| 1 | Design, Engineering, Procurement , Supply, Inspection, Testing, Packing, Forwarding and transporting of three-phase hybrid solar power plant |
| 2 | Design, Engineering, Procurement, Supply, Inspection, Testing, Packing, Forwarding and transporting of a 10 kW solar PV system comprising monocrystalline silicon, half-cut, bifacial solar modules, including GI mounting structure, complete cables, DC fuse, Cu Busbar, lightning arrestor and all associated material, as per technical specifications. |
| 3 | Design, Engineering, Procurement, Supply, Inspection, Testing, Packing, Forwarding and transporting of a minimum 40 kWh Li-ion battery bank of minimum 96 V DC configuration, including integrated Battery Management System (BMS), battery rack, interconnecting cables, cable termination kits, protection accessories, and all other associated material, complete in all respects, as per technical specifications. |
| 4 | Design, Engineering, Procurement, Supply, Inspection, Testing, Packing, Forwarding and transporting of a 10 kW, three-phase hybrid solar inverter with requisite MPPTs, including mounting accessories, DC/AC protections, monitoring accessories, and all other associated works, complete in all respects, as per technical specifications. |
| 5 | Design, Engineering, Procurement, Supply, Inspection, Testing, Packing, Forwarding and transporting of a LT Distribution panel with Manual Changeover switch inculding 6 nos of Outgoing 10A 4P MCB and monitoring accessories, and all other associated works, complete in all respects, as per technical specifications. |
| 6 | Procurement , Supply, Inspection, Testing, Packing, Forwarding and transporting of a prefabricated cabinet of size 20 ft × 10 ft × 8.5 ft (L × W × H) for battery room inculding 1.5 Ton AC, lighting fixtures, ceiling/wall fans, Exhaust Fans, internal cabling and all other associated Material, complete in all respects, as per technical specifications. |
| 7 | Procurement , Supply, Inspection, Testing, Packing, Forwarding and transporting of a prefabricated cabinet of size 12 ft × 10 ft × 8.5 ft (L × W × H) for inverter room, including internal furniture, lighting fixtures, ceiling/wall fans, Exhaust Fans, internal cabling and all other associated Materials, complete in all respects, as per technical specifications. |
| 8 | Procurement, supply, inspection, testing, packing, forwarding, and transportation of 9 m high steel Octagonal poles complete with single-side brackets/arms for LED luminaires, anti-climbing device/wire, and all other associated materials, complete in all respects, as per technical specifications. |
| 9 | Procurement, supply, inspection, testing, packing, forwarding, and transportation of 72 W LED street lighting luminaires, with built-in or separate driver, complete with internal cabling, 2-port IPC connector, required electrical protections, and all accessories suitable for mounting on steel Octagonal poles, along with all other associated materials, complete in all respects, as per technical specifications. |
| 10 | Supply of 1.1 kV grade, 4-core × 16 sq.mm aluminium conductor, XLPE insulated, armoured power cable, complete in all respects, as per approved technical specifications |
| 11 | Supply of CCTV surveillance system, including cameras, recording system, cabling, accessories, and all associated material complete in all respects, as per approved technical specifications |
| 12 | Supply of Tool Kit as per technical specifications |
| 13 | Unloading at site, handling, storing, erection, testing, commissioning of a three-phase hybrid solar power plant |
| 14 | Unloading at site, handling, storing, erection, testing, commissioning of a 10 kW solar PV system comprising monocrystalline silicon, half-cut, bifacial solar modules, including GI mounting structure, Excavation, Foundation, complete cables, DC fuse ,Cu Busbar, lightning arrestor earthing and all associated material, as per technical specifications. |
| 15 | Unloading at site, handling, storing, erection, testing, commissioning of a minimum 40 kWh Li-ion battery bank of minimum 96 V DC configuration, including integrated Battery Management System (BMS), battery rack, interconnecting cables, cable termination kits, protection accessories, and all other associated material, complete in all respects, as per technical specifications |
| 16 | Unloading at site, handling, storing, erection, testing, commissioning of a 10 kW, three-phase hybrid solar inverter with requisite MPPTs, including mounting accessories, DC/AC protections, monitoring accessories, and all other associated works, complete in all respects, as per technical specifications. |
| 17 | Unloading at site, handling, storing, erection, testing, commissioning of a LT Distribution panel with Manual Changeover switch inculding 6 nos of Outgoing 10A 4P MCB and monitoring accessories, and all other associated works, complete in all respects, as per technical specifications. |
| 18 | Unloading at site, handling, storing, erection, testing, commissioning of a prefabricated cabinet of size 20 ft × 10 ft × 8.5 ft (L × W × H) for battery room inculding 1.5 Ton AC, lighting fixtures, ceiling/wall fans, Exhaust Fans, internal cabling, Earthing and all other associated Material, complete in all respects, as per technical specifications. |
| 19 | Unloading at site, handling, storing, erection, testing, commissioning of a prefabricated cabinet of size 12 ft × 10 ft × 8.5 ft (L × W × H) for inverter room, including internal furniture, lighting fixtures, ceiling/wall fans, Exhaust Fans, internal cabling, Earthing and all other associated Materials, complete in all respects, as per technical specifications. |
| 20 | Unloading at site, handling, storing, erection, testing, commissioning of 9 m high Octagonal poles complete with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required, single-side brackets/arms for LED luminaires, Earthing on every 3rd pole, Earth Conductor for interconnection, anti-climbing device/wire, and all other associated materials, complete in all respects, as per technical specifications. |
| 21 | Unloading at site, handling, storing, Installation, testing, commissioning of 72 W LED street lighting luminaires, with built-in or separate driver, complete with internal cabling, 2-port IPC connector, required electrical protections, and all accessories suitable for mounting on Octagonal poles, along with all other associated materials, complete in all respects, as per technical specifications. |
| 22 | Laying of of 1.1 kV grade, 4-core × 16 sq.mm aluminium conductor, XLPE insulated, armoured power cable direct in ground including excavation, sand cushioning, Cable marker, protective covering and refilling the trench etc as required. |
| 23 | Installation, testing, commissioning of of CCTV surveillance system, including cameras, recording system, cabling, accessories, and all associated material complete in all respects, as per approved technical specifications |
| 24 | Supply of \\"Mandatory Spares\\" for Hybrid Solar Power Plants integrated with Street Lighting at MBRAPP |
| 25 | Miscellaneous Civil Work |
| 26 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil |
| 27 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth upto1km lead and any lift, complete all as per Technical specification and as directed by the Engineer-in- charge at all locations and at all leads and lifts: All kinds of soil |
| 28 | Providing and laying in position plain cement concrete of M10 grade 1:3:6 [1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size] including the cost of centering and shuttering complete all as per Technical specification and as directed by the Engineer-in-charge at all locations and at all lifts.\\" |
| 29 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. |
| 30 | Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth workand concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. |
| 31 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 32 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 33 | Providing and laying in position plain cement concrete of M10 grade 1:3:6 [1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size] including the cost of centering and shuttering complete all as per Technical specification and as directed by the Engineer-in-charge at all locations and at all lifts.\\" |
| 34 | Brick work with common burnt clay modular bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand). Above plinth level. cleaning the work area & disposing the debris / waste materials etc., up to\\" a lead of 100 Mts outside work premises etc. \\"complete all as per Technical specification and as directed by the Engineer-in-charge at all locations.\\" Please Enable Macros to View BoQ information |