| 1 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminum round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. |
| 2 | Short point (up to 3 mtr.) |
| 3 | Medium point (up to 6 mtr.) |
| 4 | Long point (up to 10 mtr.) |
| 5 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 2 Nos Hot Dipped Galvanized M.S Modular box of 1.2 mm thick with earth terminal,2 Nos 6 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, screws, making connections, testing etc. as required. |
| 6 | Short point (up to 3 mtr.) |
| 7 | Medium point (up to 6 mtr.) |
| 8 | Long point (up to 10 mtr.) |
| 9 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 6 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. |
| 10 | On board |
| 11 | Short point (up to 3 mtr.) |
| 12 | Medium point (up to 6 mtr.) |
| 13 | Long point (up to 10 mtr..) |
| 14 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduit and making good the same as required. |
| 15 | 20 mm |
| 16 | 25 mm |
| 17 | 32 mm |
| 18 | Recessed PVC Conduit Wiring with Non Modular accessories |
| 19 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 1.2 mm thick Hot dipped Galavanized MS box with earth terminal, 6 A switch, 3 pin ceiling rose/holder / 3 way connector , 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. |
| 20 | Short point (up to 3 mtr.) |
| 21 | Medium point (up to 6 mtr.) |
| 22 | Long point (up to 10 mtr.) |
| 23 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 2 Nos 1.2 mm thick Hot dipped Galavanized MS box with earth terminal, 2 Nos 6 A two way switch,3 pin ceiling rose / holder/ 3 way connector, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. |
| 24 | Short point (up to 3 mtr.) |
| 25 | Medium point (up to 6 mtr.) |
| 26 | Long point (up to 10 mtr..) |
| 27 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, 1.2 mm thick Hot dipped Galavanized MS box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. |
| 28 | On board |
| 29 | Short point (up to 3 mtr.) |
| 30 | Medium point (up to 6 mtr.) |
| 31 | Long point (up to 10 mtr..) |
| 32 | S&F of following sizes of polypropelene corrugated flexible conduit including gland on both side of flexible conduit as required. |
| 33 | 16 mm OD |
| 34 | 20 mm OD |
| 35 | 25 mm OD |
| 36 | 32 mm OD |
| 37 | 40 mm OD |
| 38 | Surface PVC Conduit Wiring with Modular accessories |
| 39 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal/Surface mounted UPVC molded modular box, 6 A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. |
| 40 | Short point (up to 3 mtr.) |
| 41 | Medium point (up to 6 mtr.) |
| 42 | Long point (up to 10 mtr.) |
| 43 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modular box of 1.2 mm thick with earth terminal/Surface mounted UPVC molded modular box, 2 Nos 6 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, screws, making connections, testing etc. as required. |
| 44 | Short point (up to 3 mtr.) |
| 45 | Medium point (up to 6 mtr.) |
| 46 | Long point (up to 10 mtr.) |
| 47 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/Surface mounted UPVC molded modular box, 6 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. |
| 48 | On board |
| 49 | Short point (up to 3 mtr.) |
| 50 | Medium point (up to 6 mtr.) |
| 51 | Long point (up to 10 mtr..) |
| 52 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required on surface including heavy duty saddles with base at spacing of 0.60 mtr. etc as required. |
| 53 | 20 mm |
| 54 | 25 mm |
| 55 | 32 mm |
| 56 | 40 mm |
| 57 | 50 mm |
| 58 | Surface PVC Conduit Wiring with Non Modular accessories |
| 59 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot dipped Galvanized MS box with earth terminal of required size , 6 A switch, 3 pin ceiling rose/holder / 3 way connector , 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. |
| 60 | Short point (up to 3 mtr.) |
| 61 | Medium point (up to 6 mtr.) |
| 62 | Long point (up to 10 mtr.) |
| 63 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos 1.2 mm thick Hot dipped Galvanized MS box with earth terminal of required size, 2 Nos 6 A two way switch,3 pin ceiling rose / holder/ 3 way connector, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. |
| 64 | Short point (up to 3 mtr.) |
| 65 | Medium point (up to 6 mtr.) |
| 66 | Long point (up to 10 mtr..) |
| 67 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, 1.2 mm thick Hot dipped Galvanized MS box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. |
| 68 | On board |
| 69 | Short point (up to 3 mtr.) |
| 70 | Medium point (up to 6 mtr.) |
| 71 | Long point (up to 10 mtr..) |
| 72 | Surface Wiring in uPVC Trunking with Modular accessories |
| 73 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked ( IS:14927 P - II ) uPVC trunking & it's accessories, Hot Dipped Galvanized Modular box 1.2 mm thick with earth terminal/ Surface mounted UPVC molded modular box, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose/holder /3 way Connector, screws, making connections, testing etc. as required. |
| 74 | Short point (up to 3 mtr.) |
| 75 | Medium point (up to 6 mtr.) |
| 76 | Long point (up to 10 mtr.) |
| 77 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) of approved make on surface ISI marked ( IS:14927 P - II ) uPVC trunking & it's accessories, 2 No. Hot Dipped Galvanized Modular box 1.2 mm thick with earth terminal/ 2 No. Surface mounted UPVC molded modular box, 2 Nos 6 A two way Modular switch, 3 pin ceiling rose / holder/3 way Connector , Modular face plate with grid plate, screws, making connections, testing etc. as required |
| 78 | Short point (up to 3 mtr.) |
| 79 | Medium point (up to 6 mtr.) |
| 80 | Long point (up to 10 mtr..) |
| 81 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked ( IS:14927 P - II ) uPVC trunking & it's accessories, Hot Dipped Galvanized Modular box 1.2 mm thick with earth terminal/Surface mounted UPVC molded modular box, modular 6 A switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required |
| 82 | On board |
| 83 | Short point (up to 3 mtr.) |
| 84 | Medium point (up to 6 mtr.) |
| 85 | Long point (up to 10 mtr..) |
| 86 | S&F following sizes of ISI marked ( IS:14927 P - II ) uPVC trunking along with accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners etc. as required. |
| 87 | 20 mm x 12 mm |
| 88 | 25 mm x 12 mm |
| 89 | 32 mm x 12 mm |
| 90 | 25 mm x 16 mm |
| 91 | 38 mm x 16 mm |
| 92 | 38 mm x 25 mm |
| 93 | 38 mm x 38 mm |
| 94 | 50 mm x 16 mm |
| 95 | 50 mm x 50 mm |
| 96 | 75 mm x 50 mm |
| 97 | 75 mm x 75 mm |
| 98 | 100 mm x 50 mm |
| 99 | 100 mm x 100 mm |
| 100 | 150 mm x 50 mm |
| 101 | 150 mm x 100 mm |
| 102 | Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. |
| 103 | 1 x 1.5 sq.mm |
| 104 | 2 x 1.5 sq.mm |
| 105 | 3x 1.5 sq.mm |
| 106 | 4 x 1.5 sq.mm |
| 107 | 1 x 2.5 sq.mm |
| 108 | 2 x 2.5 sq.mm |
| 109 | 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 110 | 3 x 2.5 sq.mm |
| 111 | 4 x 2.5 sq.mm |
| 112 | 1 x 4.0 sq.mm |
| 113 | 2 x 4.0 sq.mm |
| 114 | 3 x 4 sq. mm. |
| 115 | 4 x 4.0 sq.mm |
| 116 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 117 | 1 x 6.0 sq.mm |
| 118 | 2 x 6.0 sq.mm |
| 119 | 3 x 6.0 sq. mm. |
| 120 | 4 x 6.0 sq.mm |
| 121 | 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. |
| 122 | 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. |
| 123 | 1 x 10.0 sq.mm |
| 124 | 2 x 10.0 sq.mm |
| 125 | 4 x 10.0 sq.mm |
| 126 | 1 x 16.0 sq.mm |
| 127 | 2 x 16.0 sq.mm |
| 128 | 4 x 16.0 sq.mm |
| 129 | Supplying and Laying coaxial cable 75 ohm impedance with foam PE insulated solid bare copper inner conductor, and Ist outer conductor of bonded alum. tape and second outer conductor of alum. alloy braid in existing surface or recessed conduit/casing capping including making connections as required. |
| 130 | RG - 6 |
| 131 | RG -11 |
| 132 | Supplying and Laying PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 & confirming to TEC specification GR / WIR/06-03 March 2002 in existing surface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. |
| 133 | 2 pair |
| 134 | 4 pair |
| 135 | 5 pair |
| 136 | 10 pair |
| 137 | 20 pair |
| 138 | 50 pair |
| 139 | 100 pair |
| 140 | 200 pair |
| 141 | Supply and Laying of PE Insulated, PVC Inner Sheathed, armoured & PVC Sheathed Telephone Cable. with 0.5 mm thick Solid Annealed Bare Copper Conductor as per IS: 8130/84 telephone cable confirming to TEC specifications GR/WIR 06/03, Mar.-2002 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size. |
| 142 | 5 pair |
| 143 | 10 pair |
| 144 | 20 pair |
| 145 | 50 pair |
| 146 | 100 pair |
| 147 | 200 pair |
