| 1 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, by mechinical / manual means ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soil Pipes, cables etc, exceeding 80 mm dia. But not exceeding 300mm dia |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m All kinds of soil. |
| 3 | Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below. : MEDIUM: 100 mm. ( 12.40 kg./m ) |
| 4 | Fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. External work : 80 mm dia nominal bore/ 100 mm dia nominal bore |
| 5 | Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. External work : 50 mm dia nominal bore |
| 6 | Providing and fixing G.I flange 100/110 mm dia with nut and bolts etc all complete as per instruction of E/I. |
| 7 | Providing UPVC butterfly valve of approved quality ( Ashirwad or equivalent make ) or as approved by Engineer incharge 100 mm dia |
| 8 | Lowering, laying and jointing in positionfollowing UPVC/C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete (Rate for all class of valves) 100 mm. |
| 9 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore |
| 10 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 11 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 12 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 14 | Centering and shuttering including strutting, propping etc. removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 15 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 16 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 17 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 18 | Providing and installation of rain guns 50 mm dia BSP threaded of approved make full circle and part circle design on 50mm dia G.I. pipes with different sizes nozzle having minimum throw of water upto 35 m radius for dust suppression arrangement etc all complete as per instruction of E/I. |
| 19 | Supplying, erecting, testing and commissioning of minimum three & above star rated 3 phase, 415 V, 50 Hz, submersible pump set of 11 kW/15HP suitable for erection on open well, pump having delivery head from 78 to 18.m and discharge from 280 to 2400 litres per minute & 65/80/100 mm suction/ 50/65/80 mm delivery dia. as per specification no. WP-OSP. |
| 20 | Supplying, erecting, testing and commissioning of fully automatic star/delta starter suitable for above 15 HP upto 25 HP for three phase squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame. |
| 21 | Supplying, erecting, testing and commissioning of flat flexible 3 core 6 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 22 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 80 mm dia nominal bore |
| 23 | Operation & maintenance of rainguns/ sprinkling arrangement system with pumps/valves by deploying manpower (01 Nos/shift) at Dumri railway siding etc all complete job as per instruction of Engineer-in-charge. [Note: In case the workmen as mentioned above are not found at site by EIC or his authorized representative, then deduction will be made as per wages of the employed man. (Applicable minimum wages plus 15% [contractors' profit & Over head charges]). The deduction will be done on difference in man-days of workmen to be deployed as above minus the man-days of workmen actually deployed on quarterly basis (once in three months). ] |
| 24 | Painting G.I. pipes and fittings with two coats of anticorrosive bitumastic paint of approved quality :50 mm diameter pipe |
| 25 | Painting G.I. pipes and fittings with two coats of anticorrosive bitumastic paint of approved quality :80/100 mm diameter pipe |
| 26 | Hydrological survey (water devining charges) including yield test consisiting of yield, visit of expert authorised team along with necessary instrument, conducting resistivity survey preparation and submission of yield test report and suggesting pump type, capacity,depth etc all complete as per instruction of I/C. |
| 27 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.All types of soil300 mm dia |
| 28 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.All types of soil 300 mm dia |
| 29 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.150 mm nominal size dia having minimum wall thickness 5.00 mm |
| 30 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge.150 mm nominal size dia |
| 31 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part l).150 mm dia |
| 32 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.150 mm clamp |
| 33 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:150 mm dia |
| 34 | Providing and fixing pair of wooden sleeper of size 1.0 x 0.30 x 0.20 m for supporting clamp etc all complete as per instruction of E/I. |
| 35 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge |
| 36 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 37 | Supplying, erecting, testing and commissioning of minimum three & above star rated submersible pumpset of 5.625 kW/7.5 HP or as per suitable discharge with 415 V, three phase, 50 Hz A.C. supply suitable for 150 mm dia. borewell with 50 to 330 lpm discharge at 169 to 18 m head & discharge & delivery pipe of size-50 mm dia. with a necessary H type clamps as per specification no. WP-SMP (pump should be operated for 07 days total run after commencement and should carry manufacturers warranty for minimum period of 01 year the pump should be prefarably of KSB/C.R.I/Pullan or as approved by E/I) |
| 38 | Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below. : MEDIUM: 50 mm. ( 5.16 kg./m ) |
| 39 | Lowering, laying and jointing G. I. pipes andspecials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge. : MEDIUM: 50 mm. ( 5.16 kg./m ) |
| 40 | Supplying, erecting, testing and commissioning of flat flexible 3 core 6 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 41 | Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.C. Submersible/centrifugal pump set up to 7.5 HP- 10 H.P. consisting of DOL starter having relay range 13-21 AMP,S.P.P., Combined ammeter/voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc. |
| 42 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |