| 1 | (13.99) Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : (13.99.1) One or more coats on old work. |
| 2 | (13.50) Applying priming coat : (13.50.3) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works |
| 3 | (15.28) Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: (15.28.1) G.S. Sheet |
| 4 | (15.28) Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: (15.28.2) Asbestos cement sheet |
| 5 | (15.60) Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-incharge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 6 | (12.50) Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 7 | (12.51) Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete: (12.51.1) Ridges plain (500 - 600mm) |
| 8 | (12.51) Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete: (12.51.6) Gutter (600 mm over all girth) |
| 9 | (12.41) Providing and fixing on wall face unplasticised Rigid PVC rain water pipes confirming to IS 13592 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion, (i)Single socketed pipes. (12.41.2) 110 mm diameter |
| 10 | (12.42) Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. (12.42.1) Coupler (12.42.1.2) 110mm |
| 11 | (12.42) Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion (12.42.5) Bend 87.5° (12.42.5.2) 110 mm bend |
| 12 | (12.42)\\"Providing and fixing on wall face unplasticised Rigid PVC rain water pipes confirming to IS 14735 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion.Note: The following items under 24 - A to E. Rate should include cost of specials, consumables, labour, other incidental charges etc (12.42.6) Shoe (Plain) (12.42.6.2) 110 mm Shoe |
| 13 | (CVL-14.72)_(CVL-14.72)Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S.clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners,connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and Approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. |
| 14 | Removing steel-structural paint by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 15 | (26.81)Providing and fixing Scaffolding net of required width made of high density Polyethylene UV stabilized knitted on warp knitting machines having density 100gm/sqm and shading coefficient minimum 75% around the construction site/ for vertical extension as per requirement including fastening/tying with building/scaffolding pipes or with any other fixtures etc. complete as per direction of Engineer-in- Charge. (One time payment shall be made for providing Scaffolding net from start of work till completion of work including shifting if any. The Scaffolding net shall be the property of the contractor on completion of the work) |
| 16 | (15.42) Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : (15.42.3) 150 mm dia pipe Please Enable Macros to View BoQ information |