| 148 | Supply and Laying of PE Insulated jelly filled Armoured Telephone Cable. with 0.6 mm thick Solid Annealed Bare Copper Conductor and confirming to TEC specifications confirming. to DOT GR/CUG-01/Aug.2003 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size. |
| 149 | 5 pair |
| 150 | 10 pair |
| 151 | 20 pair |
| 152 | 50 pair |
| 153 | 100 pair |
| 154 | 200 pair |
| 155 | Supply & laying service connection with ISI marked (IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWG G.I. Support wire duly clipped etc. as required. |
| 156 | 2.5sq.mm |
| 157 | 4.0 sq.mm |
| 158 | 6.0 sq.mm |
| 159 | 10.0 sq.mm |
| 160 | Supply and Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, existing pipe / open trench / Cable tray / on surface including making connection etc. as required. |
| 161 | 1.5 Sq.mm 3 core flat / Round |
| 162 | 2.5 Sq.mm 3 core flat / Round |
| 163 | 4.0 Sq.mm 3 core flat / Round |
| 164 | 6.0 Sq.mm 3 core flat / Round |
| 165 | 10.0 Sq.mm 3 core flat / Round |
| 166 | 16.0 Sq.mm 3 core flat / Round |
| 167 | Supply and laying following size twin parallel type Speaker cables made with multi wire, bright annealed flexible bare electrolytic grade copper conductor, insulated with specially formulated transparent grade PVC compound, red strip for identification in existing conduit etc. as required. |
| 168 | 0.75 sq.mm |
| 169 | 1.0 Sq. mm |
| 170 | 1.5 Sq.mm |
| 171 | 2.5 Sq.mm |
| 172 | Supply and laying speaker cable of following size 2 core twin twisted multi stranded electrolytic grade copper conductor, overall PVC insulated and armoured cable (Blue colour) on surface/ above false ceiling including cost of GI spacers, saddles etc. as required. |
| 173 | 0.75 sq.mm |
| 174 | 1.0 Sq. mm |
| 175 | 1.5 Sq.mm |
| 176 | 2.5 Sq.mm |
| 177 | Supply and laying PVC Insulated and PVC Round Sheathed Multi Core copper conductor (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing pipe / open trench / Cable tray / on surface including making connection etc. as required. |
| 178 | 1.5 sq.mm x 3 core |
| 179 | 1.5 sq.mm x 4 core |
| 180 | 1.5 sq.mm x 6 core |
| 181 | 1.5 sq.mm x 8 core |
| 182 | 2.5 sq.mm x 3 core |
| 183 | 2.5 sq.mm x 4 core |
| 184 | 2.5 sq.mm x 6 core |
| 185 | 2.5 sq.mm x 8 core |
| 186 | 4.0 sq.mm x 3 core |
| 187 | 4.0 sq.mm x 4 core |
| 188 | 4.0 sq.mm x 6 core |
| 189 | P & F 1.2 mm thick Hot dipped galvanized boxes with brass earthing terminal of following sizes (nominal size) in recessed/surface as required. |
| 190 | 75mm x 75mm x 60mm |
| 191 | 100mm x 100mm x 60mm |
| 192 | 150mm x 75mm x 60mm |
| 193 | 175mm x 100mm x 60mm |
| 194 | 150mm x 150mm x 60mm |
| 195 | 225mm x 100mm x 60mm |
| 196 | 200mm x 150mm x 60mm |
| 197 | 200mm x 125mm x 75mm |
| 198 | 200mm x 250mm x 75mm |
| 199 | 200mm x 250mm x 100mm |
| 200 | 250mm x 300mm x 75mm |
| 201 | 250mm x 300mm x 100mm |
| 202 | 300mm x 375mm x 75mm |
| 203 | 300mm x 375mm x 100mm |
| 204 | 250mm x 100mm x 60mm |
| 205 | 300mm x 100mm x 60mm |
| 206 | 300mm x 300mm x 75mm |
| 207 | P & F in position frame made out of M.S. angle (riveted or welded) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required. |
| 208 | 25mm x 25mm x 3mm |
| 209 | 25mm x 25mm x 5mm |
| 210 | 35mm x 35mm x 5mm |
| 211 | 40mm x 40mm x 5mm |
| 212 | 50mm x 50mm x 6mm |
| 213 | P & Fixing Powder coated CRCA sheet enclosures on existing Structure by means of nuts and bolts and making holes , Din rail etc. as required. |
| 214 | 1.2 mm thick |
| 215 | 1.6 mm thick |
| 216 | 2.0 mm thick |
| 217 | 2.5 mm thick |
| 218 | P & Fixing M.S. flat on existing angle iron frame and making required nos. of holes for fixing accessories including one coat of red oxide paint and two coats of enamel paint etc. as required. |
| 219 | 25 mm x 3 mm |
| 220 | 25 mm x 5 mm |
| 221 | 32 mm x 5 mm |
| 222 | 40 mm x 6 mm |
| 223 | 50 mm x 6 mm |
| 224 | P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required. |
| 225 | 3.0 mm thick |
| 226 | 5.0 mm thick |
| 227 | 6.0 mm thick |
| 228 | 8.0 mm thick |
| 229 | 10.0 mm thick |
| 230 | 16.0 mm thick |
| 231 | 20.0 mm thick |
| 232 | P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required. |
| 233 | 75 mm dia |
| 234 | 100 mm dia. |
| 235 | P & F P.V.C. sheet 2.0 mm thick of following size Including screws, cup washer as required. |
| 236 | 75 mm dia. |
| 237 | 100 mm dia. |
| 238 | P & F Aluminium sheet 1.0 m thick of following size dia. Including screws, cup washer as required. |
| 239 | 75 mm dia. |
| 240 | 100 mm dia. |
| 241 | P & F 1.2 mm thick M.S. Recessed concealed box, round of size 150 mm dia, depth 100 mm complete as required. |
| 242 | Labour charges for dismantling of surface PVC/ Steel conduit including wiring in conduit, conduit fittings and depositing the same with listing of material in store. |
| 243 | Labour charges for dismantling of surface/ recessed switch board of any size and depositing the same with listing of material in store. |
| 244 | Labour charges for dismantling of switch accessories like switch, socket, ceiling rose, holder and depositing the same with listing of material in store. |
| 245 | Labour charges for dismantling of wiring in existing conduit of following size and depositing the same with listing of material in store. |
| 246 | up to 2.5 sq. mm. wire |
| 247 | 4/ 6 sq. mm. wire |
| 248 | 10 sq. mm. wire |
| 249 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. |
| 250 | Single pole MCB (With B / C curve tripping characteristics) |
| 251 | 6 A to 32 A rating |
| 252 | 40 A rating |
| 253 | 50/63 A rating |
| 254 | Double pole MCB (With B / C curve tripping characteristics) |
| 255 | 0.5 A to 5 A rating |
| 256 | 6 A to 32 A rating |
| 257 | 40 A rating |
| 258 | 50/63 A rating |
| 259 | Triple pole MCB (With B / C curve tripping characteristics) |
| 260 | 0.5A to 5 A rating |
| 261 | 6 A to 32 A rating |
| 262 | 40 A rating |
| 263 | 50/63 A rating |
| 264 | Four pole MCB (With B / C curve tripping characteristics) |
| 265 | 0.5A to 5 A rating |
| 266 | 6 A to 32 A rating |
| 267 | 40 A rating |
| 268 | 50/63 A rating |
| 269 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (Metal / Glazed / Acrylic) Distribution board with Metal end box made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, complete with 100 amp. insulated copper bus bar/shorting link , brass neutral link with shrouds, brass earth link , door earthing arrangement, color coded interconnecting wire set of minimum 10.0 sqmm size and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. |
| 270 | Metal door (single phase) IK-09 and IP-43 with Metal end box |
| 271 | 4 Way |
| 272 | 6 Way |
| 273 | 8 Way |
| 274 | 12 Way |
| 275 | 16 Way |
| 276 | Metal door (Three phase) IK-09 and IP-43 with Metal end box |
| 277 | 4 Way (8 incomer + 12 Outgoing) |
| 278 | 6 Way (8 incomer + 18 Outgoing) |
| 279 | 8 Way (8 incomer + 24 Outgoing) |
| 280 | 12 Way (8 incomer + 36 Outgoing) |
| 281 | Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for MCB / RCCB/ RCBO up to 63 Amp and SP / TP MCB upto 32 Amp. as outgoing ,made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3 complete with insulated 100 A rating copper bus bar, brass neutral bars with shrouds, brass earth bar , color coded interconnecting wire set of suitable rating and din bar, door earthing arrangement, masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. |
| 282 | Double door IK-09 & IP-43 with Metal end box |
| 283 | 4 Way (8 Incomer +12 Outgoing) |
| 284 | 6 Way (8 Incomer +18 Outgoing) |
| 285 | 8 Way (8 Incomer +24 Outgoing) |
| 286 | 12 Way (8 Incomer + 36 Outgoing) |
| 287 | Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB up to 63 Amps. as outgoing ,made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. complete with insulated 125/160/200/250 Amp. copper bus bar, brass neutral bars with shrouds, brass earth bar , color coded interconnecting wire set of suitable rating and din bar, door earthing arrangement, masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. |
| 288 | Double door IP-43 & IK-09 with Provision of Incomer MCCB up to 125 A Rating with Metal end box |
| 289 | 4 Way |
| 290 | 6 Way |
| 291 | 8 Way |
| 292 | 12 Way |
| 293 | P & F ISI marked (IS:3854) 6 amp. flush type non modular switch with CM/L no. printed and made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required. |
| 294 | P & F ISI marked (IS :3854) 16 amp. flush type non modular switch CM/L no. printed and made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required. |
| 295 | Providing & Fixing of 6 amp. Combined flush type non modular socket and switch set made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required. |
