. mm |
| 32 | Supply and making cable end termination with brass compression glands and crimped aluminium lugs following sizes of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade of the following sizes as required.3 C X 10 sq. mm (82mm ) at feeder piller side |
| 33 | Earthing for Lawn Tennis Courts lighting |
| 34 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 35 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 36 | Construction of 400mm x 400mm x 400mm masonry manhole with air tight C.I. Cover |
| 37 | Supply and installaiton of Basket Ball Courts lighting |
| 38 | Supply and installation testing and commissioning of 400W , 6500K IP 65 LED flood light having efficacy 110Lm/W or more including all necessary materials for installaiton on the lighting mast as directed. |
| 39 | Supply, Installation and commissioing of 11mtr height Steel tubular pole with arms for installation of 4 & 8 nos. LED lights as shwon in the drawing. as directed. (Excluding price PCC for foundation) |
| 40 | Supply of following sizes of 1.1 KV grade single core/multicore aluminium conductor XLPE insulated and PVC sheathed armoured / unarmoured cable conforming to IS 1554 (Part-I) 1988.4 Core,10 sq.mm. XLPE armoured Aluminium Cable for power supplu to mast from FP No. 6 as directed. |
| 41 | Supply of following sizes of 1.1 KV grade single core/multicore aluminium conductor XLPE insulated and PVC sheathed armoured / unarmoured cable conforming to IS 1554 (Part-I) 1988.3 Core, 4 sq.mm. XLPE armoured Aluminium Cable for pole SMC box connection as directed. |
| 42 | Supply of following sizes of 1.1 KV grade single core/multicore aluminium conductor XLPE insulated and PVC sheathed armoured / unarmoured cable conforming to IS 1554 (Part-I) 1988.3 Core, 4 sq.mm. XLPE unarmoured Aluminium Cable for lighting connection of the top of the pole form SMC box as directed. |
| 43 | Supply and installation of IP55 Poly carbonate SMC box size 230mmx170mmx105mm door fixed hinged (make - syntex) with 32A TP MCB DIN bar, Neutral bar, Earth bar ect. as required with necessary all materials required to fit the box on pole or as directed |
| 44 | Supply and installation of IP55 Poly carbonate SMC box size 230mmx170mmx105mm door fixed hinged (make - syntex) with 5A SP MCB DIN bar, Neutral bar, Earth bar ect. as directed with necessary all materials required to fit the box on pole or as directed |
| 45 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioC70:C80ning, protective covering and refilling the trench etc as required.Up to 35 sq. mm |
| 46 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Up to 35 sq. mm |
| 47 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on surface of building walls addirected Upto 35 sq. mm (clamped with 1mm thick saddle/PVC rope) |
| 48 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm |
| 49 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Up to 35 sq. mm |
| 50 | Supply and making cable end termination with brass compression glands and crimped aluminium lugs following sizes of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade of the following sizes as required.3 C X 10 sq. mm (82mm ) at feeder piller side, |
| 51 | Earthing for Basket Ball Courts lighting |
| 52 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 53 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 54 | Construction of 400mm x 400mm x 400mm masonry manhole with air tight C.I. Cover Please Enable Macros to View BoQ information |