| 296 | Providing & Fixing of 16 amp. Combined flush type non modular socket and switch set with indicator and fuse set, made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required. |
| 297 | Providing & Fixing of ISI marked (IS :3854) non modular 6A bell push surface type CM/L no. printed and made out from industrial grade Polycarbonate material including making connection testing etc. as required. |
| 298 | Providing & Fixing of ISI marked (IS :3854) twin control non modular 6A switch surface type, CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required. |
| 299 | Providing & Fixing of ISI marked (IS :3854) non modular 6A bell push flush type CM/L no. printed and made out from industrial grade Polycarbonate materialincluding cutting hole in tile and making connection testing etc. as required. |
| 300 | Providing & Fixing of ISI marked (IS :3854) twin control non modular 6A switch flush type CM/L no. printed , made out from industrial grade Polycarbonate material, including cutting hole in tile and making connection testing etc. as required. |
| 301 | Providing & Fixing of non modular 6A hanging bell push/one way switch made out from industrial grade Polycarbonate material including making connection testing etc. as required. |
| 302 | Providing & Fixing of IS:1293 marked of 3 pin 6 amp. flush type non modular socket CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required. |
| 303 | Providing & Fixing of IS:1293 3/6 pin 16 amp flush type non modular socket CM/L no. printed and made out from Industrial grade Polycarbonate material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required. |
| 304 | Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required. |
| 305 | Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required. |
| 306 | Providing & Fixing of ISI marked (IS:1293) 6 amp unbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal including making connection testing etc. as required. |
| 307 | Providing & Fixing of ISI marked (IS:1293) 16 amp unbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal including making connection testing etc. as required. |
| 308 | Providing & Fixing of flush type non modular 2 pin telephone socket with plug top made out from industrial grade Polycarbonate material, brass terminals including making connection testing etc. as required. |
| 309 | Providing & Fixing of flush type non modular single line telephone jack made out from industrial grade Polycarbonate material, including making connection testing etc. as required. |
| 310 | Providing & Fixing of flush type non modular double line telephone jack made out from industrial grade Polycarbonate materialincluding making connection testing etc. as required. |
| 311 | Providing & Fixing of flush type non modular coaxial T.V. socket made out from industrial grade Polycarbonate material,including making connection testing etc. as required. |
| 312 | Providing & Fixing of IS 11037 marked non modular socket size flush type 100 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate material including making connection testing etc. as required. |
| 313 | P & F ISI marked 32 A D.P. switch with fuse and indicating lamp including making connection testing etc. as required. |
| 314 | Providing & Fixing of ISI marked (IS:302) gong bell with CM/L no. printed including making connection testing etc. as required. |
| 315 | Providing & Fixing of Non Modular Neon Light including making connection testing etc. as required. |
| 316 | Providing & Fixing of single / multi tone electronic call bell / remote bell including making connection testing etc. as required. |
| 317 | Providing & Fixing of ISI marked (IS:302) ding dong/musical chime bell including making connection testing etc. as required. |
| 318 | Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant virgin UV Stabilized Polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating ,minimum width of switch toggle( PUSH PART ) should not less then 20mm, including making connections, testing etc as required. |
| 319 | 6 A one way switch |
| 320 | 6 A two way switch |
| 321 | 6 A bell push |
| 322 | 10 A one way switch |
| 323 | 10 A two way switch |
| 324 | 16 A one way switch 1M |
| 325 | 20 A one way switch 1M |
| 326 | 20 A one way switch 2M |
| 327 | 16 Amp. 2 Module switch With Led Indicator |
| 328 | 32 Amp. 2 Module switch With Led Indicator |
| 329 | Providing & Fixing of IS:1293 marked modular type lockable feature socket with CM/L no. printed duly made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testing etc as required. |
| 330 | 6 A 3 pin shuttered socket |
| 331 | 6/16 A shuttered socket |
| 332 | 13 A flat pin international socket (Non ISI) |
| 333 | Providing & Fixing of modular type 100W Step Fan regulator duly ISI marked (IS 11037) with CM/L no. printed made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including making connections, testing etc as required. |
| 334 | 5 step fan regulator 2 Module |
| 335 | Providing & Fixing of 3 M Key card switch with Load capacity 20 amp, Off time delay 30 Sec. made out of unbreakable and fire retardant virgin poly carbonate, including making connections, testing etc as required. |
| 336 | Providing & Fixing of following modular accessories, made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testing etc as required. |
| 337 | RJ-11 telephone jack single line |
| 338 | RJ-11 telephone jack Double line |
| 339 | USB Charger 2 A - 1 M with BIS mark |
| 340 | RJ-45, Cat 6 computer jack with shutter |
| 341 | T.V. coaxial socket |
| 342 | Blanking plate |
| 343 | 25 Amp. 2 Module Motor Starter with on / off Push button |
| 344 | LED Skirting /Foot Light 2 Module |
| 345 | Electronic Chime/Buzzer 2M |
| 346 | Modular MCB 6 A to 32 A SP |
| 347 | Modular MCB 6 A to 32 A DP |
| 348 | Providing & Fixing of following size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect. |
| 349 | 1/2 Module |
| 350 | 3 Module |
| 351 | 4 Module |
| 352 | 5 Module |
| 353 | 6 Module |
| 354 | 8 Module |
| 355 | 10 Module |
| 356 | 12 Module |
| 357 | 16/18 Module |
| 358 | Providing & Fixing of following size cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect. |
| 359 | 1/2 Module |
| 360 | 3 Module |
| 361 | 4 Module |
| 362 | 5 Module |
| 363 | 6 Module |
| 364 | 8 Module |
| 365 | 10 Module |
| 366 | 12 Module |
| 367 | 16/18 Module |
| 368 | Providing & Fixing of Hot dipped Galvanized metal box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required. |
| 369 | 1-2 Module |
| 370 | 3 Module |
| 371 | 4-5 Module |
| 372 | 6-8 Module |
| 373 | 10-12 Module |
| 374 | 16/18 Module |
| 375 | Providing & Fixing of Wiring Accessories OEM fabricated following size virgin material UPVC modular boxes on surface suitable for modular accessories as required. |
| 376 | 1-2 Module |
| 377 | 3 Module |
| 378 | 4/5 Module |
| 379 | 6 / 8 module |
| 380 | 10 / 12 module |
| 381 | 16/18 module |
| 382 | Providing & Fixing of Multiple socket with surge and spikes protection cartridge not less then 5 KV with minimum four nos. universal 6 A sockets, one 6 A switch and 3 pin company fitted plug top and 3 core multistrand copper lead minimum 1.5 mtr. including making connection etc as required. |
| 383 | Providing & Fixing of DLP PVC adaptable trunking system for cable management including finishing accessories like corners, tees, adjustable angles, junction etc. as required . The trunking system shall have adaptable system for modular type RJ 45 data socket/ wiring accessories/ power sockets and shall be covered with peal off plastic cover. OEM have to submit NABL accrediated /CPET lab test reports /EN 50085-2-1 complaince certificate. |
| 384 | 80mm x 50mm |
| 385 | 100/105mm x 50mm |
| 386 | 150/160mm x 50mm |
| 387 | 195/200mm x 50mm |
| 388 | Providing and fixing of power plug point with non modular accessories with Galvanized box of 1.2 mm thick with earth terminal with suitable size 3.0 mm thick phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outlet making connection , testing , etc. as required. |
| 389 | Supplying and fixing of power plug point with Modular accessories on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. |
| 390 | P & F Krone module with base frame in the recess / surface made out of 1.2 mm thick sheet steel box, front openable, having locking arrangements duly powder coated ,including dressing, ferruling and punching of telephone cable with krone tool etc. as required. |
| 391 | 10 Pairs |
| 392 | 20 Pairs |
| 393 | 50 Pairs |
| 394 | 100 Pairs |
| 395 | 200 Pairs |
| 396 | P & F Portable Residual Current Device (PRCD) 3 pin plug top 16 A, 30 mA sensitivity. Plug should have feature of power indicator, test button and reset function etc. as required. |
| 397 | SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- |
| 398 | (a) Thickness of CRCA sheet shall not be less than 1.6 mm upto 450 mm length/ width of any compartment and be 2.0 mm above 450 mm, load bearing structure shall be 2.0 mm thick sheet supported by base M.S. channel if required, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided |
| 399 | (b) complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side(Inner & Outer side) of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. |
| 400 | [c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra ) |
| 401 | (d) Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. |
| 402 | (e) All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. |
| 403 | (f) Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra ) |
| 404 | (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. |
| 405 | (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI type Test certificates for Temp. rise test, Short circuit test for 50 kA and IP test is to be submitted) |
| 406 | Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator, with short circuit withstand capacity of 31 MVA for 1 Sec. , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. |
| 407 | Electrolytic grade Aluminium bus bar 6010 grade |
| 408 | Electrolytic grade (Cu+ETP) Tin Coated annealed copper bus bars IACS 100% grade. |
| 409 | Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 27 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. |
| 410 | Red/yellow/Green colour |
| 411 | Blue / white Colour |
| 412 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation from 50 to 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle ( to be paid extra) , including making connections etc. as required. OEM shall have submit NABL / CPRI / ERDA/ Intertek accrediated lab type test certificate. |
| 413 | 3 pole MCCB With Thermal Magnetic release |
| 414 | up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting |
| 415 | up to 100 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 416 | 125 Amp , 25 kA, adjustable O/L & fixed S/C setting, |
| 417 | 160 Amp , 25 kA, adjustable O/L & fixed S/C setting, |
| 418 | 200 Amp , 25 kA, adjustable O/L & fixed S/C setting, |
| 419 | 250 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 420 | 250 Amp , 35 kA, adjustable O/L & adjustable S/C setting, |
| 421 | 4 pole MCCB With Thermal Magnetic release |
| 422 | up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting |
| 423 | up to 100 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 424 | 125 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 425 | 160 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 426 | 200 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 427 | 250 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 428 | 250 Amp , 35 kA, adjustable O/L & adjustable S/C setting, |
| 429 | Supply and fixing of following accessories for Moulded case circuit breaker (MCCB) compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. |
| 430 | Spreaders upto 125A, 3 Pole MCCB |
| 431 | Spreaders for 160A, 3 Pole MCCB |
| 432 | Spreaders for 160A, 4 Pole MCCB |
| 433 | Spreaders for 250A, 3 Pole MCCB |
| 434 | Spreaders for 250A, 4 Pole MCCB |
| 435 | Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size. |
| 436 | 4.0 Sq. mm |
| 437 | 2 core |
| 438 | 3 core |
| 439 | 4 core |
| 440 | 6.0 Sq. mm |
| 441 | 2 core |
| 442 | 3 core |
| 443 | 4 core |
| 444 | 10.0 Sq. mm |
| 445 | 2 core |
| 446 | 3 core |
| 447 | 4 core |
| 448 | 16.0 Sq. mm |
| 449 | 2 core |
| 450 | 3 core |
| 451 | 4 core |
| 452 | 25.0 Sq. mm |
| 453 | 2 core |
| 454 | 3 core |
| 455 | 3.5 core |
| 456 | 35.0 Sq. mm |
| 457 | 2 core |
| 458 | 3 core |
| 459 | 3.5 core |
| 460 | 50.0 Sq. mm |
| 461 | 2 core |
| 462 | 3 core |
| 463 | 3.5 core |
| 464 | Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Copper cable confirming to IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, round / flat strip armouring, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. |
| 465 | 1.5 Sq. mm |
| 466 | 2 core |
| 467 | 3 core |
| 468 | 4 core |
| 469 | 6 core |
| 470 | 8 core |
| 471 | 10 core |
| 472 | 12 core |
| 473 | 2.5 Sq. mm |
| 474 | 2 core |
| 475 | 3 core |
| 476 | 4 core |
| 477 | 6 core |
| 478 | 8 core |
| 479 | 10 core |
| 480 | 12 core |
| 481 | 4.0 Sq. mm |
| 482 | 2 core |
| 483 | 3 core |
| 484 | 4 core |
| 485 | 6.0 Sq. mm |
| 486 | 2 core |
| 487 | 3 core |
| 488 | 4 core |
| 489 | 10.0 Sq. mm |
| 490 | 2 core |
| 491 | 3 core |
| 492 | 4 core |
| 493 | Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. |
| 494 | Add extra in item no. 11.1 to 11.4 for Laying Charges for cable through Manual Boggi by making pit at regular interval and repairing the pit after laying of cable with PCC/ Bitumin as required. |
| 495 | Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as per IS 8337-1976 of following size of PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required. |
| 496 | 2 x 4.0 sq.mm |
| 497 | 2 x 6.0 sq.mm |
| 498 | 2 x 10.0 sq.mm |
| 499 | 2 x 16.0 sq.mm |
| 500 | 2 x 25.0 sq.mm |
| 501 | 3 x 4.0 sq.mm |
| 502 | 3 x 6.0 sq.mm |
| 503 | 3 x 10.0 sq.mm |
| 504 | 3 x 16.0 sq.mm |
| 505 | 3 x 25.0 sq.mm |
| 506 | 3.5 x 25.0 sq.mm |
| 507 | 4 x 4.0 sq.mm |
| 508 | 4 x 6.0 sq.mm |
| 509 | 4 x 10.0 sq.mm |
| 510 | 4 x 16.0 sq.mm |
| 511 | Supplying and making end termination with heavy aluminium lugs ( Pin / ring type ) confirming to IS 8309 -1993 duly crimped with crimping tool, PVC tape etc of following size. |
| 512 | 1.5 Sq.mm |
| 513 | 2.5 Sq.mm |
| 514 | 4.0 Sq.mm |
| 515 | 6.0 Sq.mm |
| 516 | 10.0 Sq.mm |
| 517 | 16.0 Sq.mm |
| 518 | 25.0 Sq.mm |
| 519 | Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required. |
| 520 | Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required. |
| 521 | Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required. |
| 522 | SITC of Copper Bonded rod Earthing with high tensile strength (more than 600 N / sq.mm low carbon steel rod molecularly bonded with Copper thickness (250 microns) and confirming to UL 467 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- |
| 523 | (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole |
| 524 | (b)Earth enhancing compound to ensure the moisture content and electrical conductivity, 25 kg for 3000 mm. The compound shall be tested form NABL accredited lab for low resistivity (less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content in accordance with IEC 62561-7 |
| 525 | © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt |
| 526 | (d) Place Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. |
| 527 | (e) Testing of earth resistance for value of 5 ohms or less as required. |
| 528 | (f) Test certificates for confirming above standards from OEM is mandatory. |
| 529 | 17.2 mm thick and 3 Mtr. Long |
| 530 | 25 mm thick and 3 Mtr. Long |
| 531 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. |
| 532 | 6 SWG tinned copper Wire |
| 533 | 8 SWG tinned copper Wire |
| 534 | 10 SWG tinned copper. Wire |
| 535 | 6 SWG copper Wire |
| 536 | 8 SWG copper Wire |
| 537 | 10 SWG copper. Wire |
| 538 | 6 SWG G.I. ( Hot Dipped ) Wire |
| 539 | 8 SWG G.I. ( Hot Dipped ) Wire |
| 540 | Making of hole in wall (brick/stone) of required and placing NP-2 RCC pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. |
| 541 | Up to 457 mm size |
| 542 | more than 457 mm & up to 610 mm |
| 543 | Supply & Fixing of phenolic laminated board of 6.0 mm thick for fresh air fan/exhaust fan up to size of 300 mm on existing window frame including cost of board, cutting of hole , Nut bolts etc. as required. |
| 544 | Installation , testing and Commissioning of ceiling fan (any size) including wiring the down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor, Cotter pin, rubber grommet making connection testing etc. as required. |
| 545 | With regulator |
| 546 | Without regulator |
| 547 | Providing & Fixing BLDC technology step regulator compatible ceiling fan, with aluminium body & aluminium blade, power factor not less then 0.9 , following service value (CMM/W) , with following air delivery , speed 350 RPM ( tolerance as per IS:374 2019 ) THD less then 10%, copper winding with class of Insulation 'F' complete with with secondary support safety cable ( steel rope), down rod up to 30 cm, cotter pin, shackle kit with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. |
| 548 | 1200 mm sweep with Air delivery >/= 230 CMM and Service Value 8.20 |
| 549 | 1400 mm sweep with Air delivery >/= 270 CMM and Service Value 7.70 |
| 550 | 1200 mm sweep with Air delivery >/= 215 CMM and Service Value 7.00 |
| 551 | 1400 mm sweep with Air delivery >/= 260 CMM and Service Value 6.4 |
| 552 | Providing & Fixing of of BLDC Technology ventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutter including making connection, testing etc. as required. |
| 553 | 150 mm sweep with Min. Air delivery 350 Cubic meter/Hr, 2000 RPM |
| 554 | 200 mm sweep with Min. Air delivery 800 Cubic meter/Hr, 1600 RPM |
| 555 | 250 mm sweep with Min. Air delivery 1150 Cubic meter/Hr, 1300 RPM |
| 556 | Providing & Fixing of 400 mm Sweep BLDC technology Oscillating type Wall mounting / Pedestal type fans with Three speed, ON and OFF position, Double Wall bearing with front and back 120 or more ribs guard; Three no. blades, noise level should be <= 75 dB, including fixing with anchor bolts, making connection testing etc. as required. ( With Remote ) |
| 557 | Wall mounting type with Service value 2.0 CMM /W, Min. Air Delivery 71 CMM |
| 558 | Pedestal Type having Adjustable Height with Service value 2.6 CMM /W, Min. Air Delivery 85 CMM |
| 559 | Providing & Fixing of BEE Star rated copper wounded with class of Insulation 'F', double ball bearing capacitor start, aluminium body & aluminium blade ceiling fan conforming to all the performance requirements laid down in IS 374:2019 with down rod up to 30 cm with secondary support safety cable ( steel rope) , cotter pin, shackle kit with 3 x 1.5 sq.mm pvc insulated flexible copper conductor and making connection testing etc. as required. |
| 560 | 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) |
| 561 | 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) |
| 562 | 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) |
| 563 | 1400 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) |
| 564 | 1400 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) |
| 565 | 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) with minimum Air delivery 230 CMM |
| 566 | 1400 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) with minimum Air delivery 230 CMM |
| 567 | Providing & Fixing of shackle (iron hook) made from 2mm nominal thick CRCA sheet and bolts (2nos) of 6mm with spring washer nut, checknut & split pin as required. |
| 568 | Providing & Fixing of of M.S. J- hook of standard design made out of 16 mm dia. M.S. round bar and fixed with cement concrete mortar with required support as required. |
| 569 | P & F 1.2 mm thick M.S. Recessed fan box and top lid screwed on Box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 150 mm length extended on each side as required. |
| 570 | P & F 3.0 mm thick Poly propelene plastic polished concealed fan box, squre of size (106x106) mm dia, depth 50 mm , 10 mm dia rod of MS with chrome plated with 55 mm length extended on each side as required. |
| 571 | Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core 1.5 Sq.mm copper conductor ,making connections, testing etc. as required. |
| 572 | 230 mm sweep, Minimum air delivery 750 Cum / hour |
| 573 | 300 mm sweep Minimum air delivery 1600 Cum / hour |
| 574 | Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 marked in existing opening including making connections testing etc. as required. |
| 575 | 300 mm sweep(900 RPM) |
| 576 | 380 mm sweep(900 RPM) |
| 577 | 450 mm sweep(1400 RPM) |
| 578 | 600 mm sweep(900 RPM) |
| 579 | Providing & Fixing of ventilating fans Capacitor start, copper wounded, single phase with PVC impeller, ABS body, automatic openable louver shutter in existing opening including making connection, testing etc. as required. |
| 580 | 150 mm sweep Minimum Air Delivery 150 Cum / hour |
| 581 | 200 mm sweep Minimum Air Delivery 450 Cum / hour |
| 582 | 250 mm sweep Minimum Air Delivery 750 Cum / hour |
| 583 | Providing & Fixing of Wall mounting / Pedestal type Heavy duty Air Circulator , Double ball bearing and with metal sturdy mesh guard; Aluminium alloy one piece blade and conforming to IS:2997, including fixing with anchor bolts, making connection testing etc. as required. |
| 584 | 450 mm sweep Wall mounting and three speed regulator with Minimum Air Delivery 150 Cum. / Minute |
| 585 | 450 mm sweep Pedestal type and three speed regulator with Minimum Air Delivery 150 Cum. / Minute |
| 586 | Providing & Fixing of 450 mm Sweep Oscillating type Wall mounting / Pedestal type fans with Three speed, ON and OFF position, Sintered Iron bush oil impregnated, with metal front and back 120 or more ribs guard; Three no. Aluminium blades, minimum Air delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./min/watt, noise level should be <= 75 dB, power consumption <= 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required. |
| 587 | Wall mounting type with Adjustable Vertical Angle |
| 588 | Pedestal Type with Adjustable Height |
| 589 | Providing & Fixing of extra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe including cutting, threading, drilling, fixing quarter pin etc as required. |
| 590 | Numbering of ceiling fans/ fixtures with approved enamel paint etc as required. |
| 591 | P & F of Gravity Louver shutter of superior quality made out of frame of 18 swg M.S. sheet & Louvers made from 24 swg MS Sheet with enamel paint including cost of nuts, bolts, etc as required. |
| 592 | Up to 380 mm size |
| 593 | above 380 mm size |
| 594 | P & F of Wall cowl with Bird Screen Suitable for Outside Wall of Exhaust Fan Opening of following size and made out from 24 SWG GI sheet as per instructions of Engineer in charge including fixing with suitable fasteners etc. as required. |
| 595 | Suitable for 300 mm sweep Exhaust Fan |
| 596 | Suitable for 380 mm sweep Exhaust Fan |
| 597 | Suitable for 450 mm sweep Exhaust Fan |
| 598 | Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap action adjustable thermostat , Dual indicating lamps Injected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top , including making inlet, outlet Flexible alloy connection, testing etc. as required. |
| 599 | 6 Ltr. |
| 600 | 10 Ltr. |
| 601 | 15 Ltr. |
| 602 | 25 Ltr. |
| 603 | 35 Ltr. |
| 604 | SITC of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output only at CW (5700K to 6500K) , internal surge protection of 4.0 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 605 | 1170mm(+/-10%) LED batten with min. lumen output 2200 lm |
| 606 | 570mm (+/-10%) batten with min. lumen output 1000 lm |
| 607 | 1170mm(+/-10%) LED batten with min. lumen output 4400 lm |
| 608 | SITC of IP20 SMD Mid Power LED batten with integrated box (min.1200mmx40mmx60mm including reflector) with replacable driver fixture made from Powder coated Extruded aluminium housing ,Min. lumen output 4800 lm, System lumen efficacy ≥ 120 lm/Watt output nly at CW (5700K to 6500K), internal surge protection of 4.0 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 609 | SITC of IP-20 LED Recessed / Surface Mounted, Round / Square backlit & SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS compliance 4.0 KV surge protected Isolated driver, with Short & Open circuit protection input 320VAC-48 hr protection, input 350VAC-2 hr protection), having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt,at CW (5700K to 6500K) , THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 610 | Recessed Mounting |
| 611 | Minimum lumen output 600 lm (lumen efficacy ≥ 100 lm / watt) |
| 612 | Minimum lumen output 1300 lm |
| 613 | Minimum lumen output 1600 lm |
| 614 | Minimum lumen output 1950 lm |
| 615 | Minimum lumen output 2400 lm |
| 616 | Surface Mounting (with extruded alumn. Housing ) |
| 617 | Minimum lumen output 600 lm (lumen efficacy ≥ 100 lm / watt) |
| 618 | Minimum lumen output 1300 lm |
| 619 | Minimum lumen output 1600 lm |
| 620 | Minimum lumen output 1950 lm |
| 621 | Minimum lumen output 2400 lm |
| 622 | SITC of IP20, 2'x2' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmissivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V . High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection ( input 320VAC-48 hoursprotection,input 350VAC-2 hours protection) (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 623 | Recessed Mounting |
| 624 | Minimum lumen output 4320 lm |
| 625 | Minimum lumen output 4800 lm |
| 626 | Surface Mounting (Driver should be Inside the Luminaire) |
| 627 | Minimum lumen output 4320 lm |
| 628 | Minimum lumen output 4800 lm |
| 629 | SITC of IP20, 1'X1' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution.operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 630 | Recessed Mounting |
| 631 | Minimum lumen output 2880 lm |
| 632 | Minimum lumen output 3600 lm |
| 633 | Surface Mounting (Driver should be Inside the Luminaire) |
| 634 | Minimum lumen output 2880 lm |
| 635 | Minimum lumen output 3600 lm |
| 636 | SITC of IP20, 1'x4' LED Surface/ Recessed mounting Mid power SMD type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V. High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 637 | Recessed Mounting |
| 638 | Minimum lumen output 4320 lm |
| 639 | Minimum lumen output 4800 lm |
| 640 | Surface Mounting (Driver should be Inside the Luminaire) |
| 641 | Minimum lumen output 4320 lm |
| 642 | Minimum lumen output 4800 lm |
| 643 | SITC of IP20, 1100-1200 mm x 50-60 mm x 70-85 mm size Suspended mounting backlit & SMD mid power type LED linear Light fixture made from Extruded Aluminium housing, PMMA Acrylic/Extruded Polycarbonate push fit type diffuser for uniform light distribution. High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). Lumen Efficacy will be >=100lm/W only at CW (5700K to 6500K) ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating . Luminiare can connect each other through jointer kit (cost of jointer kit is included) as required. |
| 644 | Minimum lumen output 2000 lm |
| 645 | Minimum lumen output 3000 lm |
| 646 | SITC of IP65 IK08 rated Integrated High power LED ( each LED between 3 to 5 watt power with secondary lencs on each LED) Highbay light fixture made from Pressure Die Cast Aluminium housing, UV stabilized PC Cover/ Toughened glass diffuser, potted driver, Eye bolt for mounting, system lumen efficacy ≥150 lm/Watt output , THD < 10% ,p.f.≥0.95,CRI >70 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and . surge protection 4 KV inbuilt & 10 KV external inside fixture as required. |
| 647 | Minimum lumen output 12000 lm |
| 648 | Minimum lumen output 15000 lm |
| 649 | Minimum lumen output 18000 lm |
| 650 | Minimum lumen output 22500 lm |
| 651 | SITC of Suspended mounting IP66 IK08 rated Integrated High power LED Wellglass light fixture made from Pressure Die Cast Aluminium housing, potted driver, Eye bolt for mounting, PC clear / Opal Diffuser, system lumen efficacy ≥130 lm/Watt output only at CW (5700K to 6500K) , THD < 10% ,p.f.≥0.95,CRI >70 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating surge protection 4 KV inbuilt & 10 KV external inside fixture as required. |
| 652 | Minimum lumen output 4550 lm |
| 653 | Minimum lumen output 9100 lm |
| 654 | SITC of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 655 | 2/3 Watt |
| 656 | 6/7 Watt |
| 657 | 9 Watt |
| 658 | 15 Watt |
| 659 | 18/20 Watt |
| 660 | SITC of IP 20 box made out from 1.0 mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tube including side covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube). |
| 661 | Suitable for 2' LED Tube shape fixture for single rod |
| 662 | Suitable for 4' LED Tube shape fixture for single rod |
| 663 | Suitable for 4' LED Tube shape fixture for double rod |
| 664 | SITC of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. system lumen efficacy ≥ 100 lm/Watt outputonly at CW (5700K to 6500K) , internal surge protection of 2.5 KV,THD < 15% ,p.f.≥0.95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 665 | 600mm , Min. Lumens output 1800 lm LED Tube rod with Polycarbonate Housing |
| 666 | 1200mm , Min. Lumens output 2000 lm LED Tube rod with Polycarbonate Housing |
| 667 | 1200mm, Min. Lumens output 2000 lm LED Tube rod with Glass Housing |
| 668 | SITC of IP65 IK08 rated Integrated SMD Mid power LED bulk head type light fixture made from Pressure Die Cast AL housing suitable with integral driver, system lumen efficacy ≥120 lm/Watt output only at CW (5700K to 6500K) , THD < 15% ,p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 669 | Minimum lumen output 1200 lm |
| 670 | SITC of IP-20 LED Recessed / Surface Mounted, Round / Sqaure backlit & SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 4.0 KV surge protected Isolated driver, with Short & Open circuit protection input 320VAC-48 hr protection, input 350VAC-2 hr protection), having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt,at CW (5700K to 6500K) , THD < 10 % , Pf.≥0.95, CRI >80, UGR (unified glare rating)<19, fliker free (current ripple should be below 5%), SDCm (standard deviation colour matching)<5.life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 671 | Recessed Mounting |
| 672 | Minimum lumen output 1300 lm |
| 673 | Minimum lumen output 1600 lm |
| 674 | Minimum lumen output 1950 lm |
| 675 | Minimum lumen output 2400 lm |
| 676 | Surface Mounting (with extruded alumn. Housing ) |
| 677 | Minimum lumen output 1300 lm |
| 678 | Minimum lumen output 1600 lm |
| 679 | Minimum lumen output 1950 lm |
| 680 | Minimum lumen output 2400 lm |
| 681 | SITC of IP20, 2'x2' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V . High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection ( input 320VAC-48 hoursprotection,input 350VAC-2 hours protection) (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , UGR (unified glare rating)<19, fliker free (current ripple should be below 5%), SDCm (standard deviation colour matching)<5 life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 682 | Recessed Mounting |
| 683 | Minimum lumen output 4320 lm |
| 684 | Minimum lumen output 4800 lm |
| 685 | Surface Mounting (Driver should be Inside the Luminaire) |
| 686 | Minimum lumen output 4320 lm |
| 687 | Minimum lumen output 4800 lm |
| 688 | SITC of IP20, 1'x4' LED Surface/ Recessed mounting Mid power SMD type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V. High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , UGR (unified glare rating)<19, fliker free (current ripple should be below 5%), SDCM (standard deviation colour matching)<5life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 689 | Recessed Mounting |
| 690 | Minimum lumen output 4320 lm |
| 691 | Minimum lumen output 4800 lm |
| 692 | Surface Mounting (Driver should be Inside the Luminaire) |
| 693 | Minimum lumen output 4320 lm |
| 694 | Minimum lumen output 4800 lm |
| 695 | SITC of IP20, 1'X1' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution.operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , UGR (unified glare rating)<19, fliker free (current ripple should be below 5%), SDCM (standard deviation colour matching)<5 life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 696 | Recessed Mounting |
| 697 | Minimum lumen output 2880 lm |
| 698 | Minimum lumen output 3600 lm |
| 699 | Surface Mounting (Driver should be Inside the Luminaire) |
| 700 | Minimum lumen output 2880 lm |
| 701 | Minimum lumen output 3600 lm |
| 702 | SITC of IP-20 LED Recessed Mounted, Round backlit & COB type LED Downlighter of Powder Coated diecast/Extruded Aluminium body including trim with aluminium deflector and construction as per IS:10322 with 2.5 KV surge protected Isolated driver with Short & Open circuit protection (Input 320VAC-48 hours protection, Input 350VAC-2 hours protection) having efficiency > 85%, operating voltage 140-270 V AC. System Lumen efficacy of ≥ 100 lm /watt, at CW (5700K to 6500K) , THD < 10 % , Pf.≥0.95, CRI >80, UGR(Unified Glare Rating)< 19, Fliker free(current ripple should be below 5%), SDCM(Standard Deviation Color Matching) < 5, life time of minimum 50000 Burning Hours with 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 703 | lumen output 550 lm to 770 lm |
| 704 | lumen output 880 lm to 1100 lm |
| 705 | lumen output 1320 lm to 1650 lm |
| 706 | Providing & Fixing of IK07 IP65 protected Top/Bottom mounted LED Post top Luminarie top & bottom made of single piece construction powder coated die cast alluminium housing with UV stabalized Clear / frosted Polycarbonate diffuser and Aluminium anodised with powder quoted reflector. The System level Luminous efficacy ≥ 80 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . LED Driving output current <750mA as required. |
| 707 | Minimum lumen output 2800 lm Post top Luminarie |
| 708 | Minimum lumen output 3200 lm Post top Luminarie |
| 709 | Minimum lumen output 3600 lm Post top Luminarie |
| 710 | Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass with suitable lenses on LED / integrated lens diffuser to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated metal case potted driver as a unique BIS R number (as per IS 15885) having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate(Fitting & driver both have separate BIS R number). The System level Luminaire efficacy >=130 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , LED driving output current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K as required. |
| 711 | High Power LED Flood Light Minimum lumen outpu 3900 lm |
| 712 | High Power LED Flood Light Minimum lumen output 6500 lm |
| 713 | High Power LED Flood Light Minimum lumen output 10400 lm |
| 714 | High Power LED Flood Light Minimum lumen output 13000 lm |
| 715 | High Power LED Flood Light Minimum lumen output 15600 lm |
| 716 | High Power LED Flood Light Minimum lumen output 19500 lm |
| 717 | High Power LED Flood Light Minimum lumen output 23400 lm |
| 718 | High Power LED Flood Light Minimum lumen output 26000lm |
| 719 | High Power LED Flood Light Minimum lumen output 32500 lm |
| 720 | High Power LED Flood Light Minimum lumen output 39000 lm |
| 721 | High Power LED Flood Light Minimum lumen output 45500 lm |
| 722 | High Power LED Flood Light Minimum lumen output 52000 lm |
| 723 | High Power LED Flood Light Minimum lumen output 65000 lm |
| 724 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing and secondary lens on each LED/ integrated lens diffuser without cover & should be High power LED of 3 to 5 watt each . The System efficacy >=135 lm/ wt and integrated metal case potted driver & has a unique BIS R number ( as per IS 15885) with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . LED driving output current <750mA. The luminaire shall be BIS certified (Fitting & driver both have separte BIS R number) and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs as required. |
| 725 | LED Street Light fixture with Minimum lumen output 2700 lm |
| 726 | LED Street Light fixture with Minimum lumen output 4050 lm |
| 727 | LED Street Light fixture with Minimum lumen output 6075 lm |
| 728 | LED Street Light fixture with Minimum lumen output 8100 lm |
| 729 | LED Street Light fixture with Minimum lumen output 9450 lm |
| 730 | LED Street Light fixture with Minimum lumen output 12150 lm |
| 731 | LED Street Light fixture with Minimum lumen output 13500 lm |
| 732 | LED Street Light fixture with Minimum lumen output 16200 lm |
| 733 | LED Street Light fixture with Minimum lumen output 20250 lm |
| 734 | LED Street Light fixture with Minimum lumen output 24300 lm |
| 735 | LED Street Light fixture with Minimum lumen output 28350 lm |
| 736 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED/ integrated lens diffuser & should be High power LED of 3 to 5 watt each . The System efficacy >=125 lm/ wt and integrated metal case potted driver & has a unique BIS R number ( as per IS 15885) with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . LED driving output current <750mA. The luminaire shall be BIS certified (Fitting & driver both have separte BIS R number) and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs as required. |
| 737 | LED Street Light fixture with Minimum lumen output 2500 lm |
| 738 | LED Street Light fixture with Minimum lumen output 3750 lm |
| 739 | LED Street Light fixture with Minimum lumen output 5625 lm |
| 740 | LED Street Light fixture with Minimum lumen output 7500 lm |
| 741 | LED Street Light fixture with Minimum lumen output 8750 lm |
| 742 | LED Street Light fixture with Minimum lumen output 11250 lm |
| 743 | LED Street Light fixture with Minimum lumen output 12500 lm |
| 744 | LED Street Light fixture with Minimum lumen output 15000 lm |
| 745 | LED Street Light fixture with Minimum lumen output 18750 lm |
| 746 | LED Street Light fixture with Minimum lumen output 22500 lm |
| 747 | LED Street Light fixture with Minimum lumen output 26250 lm |
| 748 | Providing & Fixing of IK08 IP65 protected 600-800 mm height LED Bollard Luminarie with base plate made of powder coated die cast aluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy ≥ 80 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<20% and input Voltage range of 90-270V AC at 50Hz. System life of 30000 Burning hours with 70% of Initial Lumens maintained Light output in Cool white or Warm White Colour as per engineers choice. LED driving output current <750mA. as required. |
| 749 | Minimum lumen output 800 lm Bollard |
| 750 | Minimum lumen output 980 lm Bollard |
| 751 | Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, U/UTP (Unscreened/Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by LSZH Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies ranging from 250 to 500 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. |
| 752 | Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with HDPE, U/UTP (Unscreened/Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Outdoor ECCS armoured Cable as per latest ammendments of ANSI/TIA/EIA-568 C.2 & ISO/IEC 11801 2nd Ed, The copper conductors should be balanced twisted in pairs, seperated by a cross divider & protected by PVC outer jacket of UV resistant. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies ranging from 250 Mhz to 500 Mhz. Should meet IEEE 802.3af & IEEE 802.3at for POE applications. Cable Should support Ethernet 10GBASE-T according to the standards. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required. |
| 753 | Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with HDPE, Category 6A/Class Ea, U/FTP (Unshielded/Foiled Twisted Pair), 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 C.2 & ISO/IEC 11801 2nd Ed, The copper conductors should be balanced twisted in pairs, Shielded and Aluminum Foil Sheilding of Individual pairs protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies 500 Mhz. Should meet IEEE 802.3af & IEEE 802.3at for POE applications. Cable Should support Ethernet 10GBASE-T according to the standards. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required. |
| 754 | Supply and Installation of unshielded/360 degree shielded PCB based Information outlets made of high impact plastic body with ABS, Flammability rating UL 94 V-0 with provision for protection against dust in jack or Faceplate, suitable for Cat 6/6A application complying to latest amendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat 6/6A standards at frequencies 250/ 500 MHz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have toolless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA 568 C.2 & ISO/IEC 11801 or latest standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocol (VOIP) Specifications in existing modular/MS Boxes along with necessary connections as required. All as per pre approved by Engineer in charge. |
| 755 | Cat 6, Un-sheilded Information Outlet |
| 756 | Cat 6A, Sheilded Information Outlet |
| 757 | Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture with dust cover, material should be High-impact, flame retardant, thermoplastic, UL listed material, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect. All as per pre approved by Engineer in charge. |
| 758 | Single Aperture |
| 759 | Dual Aperture |
| 760 | Quad Aperture |
| 761 | Supply, Installation, Testing and Commissioning of Rack mounted 19\\" 1U, 24 Port loaded, CRS chasis, powder coated, sheet steel, High-impact, flame retardant, thermoplastic, UL Listed, Modular Patch Panels with Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required. All as per pre approved by Engineer in charge. |
| 762 | Modular Patch Panel Loaded with Cat -6 I/O |
| 763 | Modular Patch Panel Loaded with Cat -6A I/O |
| 764 | Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP). |
| 765 | Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord |
| 766 | 0.50 Mtr |
| 767 | 1 Mtr |
| 768 | 2 Mtr |
| 769 | 3 Mtr |
| 770 | Cat 6A, U/FTP (Unscreened/Foiled Twisted Pair) Patch Cord |
| 771 | 0.50 Mtr |
| 772 | 1 Mtr |
| 773 | 2 Mtr |
| 774 | 3 Mtr |
| 775 | Supply, Installation, & Testing of 19\\" 1U Rack Mounted/ surface mounted aluminum/ CRCA powder coated, OS2 Single mode glass Fiber Optic Cable Patch panel/LIU loaded with flangeless/screwable duplex adapters for SC/LC/SN/CS type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleeves, screws, nuts to install the panel for rackmount applications as per requirement complete in all respect. All as per pre approved by Engineer in charge. |
| 776 | 6 Ports |
| 777 | 12 Ports |
| 778 | SITC of Single Stage, water cooled, High Speed (2880 RPM), Horizontal, Centrifugal, Openwell Submersible pumps set pre filled with coolent water and fitted with mechanical seal. The motor body of single phase pump shall be of SS and rest of all shall be of cast iron. Shaft of three phase pump shall be of SS 410 grade. All casting parts should be cathod electro deposition (CED) coated. Motor winding shall be 100% copper wire material. Dynamically balanced rotating parts to ensure min. vibration etc. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect. |
| 779 | 0.5 HP, 1-Ø, (7 -18) Mtr, (180 - 20) LPM |
| 780 | 1.0 HP, 1-Ø, (12 -27) Mtr, (200- 30) LPM |
| 781 | 1.5 HP, 1-Ø, (18 -33) Mtr, (160-35) LPM |
| 782 | 2.0 HP, 1-Ø, (9 -21) Mtr, (475 - 130) LPM |
| 783 | 3.0 HP, 3-Ø, (17 -27) Mtr, (680 - 250) LPM |
| 784 | 5.0 HP, 3-Ø, (13 -36) Mtr, (995-200) LPM |
| 785 | 7.5 HP, 3-Ø, (12 -32) Mtr, (1650-400) LPM |
| 786 | 10.0 HP, 3-Ø, (15 -36) Mtr, (1860 - 700) LPM |
| 787 | SITC of Radial / mixed flow water and anti-corrosive liquid filled submersible motor pump sets suitable for 100/150mm dia borewell. The size of adopter fixed on top of the motor should exceed the top of coupler , for safegaurd the coupler. The job includes labour part of lowering of riser pipe G.I./ H.D.P.E. with rope, cables & pump, installation of complete fitting and accessories, jointing of electrical cables up to Starter. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect. |
| 788 | 100 mm diameter Submersible pump shall have following HP Rating, phase, Head range, Discharge range respectively. |
| 789 | 1.0 HP, 1-Ø, (10 - 83)Mtr, (40- 10) LPM |
| 790 | 1.5HP, 1-Ø, (11 - 94)Mtr, (40 - 10) LPM |
| 791 | 2.0 HP, 1-Ø, (7- 95)Mtr, (55-22) LPM |
| 792 | 3.0 HP, 1-Ø, (40 -170)Mtr, (60- 20) LPM Copper Wound |
| 793 | 5.0 HP, 1-Ø, (56 - 236)Mtr, (90 - 25) LPM Copper wound |
| 794 | 150 mm diameter Submersible pump shall have following HP Rating, phase, Head range, Discharge range respectively. |
| 795 | 3.0 HP, 3-Ø, (40 -110)Mtr, (280-50) LPM |
| 796 | 5.0 HP, 3-Ø, (72 - 161)Mtr, (230-48) LPM |
| 797 | 7.5 HP, 3-Ø, (85-165)Mtr, (300-100) LPM |
| 798 | 10.0 HP, 3-Ø, (110 - 212)Mtr, (400-167) LPM |
| 799 | SITC of Monoblock closed coupled motor pump set with TEFC motor, motor should be IP55-F class and IE2 efficiency for monobloc, with carbon steel /SS-410 shaft, Mechanical seal, Single/Three phase Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively and Dynamically balanced rotating parts to ensure min. vibration etc. complete in all respect. |
| 800 | 0.5 HP, 1-Ø, (8 - 26)Mtr, (50-10) LPM (SS Impellor & SS Body) |
| 801 | 0.5 HP, 1-Ø, (8 - 26)Mtr, (50-10) LPM ( Bronze impeller & CI Body) |
| 802 | 1.0 HP, 1-Ø, (10-30)Mtr, (76-28) LPM ( Bronze impeller & Aluminium Body) |
| 803 | 1.0 HP, 1-Ø, (10-30)Mtr, (76-28) LPM ( Bronze impeller & CI Body) |
| 804 | 1.5 HP, 1-Ø, (15-40)Mtr, (78-15) LPM ( Bronze impeller & CI Body) |
| 805 | 2.0 HP, 1-Ø, (6-27)Mtr, (250-100) LPM ( Bronze impeller & CI Body) |
| 806 | 2.0 HP, 3-Ø, (6-27)Mtr, (250-100) LPM ( Bronze impeller & CI Body) |
| 807 | SITC of Pressure boosting pump with MS Tank, pressure switch, pressure gauge, and all standard fittings fully automatic ON / OFF system, 2900 RPM with stainless steel casing, & impellor suitable for following capacity complete in all respect. |
| 808 | 0.5 HP ( 12 - 26 ) Mtr, (50 - 10 ) with 8 Ltr tank |
| 809 | 0.75 HP -0.90 HP ( 10 - 34 ) Mtr, (72 - 5 ) LPM with 24 Ltr Tank |
| 810 | 1.0 HP ( 10 - 38 ) Mtr, (76 - 8 ) LPM with 24 Ltr Tank |
| 811 | 1.5 HP ( 18-44 ) Mtr, (10-78 ) LPM with 35 ltr tank |
| 812 | Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM must ensure that the cable is tested for complaince, either through their in house laboratory accrediated by NABL or by any Govt. laboratory accrediated by NABL and the laboratory's scope of accrediation should cover the requirements and testing procedure as per IS:10810. |
| 813 | Un Armoured |
| 814 | 2 core x 1.0 Sq.mm |
| 815 | 2 core x 1.5 Sq.mm |
| 816 | 2 core x 2.5 Sq.mm |
| 817 | 4 core x 2.5 Sq.mm |
| 818 | Armoured |
| 819 | 2 core x 1.0 Sq.mm |
| 820 | 2 core x 1.5 Sq.mm |
| 821 | 2 core x 2.5 Sq.mm |
| 822 | 4 core x 2.5 Sq.mm |
| 823 | Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. |
| 824 | 20 mm |
| 825 | 25 mm |
| 826 | Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia |
| 827 | 50 mm dia per running inch length |
| 828 | 100 mm dia per running inch length |
| 829 | 150 mm dia per running inch length |
| 830 | Providing and making wall openings in existing stone / Brick masonry partition wall complete with all requited T & P, Scaffolding and providing lintel of required size and strength, repairing, plastering and cleaning the site debris as required. |
| 831 | SITC of RO water system with Filteration stages = Particilate filter- Membrane life enhancer filter- sediment filter- pre carbon filter- RO membrane filter- post carbon filter. Input power rating -230V AC, 50Hz, percentage of rejection TDS-90% or better, having following features (a) Double purification by RO with ESS or latest technology with TDS indicator. (b) Spin welded RO membrane housing to prevent tempering. (c) Push fit component for leak proof performance. (d) Fully automatic operation with auto start and auto off. (e) SS/ABS construction for corrosion free lifespan. (f) Equally suitable for water from all borewells, overhead storage tanks, water tankers and even municipal taps. (g) RO membrane flushing - Auto flush@ every start, every stop and every one hour of working for one minute, complete in all respect with following capacity. |
| 832 | Production capacity- 15 LPH, Water storage capacity 8 ltr |
| 833 | Supply and Fixing of Desert Cooler having cooling capacity of 5000 cum/hr., approx. size of cooler is 28\\"x28\\"x38\\" and having tank of 9\\" height with 20\\" 1400 rpm heavy duty fan motor and required size of submersible pump and all other required accessories. Cooler should be made of 18 SWG GI sheet for tank and remaining cooler body should be of 20 SWG GI sheet, grill of size 22\\"x25\\" including required size angle iron stand duly painted with 2 coats of red oxide and one coat of enamel paint complete in all respect as required. |
| 834 | SITC of Interconnecting refrigerant copper pipe for split/Ductable/ Casseette AC of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. Piping between each set of indoor & outdoor units of different sizes as per OEM requirement & specifications including class 'O' Nitrile rubber sleeves (size as per item no. 22.43),7 mil Glass Cloth with 3 coats of anti UV paint (on area which is exposed to weather) chase cutting, supports, making good the same with sand cement plaster etc. as required. |
| 835 | Gravelling of Transformer / RMU Yard with 100 mm Height Gravels of Size 20 to 25 mm including leveling, Dressing etc. as Required. |
| 836 | Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. . |
| 837 | Providing & Laying XLPE insulated & P.V.C. sheathed Un-Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing commissioning etc. as required of following size. |
| 838 | 4.0 Sq. mm |
| 839 | 2 core |
| 840 | 3 core |
| 841 | 4 core |
| 842 | 6.0 Sq. mm |
| 843 | 2 core |
| 844 | 3 core |
| 845 | 4 core |
| 846 | 10.0 Sq. mm |
| 847 | 2 core |
| 848 | 3 core |
| 849 | 4 core |
| 850 | 16.0 Sq. mm |
| 851 | 2 core |
| 852 | 3 core |
| 853 | 4 core |
| 854 | 25.0 Sq. mm |
| 855 | 2 core |
| 856 | 3 core |
| 857 | 3.5 core |
| 858 | 35.0 Sq. mm |
| 859 | 2 core |
| 860 | 3 core |
| 861 | 3.5 core |
| 862 | Supply & Installation of IP-20 & IK-08 , Wall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with 'U'Marking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19\\" angles with wall mounting provision on wall. Accessories like: 1 No of 19\\" 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19\\" 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastner etc as required. |
| 863 | 6 U Rack with Width 600 mm & Depth 400 mm + 100 mm |
| 864 | 9 U Rack with Width 600 mm & Depth 400 mm + 100 mm |
| 865 | Supply , Installation, Testing and Comissioning of Unmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100/1000 MBPS auto-negotiation RJ45 ports, IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. |
| 866 | 8 Port |
| 867 | 16 Port |
| 868 | 24 Port |
| 869 | Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. |
| 870 | 32 mm Dia. |
| 871 | Providing & Fixing of IP - 65 protected impact resistant polycarbonate / Polysterene enclosures with knock out for cable entry/out including fixing with nut, bolt, fatner etc as required complete in all respect of following sizes. |
| 872 | 180 x 180 x 91 mm |
| 873 | SITC of Line Card for required Analog / Digital / CO Extensions. compatible to the IP PBX as required. |
| 874 | CLI based Telephone Instrument, with Caller ID, 2 way /Hands free speaker, 16 Digit LCD Display, Adj. volume Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail